Normalized to: Lawson, T.
[1]
oai:arXiv.org:2006.13589 [pdf] - 2121558
Evaluation of the $^{13}$N($\alpha$,p)$^{16}$O thermonuclear reaction
rate and its impact on the isotopic composition of supernova grains
Meyer, A.;
de Séréville, N.;
Laird, A. M.;
Hammache, F.;
Longland, R.;
Lawson, T.;
Pignatari, M.;
Audouin, L.;
Beaumel, D.;
Fortier, S.;
Kiener, J.;
Lefebvre-Schuhl, A.;
Pellegriti, M. G.;
Stanoiu, M.;
Tatischeff, V.
Submitted: 2020-06-24
It has been suggested that hydrogen ingestion into the helium shell of
massive stars could lead to high $^{13}$C and $^{15}$N excesses when the shock
of a core-collapse supernova passes through its helium shell. This prediction
questions the origin of extremely high $^{13}$C and $^{15}$N abundances
observed in rare presolar SiC grains which is usually attributed to classical
novae. In this context $^{13}$N($\alpha$,p)$^{16}$O the reaction plays an
important role since it is in competition with $^{13}$N $\beta^+$-decay to
$^{13}$C. The $^{13}$N($\alpha$,p)$^{16}$O reaction rate used in stellar
evolution calculations comes from the CF88 compilation with very scarce
information on the origin of this rate. The goal of this work is to provide a
recommended $^{13}$N($\alpha$,p)$^{16}$O reaction rate, based on available
experimental data. Unbound nuclear states in the $^{17}$F compound nucleus were
studied using the spectroscopic information of the analog states in $^{17}$O
nucleus that were measured at the Alto facility using the
$^{13}$C($^7$Li,t)$^{17}$O alpha-transfer reaction, and spectroscopic factors
were derived using a DWBA analysis. This spectroscopic information was used to
calculate a recommended $^{13}$N($\alpha$,p)$^{16}$O reaction rate with
meaningful uncertainty using a Monte Carlo approach. The present
$^{13}$N($\alpha$,p)$^{16}$O reaction rate is found to be within a factor of
two of the previous evaluation, with a typical uncertainty of a factor 2-3. The
source of this uncertainty comes from the three resonances at $E_r^{c.m.} =
221$, 741 and 959 keV. This new error estimation translates to an overall
uncertainty in the $^{13}$C production of a factor of 50. The main source of
uncertainty on the re-evaluated $^{13}$N($\alpha$,p)$^{16}$O reaction rate
currently comes from the uncertain alpha-width of relevant $^{17}$F states.
[2]
oai:arXiv.org:0911.0323 [pdf] - 902277
The case for a directional dark matter detector and the status of
current experimental efforts
Ahlen, S.;
Afshordi, N.;
Battat, J. B. R.;
Billard, J.;
Bozorgnia, N.;
Burgos, S.;
Caldwell, T.;
Carmona, J. M.;
Cebrian, S.;
Colas, P.;
Dafni, T.;
Daw, E.;
Dujmic, D.;
Dushkin, A.;
Fedus, W.;
Ferrer, E.;
Finkbeiner, D.;
Fisher, P. H.;
Forbes, J.;
Fusayasu, T.;
Galan, J.;
Gamble, T.;
Ghag, C.;
Giomataris, I.;
Gold, M.;
Gomez, H.;
Gomez, M. E.;
Gondolo, P.;
Green, A.;
Grignon, C.;
Guillaudin, O.;
Hagemann, C.;
Hattori, K.;
Henderson, S.;
Higashi, N.;
Ida, C.;
Iguaz, F. J.;
Inglis, A.;
Irastorza, I. G.;
Iwaki, S.;
Kaboth, A.;
Kabuki, S.;
Kadyk, J.;
Kallivayalil, N.;
Kubo, H.;
Kurosawa, S.;
Kudryavtsev, V. A.;
Lamy, T.;
Lanza, R.;
Lawson, T. B.;
Lee, A.;
Lee, E. R.;
Lin, T.;
Loomba, D.;
Lopez, J.;
Luzon, G.;
Manobu, T.;
Martoff, J.;
Mayet, F.;
Mccluskey, B.;
Miller, E.;
Miuchi, K.;
Monroe, J.;
Morgan, B.;
Muna, D.;
Murphy, A. St. J.;
Naka, T.;
Nakamura, K.;
Nakamura, M.;
Nakano, T.;
Nicklin, G. G.;
Nishimura, H.;
Niwa, K.;
Paling, S. M.;
Parker, J.;
Petkov, A.;
Pipe, M.;
Pushkin, K.;
Robinson, M.;
Rodriguez, A.;
Rodriguez-Quintero, J.;
Sahin, T.;
Sanderson, R.;
Sanghi, N.;
Santos, D.;
Sato, O.;
Sawano, T.;
Sciolla, G.;
Sekiya, H.;
Slatyer, T. R.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Sugiyama, A.;
Takada, A.;
Takahashi, M.;
Takeda, A.;
Tanimori, T.;
Taniue, K.;
Tomas, A.;
Tomita, H.;
Tsuchiya, K.;
Turk, J.;
Tziaferi, E.;
Ueno, K.;
Vahsen, S.;
Vanderspek, R.;
Vergados, J.;
Villar, J. A.;
Wellenstein, H.;
Wolfe, I.;
Yamamoto, R. K.;
Yegoryan, H.
