Normalized to: Lara, D.
[1]
oai:arXiv.org:1509.05270 [pdf] - 1278881
An investigation of the Eigenvalue Calibration Method (ECM) using GASP
for non-imaging and imaging detectors
Submitted: 2015-09-17
Polarised light from astronomical targets can yield a wealth of information
about their source radiation mechanisms, and about the geometry of the
scattered light regions. Optical observations, of both the linear and circular
polarisation components, have been impeded due to non-optimised
instrumentation. The need for suitable observing conditions and the
availability of luminous targets are also limiting factors. GASP uses division
of amplitude polarimeter (DOAP) (Compain and Drevillon) to measure the four
components of the Stokes vector simultaneously, which eliminates the
constraints placed upon the need for moving parts during observation, and
offers a real-time complete measurement of polarisation. Results from the GASP
calibration are presented in this work for both a 1D detector system, and a
pixel-by-pixel analysis on a 2D detector system. Following Compain et al. we
use the Eigenvalue Calibration Method (ECM) to measure the polarimetric
limitations of the instrument for each of the two systems. Consequently, the
ECM is able to compensate for systematic errors introduced by the calibration
optics, and it also accounts for all optical elements of the polarimeter in the
output. Initial laboratory results of the ECM are presented, using APD
detectors, where errors of 0.2% and 0.1{\deg} were measured for the degree of
linear polarisation and polarisation angle respectively. Channel-to-channel
image registration is an important aspect of 2-D polarimetry. We present our
calibration results of the measured Mueller matrix of each sample, used by the
ECM. A set of Zenith flat-field images were recorded during an observing
campaign at the Palomar 200 inch telescope in November 2012. From these we show
the polarimetric errors from the spatial polarimetry indicating both the
stability and absolute accuracy of GASP.
[2]
oai:arXiv.org:1305.6825 [pdf] - 1171658
The Galway Astronomical Stokes Polarimeter: An All-Stokes Optical
Polarimeter with Ultra-High Time Resolution
Submitted: 2013-05-29
Many astronomical objects emit polarised light, which can give information
both about their source mechanisms, and about (scattering) geometry in their
source regions. To date (mostly) only the linearly polarised components of the
emission have been observed in stellar sources. Observations have been
constrained because of instrumental considerations to periods of excellent
observing conditions, and to steady, slowly or periodically-varying sources.
This leaves a whole range of interesting objects beyond the range of
observation at present. The Galway Astronomical Stokes Polarimeter (GASP) has
been developed to enable us to make observations on these very sources. GASP
measures the four components of the Stokes Vector simultaneously over a broad
wavelength range 400-800nm., with a time resolution of order microseconds given
suitable detectors and a bright source - this is possible because the optical
design contains no moving or modulating components. The initial design of GASP
is presented and we include some preliminary observational results
demonstrating that components of the Stokes vector can be measured to <1% in
conditions of poor atmospheric stability. Issues of efficiency and stability
are addressed. An analysis of suitable astronomical targets, demanding the