[1]  oai:arXiv.org:1612.03699  [pdf] - 1580870
Observation of photon noise by cold-electron bolometers
Comments: 5 pages, 8 figures
Submitted: 2016-12-12
We have measured a response to a black body radiation and noise of the cold-electron bolometers. The experimental results have been fitted by theoretical model with two heat-balance equations. The measured noise has been decomposed into several terms with the help of theory. It is demonstrated that the photon noise exceeds any other noise components, that allows us to conclude that the bolometers see the photon noise. Moreover, a peculiar shape of the noise dependence on the absorbed power originates completely from the photonic component according to the theory. In the additional experiment on heating of the cryostat plate together with the sample holder we have observed nearly independence of the noise on the electron temperature of the absorber, which has provided another proof of the presence of the photon noise in the first experiment.
[2]  oai:arXiv.org:1505.02618  [pdf] - 996791
A Frequency Selective Surface based focal plane receiver for the OLIMPO balloon-borne telescope
Comments:
Submitted: 2015-05-11
We describe here a focal plane array of Cold-Electron Bolometer (CEB) detectors integrated in a Frequency Selective Surface (FSS) for the 350 GHz detection band of the OLIMPO balloon-borne telescope. In our architecture, the two terminal CEB has been integrated in the periodic unit cell of the FSS structure and is impedance matched to the embedding impedance seen by it and provides a resonant interaction with the incident sub-mm radiation. The detector array has been designed to operate in background noise limited condition for incident powers of 20 pW to 80 pW, making it possible to use the same pixel in both photometric and spectrometric configurations. We present high frequency and dc simulations of our system, together with fabrication details. The frequency response of the FSS array, optical response measurements with hot/cold load in front of optical window and with variable temperature black body source inside cryostat are presented. A comparison of the optical response to the CEB model and estimations of Noise Equivalent power (NEP) is also presented.
[3]  oai:arXiv.org:1410.5870  [pdf] - 886482
Cold-electron bolometers for future mm and sub-mm sky surveys
Comments: 6 figures
Submitted: 2014-10-21
Future sky surveys in the mm/sub-mm range, like the forthcoming balloon-borne missions LSPE, OLIMPO, SPIDER etc., will need detectors insensitive to cosmic rays (CRs) and with a NEP of the order of $10^{-17} \div 10^{-18}\,$W/sqrt(Hz). The Cold-Electron Bolometers (CEBs) technology is promising, having the required properties, since the absorber volume is extremely small and the electron system of the absorber is thermally insulated from the phonon system. We have developed an experimental setup to test the optical performance and the CRs insensitivity of CEBs, with the target of integrating them in the OLIMPO and LSPE focal planes.
[4]  oai:arXiv.org:1403.7779  [pdf] - 804121
Sensitivity to Cosmic Rays of Cold Electron Bolometers for Space Applications
Comments: LTD15; 6 pages, 6 figures
Submitted: 2014-03-30
An important phenomenon limiting the sensitivity of bolometric detectors for future space missions is the interaction with cosmic rays. We tested the sensitivity of Cold Electron Bolometers (CEBs) to ionizing radiation using gamma-rays from a radioactive source and X-rays from a X-ray tube. We describe the test setup and the results. As expected, due to the effective thermal insulation of the sensing element and its negligible volume, we find that CEBs are largely immune to this problem.
[5]  oai:arXiv.org:astro-ph/0108491  [pdf] - 1327812
Submillimeter telescope for the Russian segment of the ISS: Submillimetron Project
Comments: 4 pages, 5 figures, ESA SP-460 in press
Submitted: 2001-08-30
The Submillimetron is the international project of the space telescope for astronomical studies at the submillimeter and infrared wavelengths using facilities of the Russian segment of the International Space Station (ISS). The concept of the telescope includes a 60 cm mirror cooled to liquid helium temperature with a novel type of microbolometers arrays using effects of superconductivity. This combination gives unique possibility to realize background limited sensitivity in the spectral minimum of the extraterrestrial background near frequency 1 THz between peaks of galactic dust emission and CMB. The angular resolution about 1 arcmin, field of view about 1 degree, and optics are similar to IRAS satellite, but the sensitivity is better on more than order of magnitude for about 10^-18 W/Hz^-1/2. This improvement and another spectral region permits to reveal in full sky survey considerably more new astrophysical objects. The concept of free flying instrument with periodic docking to ISS gives possibility to combine low cost with reliability, refilling, repairment and maintenance.