Normalized to: Lebeda, O.
[1]
oai:arXiv.org:1909.06048 [pdf] - 2007972
An improved upper limit on the neutrino mass from a direct kinematic
method by KATRIN
Aker, M.;
Altenmüller, K.;
Arenz, M.;
Babutzka, M.;
Barrett, J.;
Bauer, S.;
Beck, M.;
Beglarian, A.;
Behrens, J.;
Bergmann, T.;
Besserer, U.;
Blaum, K.;
Block, F.;
Bobien, S.;
Bokeloh, K.;
Bonn, J.;
Bornschein, B.;
Bornschein, L.;
Bouquet, H.;
Brunst, T.;
Caldwell, T. S.;
La Cascio, L.;
Chilingaryan, S.;
Choi, W.;
Corona, T. J.;
Debowski, K.;
Deffert, M.;
Descher, M.;
Doe, P. J.;
Dragoun, O.;
Drexlin, G.;
Dunmore, J. A.;
Dyba, S.;
Edzards, F.;
Eisenblätter, L.;
Eitel, K.;
Ellinger, E.;
Engel, R.;
Enomoto, S.;
Erhard, M.;
Eversheim, D.;
Fedkevych, M.;
Felden, A.;
Fischer, S.;
Flatt, B.;
Formaggio, J. A.;
Fränkle, F. M.;
Franklin, G. B.;
Frankrone, H.;
Friedel, F.;
Fuchs, D.;
Fulst, A.;
Furse, D.;
Gauda, K.;
Gemmeke, H.;
Gil, W.;
Glück, F.;
Görhardt, S.;
Groh, S.;
Grohmann, S.;
Grössle, R.;
Gumbsheimer, R.;
Minh, M. Ha;
Hackenjos, M.;
Hannen, V.;
Harms, F.;
Hartmann, J.;
Haußmann, N.;
Heizmann, F.;
Helbing, K.;
Hickford, S.;
Hilk, D.;
Hillen, B.;
Hillesheimer, D.;
Hinz, D.;
Höhn, T.;
Holzapfel, B.;
Holzmann, S.;
Houdy, T.;
Howe, M. A.;
Huber, A.;
Jansen, A.;
Kaboth, A.;
Karl, C.;
Kazachenko, O.;
Kellerer, J.;
Kernert, N.;
Kippenbrock, L.;
Kleesiek, M.;
Klein, M.;
Köhler, C.;
Köllenberger, L.;
Kopmann, A.;
Korzeczek, M.;
Kosmider, A.;
Kovalí, A.;
Krasch, B.;
Kraus, M.;
Krause, H.;
Kuckert, L.;
Kuffner, B.;
Kunka, N.;
Lasserre, T.;
Le, T. L.;
Lebeda, O.;
Leber, M.;
Lehnert, B.;
Letnev, J.;
Leven, F.;
Lichter, S.;
Lobashev, V. M.;
Lokhov, A.;
Machatschek, M.;
Malcherek, E.;
Müller, K.;
Mark, M.;
Marsteller, A.;
Martin, E. L.;
Melzer, C.;
Menshikov, A.;
Mertens, S.;
Minter, L. I.;
Mirz, S.;
Monreal, B.;
Guzman, P. I. Morales;
Müller, K.;
Naumann, U.;
Ndeke, W.;
Neumann, H.;
Niemes, S.;
Noe, M.;
Oblath, N. S.;
Ortjohann, H. -W.;
Osipowicz, A.;
Ostrick, B.;
Otten, E.;
Parno, D. S.;
Phillips, D. G.;
Plischke, P.;
Pollithy, A.;
Poon, A. W. P.;
Pouryamout, J.;
Prall, M.;
Priester, F.;
Röllig, M.;
Röttele, C.;
Ranitzsch, P. C. -O.;
Rest, O.;
Rinderspacher, R.;
Robertson, R. G. H.;
Rodenbeck, C.;
Rohr, P.;
Roll, Ch.;
Rupp, S.;
Rysavy, M.;
Sack, R.;
Saenz, A.;
Schäfer, P.;
Schimpf, L.;
Schlösser, K.;
Schlösser, M.;
Schlüter, L.;
Schön, H.;
Schönung, K.;
Schrank, M.;
Schulz, B.;
Schwarz, J.;
Seitz-Moskaliuk, H.;
Seller, W.;
Sibille, V.;
Siegmann, D.;
Skasyrskaya, A.;
