Normalized to: Lacombe, K.
[1]
oai:arXiv.org:1909.09015 [pdf] - 1964273
Designing large pixelated CdTe detection planes for hard X-ray
transients detection
Lacombe, K.;
Amoros, C.;
Atteia, J. -L.;
Bajat, A.;
Bouchet, L.;
Dezalay, J. -P.;
Guillemot, P.;
Houret, B.;
Lebrun, F.;
Mate, S.;
Pons, R.;
Triou, H.;
Waegebaert, V.
Submitted: 2019-09-19
We discuss the need for very large detection planes for the detection of hard
X-ray transients in the multi-messenger era that started with the
quasi-simultaneous detection of GRB~170817A by \textit{Fermi}/GBM and
\textit{INTEGRAL}/SPI on one hand and the gravitational waves event GW 170817,
detected by the LVC collaboration, on the other hand. Then, we present a brief
survey of current and future instruments and their expected sensitivity,
pointing the fact that the gain in the number of GRBs is achieved by future
projects thanks to their larger field of view rather than to their larger
effective area. Based on our experience with \textit{SVOM}/ECLAIRs, we then
address various problems associated with the realization of very large
detection planes (\mbox{$\ge 1 \mathrm m^{2}$}), and we demonstrate that CdTe
detectors are well suited for this task. We conclude with a discussion of some
key parameters that must be taken into account in the realization of
instruments based on these detectors. We hope that this paper will motivate the
elaboration of detailed proposals of large area wide-field hard X-ray monitors
that will be crucially needed in the next decade.
[2]
oai:arXiv.org:1406.7759 [pdf] - 1215301
The X-/Gamma-ray camera ECLAIRs for the Gammay-ray burst mission SVOM
Godet, O.;
Nasser, G.;
Atteia, J. -L.;
Cordier, B.;
Mandrou, P.;
Barret, D.;
Triou, H.;
Pons, R.;
Amoros, C.;
Bordon, S.;
Gevin, O.;
Gonzalez, F.;
Götz, D.;
Gros, A.;
Houret, B.;
Lachaud, C.;
Lacombe, K.;
Marty, W.;
Mercier, K.;
Rambaud, D.;
Ramon, P.;
Rouaix, G.;
Schanne, S.;
Waegebaert, V
Submitted: 2014-06-30
We present ECLAIRs, the Gamma-ray burst (GRB) trigger camera to fly on-board
the Chinese-French mission SVOM. ECLAIRs is a wide-field ($\sim 2$\,sr) coded
mask camera with a mask transparency of 40\% and a 1024 $\mathrm{cm}^2$
detection plane coupled to a data processing unit, so-called UGTS, which is in
charge of locating GRBs in near real time thanks to image and rate triggers. We
present the instrument science requirements and how the design of ECLAIRs has
been optimized to increase its sensitivity to high-redshift GRBs and
low-luminosity GRBs in the local Universe, by having a low-energy threshold of
4 keV. The total spectral coverage ranges from 4 to 150 keV. ECLAIRs is
expected to detect $\sim 200$ GRBs of all types during the nominal 3 year
mission lifetime.
To reach a 4 keV low-energy threshold, the ECLAIRs detection plane is paved
with 6400 $4\times 4~\mathrm{mm}^2$ and 1 mm-thick Schottky CdTe detectors. The
detectors are grouped by 32, in 8x4 matrices read by a low-noise ASIC, forming
elementary modules called XRDPIX. In this paper, we also present our current
efforts to investigate the performance of these modules with their front-end
electronics when illuminated by charged particles and/or photons using
radioactive sources. All measurements are made in different instrument
configurations in vacuum and with a nominal in-flight detector temperature of
$-20^\circ$C. This work will enable us to choose the in-flight configuration
that will make the best compromise between the science performance and the
in-flight operability of ECLAIRs. We will show some highlights of this work.
[4]
oai:arXiv.org:1307.4545 [pdf] - 1941894
The NectarCAM camera project
Glicenstein, J-F.;
Barcelo, M.;
Barrio, J-A.;
Blanch, O.;
Boix, J.;
Bolmont, J.;
Boutonnet, C.;
Cazaux, S.;
Chabanne, E.;
Champion, C.;
Chateau, F.;
Colonges, S.;
Corona, P.;
Couturier, S.;
Courty, B.;
Delagnes, E.;
Delgado, C.;
Ernenwein, J-P.;
Fegan, S.;
Ferreira, O.;
Fesquet, M.;
Fontaine, G.;
Fouque, N.;
Henault, F.;
Gascón, D.;
Herranz, D.;
Hermel, R.;
Hoffmann, D.;
Houles, J.;
Karkar, S.;
Khelifi, B.;
Knödlseder, J.;
Martinez, G.;
Lacombe, K.;
Lamanna, G.;
LeFlour, T.;
Lopez-Coto, R.;
Louis, F.;
Mathieu, A.;
Moulin, E.;
Nayman, P.;
Nunio, F.;
Olive, J-F.;
Panazol, J-L.;
Petrucci, P-O.;
Punch, M.;
Prast, J.;
Ramon, P.;
Riallot, M.;
Ribó, M.;
Rosier-Lees, S.;
Sanuy, A.;
Siero, J.;
Tavernet, J-P.;
Tejedor, L. A.;
Toussenel, F.;
Vasileiadis, G.;
Voisin, V.;
Waegebert, V.;
Zurbach, C.
