Normalized to: LaMarr, B.
[1]
oai:arXiv.org:2006.11358 [pdf] - 2119143
A possible polar origin for the FRB associated with a Galactic magnetar
Younes, G.;
Baring, M. G.;
Kouveliotou, C.;
Arzoumanian, Z.;
Enoto, T.;
Doty, J.;
Gendreau, K. C.;
Göğüş, E.;
Guillot, S.;
Güver, T.;
Harding, A. K.;
Ho, W. C. G.;
van der Horst, A. J.;
Jaisawal, G. K.;
Kaneko, Y.;
LaMarr, B. J.;
Lin, L.;
Majid, W.;
Okajima, T.;
Pope, J.;
Ray, P. S.;
Roberts, O. J.;
Saylor, M.;
Steiner, J. F.;
Wadiasingh, Z.
Submitted: 2020-06-19
Fast Radio Bursts (FRBs) are millisecond-long radio pulses of extragalactic
origin with peak luminosities far exceeding any Milky Way sources. The
prevalent invocation for the FRB origin involves magnetars: young, magnetically
powered neutron stars with the strongest magnetic fields in the Universe. A
magnetar-defining signature is the emission of bright, hard X-ray bursts of
sub-second duration. These occur in isolation or during a burst storm, when
several hundred are observed within minutes to hours. On April 27th 2020, the
Galactic magnetar SGR J1935+2154 entered an active period, emitting hundreds of
X-ray bursts in a few hours. Remarkably, only one of these temporally coincided
with an FRB-like radio burst. Here we report on the spectral and temporal
analyses of 24 X-ray bursts emitted 13 hours prior to the FRB and seen
simultaneously with NASA NICER and Fermi/GBM missions in their combined energy
range. We demonstrate that the FRB-associated X-ray burst is very similar
temporally, albeit strikingly different spectrally, from the 24 NICER/GBM
bursts. If the FRB-associated burst were drawn from this magnetar burst
population, its occurrence rate would be at most around 1 in 7000. This rarity
combined with the unusual X-ray burst spectrum is perhaps indicative of an
uncommon locale for the origin of the FRB-associated burst. We suggest that
this unique event originated in quasi-polar open or closed magnetic field lines
extending to high altitudes where radio emission can be generated, possibly
from a collimated plasma flow.
[2]
oai:arXiv.org:1808.06442 [pdf] - 1735589
NICER Detection of Strong Photospheric Expansion during a Thermonuclear
X-Ray Burst from 4U 1820-30
Keek, L.;
Arzoumanian, Z.;
Chakrabarty, D.;
Chenevez, J.;
Gendreau, K. C.;
Guillot, S.;
Güver, T.;
Homan, J.;
Jaisawal, G. K.;
LaMarr, B.;
Lamb, F. K.;
Mahmoodifar, S.;
Markwardt, C. B.;
Okajima, T.;
Strohmayer, T. E.;
Zand, J. J. M. in 't
Submitted: 2018-08-20
The Neutron Star Interior Composition Explorer (NICER) on the International
Space Station (ISS) observed strong photospheric expansion of the neutron star
in 4U 1820-30 during a Type I X-ray burst. A thermonuclear helium flash in the
star's envelope powered a burst that reached the Eddington limit. Radiation
pressure pushed the photosphere out to ~200 km, while the blackbody temperature
dropped to 0.45 keV. Previous observations of similar bursts were performed
with instruments that are sensitive only above 3 keV, and the burst signal was
weak at low temperatures. NICER's 0.2-12 keV passband enables the first
complete detailed observation of strong expansion bursts. The strong expansion
lasted only 0.6 s, and was followed by moderate expansion with a 20 km apparent
radius, before the photosphere finally settled back down at 3 s after the burst
onset. In addition to thermal emission from the neutron star, the NICER spectra
reveal a second component that is well fit by optically thick Comptonization.
During the strong expansion, this component is six times brighter than prior to
the burst, and it accounts for 71% of the flux. In the moderate expansion
phase, the Comptonization flux drops, while the thermal component brightens,
and the total flux remains constant at the Eddington limit. We speculate that
the thermal emission is reprocessed in the accretion environment to form the
Comptonization component, and that changes in the covering fraction of the star
explain the evolution of the relative contributions to the total flux.
