Normalized to: Lancelot, J.
[1]
oai:arXiv.org:2002.01159 [pdf] - 2069029
Additional Calibration of the Ultra-Violet Imaging Telescope on board
AstroSat
Tandon, S. N.;
Postma, J.;
Joseph, P.;
Devaraj, A.;
Subramaniam, A;
Barve, I. V.;
George, K.;
Ghosh, S. K.;
Girish, V.;
Hutchings, J. B.;
Kamath, P. U.;
Kathiravan, S.;
Kumar, A.;
Lancelot, J. P.;
Leahy, D.;
Mahesh, P. K.;
Mohan, R.;
Nagabhushana, S.;
Pati, A. K.;
Rao, N. Kameswara;
Sankarasubramanian, K.;
Sriram, S.;
Stalin, C. S.
Submitted: 2020-02-04
Results of the initial calibration of the Ultra-Violet Imaging Telescope
(UVIT) were reported earlier by Tandon et al. (2017). The results reported
earlier were based on the ground calibration as well as the first observations
in orbit. Some additional data from the ground calibration and data from more
in-orbit observations have been used to improve the results. In particular,
extensive new data from in-orbit observations have been used to obtain (a) new
photometric calibration which includes (i) zero-points (ii) flat fields (iii)
saturation, (b) sensitivity variations (c) spectral calibration for the near
Ultra Violet (NUV; 2000 - 3000 Angstroms) and far Ultra-Violet (FUV; 1300 -
1800 Angstroms) gratings, (d) point spread function and (e) astrometric
calibration which included distortion. Data acquired over the last three years
show continued good performance of UVIT with no reduction in sensitivity in
both the UV channels.
[2]
oai:arXiv.org:1705.03715 [pdf] - 1583290
In-orbit Calibrations of the Ultra-Violet Imaging Telescope
Tandon, S. N.;
Subramaniam, Annapurni;
Girish, V.;
Postma, J.;
Sankarasubramanian, K.;
Sriram, S.;
Stalin, C. S.;
Mondal, C.;
Joseph, S. Sahu P.;
Hutchings, J.;
Ghosh, S. K.;
Barve, I. V.;
George, K.;
Kamath, P. U.;
Kathiravan, S.;
Kumar, A.;
Lancelot, J. P.;
Leahy, D.;
Mahesh, P. K.;
Mohan, R.;
Nagabhushana, S.;
Pati, A. K.;
Rao, N. Kameswara;
Sreedhar, Y. H.;
Sreekumar, P.
Submitted: 2017-05-10, last modified: 2017-08-05
The Ultra-Violet Imaging Telescope (UVIT) is one of the payloads in ASTROSAT,
the first Indian Space Observatory. The UVIT instrument has two 375mm
telescopes: one for the far-ultraviolet (FUV) channel (1300--1800\AA), and the
other for the near-ultraviolet (NUV) channel (2000--3000\AA) and the visible
(VIS) channel (3200--5500\AA). UVIT is primarily designed for simultaneous
imaging in the two ultraviolet channels with spatial resolution better than 1.8
arcsec, along with provision for slit-less spectroscopy in the NUV and FUV
channels.The results of in-orbit calibrations of UVIT are presented in this
paper.
[3]
oai:arXiv.org:1612.00612 [pdf] - 1580790
In-orbit Performance of UVIT and First Results
Tandon, S. N.;
Hutchings, J. B.;
Ghosh, S. K.;
Subramaniam, A.;
Koshy, G.;
Girish, V.;
Kamath, P. U.;
Kathiravan, s.;
Kumar, A.;
Lancelot, J. P.;
Mahesh, P. K.;
Mohan, R.;
Murthy, J.;
Nagabhushana, S.;
A, A. K. Pati;
Postma, J.;
Rao, N. Kameswara;
Sankarasubramanian, K.;
Sreekumar, P.;
Sriram, S.;
Stalin, C. S.;
Sutaria, F.;
Sreedhar, Y. H.;
Barve, I. V.;
Mondal, C.;
Sahu, S.
Submitted: 2016-12-02
The performance of the ultraviolet telescope (UVIT) on-board ASTROSAT is
reported. The performance in orbit is also compared with estimates made from
the calibrations done on the ground. The sensitivity is found to be within ~15%
of the estimates, and the spatial resolution in the NUV is found to exceed
significantly the design value of 1.8 arcsec and it is marginally better in the
FUV. Images obtained from UVIT are presented to illustrate the details revealed
by the high spatial resolution. The potential of multi-band observations in the
ultraviolet with high spatial resolution is illustrated by some results.
