Normalized to: Lamoreaux, S.
[1]
oai:arXiv.org:2003.08510 [pdf] - 2124673
An improved analysis framework for axion dark matter searches
Palken, D. A.;
Brubaker, B. M.;
Malnou, M.;
Kenany, S. Al;
Backes, K. M.;
Cahn, S. B.;
Gurevich, Y. V.;
Lamoreaux, S. K.;
Lewis, S. M.;
Maruyama, R. H.;
Rapidis, N. M.;
Root, J. R.;
Simanovskaia, M.;
Shokair, T. M.;
Singh, Sukhman;
Speller, D. H.;
Urdinaran, I.;
van Bibber, K.;
Zhong, L.;
Lehnert, K. W.
Submitted: 2020-03-18, last modified: 2020-06-13
In experiments searching for axionic dark matter, the use of the standard
threshold-based data analysis discards valuable information. We present a
Bayesian analysis framework that builds on an existing processing protocol to
extract more information from the data of coherent axion detectors such as
operating haloscopes. The analysis avoids logical subtleties that accompany the
standard analysis framework and enables greater experimental flexibility on
future data runs. Performing this analysis on the existing data from the
HAYSTAC experiment, we find improved constraints on the axion-photon coupling
$g_\gamma$ while also identifying the most promising regions of parameter space
within the $23.15$--$24.0$ $\mu$eV mass range. A comparison with the standard
threshold analysis suggests a $36\%$ improvement in scan rate from our
analysis, demonstrating the utility of this framework for future axion
haloscope analyses.
[2]
oai:arXiv.org:1706.08388 [pdf] - 1606998
The HAYSTAC Axion Search Analysis Procedure
Submitted: 2017-06-26, last modified: 2017-12-22
We describe in detail the analysis procedure used to derive the first limits
from the Haloscope at Yale Sensitive to Axion CDM (HAYSTAC), a microwave cavity
search for cold dark matter (CDM) axions with masses above $20\ \mu\text{eV}$.
We have introduced several significant innovations to the axion search analysis
pioneered by the Axion Dark Matter eXperiment (ADMX), including optimal
filtering of the individual power spectra that constitute the axion search
dataset and a consistent maximum likelihood procedure for combining and
rebinning these spectra. These innovations enable us to obtain the axion-photon
coupling $|g_\gamma|$ excluded at any desired confidence level directly from
the statistics of the combined data.
[3]
oai:arXiv.org:1706.03676 [pdf] - 1584550
Recent Technical Improvements to the HAYSTAC Experiment
Submitted: 2017-06-12, last modified: 2017-08-07
We report here several technical improvements to the HAYSTAC (Haloscope at
Yale Sensitive To Axion Cold dark matter) that have improved operational
efficiency, sensitivity, and stability.
[4]
oai:arXiv.org:1611.07123 [pdf] - 1537416
Design and Operational Experience of a Microwave Cavity Axion Detector
for the 20-100 micro-eV Range
Kenany, S. Al;
Anil, M. A.;
Backes, K. M.;
Brubaker, B. M.;
Cahn, S. B.;
Carosi, G.;
Gurevich, Y. V.;
Kindel, W. F.;
Lamoreaux, S. K.;
Lehnert, K. W.;
Lewis, S. M.;
Malnou, M.;
Palken, D. A.;
Rapidis, N. M.;
Root, J. R.;
Simanovskaia, M.;
Shokair, T. M.;
Urdinaran, I.;
van Bibber, K. A.;
Zhong, L.
Submitted: 2016-11-21, last modified: 2017-02-22
We describe a dark matter axion detector designed, constructed, and operated
both as an innovation platform for new cavity and amplifier technologies and as
a data pathfinder in the $5 - 25$ GHz range ($\sim20-100\: \mu$eV). The
platform is small but flexible to facilitate the development of new microwave
cavity and amplifier concepts in an operational environment. The experiment has
recently completed its first data production; it is the first microwave cavity
axion search to deploy a Josephson parametric amplifier and a dilution
refrigerator to achieve near-quantum limited performance.
