Normalized to: Lamy, T.
[1]
oai:arXiv.org:0911.0323 [pdf] - 902277
The case for a directional dark matter detector and the status of
current experimental efforts
Ahlen, S.;
Afshordi, N.;
Battat, J. B. R.;
Billard, J.;
Bozorgnia, N.;
Burgos, S.;
Caldwell, T.;
Carmona, J. M.;
Cebrian, S.;
Colas, P.;
Dafni, T.;
Daw, E.;
Dujmic, D.;
Dushkin, A.;
Fedus, W.;
Ferrer, E.;
Finkbeiner, D.;
Fisher, P. H.;
Forbes, J.;
Fusayasu, T.;
Galan, J.;
Gamble, T.;
Ghag, C.;
Giomataris, I.;
Gold, M.;
Gomez, H.;
Gomez, M. E.;
Gondolo, P.;
Green, A.;
Grignon, C.;
Guillaudin, O.;
Hagemann, C.;
Hattori, K.;
Henderson, S.;
Higashi, N.;
Ida, C.;
Iguaz, F. J.;
Inglis, A.;
Irastorza, I. G.;
Iwaki, S.;
Kaboth, A.;
Kabuki, S.;
Kadyk, J.;
Kallivayalil, N.;
Kubo, H.;
Kurosawa, S.;
Kudryavtsev, V. A.;
Lamy, T.;
Lanza, R.;
Lawson, T. B.;
Lee, A.;
Lee, E. R.;
Lin, T.;
Loomba, D.;
Lopez, J.;
Luzon, G.;
Manobu, T.;
Martoff, J.;
Mayet, F.;
Mccluskey, B.;
Miller, E.;
Miuchi, K.;
Monroe, J.;
Morgan, B.;
Muna, D.;
Murphy, A. St. J.;
Naka, T.;
Nakamura, K.;
Nakamura, M.;
Nakano, T.;
Nicklin, G. G.;
Nishimura, H.;
Niwa, K.;
Paling, S. M.;
Parker, J.;
Petkov, A.;
Pipe, M.;
Pushkin, K.;
Robinson, M.;
Rodriguez, A.;
Rodriguez-Quintero, J.;
Sahin, T.;
Sanderson, R.;
Sanghi, N.;
Santos, D.;
Sato, O.;
Sawano, T.;
Sciolla, G.;
Sekiya, H.;
Slatyer, T. R.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Sugiyama, A.;
Takada, A.;
Takahashi, M.;
Takeda, A.;
Tanimori, T.;
Taniue, K.;
Tomas, A.;
Tomita, H.;
Tsuchiya, K.;
Turk, J.;
Tziaferi, E.;
Ueno, K.;
Vahsen, S.;
Vanderspek, R.;
Vergados, J.;
Villar, J. A.;
Wellenstein, H.;
Wolfe, I.;
Yamamoto, R. K.;
Yegoryan, H.
Submitted: 2009-11-01
We present the case for a dark matter detector with directional sensitivity.
This document was developed at the 2009 CYGNUS workshop on directional dark
matter detection, and contains contributions from theorists and experimental
groups in the field. We describe the need for a dark matter detector with
directional sensitivity; each directional dark matter experiment presents their
project's status; and we close with a feasibility study for scaling up to a one
ton directional detector, which would cost around $150M.
[2]
oai:arXiv.org:0810.1137 [pdf] - 17161
Ionization Quenching Factor Measurement of Helium 4
Submitted: 2008-10-07
The ionization quenching factor (IQF) is defined as the fraction of energy
released by a recoil in a medium through ionization compared with its total
kinetic energy. At low energies, in the range of a few keV, the ionization
produced in a medium falls rapidly and systematic measurements are needed. We
report measurements carried out at such low energies as a function of the
pressure in He4 at 350, 700, 1000 and 1300 mbar. In order to produce a nucleus
moving with a controlled energy in the detection volume, we have developed an
Electron Cyclotron Resonance Ion Source (ECRIS) coupled to an ionization
chamber by a differential pumping. The quenching factor of He4 has been
measured for the first time down to 1 keV recoil energies. An important
deviation with respect to the phenomenological calculations has been found
allowing an estimation of the scintillation produced in He4 as a function of
pressure. The variation of the IQF as a function of the percentage of
isobutane, used as quencher, is also presented.
[3]
oai:arXiv.org:astro-ph/0703310 [pdf] - 90119
MIMAC : A Micro-TPC Matrix of Chambers for direct detection of Wimps
Submitted: 2007-03-13
The project of a micro-TPC matrix of chambers of He3 and CF4 for direct
detection of non-baryonic dark matter is outlined. The privileged properties of
He3 are highlighted. The double detection (ionization - projection of tracks)
will assure the electron-recoil discrimination. The complementarity of MIMAC
for supersymmetric dark matter search with respect to other experiments is
illustrated.The modular character of the detector allows to have different
gases to get A-dependence. The pressure degreee of freedom gives the
possibility to work at high and low pressures. The low pressure regime gives
the possibility to get the directionality of the tracks. The first measurements
of ionization at very few keVs for He3 in CF4 gas are described.
[4]
oai:arXiv.org:astro-ph/0701230 [pdf] - 1510614
MIMAC-He3 : MIcro-tpc MAtrix of Chambers of He3
Submitted: 2007-01-09
The project of a micro-TPC matrix of chambers of He3 for direct detection of
non-baryonic dark matter is outlined. The privileged properties of He3 are
highlighted. The double detection (ionization - projection of tracks) will
assure the electron-recoil discrimination. The complementarity of MIMAC-He3 for
supersymmetric dark matter search with respect to other experiments is
illustrated. The modular character of the detector allows to have different
gases to get A-dependence. The pressure degreee of freedom gives the
possibility to work at high and low pressure. The low pressure regime gives the
possibility to get the directionality of the tracks. The first measurements of
ionization at very few keVs for He3 in He4 gas are described.