Normalized to: Kurosawa, S.
[1]
oai:arXiv.org:1703.07600 [pdf] - 1564143
Imaging Polarimeter for a Sub-MeV Gamma-Ray All-Sky Survey using an
Electron-Tracking Compton Camera
Komura, Shotaro;
Takada, Atsushi;
Mizumura, Yoshitaka;
Miyamoto, Shohei;
Takemura, Taito;
Kishimoto, Tetsuro;
Kubo, Hidetoshi;
Kurosawa, Shunsuke;
Matsuoka, Yoshihiro;
Miuchi, Kentaro;
Mizumoto, Tetsuya;
Nakamasu, Yuma;
Nakamura, Kiseki;
Oda, Makoto;
Parker, Joseph D.;
Sawano, Tatsuya;
Sonoda, Shinya;
Tanimori, Toru;
Tomono, Dai;
Yoshikawa, Kei
Submitted: 2017-03-22
X-ray and gamma-ray polarimetry is a promising tool to study the geometry and
the magnetic configuration of various celestial objects, such as binary black
holes or gamma-ray bursts (GRBs). However, statistically significant
polarizations have been detected in few of the brightest objects. Even though
future polarimeters using X-ray telescopes are expected to observe weak
persistent sources, there are no effective approaches to survey transient and
serendipitous sources with a wide field of view (FoV). Here we present an
electron-tracking Compton camera (ETCC) as a highly-sensitive gamma-ray imaging
polarimeter. The ETCC provides powerful background rejection and a high
modulation factor over a FoV of up to 2$\pi$ sr thanks to its excellent imaging
based on a well-defined point spread function. Importantly, we demonstrated for
the first time the stability of the modulation factor under realistic
conditions of off-axis incidence and huge backgrounds using the SPring-8
polarized X-ray beam. The measured modulation factor of the ETCC was 0.65 $\pm$
0.01 at 150 keV for an off-axis incidence with an oblique angle of 30$^\circ$
and was not degraded compared to the 0.58 $\pm$ 0.02 at 130 keV for on-axis
incidence. These measured results are consistent with the simulation results.
Consequently, we found that the satellite-ETCC proposed in Tanimori et al.
(2015) would provide all-sky surveys of weak persistent sources of 13 mCrab
with 10% polarization for a 10$^{7}$ s exposure and over 20 GRBs down to a
$6\times10^{-6}$ erg cm$^{-2}$ fluence and 10% polarization during a one-year
observation.
[2]
oai:arXiv.org:1702.01483 [pdf] - 1535425
Establishment of Imaging Spectroscopy of Nuclear Gamma-Rays based on
Geometrical Optics
Tanimori, Toru;
Mizumura, Yoshitaka;
Takada, Atsushi;
Miyamoto, Shohei;
Takemura, Taito;
Kishimoto, Tetsuro;
Komura, Shotaro;
Kubo, Hidetoshi;
Kurosawa, Shunsuke;
Matsuoka, Yoshihiro;
Miuchi, Kentaro;
Mizumoto, Tetsuya;
Nakamasu, Yuma;
Nakamura, Kiseki;
Parker, Joseph D.;
Sawano, Tatsuya;
Sonoda, Shinya;
Tomono, Dai;
Yoshikawa, Kei
Submitted: 2017-02-05
Since the discovery of nuclear gamma-rays, its imaging has been limited to
pseudo imaging, such as Compton Camera (CC) and coded mask. Pseudo imaging does
not keep physical information (intensity, or brightness in Optics) along a ray,
and thus is capable of no more than qualitative imaging of bright objects. To
attain quantitative imaging, cameras that realize geometrical optics is
essential, which would be, for nuclear MeV gammas, only possible via complete
reconstruction of the Compton process. Recently we have revealed that "Electron
Tracking Compton Camera" (ETCC) provides a well-defined Point Spread Function
(PSF). The information of an incoming gamma is kept along a ray with the PSF
and that is equivalent to geometrical optics. Here we present an
imaging-spectroscopic measurement with the ETCC. Our results highlight the
intrinsic difficulty with CCs in performing accurate imaging, and show that the
ETCC surmounts this problem. The imaging capability also helps the ETCC
suppress the noise level dramatically by ~3 orders of magnitude without a
shielding structure. Furthermore, full reconstruction of Compton process with
the ETCC provides spectra free of Compton edges. These results mark the first
proper imaging of nuclear gammas based on the genuine geometrical optics.
