sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

LaMarr, B.

Normalized to: LaMarr, B.

14 article(s) in total. 92 co-authors, from 1 to 9 common article(s). Median position in authors list is 6,5.

[1]  oai:arXiv.org:2006.11358  [pdf] - 2119143
A possible polar origin for the FRB associated with a Galactic magnetar
Comments: Submitted to Nature
Submitted: 2020-06-19
Fast Radio Bursts (FRBs) are millisecond-long radio pulses of extragalactic origin with peak luminosities far exceeding any Milky Way sources. The prevalent invocation for the FRB origin involves magnetars: young, magnetically powered neutron stars with the strongest magnetic fields in the Universe. A magnetar-defining signature is the emission of bright, hard X-ray bursts of sub-second duration. These occur in isolation or during a burst storm, when several hundred are observed within minutes to hours. On April 27th 2020, the Galactic magnetar SGR J1935+2154 entered an active period, emitting hundreds of X-ray bursts in a few hours. Remarkably, only one of these temporally coincided with an FRB-like radio burst. Here we report on the spectral and temporal analyses of 24 X-ray bursts emitted 13 hours prior to the FRB and seen simultaneously with NASA NICER and Fermi/GBM missions in their combined energy range. We demonstrate that the FRB-associated X-ray burst is very similar temporally, albeit strikingly different spectrally, from the 24 NICER/GBM bursts. If the FRB-associated burst were drawn from this magnetar burst population, its occurrence rate would be at most around 1 in 7000. This rarity combined with the unusual X-ray burst spectrum is perhaps indicative of an uncommon locale for the origin of the FRB-associated burst. We suggest that this unique event originated in quasi-polar open or closed magnetic field lines extending to high altitudes where radio emission can be generated, possibly from a collimated plasma flow.
[2]  oai:arXiv.org:1808.06442  [pdf] - 1735589
NICER Detection of Strong Photospheric Expansion during a Thermonuclear X-Ray Burst from 4U 1820-30
Comments: 6 pages, 4 figures, 1 table, published by ApJ Letters
Submitted: 2018-08-20
The Neutron Star Interior Composition Explorer (NICER) on the International Space Station (ISS) observed strong photospheric expansion of the neutron star in 4U 1820-30 during a Type I X-ray burst. A thermonuclear helium flash in the star's envelope powered a burst that reached the Eddington limit. Radiation pressure pushed the photosphere out to ~200 km, while the blackbody temperature dropped to 0.45 keV. Previous observations of similar bursts were performed with instruments that are sensitive only above 3 keV, and the burst signal was weak at low temperatures. NICER's 0.2-12 keV passband enables the first complete detailed observation of strong expansion bursts. The strong expansion lasted only 0.6 s, and was followed by moderate expansion with a 20 km apparent radius, before the photosphere finally settled back down at 3 s after the burst onset. In addition to thermal emission from the neutron star, the NICER spectra reveal a second component that is well fit by optically thick Comptonization. During the strong expansion, this component is six times brighter than prior to the burst, and it accounts for 71% of the flux. In the moderate expansion phase, the Comptonization flux drops, while the thermal component brightens, and the total flux remains constant at the Eddington limit. We speculate that the thermal emission is reprocessed in the accretion environment to form the Comptonization component, and that changes in the covering fraction of the star explain the evolution of the relative contributions to the total flux.
[3]  oai:arXiv.org:1806.10094  [pdf] - 1732756
NICER and Fermi GBM Observations of the First Galactic Ultraluminous X-ray Pulsar Swift J0243.6+6124
Comments: 35 pages, 7 figures (main text), 5 figures (appendix); Accepted for publication in ApJ on June 19, 2018
Submitted: 2018-06-26
Swift J0243.6+6124 is a newly discovered Galactic Be/X-ray binary, revealed in late September 2017 in a giant outburst with a peak luminosity of 2E+39 (d/7 kpc)^2 erg/s (0.1-10 keV), with no formerly reported activity. At this luminosity, Swift J0243.6+6124 is the first known galactic ultraluminous X-ray pulsar. We describe Neutron star Interior Composition Explorer (NICER)} and Fermi Gamma-ray Burst Monitor (GBM) timing and spectral analyses for this source. A new orbital ephemeris is obtained for the binary system using spin-frequencies measured with GBM and 15-50 keV fluxes measured with the Neil Gehrels Swift Observatory Burst Alert Telescope to model the system's intrinsic spin-up. Power spectra measured with NICER show considerable evolution with luminosity, including a quasi-periodic oscillation (QPO) near 50 mHz that is omnipresent at low luminosity and has an evolving central frequency. Pulse profiles measured over the combined 0.2-100 keV range show complex evolution that is both luminosity and energy dependent. Near the critical luminosity of L~1E+38 erg/s, the pulse profiles transition from single-peaked to double peaked, the pulsed fraction reaches a minimum in all energy bands, and the hardness ratios in both NICER and GBM show a turn-over to softening as the intensity increases. This behavior repeats as the outburst rises and fades, indicating two distinct accretion regimes. These two regimes are suggestive of the accretion structure on the neutron star surface transitioning from a Coulomb collisional stopping mechanism at lower luminosities to a radiation-dominated stopping mechanism at higher luminosities. This is the highest observed (to date) value of the critical luminosity, suggesting a magnetic field of B ~1E+13 G.