Submitted: 2009-11-01
We present the case for a dark matter detector with directional sensitivity.
This document was developed at the 2009 CYGNUS workshop on directional dark
matter detection, and contains contributions from theorists and experimental
groups in the field. We describe the need for a dark matter detector with
directional sensitivity; each directional dark matter experiment presents their
project's status; and we close with a feasibility study for scaling up to a one
ton directional detector, which would cost around $150M.
[3]
oai:arXiv.org:0809.1831 [pdf] - 16182
First measurement of the Head-Tail directional nuclear recoil signature
at energies relevant to WIMP dark matter searches
Burgos, S.;
Daw, E.;
Forbes, J.;
Ghag, C.;
Gold, M.;
Hagemann, C.;
Kudryavtsev, V. A.;
Lawson, T. B.;
Loomba, D.;
Majewski, P.;
Muna, D.;
Murphy, A. StJ.;
Nicklin, G. G.;
Paling, S. M.;
Petkov, A.;
Plank, S. J. S.;
Robinson, M.;
Sanghi, N.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Turk, J.;
Tziaferi, E.
Submitted: 2008-09-10
We present first evidence for the so-called Head-Tail asymmetry signature of
neutron-induced nuclear recoil tracks at energies down to 1.5 keV/amu using the
1m^3 DRIFT-IIc dark matter detector. This regime is appropriate for recoils
induced by Weakly Interacting Massive Particle (WIMPs) but one where the
differential ionization is poorly understood. We show that the distribution of
recoil energies and directions induced here by Cf-252 neutrons matches well
that expected from massive WIMPs. The results open a powerful new means of
searching for a galactic signature from WIMPs.
[4]
oai:arXiv.org:0807.3969 [pdf] - 14845
Measurement of the Range Component Directional Signature in a DRIFT-II
Detector using 252Cf Neutrons
Burgos, S.;
Daw, E.;
Forbes, J.;
Ghag, C.;
Gold, M.;
Hagemann, C.;
Kudryavtsev, V. A.;
Lawson, T. B.;
Loomba, D.;
Majewski, P.;
Muna, D.;
Murphy, A. St. J.;
Nicklin, G. G.;
Paling, S. M.;
Petkov, A.;
Plank, S. J. S.;
Robinson, M.;
Sanghi, N.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Turk, J.;
Tziaferi, E.
Submitted: 2008-07-24
The DRIFT collaboration utilizes low pressure gaseous detectors to search for
WIMP dark matter with directional signatures. A 252Cf neutron source was placed
on each of the principal axes of a DRIFT detector in order to test its ability
to measure directional signatures from the three components of very low energy
(~keV/amu) recoil ranges. A high trigger threshold and the event selection
procedure ensured that only sulfur recoils were analyzed. Sulfur recoils
produced in the CS2 target gas by the 252Cf source closely match those expected
from massive WIMP induced sulfur recoils. For each orientation of the source a
directional signal from the range components was observed, indicating that the
detector is directional along all 3 axes. An analysis of these results yields
an optimal orientation for DRIFT detectors when searching for a directional
signature from WIMPs. Additional energy dependent information is provided to
aid in understanding this effect.