[3]
oai:arXiv.org:1508.00990 [pdf] - 1268655
New readout and data-acquisition system in an electron-tracking Compton
camera for MeV gamma-ray astronomy (SMILE-II)
Mizumoto, Tetsuya;
Matsuoka, Yoshihiro;
Mizumura, Yoshitaka;
Tanimori, Toru;
Kubo, Hidetoshi;
Takada, Atsushi;
Iwaki, Satoru;
Sawano, Tatsuya;
Nakamura, Kiseki;
Komura, Shotaro;
Nakamura, Shogo;
Kishimoto, Tetsuro;
Oda, Makoto;
Miyamoto, Shohei;
Takemura, Taito;
Parker, Joseph D.;
Tomono, Dai;
Sonoda, Shinya;
Miuchi, Kentaro;
Kurosawa, Shunsuke
Submitted: 2015-08-05, last modified: 2015-08-29
For MeV gamma-ray astronomy, we have developed an electron-tracking Compton
camera (ETCC) as a MeV gamma-ray telescope capable of rejecting the radiation
background and attaining the high sensitivity of near 1 mCrab in space. Our
ETCC comprises a gaseous time-projection chamber (TPC) with a micro pattern gas
detector for tracking recoil electrons and a position-sensitive scintillation
camera for detecting scattered gamma rays. After the success of a first balloon
experiment in 2006 with a small ETCC (using a 10$\times$10$\times$15 cm$^3$
TPC) for measuring diffuse cosmic and atmospheric sub-MeV gamma rays (Sub-MeV
gamma-ray Imaging Loaded-on-balloon Experiment I; SMILE-I), a (30 cm)$^{3}$
medium-sized ETCC was developed to measure MeV gamma-ray spectra from celestial
sources, such as the Crab Nebula, with single-day balloon flights (SMILE-II).
To achieve this goal, a 100-times-larger detection area compared with that of
SMILE-I is required without changing the weight or power consumption of the
detector system. In addition, the event rate is also expected to dramatically
increase during observation. Here, we describe both the concept and the
performance of the new data-acquisition system with this (30 cm)$^{3}$ ETCC to
manage 100 times more data while satisfying the severe restrictions regarding
the weight and power consumption imposed by a balloon-borne observation. In
particular, to improve the detection efficiency of the fine tracks in the TPC
from $\sim$10\% to $\sim$100\%, we introduce a new data-handling algorithm in
the TPC. Therefore, for efficient management of such large amounts of data, we
developed a data-acquisition system with parallel data flow.
[4]
oai:arXiv.org:1507.03850 [pdf] - 1267930
An Electron-Tracking Compton Telescope for a Survey of the Deep Universe
by MeV gamma-rays
Tanimori, T.;
Kubo, H.;
Takada, A.;
Iwaki, S.;
Komura, S.;
Kurosawa, S.;
Matsuoka, Y.;
Miuchi, K.;
Miyamoto, S.;
Mizumoto, T.;
Mizumura, Y.;
Nakamura, K.;
Nakamura, S.;
Oda, M.;
Parker, J. D.;
Sawano, T.;
Sonoda, S.;
Takemura, T.;
Tomono, D.;
Ueno, K.
Submitted: 2015-07-14, last modified: 2015-08-04
Photon imaging for MeV gammas has serious difficulties due to huge
backgrounds and unclearness in images, which are originated from incompleteness
in determining the physical parameters of Compton scattering in detection,
e.g., lack of the directional information of the recoil electrons. The recent
major mission/instrument in the MeV band, Compton Gamma Ray
Observatory/COMPTEL, which was Compton Camera (CC), detected mere $\sim30$
persistent sources. It is in stark contrast with $\sim$2000 sources in the GeV
band. Here we report the performance of an Electron-Tracking Compton Camera
(ETCC), and prove that it has a good potential to break through this stagnation
in MeV gamma-ray astronomy. The ETCC provides all the parameters of
Compton-scattering by measuring 3-D recoil electron tracks; then the Scatter
Plane Deviation (SPD) lost in CCs is recovered. The energy loss rate (dE/dx),
which CCs cannot measure, is also obtained, and is found to be indeed helpful
to reduce the background under conditions similar to space. Accordingly the
significance in gamma detection is improved severalfold. On the other hand, SPD
is essential to determine the point-spread function (PSF) quantitatively. The
SPD resolution is improved close to the theoretical limit for multiple
scattering of recoil electrons. With such a well-determined PSF, we demonstrate
for the first time that it is possible to provide reliable sensitivity in
Compton imaging without utilizing an optimization algorithm. As such, this
study highlights the fundamental weak-points of CCs. In contrast we demonstrate
the possibility of ETCC reaching the sensitivity below $1\times10^{-12}$ erg
cm$^{-2}$ s$^{-1}$ at 1 MeV.
