Normalized to: Lami, P.
[1]
oai:arXiv.org:1101.2023 [pdf] - 955968
Planck Early Results. II. The thermal performance of Planck
Planck Collaboration;
Ade, P. A. R.;
Aghanim, N.;
Arnaud, M.;
Ashdown, M.;
Aumont, J.;
Baccigalupi, C.;
Baker, M.;
Balbi, A.;
Banday, A. J.;
Barreiro, R. B.;
Battaner, E.;
Benabed, K.;
Benoit, A.;
Bernard, J. P.;
Bersanelli, M.;
Bhandari, P.;
Bhatia, R.;
Bock, J. J.;
Bonaldi, A.;
Bond, J. R.;
Borders, J.;
Borrill, J.;
Bouchet, F. R.;
Bowman, B.;
Bradshaw, T.;
Breelle, E.;
Bucher, M.;
Burigana, C.;
Butler, R. C.;
Cabella, P.;
Camus, P.;
Cantalupo, C. M.;
Cappellini, B.;
Cardoso, J. F.;
Catalano, A.;
Cayon, L.;
Challinor, A.;
Chamballu, A.;
Chambelland, J. P.;
Charra, J.;
Charra, M.;
Chiang, L. Y;
Chiang, C.;
Christensen, P. R.;
Clements, D. L.;
Collaudin, B.;
Colombi, S.;
Couchot, F.;
Coulais, A.;
Crill, B. P.;
Crook, M.;
Cuttaia, F.;
Damasio, C.;
Danese, L.;
Davies, R. D.;
Davis, R. J.;
de Bernardis, P.;
de Gasperis, G.;
de Rosa, A.;
Delabrouille, J.;
Delouis, J. M.;
Desert, F. -X.;
Doerl, U.;
Dolag, K.;
Donzelli, S.;
Dore, O.;
Douspis, M.;
Dupac, X.;
Efstathiou, G.;
Enslin, T. A.;
Eriksen, H. K.;
Finelli, F.;
Foley, S.;
Forni, O.;
Fosalba, P.;
Fourmond, J. J.;
Frailis, M.;
Franceschi, E.;
Galeotta, S.;
Ganga, K.;
Gavila, E.;
Giard, M.;
Giardino, G.;
Giraud-Heraud, Y.;
Gonzalez-Nuevo, J.;
Gorski, K. M.;
Gratton, S.;
Gregorio, A.;
Gruppuso, A.;
Guyot, G.;
Harrison, D.;
Helou, G.;
Henrot-Versille, S.;
Hernandez-Monteagudo, C.;
Herranz, D.;
Hildebrandt, S. R.;
Hivon, E.;
Hobson, M.;
Holmes, W. A.;
Hornstrup, A.;
Hovest, W.;
Hoyland, R. J.;
Huffenberger, K. M.;
Israelsson, U.;
Jaffe, A. H.;
Jones, W. C.;
Juvela, M.;
Keihanen, E.;
Keskitalo, R.;
Kisner, T. S.;
Kneissl, R.;
Knox, L.;
Kurki-Suonio, H.;
Lagache, G.;
Lamarre, J. M.;
Lami, P.;
Lasenby, A.;
Laureijs, R. J.;
Lawrence, C. R.;
Leach, S.;
Leonardi, R.;
Leroy, C.;
Lilje, P. B.;
Lopez-Caniego, M.;
Lubin, P. M.;
Macias-Perez, J. F.;
Maciaszek, T.;
MacTavish, C. J.;
Maffei, B.;
Maino, D.;
Mandolesi, N.;
Mann, R.;
Maris, M.;
Martinez-Gonzalez, E.;
Masi, S.;
Matarrese, S.;
Matthai, F.;
Mazzotta, P.;
McGehee, P.;
Meinhold, P. R.;
Melchiorri, A.;
Melot, F.;
Mendes, L.;
Mennella, A.;
Miville-Deschenes, M. -A.;
Moneti, A.;
Montier, L.;
Mora, J.;
Morgante, G.;
Morisset, N.;
Mortlock, D.;
Munshi, D.;
Murphy, A.;
Naselsky, P.;
Nash, A.;
Natoli, P.;
Netterfield, C. B.;
Novikov, D.;
Novikov, I.;
O'Dwyer, I. J.;
Osborne, S.;
Pajot, F.;
Pasian, F.;