[4]  oai:arXiv.org:1806.02342  [pdf] - 1709519
A Persistent Disk Wind in GRS 1915+105 with NICER
Comments: Accepted for publication in ApJL. Comments welcome
Submitted: 2018-06-06
The bright, erratic black hole X-ray binary GRS 1915+105 has long been a target for studies of disk instabilities, radio/infrared jets, and accretion disk winds, with implications that often apply to sources that do not exhibit its exotic X-ray variability. With the launch of NICER, we have a new opportunity to study the disk wind in GRS 1915+105 and its variability on short and long timescales. Here we present our analysis of 39 NICER observations of GRS 1915+105 collected during five months of the mission data validation and verification phase, focusing on Fe XXV and Fe XXVI absorption. We report the detection of strong Fe XXVI in 32 (>80%) of these observations, with another four marginal detections; Fe XXV is less common, but both likely arise in the well-known disk wind. We explore how the properties of this wind depends on broad characteristics of the X-ray lightcurve: mean count rate, hardness ratio, and fractional RMS variability. The trends with count rate and RMS are consistent with an average wind column density that is fairly steady between observations but varies rapidly with the source on timescales of seconds. The line dependence on spectral hardness echoes known behavior of disk winds in outbursts of Galactic black holes; these results clearly indicate that NICER is a powerful tool for studying black hole winds.
[5]  oai:arXiv.org:1007.4185  [pdf] - 1033875
Using ACIS on the Chandra X-ray Observatory as a particle radiation monitor
Comments: 10 pages, 5 figures. To appear in Proc. SPIE vol. 7732
Submitted: 2010-07-23
The Advanced CCD Imaging Spectrometer (ACIS) is one of two focal-plane instruments on the Chandra X-ray Observatory. During initial radiation-belt passes, the exposed ACIS suffered significant radiation damage from trapped soft protons scattering off the x-ray telescope's mirrors. The primary effect of this damage was to increase the charge-transfer inefficiency (CTI) of the ACIS 8 front-illuminated CCDs. Subsequently, the Chandra team implemented procedures to remove the ACIS from the telescope's focus during high-radiation events: planned protection during radiation-belt transits; autonomous protection triggered by an on-board radiation monitor; and manual intervention based upon assessment of space-weather conditions. However, as Chandra's multilayer insulation ages, elevated temperatures have reduced the effectiveness of the on-board radiation monitor for autonomous protection. Here we investigate using the ACIS CCDs themselves as a radiation monitor. We explore the 10-year database to evaluate the CCDs' response to particle radiation and to compare this response with other radiation data and environment models.
[6]  oai:arXiv.org:0810.0873  [pdf] - 1000970
New CTI Correction Method for the Spaced-Row Charge Injection of the Suzaku X-Ray Imaging Spectrometer
Comments: 7 pages, 14 figures
Submitted: 2008-10-06
The charge transfer inefficiency (CTI) of the X-ray CCDs on board the Suzaku satellite (X-ray Imaging Spectrometers; XIS) has increased since the launch due to radiation damage, and the energy resolution has been degraded. To improve the CTI, we have applied a spaced-row charge injection (SCI) technique to the XIS in orbit; by injecting charges into CCD rows periodically, the CTI is actively decreased. The CTI in the SCI mode depends on the distance between a signal charge and a preceding injected row, and the pulse height shows periodic positional variations. Using in-flight data of onboard calibration sources and of the strong iron line from the Perseus cluster of galaxies, we studied the variation in detail. We developed a new method to correct the variation. By applying the new method, the energy resolution (FWHM) at 5.9 keV at March 2008 is ~155 eV for the front-illuminated CCDs and ~175 eV for the back-illuminated CCD.