[5]
oai:arXiv.org:astro-ph/0701858 [pdf] - 88987
First limits on WIMP nuclear recoil signals in ZEPLIN-II: a two phase
xenon detector for dark matter detection
Alner, G. J.;
Araujo, H. M.;
Bewick, A.;
Bungau, C.;
Camanzi, B.;
Carson, M. J.;
Cashmore, R. J.;
Chagani, H.;
Chepel, V.;
Cline, D.;
Davidge, D.;
Davies, J. C.;
Daw, E.;
Dawson, J.;
Durkin, T.;
Edwards, B.;
Gamble, T.;
Gao, J.;
Ghag, C.;
Howard, A. S.;
Jones, W. G.;
Joshi, M.;
Korolkova, E. V.;
Kudryavtsev, V. A.;
Lawson, T.;
Lebedenko, V. N.;
Lewin, J. D.;
Lightfoot, P.;
Lindote, A.;
Liubarsky, I.;
Lopes, M. I.;
Luscher, R.;
Majewski, P.;
Mavrokoridis, K;
McMillan, J. E.;
Morgan, B.;
Muna, D.;
Murphy, A. St. J.;
Neves, F.;
Nicklin, G. G.;
Ooi, W.;
Paling, S. M.;
da Cunha, J. Pinto;
Plank, S. J. S.;
Preece, R. M.;
Quenby, J. J.;
Robinson, M.;
Sergiampietri, F.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Spooner, N. J. C.;
Sumner, T. J.;
Thorne, C.;
Tovey, D. R.;
Tziaferi, E.;
Walker, R. J.;
Wang, H.;
White, J.;
Wolfs, F. L. H.
Submitted: 2007-01-30, last modified: 2007-01-31
Results are presented from the first underground data run of ZEPLIN-II, a 31
kg two phase xenon detector developed to observe nuclear recoils from
hypothetical weakly interacting massive dark matter particles. Discrimination
between nuclear recoils and background electron recoils is afforded by
recording both the scintillation and ionisation signals generated within the
liquid xenon, with the ratio of these signals being different for the two
classes of event. This ratio is calibrated for different incident species using
an AmBe neutron source and Co-60 gamma-ray sources. From our first 31 live days
of running ZEPLIN-II, the total exposure following the application of fiducial
and stability cuts was 225 kgxdays. A background population of radon progeny
events was observed in this run, arising from radon emission in the gas
purification getters, due to radon daughter ion decays on the surfaces of the
walls of the chamber. An acceptance window, defined by the neutron calibration
data, of 50% nuclear recoil acceptance between 5 keVee and 20 keVee, had an
observed count of 29 events, with a summed expectation of 28.6+/-4.3 gamma-ray
and radon progeny induced background events. These figures provide a 90% c.l.
upper limit to the number of nuclear recoils of 10.4 events in this acceptance
window, which converts to a WIMP-nucleon spin-independent cross-section with a
minimum of 6.6x10^-7 pb following the inclusion of an energy dependent,
calibrated, efficiency. A second run is currently underway in which the radon
progeny will be eliminated, thereby removing the background population, with a
projected sensitivity of 2x10^-7 pb for similar exposures as the first run.
[6]
oai:arXiv.org:astro-ph/0605500 [pdf] - 82187
The ZEPLIN-III dark matter detector: instrument design, manufacture and
commissioning
Akimov, D. Yu.;
Alner, G. J.;
Araujo, H. M.;
Bewick, A.;
Bungau, C.;
Burenkov, A. A.;
Carson, M. J.;
Chepel, V.;
Cline, D.;
Davidge, D.;
Davies, J. C.;
Daw, E.;
Dawson, J.;
Durkin, T.;
Edwards, B.;
Gamble, T.;
Chag, C.;
Hollingworth, R. J.;
Howard, A. S.;
Jones, W. G.;
Joshi, M.;
Kirkpatrick, J.;
Kovalenko, A.;
Kudryavtsev, V. A.;
Kuznetsov, I. S.;
Lawson, T.;
Lebedenko, V. N.;
Lewin, J. D.;
Lightfoot, P.;
Lindote, A.;
Liubarsky, I.;
Lopes, M. I.;
Luscher, R.;
McMillan, J. E.;
Morgan, B.;
Muna, D.;
Murphy, A. S.;
Neves, F.;
Nicklin, G. G.;
Paling, S. M.;
Muna, D.;
da Cunha, J. Pinto;
Plank, S. J. S.;
Preece, R.;
Quenby, J. J.;
Robinson, M.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Spooner, N. J. C.;
Stekhanov, V.;
Sumner, T. J.;
Thorne, C.;
Tovey, D. R.;
Tziaferi, E.;
Walker, R. J.;
Wang, H.;
White, J.;
Wolfs, F.