[3]
oai:arXiv.org:1806.10094 [pdf] - 1732756
NICER and Fermi GBM Observations of the First Galactic Ultraluminous
X-ray Pulsar Swift J0243.6+6124
Wilson-Hodge, C. A.;
Malacaria, C.;
Jenke, P. A.;
Jaisawal, G. K.;
Kerr, M.;
Wolff, M. T.;
Arzoumanian, Z.;
Chakrabarty, D.;
Doty, J. P.;
Gendreau, K. C.;
Guillot, S.;
Ho, W. C. G.;
LaMarr, B.;
Markwardt, C. B.;
Ozel, F.;
Prigozhin, G. Y.;
Ray, P. S.;
Ramos-Lerate, M.;
Remillard, R. A.;
Strohmayer, T. E.;
Vezie, M. L.;
Wood, K. S.
Submitted: 2018-06-26
Swift J0243.6+6124 is a newly discovered Galactic Be/X-ray binary, revealed
in late September 2017 in a giant outburst with a peak luminosity of 2E+39 (d/7
kpc)^2 erg/s (0.1-10 keV), with no formerly reported activity. At this
luminosity, Swift J0243.6+6124 is the first known galactic ultraluminous X-ray
pulsar. We describe Neutron star Interior Composition Explorer (NICER)} and
Fermi Gamma-ray Burst Monitor (GBM) timing and spectral analyses for this
source. A new orbital ephemeris is obtained for the binary system using
spin-frequencies measured with GBM and 15-50 keV fluxes measured with the Neil
Gehrels Swift Observatory Burst Alert Telescope to model the system's intrinsic
spin-up. Power spectra measured with NICER show considerable evolution with
luminosity, including a quasi-periodic oscillation (QPO) near 50 mHz that is
omnipresent at low luminosity and has an evolving central frequency. Pulse
profiles measured over the combined 0.2-100 keV range show complex evolution
that is both luminosity and energy dependent. Near the critical luminosity of
L~1E+38 erg/s, the pulse profiles transition from single-peaked to double
peaked, the pulsed fraction reaches a minimum in all energy bands, and the
hardness ratios in both NICER and GBM show a turn-over to softening as the
intensity increases. This behavior repeats as the outburst rises and fades,
indicating two distinct accretion regimes. These two regimes are suggestive of
the accretion structure on the neutron star surface transitioning from a
Coulomb collisional stopping mechanism at lower luminosities to a
radiation-dominated stopping mechanism at higher luminosities. This is the
highest observed (to date) value of the critical luminosity, suggesting a
magnetic field of B ~1E+13 G.
[4]
oai:arXiv.org:1806.02342 [pdf] - 1709519
A Persistent Disk Wind in GRS 1915+105 with NICER
Neilsen, Joey;
Cackett, E.;
Remillard, R. A.;
Homan, J.;
Steiner, J. F.;
Gendreau, K.;
Arzoumanian, Z.;
Prigozhin, G.;
LaMarr, B.;
Doty, J.;
Eikenberry, S.;
Tombesi, F.;
Ludlam, R.;
Kara, E.;
Altamirano, D.;
Fabian, A. C.
Submitted: 2018-06-06
The bright, erratic black hole X-ray binary GRS 1915+105 has long been a
target for studies of disk instabilities, radio/infrared jets, and accretion
disk winds, with implications that often apply to sources that do not exhibit
its exotic X-ray variability. With the launch of NICER, we have a new
opportunity to study the disk wind in GRS 1915+105 and its variability on short
and long timescales. Here we present our analysis of 39 NICER observations of
GRS 1915+105 collected during five months of the mission data validation and
verification phase, focusing on Fe XXV and Fe XXVI absorption. We report the
detection of strong Fe XXVI in 32 (>80%) of these observations, with another
four marginal detections; Fe XXV is less common, but both likely arise in the
well-known disk wind. We explore how the properties of this wind depends on
broad characteristics of the X-ray lightcurve: mean count rate, hardness ratio,
and fractional RMS variability. The trends with count rate and RMS are
consistent with an average wind column density that is fairly steady between
observations but varies rapidly with the source on timescales of seconds. The
line dependence on spectral hardness echoes known behavior of disk winds in
outbursts of Galactic black holes; these results clearly indicate that NICER is
a powerful tool for studying black hole winds.
