Normalized to: Lankshear, A.
[1]
oai:arXiv.org:astro-ph/0606137 [pdf] - 329112
Performance of AAOmega: the AAT multi-purpose fibre-fed spectrograph
Sharp, R.;
Saunder, W.;
Smith, G.;
Churilov, V.;
Correll, D.;
Dawson, J.;
Farrel, T.;
Frost, G.;
Haynes, R.;
Heald, R.;
Lankshear, A.;
Mayfield, D.;
Waller, L.;
Whittard, D.
Submitted: 2006-06-06
AAOmega is the new spectrograph for the 2dF fibre-positioning system on the
Anglo-Australian Telescope. It is a bench-mounted, double-beamed design, using
volume phase holographic (VPH) gratings and articulating cameras. It is fed by
392 fibres from either of the two 2dF field plates, or by the 512 fibre SPIRAL
integral field unit (IFU) at Cassegrain focus. Wavelength coverage is 370 to
950nm and spectral resolution 1,000-8,000 in multi-Object mode, or 1,500-10,000
in IFU mode. Multi-object mode was commissioned in January 2006 and the IFU
system will be commissioned in June 2006.
The spectrograph is located off the telescope in a thermally isolated room
and the 2dF fibres have been replaced by new 38m broadband fibres. Despite the
increased fibre length, we have achieved a large increase in throughput by use
of VPH gratings, more efficient coatings and new detectors - amounting to a
factor of at least 2 in the red. The number of spectral resolution elements and
the maximum resolution are both more than doubled, and the stability is an
order of magnitude better.
The spectrograph comprises: an f/3.15 Schmidt collimator, incorporating a
dichroic beam-splitter; interchangeable VPH gratings; and articulating red and
blue f/1.3 Schmidt cameras. Pupil size is 190mm, determined by the competing
demands of cost, obstruction losses, and maximum resolution. A full suite of
VPH gratings has been provided to cover resolutions 1,000 to 7,500, and up to
10,000 at particular wavelengths.
[2]
oai:arXiv.org:astro-ph/0202175 [pdf] - 47669
The Anglo-Australian Observatory's 2dF Facility
Lewis, I. J.;
Cannon, R. D.;
Taylor, K.;
Glazebrook, K.;
Bailey, J. A.;
Baldry, I. K.;
Barton, J. R.;
Bridges, T. J.;
Dalton, G. B.;
Farrell, T. J.;
Gray, P. M.;
Lankshear, A.;
McCowage, C.;
Parry, I. R.;
Sharples, R. M.;
Shortridge, K.;
Smith, G. A.;
Stevenson, J.;
Straede, J. O.;
Waller, L. G.;
Whittard, J. D.;
Wilcox, J. K.;
Willis, K. C.
Submitted: 2002-02-08
The 2dF (Two-degree Field) facility at the prime focus of the
Anglo-Australian Telescope provides multiple object spectroscopy over a 2
degree field of view. Up to 400 target fibres can be independently positioned
by a complex robot. Two spectrographs provide spectra with resolutions of
between 500 and 2000, over wavelength ranges of 440nm and 110nm respectively.
The 2dF facility began routine observations in 1997.
2dF was designed primarily for galaxy redshift surveys and has a number of
innovative features. The large corrector lens incorporates an atmospheric
dispersion compensator, essential for wide wavelength coverage with small
diameter fibres. The instrument has two full sets of fibres on separate field
plates, so that re-configuring can be done in parallel with observing. The
robot positioner places one fibre every 6 seconds, to a precision of 0.3 arcsec
(20micron) over the full field. All components of 2dF, including the
spectrographs, are mounted on a 5-m diameter telescope top-end ring for ease of
handling and to keep the optical fibres short in order to maximise UV
throughput . There is a pipeline data reduction system which allows each data
set to be fully analysed while the next field is being observed.
In this paper we provide the historical background to the 2dF facility, the
design philosophy, a full technical description and a summary of the
performance of the instrument. We also briefly review its scientific
applications and possible future developments.