Patanchon, G.;
Pearson, D.;
Perdereau, O.;
Perotto, L.;
Perrotta, F.;
Piacentini, F.;
Piat, M.;
Plaszczynski, S.;
Platania, P.;
Pointecouteau, E.;
Polenta, G.;
Ponthieu, N.;
Poutanen, T.;
Prezeau, G.;
Prina, M.;
Prunet, S.;
Puget, J. L.;
Rachen, J. P.;
Rebolo, R.;
Reinecke, M.;
Renault, C.;
Ricciardi, S.;
Riller, T.;
Ristorcelli, I.;
Rocha, G.;
Rosset, C.;
Rubiino-Martin, J. A.;
Rusholme, B.;
Sandri, M.;
Santos, D.;
Schaefer, B. M.;
Scott, D.;
Seiffert, M. D.;
Shellard, P.;
Smoot, G. F.;
Starck, J. -L.;
Stassi, P.;
Stivoli, F.;
Stolyarov, V.;
Stompor, R.;
Sudiwala, R.;
Sygnet, J. -F.;
Tauber, J. A.;
Terenzi, L.;
Toffolatti, L.;
Tomasi, M.;
Torre, J. -P.;
Tristram, M.;
Tuovinen, J.;
Valenziano, L.;
Vibert, L.;
Vielva, P.;
Villa, F.;
Vittorio, N.;
Wade, L. A.;
Wandelt, B. D.;
Watson, C.;
White, S. D. M.;
Wilkinson, A.;
Wilson, P.;
Yvon, D.;
Zacchei, A.;
Zhang, B.;
Zonca, A.
Submitted: 2011-01-11, last modified: 2012-01-02
The performance of the Planck instruments in space is enabled by their low
operating temperatures, 20K for LFI and 0.1K for HFI, achieved through a
combination of passive radiative cooling and three active mechanical coolers.
The scientific requirement for very broad frequency coverage led to two
detector technologies with widely different temperature and cooling needs.
Active coolers could satisfy these needs; a helium cryostat, as used by
previous cryogenic space missions (IRAS, COBE, ISO, Spitzer, AKARI), could not.
Radiative cooling is provided by three V-groove radiators and a large telescope
baffle. The active coolers are a hydrogen sorption cooler (<20K), a 4He
Joule-Thomson cooler (4.7K), and a 3He-4He dilution cooler (1.4K and 0.1K). The
flight system was at ambient temperature at launch and cooled in space to
operating conditions. The HFI bolometer plate reached 93mK on 3 July 2009, 50
days after launch. The solar panel always faces the Sun, shadowing the rest of
Planck, andoperates at a mean temperature of 384K. At the other end of the
spacecraft, the telescope baffle operates at 42.3K and the telescope primary
mirror operates at 35.9K. The temperatures of key parts of the instruments are
stabilized by both active and passive methods. Temperature fluctuations are
driven by changes in the distance from the Sun, sorption cooler cycling and
fluctuations in gas-liquid flow, and fluctuations in cosmic ray flux on the
dilution and bolometer plates. These fluctuations do not compromise the science
data.