[5]
oai:arXiv.org:1007.4185 [pdf] - 1033875
Using ACIS on the Chandra X-ray Observatory as a particle radiation
monitor
Submitted: 2010-07-23
The Advanced CCD Imaging Spectrometer (ACIS) is one of two focal-plane
instruments on the Chandra X-ray Observatory. During initial radiation-belt
passes, the exposed ACIS suffered significant radiation damage from trapped
soft protons scattering off the x-ray telescope's mirrors. The primary effect
of this damage was to increase the charge-transfer inefficiency (CTI) of the
ACIS 8 front-illuminated CCDs. Subsequently, the Chandra team implemented
procedures to remove the ACIS from the telescope's focus during high-radiation
events: planned protection during radiation-belt transits; autonomous
protection triggered by an on-board radiation monitor; and manual intervention
based upon assessment of space-weather conditions. However, as Chandra's
multilayer insulation ages, elevated temperatures have reduced the
effectiveness of the on-board radiation monitor for autonomous protection. Here
we investigate using the ACIS CCDs themselves as a radiation monitor. We
explore the 10-year database to evaluate the CCDs' response to particle
radiation and to compare this response with other radiation data and
environment models.
[6]
oai:arXiv.org:0810.0873 [pdf] - 1000970
New CTI Correction Method for the Spaced-Row Charge Injection of the
Suzaku X-Ray Imaging Spectrometer
Uchiyama, Hideki;
Ozawa, Midori;
Matsumoto, Hironori;
Tsuru, Takeshi Go;
Koyama, Katsuji;
Kimura, Masashi;
Uchida, Hiroyuki;
Nakajima, Hiroshi;
Hayashida, Kiyoshi;
Tsunemi, Hiroshi;
Mori, Hideyuki;
Bamba, Aya;
Ozaki, Masanobu;
Dotani, Tadayasu;
Takei, Dai;
Murakami, Hiroshi;
Mori, Koji;
Ishisaki, Yoshitaka;
Kohmura, Takayoshi;
Prigozhin, Gregory;
Kissel, Steve;
Miller, Eric;
LaMarr, Beverly;
Bautz, Marshall
Submitted: 2008-10-06
The charge transfer inefficiency (CTI) of the X-ray CCDs on board the Suzaku
satellite (X-ray Imaging Spectrometers; XIS) has increased since the launch due
to radiation damage, and the energy resolution has been degraded. To improve
the CTI, we have applied a spaced-row charge injection (SCI) technique to the
XIS in orbit; by injecting charges into CCD rows periodically, the CTI is
actively decreased. The CTI in the SCI mode depends on the distance between a
signal charge and a preceding injected row, and the pulse height shows periodic
positional variations. Using in-flight data of onboard calibration sources and
of the strong iron line from the Perseus cluster of galaxies, we studied the
variation in detail. We developed a new method to correct the variation. By
applying the new method, the energy resolution (FWHM) at 5.9 keV at March 2008
is ~155 eV for the front-illuminated CCDs and ~175 eV for the back-illuminated
CCD.
[7]
oai:arXiv.org:0809.3665 [pdf] - 16568
Energy-Scale Calibration of the Suzaku X-Ray Imaging Spectrometer Using
the Checker Flag Charge Injection Technique in Orbit
Ozawa, Midori;
Uchiyama, Hideki;
Matsumoto, Hironori;
Nakajima, Hiroshi;
Koyama, Katsuji;
Tsuru, Takeshi Go;
Uchino, Masahiro;
Uchida, Hiroyuki;
Hayashida, Kiyoshi;
Tsunemi, Hiroshi;
Mori, Hideyuki;
Bamba, Aya;
Ozaki, Masanobu;
Dotani, Tadayasu;
Kohmura, Takayoshi;
Ishisaki, Yoshitaka;
Murakami, Hiroshi;
Kato, Takeshi;
Kitazono, Takeshi;
Kimura, Yuki;
Ogawa, Kazuki;
Kawai, Shunsuke;
Mori, Koji;
Prigozhin, Gregory;
Kissel, Steve;
Miller, Eric;
LaMarr, Beverly;
Bautz, Marshall
Submitted: 2008-09-22
The X-ray Imaging Spectrometer (XIS) on board the Suzaku satellite is an
X-ray CCD camera system that has superior performance such as a low background,
high quantum efficiency, and good energy resolution in the 0.2-12 keV band.
