sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Laurenti, G.

Normalized to: Laurenti, G.

7 article(s) in total. 90 co-authors, from 1 to 6 common article(s). Median position in authors list is 22,0.

[1]  oai:arXiv.org:0801.3250  [pdf] - 1579278
The RICH detector of the AMS-02 experiment: status and physics prospects
Comments: 5 pages. Contribution to the 10th ICATPP Conference on Astroparticle, Particle, Space Physics, Detectors and Medical Physics Applications (Como 2007). Presenter: Rui Pereira
Submitted: 2008-01-21
The Alpha Magnetic Spectrometer (AMS), whose final version AMS-02 is to be installed on the International Space Station (ISS) for at least 3 years, is a detector designed to measure charged cosmic ray spectra with energies up to the TeV region and with high energy photon detection capability up to a few hundred GeV. It is equipped with several subsystems, one of which is a proximity focusing RICH detector with a dual radiator (aerogel+NaF) that provides reliable measurements for particle velocity and charge. The assembly and testing of the AMS RICH is currently being finished and the full AMS detector is expected to be ready by the end of 2008. The RICH detector of AMS-02 is presented. Physics prospects are briefly discussed.
[2]  oai:arXiv.org:0709.2154  [pdf] - 4935
The AMS-RICH velocity and charge reconstruction
Comments: Contribution to the ICRC07, Merida, Mexico (2007); Presenter: F. Barao
Submitted: 2007-09-13
The AMS detector, to be installed on the International Space Station, includes a Ring Imaging Cerenkov detector with two different radiators, silica aerogel (n=1.05) and sodium fluoride (n=1.334). This detector is designed to provide very precise measurements of velocity and electric charge in a wide range of cosmic nuclei energies and atomic numbers. The detector geometry, in particular the presence of a reflector for acceptance purposes, leads to complex Cerenkov patterns detected in a pixelized photomultiplier matrix. The results of different reconstruction methods applied to test beam data as well as to simulated samples are presented. To ensure nominal performances throughout the flight, several detector parameters have to be carefully monitored. The algorithms developed to fulfill these requirements are presented. The velocity and charge measurements provided by the RICH detector endow the AMS spectrometer with precise particle identification capabilities in a wide energy range. The expected performances on light isotope separation are discussed.
[3]  oai:arXiv.org:astro-ph/0603852  [pdf] - 81061
The Ring Imaging Cherenkov detector (RICH) of the AMS experiment
Comments: 29th International Conference on Cosmic Rays (Pune, India)
Submitted: 2006-03-31
The Alpha Magnetic Spectrometer (AMS) experiment to be installed on the International Space Station (ISS) will be equipped with a proximity focusing Ring Imaging Cherenkov (RICH) detector for measuring the electric charge and velocity of the charged cosmic particles. A RICH prototype consisting of 96 photomultiplier units, including a piece of the conical reflector, was built and its performance evaluated with ion beam data. Preliminary results of the in-beam tests performed with ion fragments resulting from collisions of a 158 GeV/c/nuc primary beam of Indium ions (CERN SPS) on a Pb target are reported. The collected data included tests to the final front-end electronics and to different aerogel radiators. Cherenkov rings for a large range of charged nuclei and with reflected photons were observed. The data analysis confirms the design goals. Charge separation up to Fe and velocity resolution of the order of 0.1% for singly charged particles are obtained.
[4]  oai:arXiv.org:astro-ph/0306224  [pdf] - 57305
The AMS-02 RICH Imager Prototype - In-Beam Tests with 20 GeV/c per Nucleon Ions -
Comments: 4 pages, contribution to the ICRC 2003
Submitted: 2003-06-11
A prototype of the AMS Cherenkov imager (RICH) has been tested at CERN by means of a low intensity 20 GeV/c per nucleon ion beam obtained by fragmentation of a primary beam of Pb ions. Data have been collected with a single beam setting, over the range of nuclear charges 2<Z<~45 in various beam conditions and using different radiators. The charge Z and velocity beta resolutions have been measured.
[5]  oai:arXiv.org:astro-ph/0206021  [pdf] - 49652
The AMS-02 Time of Flight System
Comments: 6 pages, 7 figures. Talk given at the ``First International Conference on Particle and Fundamental Physics in Space'', La Biodola, Isola d'Elba (Italy), 14 -- 19 May 2002. To be published by Nuclear Physics B - Proceedings Supplement. Sep. 13, 2002: added "Conclusion" section
Submitted: 2002-06-03, last modified: 2002-09-13
The Time-of-Flight (TOF) system of the AMS detector gives the fast trigger to the read out electronics and measures velocity, direction and charge of the crossing particles. The first version of the detector (called AMS-01) has flown in 1998 aboard of the shuttle Discovery for a 10 days test mission, and collected about $10^8$ events. The new version (called AMS-02) will be installed on the International Space Station and will operate for at least three years, collecting roughly $10^{10}$ Cosmic Ray (CR) particles. The TOF system of AMS-01 successfully operated during the test mission, obtaining a time resolution of 120 ps for protons and better for other CR ions. The TOF system of AMS-02 will be different due to the strong fringing magnetic field and weight constraints
[6]  oai:arXiv.org:astro-ph/0111480  [pdf] - 46246
The AMS-01 Time of Flight System
Comments: 5 pages, 4 figures. Presented at the 7th Int. Conf. on Advanced Technology and Particle Physics, Villa Olmo, Como (Italy), 15-19 October 2001
Submitted: 2001-11-26
The Time-of-Flight (TOF) system of the AMS detector gives the fast trigger to the read out electronics and measures velocity, direction and charge of the crossing particles. The first version of the detector (called AMS-01) has flown in 1998 aboard of the shuttle Discovery for a 10 days test mission, and collected about $10^8$ events. The new version (called AMS-02) will be installed on the International Space Station on March 2004 and will operate for at least three years, collecting roughly $10^{10}$ Cosmic Rays (CR) particles. The TOF system of AMS-01 successfully operated during the test mission, obtaining a trigger efficiency better than 99.9% and a time resolution of 120 ps for protons and better for other CR ions. In addition, the TOF system was able to separate protons from all the other CR nuclei within 1% and to distinguish between downward and upward crossing particles within at most $10^{-8}$.
[7]  oai:arXiv.org:astro-ph/0010242  [pdf] - 387034
The AMS-01 Aerogel Threshold Cherenkov counter
Comments: 28 pages, 13 figures, submitted to Nucl. Instrum. Methods A
Submitted: 2000-10-12
The Alpha Magnetic Spectrometer in a precursor version (AMS-01), was flown in June 1998 on a 51.6 degrees orbit and at altitudes ranging between 320 and 390 km, on board of the space shuttle Discovery (flight STS-91). AMS-01 included an Aerogel Threshold Cherenkov counter (ATC) to separate antiprotons from electrons and positrons from protons, for momenta below 3.5 GeV/c. This paper presents a description of the ATC counter and reports on its performances during the flight STS-91.