Slezak, M.;
Spalek, A.;
Spanier, F.;
Steidl, M.;
Steinbrink, N.;
Sturm, M.;
Suesser, M.;
Sun, M.;
Tcherniakhovski, D.;
Telle, H. H.;
Thümmler, T.;
Thorne, L. A.;
Titov, N.;
Tkachev, I.;
Trost, N.;
Urban, K.;
Venos, D.;
Valerius, K.;
VanDevender, B. A.;
Vianden, R.;
Hernandez, A. P. Vizcaya;
Wall, B. L.;
Wüstling, S.;
Weber, M.;
Weinheimer, C.;
Weiss, C.;
Welte, S.;
Wendel, J.;
Wierman, K. J.;
Wilkerson, J. F.;
Wolf, J.;
Xu, W.;
Yen, Y. -R.;
Zacher, M.;
Zadorozhny, S.;
Zboril, M.;
Zeller, G.
Submitted: 2019-09-13
We report on the neutrino mass measurement result from the first four-week
science run of the Karlsruhe Tritium Neutrino experiment KATRIN in spring 2019.
Beta-decay electrons from a high-purity gaseous molecular tritium source are
energy analyzed by a high-resolution MAC-E filter. A fit of the integrated
electron spectrum over a narrow interval around the kinematic endpoint at 18.57
keV gives an effective neutrino mass square value of $(-1.0^{+0.9}_{-1.1})$
eV$^2$. From this we derive an upper limit of 1.1 eV (90$\%$ confidence level)
on the absolute mass scale of neutrinos. This value coincides with the KATRIN
sensitivity. It improves upon previous mass limits from kinematic measurements
by almost a factor of two and provides model-independent input to cosmological
studies of structure formation.
[2]
oai:arXiv.org:1909.06069 [pdf] - 2080883
First operation of the KATRIN experiment with tritium
Aker, M.;
Altenmüller, K.;
Arenz, M.;
Baek, W. -J.;
Barrett, J.;
Beglarian, A.;
Behrens, J.;
Berlev, A.;
Besserer, U.;
Blaum, K.;
Block, F.;
Bobien, S.;
Bornschein, B.;
Bornschein, L.;
Bouquet, H.;
Brunst, T.;
Caldwell, T. S.;
Chilingaryan, S.;
Choi, W.;
Debowski, K.;
Deffert, M.;
Descher, M.;
Barrero, D. Díaz;
Doe, P. J.;
Dragoun, O.;
Drexlin, G.;
Dyba, S.;
Edzards, F.;
Eitel, K.;
Ellinger, E.;
Engel, R.;
Enomoto, S.;
Eversheim, D.;
Fedkevych, M.;
Felden, A.;
Formaggio, J. A.;
Fränkle, F. M.;
Franklin, G. B.;
Frankrone, H.;
Friedel, F.;
Fuchs, D.;
Fulst, A.;
Gauda, K.;
Gil, W.;
Glück, F.;
Grohmann, S.;
Grössle, R.;
Gumbsheimer, R.;
Hackenjos, M.;
Hannen, V.;
Hartmann, J.;
Haußmann, N.;
Minh, M. Ha;
Heizmann, F.;
Heizmann, J.;
Helbing, K.;
Hickford, S.;
Hillesheimer, D.;
Hinz, D.;
Höhn, T.;
Holzapfel, B.;
Holzmann, S.;
Houdy, T.;
Howe, M. A.;
Huber, A.;
Jansen, A.;
Karl, C.;
Kellerer, J.;
Kernert, N.;
Kippenbrock, L.;
Kleesiek, M.;
Klein, M.;
Köhler, C.;
Köllenberger, L.;
Kopmann, A.;
Korzeczek, M.;
