Normalized to: Lathrop, A.
[1]
oai:arXiv.org:2004.04266 [pdf] - 2077337
Interplay between phonon downconversion efficiency, density of states at
Fermi energy, and intrinsic energy resolution for microwave kinectic
inductance detectors
Submitted: 2020-04-06
Microwave Kinetic Inductance detectors (MKIDs) have been recognized as a
powerful new tool for single photon detection. These highly multiplexed
superconducting devices give timing and energy measurement for every detected
photon. However, the full potential of MKID single photon spectroscopy has not
been reached , the achieved energy resolution is lower than expected from first
principles. Here, we study the efficiency in the phonon downconversion process
following the absorption of energetic photons in MKIDs. Assuming previously
published material properties, we measure an average downconversion efficiency
for three TiN resonators is $\eta$=0.14. We discuss how this efficiency can
impact the intrinsic energy resolution of MKID, and how any uncertainty in the
unknown density of electron states at the Fermi energy directly affects the
efficiency estimations.
[2]
oai:arXiv.org:1702.00873 [pdf] - 1581372
A measurement of the ionization efficiency of nuclear recoils in silicon
Izraelevitch, F.;
Amidei, D.;
Aprahamian, A.;
Arcos-Olalla, R.;
Cancelo, G.;
Casarella, C.;
Chavarria, A. E.;
Collon, P.;
Estrada, J.;
Moroni, G. Fernández;
Guardincerri, Y.;
Gutiérrez, G.;
Gyurjinyan, A.;
Kavner, A.;
Kilminster, B.;
Lathrop, A.;
Liao, J.;
Liu, Q.;
López, M.;
Molina, J.;
Privitera, P.;
Reyes, M. A.;
Scarpine, V.;
Siegl, K.;
Smith, M.;
Strauss, S.;
Tan, W.;
Tiffenberg, J.;
Villanueva, L.
Submitted: 2017-02-02, last modified: 2017-07-04
We have measured the ionization efficiency of silicon nuclear recoils with
kinetic energy between 1.8 and 20 keV. We bombarded a silicon-drift diode with
a neutron beam to perform an elastic-scattering experiment. A broad-energy
neutron spectrum was used and the nuclear recoil energy was reconstructed using
a measurement of the time of flight and scattering angle of the scattered
neutron. The overall trend of the results of this work is well described by the
theory of Lindhard et al. above 4 keV of recoil energy. Below this energy, the
presented data shows a deviation from the model. The data indicates a faster
drop than the theory prediction at low energies.
[3]
oai:arXiv.org:1504.02900 [pdf] - 1300165
The Dark Energy Camera
Flaugher, B.;
Diehl, H. T.;
Honscheid, K.;
Abbott, T. M. C.;
Alvarez, O.;
Angstadt, R.;
Annis, J. T.;
Antonik, M.;
Ballester, O.;
Beaufore, L.;
Bernstein, G. M.;
Bernstein, R. A.;
Bigelow, B.;
Bonati, M.;
Boprie, D.;
Brooks, D.;
Buckley-Geer, E. J.;
Campa, J.;
Cardiel-Sas, L.;
Castander, F. J.;
Castilla, J.;
Cease, H.;
Cela-Ruiz, J. M.;
Chappa, S.;
Chi, E.;
Cooper, C.;
da Costa, L. N.;
Dede, E.;
Derylo, G.;
DePoy, D. L.;
de Vicente, J.;
Doel, P.;
Drlica-Wagner, A.;
Eiting, J.;
Elliott, A. E.;
Emes, J.;
Estrada, J.;
Neto, A. Fausti;
Finley, D. A.;
Flores, R.;
Frieman, J.;
Gerdes, D.;
Gladders, M. D.;
Gregory, B.;
Gutierrez, G. R.;
Hao, J.;
Holland, S. E.;
Holm, S.;
Huffman, D.;
Jackson, C.;
James, D. J.;
Jonas, M.;
Karcher, A.;
Karliner, I.;
Kent, S.;
Kessler, R.;
Kozlovsky, M.;
Kron, R. G.;
Kubik, D.;
Kuehn, K.;
Kuhlmann, S.;
Kuk, K.;
Lahav, O.;
Lathrop, A.;
Lee, J.;
Levi, M. E.;
Lewis, P.;
Li, T. S.;
Mandrichenko, I.;
Marshall, J. L.;
Martinez, G.;
Merritt, K. W.;
Miquel, R.;
Munoz, F.;
Neilsen, E. H.;
Nichol, R. C.;
Nord, B.;
Ogando, R.;
Olsen, J.;
Palio, N.;
Patton, K.;
Peoples, J.;
Plazas, A. A.;
Rauch, J.;
Reil, K.;
Rheault, J. -P.;
Roe, N. A.;
Rogers, H.;
Roodman, A.;
Sanchez, E.;
Scarpine, V.;
Schindler, R. H.;
Schmidt, R.;
Schmitt, R.;
Schubnell, M.;
Schultz, K.;
Schurter, P.;
Scott, L.;
Serrano, S.;
Shaw, T. M.;
Smith, R. C.;
Soares-Santos, M.;
Stefanik, A.;
Stuermer, W.;
Suchyta, E.;
Sypniewski, A.;
Tarle, G.;
Thaler, J.;
Tighe, R.;
Tran, C.;
Tucker, D.;
Walker, A. R.;
Wang, G.;
Watson, M.;
Weaverdyck, C.;
Wester, W.;
Woods, R.;
Yanny, B.
Submitted: 2015-04-11
The Dark Energy Camera is a new imager with a 2.2-degree diameter field of
view mounted at the prime focus of the Victor M. Blanco 4-meter telescope on
Cerro Tololo near La Serena, Chile. The camera was designed and constructed by
the Dark Energy Survey Collaboration, and meets or exceeds the stringent
requirements designed for the wide-field and supernova surveys for which the
collaboration uses it. The camera consists of a five element optical corrector,
seven filters, a shutter with a 60 cm aperture, and a CCD focal plane of 250
micron thick fully-depleted CCDs cooled inside a vacuum Dewar. The 570 Mpixel
focal plane comprises 62 2kx4k CCDs for imaging and 12 2kx2k CCDs for guiding
and focus. The CCDs have 15 microns x15 microns pixels with a plate scale of
0.263 arc sec per pixel. A hexapod system provides state-of-the-art focus and
alignment capability. The camera is read out in 20 seconds with 6-9 electrons
readout noise. This paper provides a technical description of the camera's
engineering, construction, installation, and current status.