[7]  oai:arXiv.org:0809.3665  [pdf] - 16568
Energy-Scale Calibration of the Suzaku X-Ray Imaging Spectrometer Using the Checker Flag Charge Injection Technique in Orbit
Comments: 8 pages, 10 figures, accepted for publication in PASJ (Suzaku 3rd special issue)
Submitted: 2008-09-22
The X-ray Imaging Spectrometer (XIS) on board the Suzaku satellite is an X-ray CCD camera system that has superior performance such as a low background, high quantum efficiency, and good energy resolution in the 0.2-12 keV band. Because of the radiation damage in orbit, however, the charge transfer inefficiency (CTI) has increased, and hence the energy scale and resolution of the XIS has been degraded since the launch of July 2005. The CCD has a charge injection structure, and the CTI of each column and the pulse-height dependence of the CTI are precisely measured by a checker flag charge injection (CFCI) technique. Our precise CTI correction improved the energy resolution from 230 eV to 190 eV at 5.9 keV in December 2006. This paper reports the CTI measurements with the CFCI experiments in orbit. Using the CFCI results, we have implemented the time-dependent energy scale and resolution to the Suzaku calibration database.
[8]  oai:arXiv.org:0807.1721  [pdf] - 14403
Physics of reverse annealing in high-resistivity Chandra ACIS CCDs
Comments: 9 pages, to appear in Proc. SPIE 7021, "High Energy, Optical and Infrared Detectors for Astronomy"
Submitted: 2008-07-10
After launch, the Advanced CCD Imaging Spectrometer (ACIS), a focal plane instrument on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. An effect of the damage was to increase the charge transfer inefficiency (CTI) of the front illuminated CCDs. As part of the initial damage assessment, the focal plane was warmed from the operating temperature of -100C to +30C which unexpectedly further increased the CTI. We report results of ACIS CCD irradiation experiments in the lab aimed at better understanding this reverse annealing process. Six CCDs were irradiated cold by protons ranging in energy from 100 keV to 400 keV, and then subjected to simulated bakeouts in one of three annealing cycles. We present results of these lab experiments, compare them to our previous experiences on the ground and in flight, and derive limits on the annealing time constants.
[9]  oai:arXiv.org:0705.1771  [pdf] - 1529986
Performance of the Charge Injection Capability of Suzaku XIS
Comments: Paper contains 18 figures and 15 tables. Accepted for publication in PASJ
Submitted: 2007-05-12
A charge injection technique is applied to the X-ray CCD camera, XIS (X-ray Imaging Spectrometer) onboard Suzaku. The charge transfer inefficiency (CTI) in each CCD column (vertical transfer channel) is measured by the injection of charge packets into a transfer channel and subsequent readout. This paper reports the performances of the charge injection capability based on the ground experiments using a radiation damaged device, and in-orbit measurements of the XIS. The ground experiments show that charges are stably injected with the dispersion of 91eV in FWHM in a specific column for the charges equivalent to the X-ray energy of 5.1keV. This dispersion width is significantly smaller than that of the X-ray events of 113eV (FWHM) at approximately the same energy. The amount of charge loss during transfer in a specific column, which is measured with the charge injection capability, is consistent with that measured with the calibration source. These results indicate that the charge injection technique can accurately measure column-dependent charge losses rather than the calibration sources. The column-to-column CTI correction to the calibration source spectra significantly reduces the line widths compared to those with a column-averaged CTI correction (from 193eV to 173eV in FWHM on an average at the time of one year after the launch). In addition, this method significantly reduces the low energy tail in the line profile of the calibration source spectrum.
[10]  oai:arXiv.org:astro-ph/0606178  [pdf] - 82618
Temperature dependence of charge transfer inefficiency in Chandra X-ray CCDs
Comments: 9 pages, 8 figures, to appear in Proc. SPIE vol 6276 "High Energy, Optical, and Infrared Detectors for Astronomy II"
Submitted: 2006-06-07
Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. The primary effect of the damage was to increase the charge transfer inefficiency (CTI) of the eight front illuminated CCDs by more than two orders of magnitude. The ACIS instrument team is continuing to study the properties of the damage with an emphasis on developing techniques to mitigate CTI and spectral resolution degradation. We present the initial temperature dependence of ACIS CTI from -120 to -60 degrees Celsius and the current temperature dependence after more than six years of continuing slow radiation damage. We use the change of shape of the temperature dependence to speculate on the nature of the damaging particles.