Because of the radiation damage in orbit, however, the charge transfer
inefficiency (CTI) has increased, and hence the energy scale and resolution of
the XIS has been degraded since the launch of July 2005. The CCD has a charge
injection structure, and the CTI of each column and the pulse-height dependence
of the CTI are precisely measured by a checker flag charge injection (CFCI)
technique. Our precise CTI correction improved the energy resolution from 230
eV to 190 eV at 5.9 keV in December 2006. This paper reports the CTI
measurements with the CFCI experiments in orbit. Using the CFCI results, we
have implemented the time-dependent energy scale and resolution to the Suzaku
calibration database.
[8]
oai:arXiv.org:0807.1721 [pdf] - 14403
Physics of reverse annealing in high-resistivity Chandra ACIS CCDs
Submitted: 2008-07-10
After launch, the Advanced CCD Imaging Spectrometer (ACIS), a focal plane
instrument on the Chandra X-ray Observatory, suffered radiation damage from
exposure to soft protons during passages through the Earth's radiation belts.
An effect of the damage was to increase the charge transfer inefficiency (CTI)
of the front illuminated CCDs. As part of the initial damage assessment, the
focal plane was warmed from the operating temperature of -100C to +30C which
unexpectedly further increased the CTI. We report results of ACIS CCD
irradiation experiments in the lab aimed at better understanding this reverse
annealing process. Six CCDs were irradiated cold by protons ranging in energy
from 100 keV to 400 keV, and then subjected to simulated bakeouts in one of
three annealing cycles. We present results of these lab experiments, compare
them to our previous experiences on the ground and in flight, and derive limits
on the annealing time constants.
[9]
oai:arXiv.org:0705.1771 [pdf] - 1529986
Performance of the Charge Injection Capability of Suzaku XIS
Nakajima, H.;
Yamaguchi, H.;
Matsumoto, H.;
Tsuru, T. G.;
Koyama, K.;
Tsunemi, H.;
Hayashida, K.;
Torii, K.;
Namiki, M.;
Katsuda, S.;
Shoji, M.;
Matsuura, D.;
Miyauchi, T.;
Dotani, T.;
Ozaki, M.;
Murakami, H.;
Bautz, M. W.;
Kissel, S. E.;
LaMarr, B.;
Prigozhin, G. Y.
Submitted: 2007-05-12
A charge injection technique is applied to the X-ray CCD camera, XIS (X-ray
Imaging Spectrometer) onboard Suzaku. The charge transfer inefficiency (CTI) in
each CCD column (vertical transfer channel) is measured by the injection of
charge packets into a transfer channel and subsequent readout. This paper
reports the performances of the charge injection capability based on the ground
experiments using a radiation damaged device, and in-orbit measurements of the
XIS. The ground experiments show that charges are stably injected with the
dispersion of 91eV in FWHM in a specific column for the charges equivalent to
the X-ray energy of 5.1keV. This dispersion width is significantly smaller than
that of the X-ray events of 113eV (FWHM) at approximately the same energy. The
amount of charge loss during transfer in a specific column, which is measured
with the charge injection capability, is consistent with that measured with the
calibration source. These results indicate that the charge injection technique
can accurately measure column-dependent charge losses rather than the
calibration sources. The column-to-column CTI correction to the calibration
source spectra significantly reduces the line widths compared to those with a
column-averaged CTI correction (from 193eV to 173eV in FWHM on an average at
the time of one year after the launch). In addition, this method significantly
reduces the low energy tail in the line profile of the calibration source
spectrum.
[10]
oai:arXiv.org:astro-ph/0606178 [pdf] - 82618
Temperature dependence of charge transfer inefficiency in Chandra X-ray
CCDs
Submitted: 2006-06-07
Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the
focal plane instruments on the Chandra X-ray Observatory, suffered radiation
damage from exposure to soft protons during passages through the Earth's
radiation belts. The primary effect of the damage was to increase the charge
transfer inefficiency (CTI) of the eight front illuminated CCDs by more than
two orders of magnitude. The ACIS instrument team is continuing to study the
properties of the damage with an emphasis on developing techniques to mitigate
CTI and spectral resolution degradation. We present the initial temperature
dependence of ACIS CTI from -120 to -60 degrees Celsius and the current
temperature dependence after more than six years of continuing slow radiation
damage. We use the change of shape of the temperature dependence to speculate
on the nature of the damaging particles.