Kovalík, A.;
Krasch, B.;
Krause, H.;
Kuffner, B.;
Kunka, N.;
Lasserre, T.;
La Cascio, L.;
Lebeda, O.;
Lebert, M.;
Lehnert, B.;
Letnev, J.;
Leven, F.;
Le, T. L.;
Lichter, S.;
Lokhov, A.;
Machatschek, M.;
Malcherek, E.;
Mark, M.;
Marsteller, A.;
Martin, E. L.;
Megas, F.;
Melzer, C.;
Menshikov, A.;
Mertens, S.;
Meier, M.;
Mirz, S.;
Monreal, B.;
Guzmán, P. I. Morales;
Müller, K.;
Naumann, U.;
Neumann, H.;
Niemes, S.;
Noe, M.;
Off, A.;
Ortjohann, H. -W.;
Osipowicz, A.;
Otten, E.;
Parno, D. S.;
Pollithy, A.;
Poon, A. W. P.;
Poyato, J. M. L.;
Priester, F.;
Ranitzsch, P. C. -O.;
Rest, O.;
Rinderspacher, R.;
Robertson, R. G. H.;
Rodenbeck, C.;
Rohr, P.;
Röllig, M.;
Röttele, C.;
Ryšavý, M.;
Sack, R.;
Saenz, A.;
Schäfer, P.;
Schimpf, L.;
Schlösser, K.;
Schlösser, M.;
Schlüter, L.;
Schrank, M.;
Schulz, B.;
Seitz-Moskaliuk, H.;
Seller, W.;
Sibille, V.;
Siegmann, D.;
Slezák, M.;
Spanier, F.;
Steidl, M.;
Steven, M.;
Sturm, M.;
Suesser, M.;
Sun, M.;
Tcherniakhovski, D.;
Telle, H. H.;
Thorne, L. A.;
Thümmler, T.;
Titov, N.;
Tkachev, I.;
Trost, N.;
Urban, K.;
Valerius, K.;
Vénos, D.;
Vianden, R.;
Hernández, A. P. Vizcaya;
Weber, M.;
Weinheimer, C.;
Weiss, C.;
Welte, S.;
Wendel, J.;
Wilkerson, J. F.;
Wolf, J.;
Wüstling, S.;
Xu, W.;
Yen, Y. -R.;
Zadorozhny, S.;
Zeller, G.
Submitted: 2019-09-13
The determination of the neutrino mass is one of the major challenges in
astroparticle physics today. Direct neutrino mass experiments, based solely on
the kinematics of beta-decay, provide a largely model-independent probe to the
neutrino mass scale. The Karlsruhe Tritium Neutrino (KATRIN) experiment is
designed to directly measure the effective electron antineutrino mass with a
sensitivity of 0.2 eV 90% CL. In this work we report on the first operation of
KATRIN with tritium which took place in 2018. During this commissioning phase
of the tritium circulation system, excellent agreement of the theoretical
prediction with the recorded spectra was found and stable conditions over a
time period of 13 days could be established. These results are an essential
prerequisite for the subsequent neutrino mass measurements with KATRIN in 2019.
[3]
oai:arXiv.org:1407.3981 [pdf] - 913083
A novel $^{83\mathrm{m}}$Kr tracer method for characterizing xenon gas
and cryogenic distillation systems
Rosendahl, S.;
Bokeloh, K.;
Brown, E.;
Cristescu, I.;
Fieguth, A.;
Huhmann, C.;
Lebeda, O.;
Levy, C.;
Murra, M.;
Schneider, S.;
Vénos, D.;
Weinheimer, C.
