Normalized to: Laux, U.
[1]
oai:arXiv.org:1105.1265 [pdf] - 1076454
GRIPS - Gamma-Ray Imaging, Polarimetry and Spectroscopy
Greiner, J.;
Mannheim, K.;
Aharonian, F.;
Ajello, M.;
Balasz, L. G.;
Barbiellini, G.;
Bellazzini, R.;
Bishop, S.;
Bisnovatij-Kogan, G. S.;
Boggs, S.;
Bykov, A.;
DiCocco, G.;
Diehl, R.;
Elsässer, D.;
Foley, S.;
Fransson, C.;
Gehrels, N.;
Hanlon, L.;
Hartmann, D.;
Hermsen, W.;
Hillebrandt, W.;
Hudec, R.;
Iyudin, A.;
Jose, J.;
Kadler, M.;
Kanbach, G.;
Klamra, W.;
Kiener, J.;
Klose, S.;
Kreykenbohm, I.;
Kuiper, L. M.;
Kylafis, N.;
Labanti, C.;
Langanke, K.;
Langer, N.;
Larsson, S.;
Leibundgut, B.;
Laux, U.;
Longo, F.;
Maeda, K.;
Marcinkowski, R.;
Marisaldi, M.;
McBreen, B.;
McBreen, S.;
Meszaros, A.;
Nomoto, K.;
Pearce, M.;
Peer, A.;
Pian, E.;
Prantzos, N.;
Raffelt, G.;
Reimer, O.;
Rhode, W.;
Ryde, F.;
Schmidt, C.;
Silk, J.;
Shustov, B. M.;
Strong, A.;
Tanvir, N.;
Thielemann, F. -K.;
Tibolla, O.;
Tierney, D.;
Trümper, J.;
Varshalovich, D. A.;
Wilms, J.;
Wrochna, G.;
Zdziarski, A.;
Zoglauer, A.
Submitted: 2011-05-06
We propose to perform a continuously scanning all-sky survey from 200 keV to
80 MeV achieving a sensitivity which is better by a factor of 40 or more
compared to the previous missions in this energy range. The Gamma-Ray Imaging,
Polarimetry and Spectroscopy (GRIPS) mission addresses fundamental questions in
ESA's Cosmic Vision plan. Among the major themes of the strategic plan, GRIPS
has its focus on the evolving, violent Universe, exploring a unique energy
window. We propose to investigate $\gamma$-ray bursts and blazars, the
mechanisms behind supernova explosions, nucleosynthesis and spallation, the
enigmatic origin of positrons in our Galaxy, and the nature of radiation
processes and particle acceleration in extreme cosmic sources including pulsars
and magnetars. The natural energy scale for these non-thermal processes is of
the order of MeV. Although they can be partially and indirectly studied using
other methods, only the proposed GRIPS measurements will provide direct access
to their primary photons. GRIPS will be a driver for the study of transient
sources in the era of neutrino and gravitational wave observatories such as
IceCUBE and LISA, establishing a new type of diagnostics in relativistic and
nuclear astrophysics. This will support extrapolations to investigate star
formation, galaxy evolution, and black hole formation at high redshifts.