[5]
oai:arXiv.org:1610.02580 [pdf] - 1531959
First results from a microwave cavity axion search at 24 micro-eV
Brubaker, B. M.;
Zhong, L.;
Gurevich, Y. V.;
Cahn, S. B.;
Lamoreaux, S. K.;
Simanovskaia, M.;
Root, J. R.;
Lewis, S. M.;
Kenany, S. Al;
Backes, K. M.;
Urdinaran, I.;
Rapidis, N. M.;
Shokair, T. M.;
van Bibber, K. A.;
Palken, D. A.;
Malnou, M.;
Kindel, W. F.;
Anil, M. A.;
Lehnert, K. W.;
Carosi, G.
Submitted: 2016-10-08, last modified: 2017-02-09
We report on the first results from a new microwave cavity search for dark
matter axions with masses above $20~\mu\text{eV}$. We exclude axion models with
two-photon coupling $g_{a\gamma\gamma} \gtrsim 2\times10^{-14}~\text{GeV}^{-1}$
over the range $23.55~\mu\text{eV} < m_a < 24.0~\mu\text{eV}$. These results
represent two important achievements. First, we have reached cosmologically
relevant sensitivity an order of magnitude higher in mass than any existing
limits. Second, by incorporating a dilution refrigerator and Josephson
parametric amplifier, we have demonstrated total noise approaching the standard
quantum limit for the first time in an axion search.
[6]
oai:arXiv.org:1602.00039 [pdf] - 1350800
Experimental Searches for the Axion and Axion-like Particles
Submitted: 2016-01-29
Four decades after its prediction, the axion remains the most compelling
solution to the Strong-CP problem and a well-motivated dark matter candidate,
inspiring a host of elegant and ultrasensitive experiments based on
axion-photon mixing. This report reviews the experimental situation on several
fronts. The microwave cavity experiment is making excellent progress in the
search for dark matter axions in the microelectronvolt range and may be
plausibly extended up to 100 mu eV. Within the past several years however, it
has been realized that axions are pervasive throughout string theories, but
with masses that fall naturally in the nanoelectronvolt range, for which a
NMR-based search is under development. Searches for axions emitted from the
Sun's burning core, and purely laboratory experiments based on photon
regeneration have both made great strides in recent years, with ambitious
projects proposed for the coming decade. Each of these campaigns has pushed the
state of the art in technology, enabling large gains in sensitivity and mass
reach. Furthermore each modality has also been exploited to search for more
generalized axion-like particles, that will also be discussed in this report.
We are hopeful, even optimistic, that the next review of the subject will
concern the discovery of the axion, its properties, and its exploitation as a
probe of early universe cosmology and structure formation.
[7]
oai:arXiv.org:1404.0004 [pdf] - 1292110
Stabilizing a Fabry-Perot etalon to 3 cm/s for spectrograph calibration
Submitted: 2014-03-31
We present a method of frequency stabilizing a broadband etalon that can
serve as a high-precision wavelength calibrator for an Echelle spectrograph.
Using a laser to probe the Doppler-free saturated absorption of the rubidium D2
line, we stabilize one etalon transmission peak directly to the rubidium
frequency. The rubidium transition is an established frequency standard and has
been used to lock lasers to fractional stabilities of $<10^{-12}$, a level of
accuracy far exceeding the demands of radial velocity (RV) searches for
exoplanets. We describe a simple setup designed specifically for use at an
observatory and demonstrate that we can stabilize the etalon peak to a relative
precision of $<10^{-10}$; this is equivalent to 3 cm/s RV precision.
[8]
oai:arXiv.org:0708.0569 [pdf] - 556684
Investigation of the Gravitational Potential Dependence of the
Fine-Structure Constant Using Atomic Dysprosium
Submitted: 2007-08-03
Radio-frequency E1 transitions between nearly degenerate, opposite parity
levels of atomic dysprosium were monitored over an eight month period to search
for a variation in the fine-structure constant. During this time period, data
were taken at different points in the gravitational potential of the Sun. The
data are fitted to the variation in the gravitational potential yielding a
value of $(-8.7 \pm 6.6) \times 10^{-6}$ for the fit parameter $k_\alpha$. This
value gives the current best laboratory limit. In addition, our value of
$k_{\alpha}$ combined with other experimental constraints is used to extract
the first limits on k_e and k_q. These coefficients characterize the variation
of m_e/m_p and m_q/m_p in a changing gravitational potential, where m_e, m_p,
and m_q are electron, proton, and quark masses. The results are $k_e = (4.9 \pm
3.9) \times 10^{-5}$ and $k_q = (6.6 \pm 5.2) \times 10^{-5}$.