[4]
oai:arXiv.org:1608.03390 [pdf] - 1457585
Full-disk Synoptic Observations of the Chromosphere Using H$_{\alpha}$
Telescope at the Kodaikanal Observatory
Ravindra, B.;
Prabhu, K.;
Rangarajan, K. E.;
Bagare, S. P.;
Jagdev, Singh;
Kemkar, P. M. M.;
Lancelot, J. P.;
Thulasidharen, K. C.;
Gabriel, F.;
Selvendran, R.
Submitted: 2016-08-11
This paper reports on the installation and observations of a new solar
telescope installed on 7th October, 2014 at the Kodaikanal Observatory. The
telescope is a refractive type equipped with a tunable Lyot H$_{\alpha}$
filter. A CCD camera of 2k$\times$2k size makes the image of the Sun with a
pixel size of 1.21$^{\prime\prime}$ pixel$^{-1}$ with a full field-of-view of
41$^{\prime}$. The telescope is equipped with a guiding system which keeps the
image of the Sun within a few pixels throughout the observations. The FWHM of
the Lyot filter is 0.4\AA~and the filter is motorized, capable of scanning the
H$_{\alpha}$ line profile at a smaller step size of 0.01\AA. Partial-disk
imaging covering about 10$^{\prime}$, is also possible with the help of a relay
lens kept in front of the CCD camera. In this paper, we report the detailed
specifications of the telescope, filter unit, its installation, observations
and the procedures we have followed to calibrate and align the data. We also
present preliminary results with this new full-disk telescope.
[5]
oai:arXiv.org:1608.01073 [pdf] - 1521281
In-orbit Performance of UVIT on ASTROSAT
Subramaniam, Annapurni;
Tandon, Shyam N.;
Hutchings, John;
Ghosh, Swarna K.;
George, Koshy;
Girish, V.;
Kamath, P. U.;
Kathiravan, S.;
Kumar, Amit;
Lancelot, J. Paul;
Mahesh, P. K.;
Mohan, Rekhesh;
Murthy, Jayant;
Nagabhushana, S.;
Pati, Ashok K.;
Postma, Joe;
Rao, N. Kameswara;
Sankarasubramanian, Kasiviswanathan;
Sreekumar, P.;
Sriram, S.;
Stalin, Chelliah S.;
Sutaria, Firoza;
Sreedhar, Yuvraj Harsha;
Barve, Indrajit V.;
Mondal, Chayan;
Sahu, Snehalata
Submitted: 2016-08-03
We present the in-orbit performance and the first results from the
ultra-violet Imaging telescope (UVIT) on ASTROSAT. UVIT consists of two
identical 38cm coaligned telescopes, one for the FUV channel (130-180nm) and
the other for the NUV (200-300nm) and VIS (320-550nm) channels, with a field of
view of 28 $arcmin$. The FUV and the NUV detectors are operated in the high
gain photon counting mode whereas the VIS detector is operated in the low gain
integration mode. The FUV and NUV channels have filters and gratings, whereas
the VIS channel has filters. The ASTROSAT was launched on 28th September 2015.
The performance verification of UVIT was carried out after the opening of the
UVIT doors on 30th November 2015, till the end of March 2016 within the
allotted time of 50 days for calibration. All the on-board systems were found
to be working satisfactorily. During the PV phase, the UVIT observed several
calibration sources to characterise the instrument and a few objects to
demonstrate the capability of the UVIT. The resolution of the UVIT was found to
be about 1.4 - 1.7 $arcsec$ in the FUV and NUV. The sensitivity in various
filters were calibrated using standard stars (white dwarfs), to estimate the
zero-point magnitudes as well as the flux conversion factor. The gratings were
also calibrated to estimate their resolution as well as effective area. The
sensitivity of the filters were found to be reduced up to 15\% with respect to
the ground calibrations. The sensitivity variation is monitored on a monthly
basis. UVIT is all set to roll out science results with its imaging capability
with good resolution and large field of view, capability to sample the UV
spectral region using different filters and capability to perform variability
studies in the UV.