Submitted: 2006-05-19
We present details of the technical design and manufacture of the ZEPLIN-III
dark matter experiment. ZEPLIN-III is a two-phase xenon detector which measures
both the scintillation light and the ionisation charge generated in the liquid
by interacting particles and radiation. The instrument design is driven by both
the physics requirements and by the technology requirements surrounding the use
of liquid xenon. These include considerations of key performance parameters,
such as the efficiency of scintillation light collection, restrictions placed
on the use of materials to control the inherent radioactivity levels,
attainment of high vacuum levels and chemical contamination control. The
successful solution has involved a number of novel design and manufacturing
features which will be of specific use to future generations of direct dark
matter search experiments as they struggle with similar and progressively more
demanding requirements.
[7]
oai:arXiv.org:astro-ph/0603243 [pdf] - 80452
The ZEPLIN-III dark matter detector: performance study using an
end-to-end simulation tool
Araujo, H. M.;
Akimov, D. Yu.;
Alner, G. J.;
Bewick, A.;
Bungau, C.;
Camanzi, B.;
Carson, M. J.;
Chepel, V.;
Chagani, H.;
Davidge, D.;
Davies, J. C.;
Daw, E.;
Dawson, J.;
Durkin, T.;
Edwards, B.;
Gamble, T.;
Ghag, C.;
Hollingworth, R.;
Howard, A. S.;
Jones, W. G.;
Joshi, M.;
Kirkpatrick, J.;
Kovalenko, A.;
Kudryavtsev, V. A.;
Lebedenko, V. N.;
Lawson, T.;
Lewin, J. D.;
Lightfoot, P.;
Lindote, A.;
Liubarsky, I.;
Lopes, M. I.;
Luscher, R.;
Majewski, P.;
Mavrokoridis, K.;
McMillan, J.;
Morgan, B.;
Muna, D.;
Murphy, A. S.;
Neves, F.;
Nicklin, G.;
Paling, S.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Robinson, M.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Spooner, N. J. C.;
Stekhanov, V.;
Sumner, T. J.;
Tovey, D. R.;
Thorne, C.;
Tziaferi, E.;
Walker, R. J.
Submitted: 2006-03-09
We present results from a GEANT4-based Monte Carlo tool for end-to-end
simulations of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase
detector which measures both the scintillation light and the ionisation charge
generated in liquid xenon by interacting particles and radiation. The software
models the instrument response to radioactive backgrounds and calibration
sources, including the generation, ray-tracing and detection of the primary and
secondary scintillations in liquid and gaseous xenon, and subsequent processing
by data acquisition electronics. A flexible user interface allows easy
modification of detector parameters at run time. Realistic datasets can be
produced to help with data analysis, an example of which is the position
reconstruction algorithm developed from simulated data. We present a range of
simulation results confirming the original design sensitivity of a few times
$10^{-8}$ pb to the WIMP-nucleon cross-section.
[8]
oai:arXiv.org:hep-ex/0109013 [pdf] - 363345
Study and suppression of anomalous fast events in inorganic
scintillators for dark matter searches
Kudryavtsev, V. A.;
Spooner, N. J. C.;
Lightfoot, P. K.;
Roberts, J. W.;
Lehner, M. J.;
Gamble, T.;
Carson, M. J.;
Lawson, T. B.;
Luscher, R.;
McMillan, J. E.;
Morgan, B.;
Paling, S. M.;
Robinson, M.;
Tovey, D. R.;
Smith, N. J. T.;
Smith, P. F.;
Alner, G. J.;
Hart, S. P.;
Lewin, J. D.;
Preece, R. M.;
Sumner, T. J.;
Jones, W. G.;
Quenby, J. J.;
Ahmed, B.;
Bewick, A.;
Davidge, D.;
Dawson, J. V.;
Howard, A. S.;
Ivaniouchenkov, I.;
Joshi, M. K.;
Lebedenko, V.;
Liubarsky, I.;
Barton, J. C.;
Gerbier, G.;
Mallet, J.;
Mosca, L.;
Tao, C.
Submitted: 2001-09-12
The status of dark matter searches with inorganic scintillator detectors at
Boulby mine is reviewed and the results of tests with a CsI(Tl) crystal are
presented. The objectives of the latter experiment were to study anomalous fast
events previously observed and to identify ways to remove this background.
Clear indications were found that these events were due to surface
contamination of crystals by alphas, probably from radon decay. A new array of
unencapsulated NaI(Tl) crystals immersed either in liquid paraffin or pure
nitrogen atmosphere is under construction at Boulby. Such an approach allows
complete control of the surface of the crystals and the ability to remove any
surface contamination. First data from the unencapsulated NaI(Tl) do not show
the presence of anomalous fast events.