Submitted: 2014-07-15
The radioactive isomer $^{83\mathrm{m}}$Kr has many properties that make it
very useful for various applications. Its low energy decay products, like
conversion, shake-off and Auger electrons as well as X- and $\gamma$-rays are
used for calibration purposes in neutrino mass experiments and direct dark
matter detection experiments. Thanks to the short half-life of 1.83 h and the
decay to the ground state $^{83}$Kr, one does not risk contamination of any
low-background experiment with long- lived radionuclides. In this paper, we
present two new applications of $^{83\mathrm{m}}$Kr. It can be used as a
radioactive tracer in noble gases to characterize the particle flow inside of
gas routing systems. A method of doping $^{83\mathrm{m}}$Kr into xenon gas and
its detection, using special custom-made detectors, based on a photomultiplier
tube, is described. This technique has been used to determine the circulation
speed of gas particles inside of a gas purification system for xenon.
Furthermore, 83m Kr can be used to rapidly estimate separation performance of a
distillation system.
[4]
oai:arXiv.org:1109.4270 [pdf] - 427699
Limits on the release of Rb isotopes from a zeolite based 83mKr
calibration source for the XENON project
Hannen, V.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Beck, M.;
Bokeloh, K.;
Ferella, A. D.;
Giboni, K.;
Lang, R. F.;
Lebeda, O.;
Ortjohann, H. -W.;
Schumann, M.;
Spalek, A.;
Venos, D.;
Weinheimer, C.
Submitted: 2011-09-20, last modified: 2011-10-06
The isomer 83mKr with its half-life of 1.83 h is an ideal calibration source
for a liquid noble gas dark matter experiment like the XENON project. However,
the risk of contamination of the detector with traces of the much longer lived
mother isotop 83Rb (86.2 d half-life) has to be ruled out. In this work the
release of 83Rb atoms from a 1.8 MBq 83Rb source embedded in zeolite beads has
been investigated. To do so, a cryogenic trap has been connected to the source
for about 10 days, after which it was removed and probed for the strongest 83Rb
gamma-rays with an ultra-sensitive Germanium detector. No signal has been
found. The corresponding upper limit on the released 83Rb activity means that
the investigated type of source can be used in the XENON project and similar
low-background experiments as 83mKr generator without a significant risk of
contaminating the detector. The measurements also allow to set upper limits on
the possible release of the isotopes 84Rb and 86Rb, traces of which were
created alongside the production of 83Rb at the Rez cyclotron.
[5]
oai:arXiv.org:0908.0616 [pdf] - 205480
Spatially uniform calibration of a liquid xenon detector at low energies
using 83m-Kr
Manalaysay, A.;
Undagoitia, T. Marrodan;
Askin, A.;
Baudis, L.;
Behrens, A.;
Ferella, A. D.;
Kish, A.;
Lebeda, O.;
Santorelli, R.;
Venos, D.;
Vollhardt, A.
Submitted: 2009-08-05, last modified: 2010-05-16
A difficult task with many particle detectors focusing on interactions below
~100 keV is to perform a calibration in the appropriate energy range that
adequately probes all regions of the detector. Because detector response can
vary greatly in various locations within the device, a spatially uniform
calibration is important. We present a new method for calibration of liquid
xenon (LXe) detectors, using the short-lived 83m-Kr. This source has
transitions at 9.4 and 32.1 keV, and as a noble gas like Xe, it disperses
uniformly in all regions of the detector. Even for low source activities, the
existence of the two transitions provides a method of identifying the decays
that is free of background. We find that at decreasing energies, the LXe light
yield increases, while the amount of electric field quenching is diminished.
Additionally, we show that if any long-lived radioactive backgrounds are
introduced by this method, they will present less than 67E-6 events/kg/day in
the next generation of LXe dark matter direct detection searches