[11]  oai:arXiv.org:astro-ph/0509035  [pdf] - 75617
Long-term trends in radiation damage of Chandra X-ray CCDs
Comments: 10 pages, 14 figures to appear in Proc. SPIE vol. 5898 "UV, X-ray, and Gamma-Ray Space Instrumentation for Astronomy XIV"
Submitted: 2005-09-01
Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. Current operations require ACIS to be protected during radiation belt passages to prevent this type of damage, but there remains a much slower and more gradual increase. We present the history of ACIS charge transfer inefficiency (CTI), and other measures of radiation damage, from January 2000 through June 2005. The rate of CTI increase is low, of order 1e-6 per year, with no indication of step-function increases due to specific solar events. Based on the time history and CCD location of the CTI increase, we speculate on the nature of the damaging particles.
[12]  oai:arXiv.org:astro-ph/0407199  [pdf] - 66041
A charge transfer inefficiency correction model for the Chandra Advanced CCD Imaging Spectrometer
Comments: 12 pages, 12 figures, will appear in Proc. SPIE 5501
Submitted: 2004-07-09
Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. The primary effect of the damage was to increase the charge transfer inefficiency (CTI) of the eight front illuminated CCDs by more than two orders of magnitude. The ACIS instrument team is continuing to study the properties of the damage with an emphasis on developing techniques to mitigate CTI and spectral resolution degradation. We will discuss the characteristics of the damage, the detector and the particle background and how they conspire to degrade the instrument performance. We have developed a model for ACIS CTI which can be used to correct each event and regain some of the lost performance. The correction uses a map of the electron trap distribution, a parameterization of the energy dependent charge loss and the fraction of the lost charge re-emitted into the trailing pixel to correct the pixels in the event island. This model has been implemented in the standard Chandra data processing pipeline. Some of the correction algorithm was inspired by the earlier work on ACIS CTI correction by Townsley et al. (2000; 2002). The details of the CTI model and how each parameter improves performance will be discussed, as well as the limitations and the possibilities for future improvement.
[13]  oai:arXiv.org:astro-ph/0209126  [pdf] - 51532
Sacrificial charge and the spectral resolution performance of the Chandra Advanced CCD Imaging Spectrometer
Comments: 9 pages, 7 figures to be published in Proc. SPIE 4851
Submitted: 2002-09-06
Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. The ACIS team is continuing to study the properties of the damage with an emphasis on developing techniques to mitigate charge transfer inefficiency (CTI) and spectral resolution degradation. A post-facto CTI corrector has been developed which can effectively recover much of the lost resolution. Any further improvements in performance will require knowledge of the location and amount of sacrificial charge - charge deposited along the readout path of an event which fills electron traps and changes CTI. We report on efforts by the ACIS Instrument team to characterize which charge traps cause performance degradation and the properties of the sacrificial charge seen on-orbit. We also report on attempts to correct X-ray pulseheights for the presence of sacrificial charge.
[14]  oai:arXiv.org:astro-ph/0112041  [pdf] - 46414
Analysis of On-Orbit ACIS Squeegee Mode Data on Chip I0
Comments: 11 pages, 5 figures. To appear in ``The High Energy Universe at Sharp Focus'' (St. Paul, Minnesota 2001), eds Schlegel and Vrtilek (ASP Conference Series). Paper also at http://hea-www.harvard.edu/~svirani/paper.html
Submitted: 2001-12-03
The MIT and CXC ACIS teams have explored a number of measures to ameliorate the effects of radiation damage suffered by the ACIS FI CCDs. One of these measures is a novel CCD read-out method called ``squeegee mode''. A variety of different implementations of the squeegee mode have now been tested on the I0 CCD. Our results for the fitted FWHM at Al-K$\alpha$ and Mn-K$\alpha$ clearly demonstrate that all the squeegee modes provide improved performance in terms of reducing CTI and improving spectral resolution. Our analysis of the detection efficiency shows that the so-called squeegee modes ``Vanilla'' and ``Maximum Observing Efficiency'' provide the same detection efficiency as the standard clocking, once the decay in the intensity of the radioactive source has been taken into account. The squeegee modes which utilize the slow parallel transfer (``Maximum Spectral Resolution'', ``Maximum Angular Resolution'', and ``Sub-Array'') show a significantly lower detection efficiency than the standard clocking. The slow parallel transfer squeegee modes exhibit severe grade migration from flight grade 0 to flight grade 64 and a smaller migration into ASCA g7. The latter effect can explain some of the drop in detection efficiency. (ABRIDGED ABSTRACT)