[2]
oai:arXiv.org:1011.0258 [pdf] - 1041654
HERMES: a high-resolution fibre-fed spectrograph for the Mercator
telescope
Raskin, Gert;
Van Winckel, Hans;
Hensberge, Herman;
Jorissen, Alain;
Lehmann, Holger;
Waelkens, Christoffel;
Avila, Gerardo;
De Cuyper, Jean-Pierre;
Degroote, Pieter;
Dubosson, Rene;
Dumortier, Louis;
Fremat, Yves;
Laux, Uwe;
Michaud, Bernard;
Morren, Johan;
Padilla, Jesus Perez;
Pessemier, Wim;
Prins, Saskia;
Smolders, Kristof;
Van Eck, Sophie;
Winkler, Johannes
Submitted: 2010-11-01
The HERMES high-resolution spectrograph project aims at exploiting the
specific potential of small but flexible telescopes in observational
astrophysics. The optimised optical design of the spectrograph is based on the
well-proven concept of white-pupil beam folding for high-resolution
spectroscopy. In this contribution we present the complete project, including
the spectrograph design and procurement details, the telescope adaptor and
calibration unit, the detector system, as well as the optimised data-reduction
pipeline. We present a detailed performance analysis to show that the
spectrograph performs as specified both in optical quality and in total
efficiency. With a spectral resolution of 85000 (63000 for the low-resolution
fibre), a spectral coverage from 377 to 900nm in a single exposure and a peak
efficiency of 28%, HERMES proves to be an ideal instrument for building up time
series of high-quality data of variable (stellar) phenomena.
[3]
oai:arXiv.org:0801.4801 [pdf] - 9596
GROND - a 7-channel imager
Greiner, J.;
Bornemann, W.;
Clemens, C.;
Deuter, M.;
Hasinger, G.;
Honsberg, M.;
Huber, H.;
Huber, S.;
Krauss, M.;
Krühler, T.;
Yoldaş, A. Küpcü;
Mayer-Hasselwander, H.;
Mican, B.;
Primak, N.;
Schrey, F.;
Steiner, I.;
Szokoly, G.;
Thöne, C. C.;
Yoldaş, A.;
Klose, S.;
Laux, U.;
Winkler, J.
Submitted: 2008-01-30
We describe the construction of GROND, a 7-channel imager, primarily designed
for rapid observations of gamma-ray burst afterglows. It allows simultaneous
imaging in the Sloan g'r'i'z' and near-infrared $JHK$ bands. GROND was
commissioned at the MPI/ESO 2.2m telescope at La Silla (Chile) in April 2007,
and first results of its performance and calibration are presented.
[4]
oai:arXiv.org:astro-ph/0606193 [pdf] - 82633
URAT: astrometric requirements and design history
Submitted: 2006-06-08
The U.S. Naval Observatory Robotic Astrometric Telescope (URAT) project aims
at a highly accurate (5 mas), ground-based, all-sky survey. Requirements are
presented for the optics and telescope for this 0.85 m aperture, 4.5 degree
diameter field-of-view, specialized instrument, which are close to the
capability of the industry. The history of the design process is presented as
well as astrometric performance evaluations of the toleranced, optical design,
with expected wavefront errors included.
[5]
oai:arXiv.org:astro-ph/0512557 [pdf] - 78757
PMAS: The Potsdam Multi Aperture Spectrophotometer. II. The Wide
Integral Field Unit PPak
Submitted: 2005-12-22
PPak is a new fiber-based Integral Field Unit (IFU), developed at the
Astrophysical Institute Potsdam, implemented as a module into the existing PMAS
spectrograph. The purpose of PPak is to provide both an extended field-of-view
with a large light collecting power for each spatial element, as well as an
adequate spectral resolution. The PPak system consists of a fiber bundle with
331 object, 36 sky and 15 calibration fibers. The object and sky fibers collect
the light from the focal plane behind a focal reducer lens. The object fibers
of PPak, each 2.7 arcseconds in diameter, provide a contiguous hexagonal
field-of-view of 74 times 64 arcseconds on the sky, with a filling factor of
60%. The operational wavelength range is from 400 to 900nm. The PPak-IFU,
together with the PMAS spectrograph, are intended for the study of extended,
low surface brightness objects, offering an optimization of total
light-collecting power and spectral resolution. This paper describes the
instrument design, the assembly, integration and tests, the commissioning and
operational procedures, and presents the measured performance at the telescope.