[2]
oai:arXiv.org:1101.2039 [pdf] - 1051324
Planck early results: first assessment of the High Frequency Instrument
in-flight performance
Planck HFI Core Team;
Ade, P. A. R.;
Aghanim, N.;
Ansari, R.;
Arnaud, M.;
Ashdown, M.;
Aumont, J.;
Banday, A. J.;
Bartelmann, M.;
Bartlett, J. G.;
Battaner, E.;
Benabed, K.;
Benot, A.;
Bernard, J. -P.;
Bersanelli, M.;
Bhatia, R.;
Bock, J. J.;
Bond, J. R.;
Borrill, J.;
Bouchet, F. R.;
Boulanger, F.;
Bradshaw, T.;
Brelle, E.;
Bucher, M.;
Camus, P.;
Cardoso, J. -F.;
Catalano, A.;
Challinor, A.;
Chamballu, A.;
Charra, J.;
Charra, M.;
Chary, R. -R.;
Chiang, C.;
Church, S.;
Clements, D. L.;
Colombi, S.;
Couchot, F.;
Coulais, A.;
Cressiot, C.;
Crill, B. P.;
Crook, M.;
de Bernardis, P.;
Delabrouille, J.;
Delouis, J. -M.;
Désert, F. -X.;
Dolag, K.;
Dole, H.;
Doré, O.;
Douspis, M.;
Efstathiou, G.;
Eng, P.;
Filliard, C.;
Forni, O.;
Fosalba, P.;
Fourmond, J. -J.;
Ganga, K.;
Giard, M.;
Girard, D.;
Giraud-Héraud, Y.;
Gispert, R.;
Gorski, K. M.;
Gratton, S.;
Griffin, M.;
Guyot, G.;
Haissinski, J.;
Harrison, D.;
Helou, G.;
Henrot-Versillé, S.;
Hernandez-Monteagudo, C.;
Hildebrandt, S. R.;
Hills, R.;
Hivon, E.;
Hobson, M.;
Holmes, W. A.;
Huenberger, K. M.;
Jae, A. H.;
Jones, W. C.;
Kaplan, J.;
Kneissl, R.;
Knox, L.;
Lagache, G.;
Lamarre, J. -M.;
Lami, P.;
Lange, A. E.;
Lasenby, A.;
Lavabre, A.;
Lawrence, C. R.;
Leriche, B.;
Leroy, C.;
Longval, Y.;
Macas-Perez, J. F.;
Maciaszek, T.;
MacTavish, C. J.;
Maei, B.;
Mandolesi, N.;
Mann, R.;
Mansoux, B.;
Masi, S.;
Matsumura, T.;
McGehee, P.;
Melin, J. -B.;
Mercier, C.;
Miville-Deschnes, M. -A.;
Moneti, A.;
Montier, L.;
Mortlock, D.;
Murphy, A.;
Nati, F.;
Nettereld, C. B.;
Norgaard-Nielsen, H. U.;
North, C.;
Noviello, F.;
Novikov, D.;
Osborne, S.;
Paine, C.;
Pajot, F.;
Patanchon, G.;
Peacocke, T.;
Pearson, T. J.;
Perdereau, O.;
Perotto, L.;
Piacentini, F.;
Piat, M.;
Plaszczynski, S.;
Pointecouteau, E.;
Pons, R.;
Ponthieu, N.;
Prezeau, G.;
Prunet, S.;
Puget, J. -L.;
Reach, W. T.;
Renault, C.;
Ristorcelli, I.;
Rocha, G.;
Rosset, C.;
Roudier, G.;
Rowan-Robinson, M.;
Rusholme, B.;
Santos, D.;
Savini, G.;
Schaefer, B. M.;
Shellard, P.;
Spencer, L.;
Starck, J. -L.;
Stassi, P.;
Stolyarov, V.;
Stompor, R.;
Sudiwala, R.;
Sunyaev, R.;
Sygnet, J. -F.;
Tauber, J. A.;
Thum, C.;
Torre, J. -P.;
Touze, F.;
Tristram, M.;
Van Leeuwen, F.;
Vibert, L.;
Vibert, D.;
Wade, L. A.;
Wandelt, B. D.;
White, S. D. M.;
Wiesemeyer, H.;
Woodcraft, A.;
Yurchenko, V.;
Yvon, D.;
Zacchei, A.
Submitted: 2011-01-11
The Planck High Frequency Instrument (HFI) is designed to measure the
temperature and polarization anisotropies of the Cosmic Microwave Background
and galactic foregrounds in six wide bands centered at 100, 143, 217, 353, 545
and 857 GHz at an angular resolution of 10' (100 GHz), 7' (143 GHz), and 5'
(217 GHz and higher). HFI has been operating flawlessly since launch on 14 May
2009. The bolometers cooled to 100 mK as planned. The settings of the readout
electronics, such as the bolometer bias current, that optimize HFI's noise
performance on orbit are nearly the same as the ones chosen during ground
testing. Observations of Mars, Jupiter, and Saturn verified both the optical
system and the time response of the detection chains. The optical beams are
close to predictions from physical optics modeling. The time response of the
detection chains is close to pre-launch measurements. The detectors suffer from
an unexpected high flux of cosmic rays related to low solar activity. Due to
the redundancy of Planck's observations strategy, the removal of a few percent
of data contaminated by glitches does not affect significantly the sensitivity.
The cosmic rays heat up significantly the bolometer plate and the modulation on
periods of days to months of the heat load creates a common drift of all
bolometer signals which do not affect the scientific capabilities. Only the
high energy cosmic rays showers induce inhomogeneous heating which is a
probable source of low frequency noise.