Submitted: 2013-07-17
In the framework of the next generation of Cherenkov telescopes, the
Cherenkov Telescope Array (CTA), NectarCAM is a camera designed for the medium
size telescopes covering the central energy range of 100 GeV to 30 TeV.
NectarCAM will be finely pixelated (~ 1800 pixels for a 8 degree field of view,
FoV) in order to image atmospheric Cherenkov showers by measuring the charge
deposited within a few nanoseconds time-window. It will have additional
features like the capacity to record the full waveform with GHz sampling for
every pixel and to measure event times with nanosecond accuracy. An array of a
few tens of medium size telescopes, equipped with NectarCAMs, will achieve up
to a factor of ten improvement in sensitivity over existing instruments in the
energy range of 100 GeV to 10 TeV. The camera is made of roughly 250
independent read-out modules, each composed of seven photo-multipliers, with
their associated high voltage base and control, a read-out board and a
multi-service backplane board. The read-out boards use NECTAr (New Electronics
for the Cherenkov Telescope Array) ASICs which have the dual functionality of
analogue memories and Analogue to Digital Converter (ADC). The camera trigger
to be used will be flexible so as to minimize the read-out dead-time of the
NECTAr chips. We present the camera concept and the design and tests of the
various subcomponents. The design includes the mechanical parts, the cooling of
the electronics, the readout, the data acquisition, the trigger, the monitoring
and services.
[5]
oai:arXiv.org:0809.1057 [pdf] - 16032
The Wide-Field X and Gamma-Ray Telescope ECLAIRs aboard the Gamma-Ray
Burst Multi-Wavelength Space Mission SVOM
Mandrou, P.;
Schanne, S.;
Cordier, B.;
Pons, R.;
Barret, D.;
Amoros, C.;
Lacombe, K.;
Fesquet, M.;
Limousin, O.;
Sizun, P.;
Lebrun, F.;
Gonzalez, F.;
Jouret, M.
Submitted: 2008-09-05
The X and Gamma-ray telescope ECLAIRs is foreseen to be launched on a low
Earth orbit (h=630 km, i=30 degrees) aboard the SVOM satellite (Space-based
multi-band astronomical Variable Objects Monitor), a French-Chinese mission
with Italian contribution. Observations are expected to start in 2013. It has
been designed to detect and localize Gamma-Ray Bursts (GRBs) or persistent
sources of the sky, thanks to its wide field of view (about 2 sr) and its
remarkable sensitivity in the 4-250 keV energy range, with enhanced imaging
sensitivity in the 4-70 keV energy band. These characteristics are well suited
to detect highly redshifted GRBs, and consequently to provide fast and accurate
triggers to other onboard or ground-based instruments able to follow-up the
detected events in a very short time from the optical wavelength bands up to
the few MeV Gamma-Ray domain.
[6]
oai:arXiv.org:astro-ph/0701423 [pdf] - 88552
Development of a modular CdTe detector plane for gamma-ray burst
detection below 100 keV
Ehanno, M.;
Amoros, C.;
Barret, D.;
Lacombe, K.;
Pons, R.;
Rouaix, G.;
Gevin, O.;
Limousin, O.;
Lugiez, F.;
Bardoux, A.;
Penquer, A.
Submitted: 2007-01-15
We report on the development of an innovative CdTe detector plane (DPIX)
optimized for the detection and localization of gamma-ray bursts in the X-ray
band (below 100 keV). DPIX is part of an R&D program funded by the French Space
Agency (CNES). DPIX builds upon the heritage of the ISGRI instrument, currently
operating with great success on the ESA INTEGRAL mission. DPIX is an assembly
of 200 elementary modules (XRDPIX) equipped with 32 CdTe Schottky detectors
(4x4 mm2, 1 mm thickness) produced by ACRORAD Co. LTD. in Japan. These
detectors offer good energy response up to 100 keV. Each XRDPIX is readout by
the very low noise front-end electronics chip IDeF-X, currently under
development at CEA/DSM/DAPNIA. In this paper, we describe the design of XRDPIX,
the main features of the IDeF-X chip, and will present preliminary results of
the reading out of one CdTe Schottky detector by the IDeF-X V1.0 chip. A
low-energy threshold around 2.7 keV has been measured. This is to be compared
with the 12-15 keV threshold of the ISGRI-INTEGRAL and BAT-SWIFT instruments,
which both use similar detector material.