Labèque, Alain
Normalized to: Labèque, A.
2 article(s) in total. 18 co-authors, from 1 to 2 common article(s). Median position in authors list is 6,0.
[1]
oai:arXiv.org:0812.1901 [pdf] - 19342
Tests of achromatic phase shifters performed on the SYNAPSE test bench:
a progress report
Gabor, Pavel;
Schuller, Peter A.;
Chazelas, Bruno;
Decaudin, Michel;
Labèque, Alain;
Duret, Philippe;
Rabbia, Yves;
Launhardt, Ralf;
Gay, Jean;
Sodnik, Zoran;
Barillot, Marc;
Brachet, Frank;
Laurent, Thomas;
Jacquinod, Sophie;
Vandormael, Denis;
Loicq, Jérôme;
Mawet, Dimitri;
Ollivier, Marc;
Léger, Alain
Submitted: 2008-12-10
The achromatic phase shifter (APS) is a component of the Bracewell nulling
interferometer studied in preparation for future space missions (viz.
Darwin/TPF-I) focusing on spectroscopic study of Earth-like exo-planets.
Several possible designs of such an optical subsystem exist. Four approaches
were selected for further study. Thales Alenia Space developed a dielectric
prism APS. A focus crossing APS prototype was developed by the OCA, Nice,
France. A field reversal APS prototype was prepared by the MPIA in Heidelberg,
Germany. Centre Spatial de Li\`ege develops a concept based on Fresnel's
rhombs. This paper presents a progress report on the current work aiming at
evaluating these prototypes on the SYNAPSE test bench at the Institut
d'Astrophysique Spatiale in Orsay, France.
[2]
oai:arXiv.org:0803.4438 [pdf] - 11344
Stabilising a nulling interferometer using optical path difference
dithering
Submitted: 2008-03-31
Context. Nulling interferometry has been suggested as the underlying
principle for the Darwin and TPF-I exoplanet research missions. Aims. There are
constraints both on the mean value of the nulling ratio, and on its stability.
Instrument instability noise is most detrimental to the stability of the
nulling performance. Methods. We applied a modified version of the classical
dithering technique to the optical path difference in the scientific beam.
Results. Using only this method, we repeatedly stabilised the dark fringe for
several hours. This method alone sufficed to remove the 1/ f component of the
noise in our setup for periods of 10 minutes, typically. These results indicate
that performance stability may be maintained throughout the long-duration data
acquisitions typical of exoplanet spectroscopy. Conclusions. We suggest that
further study of possible stabilisation strategies should be an integral part
of Darwin/TPF-I research and development