[11]
oai:arXiv.org:astro-ph/0509035 [pdf] - 75617
Long-term trends in radiation damage of Chandra X-ray CCDs
Submitted: 2005-09-01
Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the
focal plane instruments on the Chandra X-ray Observatory, suffered radiation
damage from exposure to soft protons during passages through the Earth's
radiation belts. Current operations require ACIS to be protected during
radiation belt passages to prevent this type of damage, but there remains a
much slower and more gradual increase. We present the history of ACIS charge
transfer inefficiency (CTI), and other measures of radiation damage, from
January 2000 through June 2005. The rate of CTI increase is low, of order 1e-6
per year, with no indication of step-function increases due to specific solar
events. Based on the time history and CCD location of the CTI increase, we
speculate on the nature of the damaging particles.
[12]
oai:arXiv.org:astro-ph/0407199 [pdf] - 66041
A charge transfer inefficiency correction model for the Chandra Advanced
CCD Imaging Spectrometer
Submitted: 2004-07-09
Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the
focal plane instruments on the Chandra X-ray Observatory, suffered radiation
damage from exposure to soft protons during passages through the Earth's
radiation belts. The primary effect of the damage was to increase the charge
transfer inefficiency (CTI) of the eight front illuminated CCDs by more than
two orders of magnitude. The ACIS instrument team is continuing to study the
properties of the damage with an emphasis on developing techniques to mitigate
CTI and spectral resolution degradation. We will discuss the characteristics of
the damage, the detector and the particle background and how they conspire to
degrade the instrument performance. We have developed a model for ACIS CTI
which can be used to correct each event and regain some of the lost
performance. The correction uses a map of the electron trap distribution, a
parameterization of the energy dependent charge loss and the fraction of the
lost charge re-emitted into the trailing pixel to correct the pixels in the
event island. This model has been implemented in the standard Chandra data
processing pipeline. Some of the correction algorithm was inspired by the
earlier work on ACIS CTI correction by Townsley et al. (2000; 2002). The
details of the CTI model and how each parameter improves performance will be
discussed, as well as the limitations and the possibilities for future
improvement.
[13]
oai:arXiv.org:astro-ph/0209126 [pdf] - 51532
Sacrificial charge and the spectral resolution performance of the
Chandra Advanced CCD Imaging Spectrometer
Submitted: 2002-09-06
Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the
focal plane instruments on the Chandra X-ray Observatory, suffered radiation
damage from exposure to soft protons during passages through the Earth's
radiation belts. The ACIS team is continuing to study the properties of the
damage with an emphasis on developing techniques to mitigate charge transfer
inefficiency (CTI) and spectral resolution degradation. A post-facto CTI
corrector has been developed which can effectively recover much of the lost
resolution. Any further improvements in performance will require knowledge of
the location and amount of sacrificial charge - charge deposited along the
readout path of an event which fills electron traps and changes CTI. We report
on efforts by the ACIS Instrument team to characterize which charge traps cause
performance degradation and the properties of the sacrificial charge seen
on-orbit. We also report on attempts to correct X-ray pulseheights for the
presence of sacrificial charge.
[14]
oai:arXiv.org:astro-ph/0112041 [pdf] - 46414
Analysis of On-Orbit ACIS Squeegee Mode Data on Chip I0
Submitted: 2001-12-03
The MIT and CXC ACIS teams have explored a number of measures to ameliorate
the effects of radiation damage suffered by the ACIS FI CCDs. One of these
measures is a novel CCD read-out method called ``squeegee mode''. A variety of
different implementations of the squeegee mode have now been tested on the I0
CCD.
Our results for the fitted FWHM at Al-K$\alpha$ and Mn-K$\alpha$ clearly
demonstrate that all the squeegee modes provide improved performance in terms
of reducing CTI and improving spectral resolution. Our analysis of the
detection efficiency shows that the so-called squeegee modes ``Vanilla'' and
``Maximum Observing Efficiency'' provide the same detection efficiency as the
standard clocking, once the decay in the intensity of the radioactive source
has been taken into account. The squeegee modes which utilize the slow parallel
transfer (``Maximum Spectral Resolution'', ``Maximum Angular Resolution'', and
``Sub-Array'') show a significantly lower detection efficiency than the
standard clocking. The slow parallel transfer squeegee modes exhibit severe
grade migration from flight grade 0 to flight grade 64 and a smaller migration
into ASCA g7. The latter effect can explain some of the drop in detection
efficiency. (ABRIDGED ABSTRACT)