[6]
oai:arXiv.org:astro-ph/0509387 [pdf] - 75969
NAHUAL: A cool spectrograph for planets of ultra-cool objects
Submitted: 2005-09-14
We present the status of an ongoing study to built a a high resolution near
infrared Echelle spectrograph (NAHUAL) for the 10.4-m-Gran Telescopio Canarias
(GTC) which will be especially optimised for planet searches by means of high
precision radial velocity measurements. We show that infrared radial velocity
programs are particularly suitable to search for planets very low mass stars
and brown dwarfs, as well as active stars. The goal of NAHUAL is to reach an
accuracy of the radial velocity measurement of a few m/s, which would allow the
detection of planets with a few earth-masses orbiting low-mass stars and brown
dwarfs. It is planed that NAHUAL covers simultaneously the full wavelength
range in the J, H, and K-band, and will also serve as a general purpose high
resolution near infrared spectrograph of the GTC. The planed instrument will
have a resolution of R=50,000 with a 0.175 arcsec slit, and an AO-system. An
absorption cell will serve as a simultaneous wavelength reference.
[7]
oai:arXiv.org:astro-ph/0502581 [pdf] - 71372
PMAS, the Potsdam Multi-Aperture Spectrophotometer. I. Design,
Manufacture, and Performance
Roth, M. M.;
Kelz, A.;
Fechner, T.;
Hahn, T.;
Bauer, S. -M.;
Becker, T.;
Boehm, P.;
Christensen, L.;
Dionies, F.;
Paschke, J.;
Popow, E.;
Wolter, D.;
Schmoll, J.;
Laux, U.;
Altmann, W.
Submitted: 2005-02-28
We describe the design, manufacture, commissioning, and performance of PMAS,
the Potsdam Multi-Aperture Spectrophotometer. PMAS is a dedicated integral
field spectrophotometer, optimized to cover the optical wavelength regime of
0.35--1um. It is based on the lens array -- fiber bundle principle of
operation. The instrument employs an all-refractive fiber spectrograph, built
with CaF2 optics, to provide good transmission and high image quality over the
entire nominal wavelength range. A set of user-selectable reflective gratings
provides low to medium spectral resolution in first order of approx. 1.5, 3.2,
and 7 A, depending on the groove density (1200, 600, 300 gr/mm). While the
standard integral field unit (IFU) uses a 16x16 element lens array, which
provides seeing-limited sampling in a relatively small field-of-view (FOV) in
one of three magnifications (8x8, 12x12, or 16x16 arcsec^2, respectively), a
recently retrofitted bare fiber bundle IFU (PPak) expands the FOV to a
hexagonal area with a footprint of 65x74 arcsec^2. Other special features
include a cryogenic CCD camera for field acquisition and guiding, a nod-shuffle
mode for beam switching and improved sky background subtraction, and a scanning
Fabry-Perot etalon in combination with the standard IFU (PYTHEAS mode). PMAS
was initially designed and built as an experimental traveling instrument with
optical interfaces to various telescopes (Calar Alto 3.5m, ESO-VLT, LBT). It is
offered as a common user instrument at Calar Alto under contract with MPIA
Heidelberg since 2002.
[8]
oai:arXiv.org:astro-ph/0304288 [pdf] - 56196
Statistical Test of Optical Fibers for use in PMAS, the Potsdam
Multi-Aperture Spectrophotometer
Submitted: 2003-04-15
Focal ratio degradation measurements of optical fibers for the PMAS integral
field instrument have been performed using the Photometric Testbench of the
Potsdam Astrophysical Institute (AIP). An effort has been made to obtain
sufficiently large statistical samples of individual fiber measurements. The
optimization of the measurement process has made it possible to study
quantitatively the effects of different coupling methods (air--glass vs.\
immersion) and of imperfections like defocus, lateral displacement, and angular
misalignment. Furthermore, the effects of mechanical stress on focal ratio
degradation have been investigated, confirming the presumed cause of modal
noise which is known to limit the maximum signal-to-noise one can achieve with
fiber-coupled echelle spectrographs.