[5]
oai:arXiv.org:1412.3918 [pdf] - 1223621
Performance of a new electron-tracking Compton camera under intense
radiations from a water target irradiated with a proton beam
Matsuoka, Yoshihiro;
Tanimori, T.;
Kubo, H.;
Takada, A.;
Parker, J. D.;
Mizumoto, T.;
Mizumura, Y.;
Iwaki, S.;
Sawano, T.;
Komura, S.;
Kishimoto, T.;
Oda, M.;
Takemura, T.;
Miyamoto, S.;
Sonoda, S.;
Tomono, D.;
Miuchi, K.;
Kabuki, S.;
Kurosawa, S.
Submitted: 2014-12-12, last modified: 2015-01-22
We have developed an electron-tracking Compton camera (ETCC) for use in
next-generation MeV gamma ray telescopes. An ETCC consists of a gaseous time
projection chamber (TPC) and pixel scintillator arrays (PSAs). Since the TPC
measures the three dimensional tracks of Compton-recoil electrons, the ETCC can
completely reconstruct the incident gamma rays. Moreover, the ETCC demonstrates
efficient background rejection power in Compton-kinematics tests, identifies
particle from the energy deposit rate (dE/dX) registered in the TPC, and
provides high quality imaging by completely reconstructing the Compton
scattering process. We are planning the "Sub-MeV gamma ray Imaging
Loaded-on-balloon Experiment" (SMILE) for our proposed all-sky survey
satellite. Performance tests of a mid-sized 30 cm-cubic ETCC, constructed for
observing the Crab nebula, are ongoing. However, observations at balloon
altitudes or satellite orbits are obstructed by radiation background from the
atmosphere and the detector itself. The background rejection power was checked
using proton accelerator experiments conducted at the Research Center for
Nuclear Physics, Osaka University. To create the intense radiation fields
encountered in space, which comprise gamma rays, neutrons, protons, and other
energetic entities, we irradiated a water target with a 140 MeV proton beam and
placed a SMILE-II ETCC near the target. In this situation, the counting rate
was five times than that expected at the balloon altitude. Nonetheless, the
ETCC stably operated and identified particles sufficiently to obtain a clear
gamma ray image of the checking source. Here, we report the performance of our
detector and demonstrate its effective background rejection based in electron
tracking experiments.
[6]
oai:arXiv.org:1406.4202 [pdf] - 1215007
High-z gamma-ray bursts for unraveling the dark ages mission HiZ-GUNDAM
Yonetoku, Daisuke;
Mihara, Tatehiro;
Sawano, Tatsuya;
Ikeda, Hirokazu;
Harayama, Atsushi;
Takata, Shunsuke;
Yoshida, Kazuki;
Seta, Hiroki;
Toyanago, Asuka;
Kagawa, Yasuaki;
Kawai, Kentaro;
Kawai, Nobuyuki;
Sakamoto, Takanori;
Serino, Motoko;
Kurosawa, Shunsuke;
Gunji, Shuichi;
Tanimori, Toru;
Murakami, Toshio;
Yatsu, Yoichi;
Yamaoka, Kazutaka;
Yoshida, Atsumasa;
Kawabata, Koji;
Matsumoto, Toshio;
Tsumura, Koji;
Matsuura, Shuji;
Shirahata, Mai;
Okita, Hirofumi;
Yanagisawa, Kensi;
Yoshida, Michitoshi;
Motohara, Kentaro;
group, HiZ-GUNDAM working
Submitted: 2014-06-16
We are now investigating and studying a small satellite mission HiZ-GUNDAM
for future observation of gamma-ray bursts (GRBs). The mission concept is to
probe "the end of dark ages and the dawn of formation of astronomical objects",
i.e. the physical condition of early universe beyond the redshift z > 7. We
will consider two kinds of mission payloads, (1) wide field X-ray imaging
detectors for GRB discovery, and (2) a near infrared telescope with 30 cm in
diameter to select the high-z GRB candidates effectively. In this paper, we
explain some requirements to promote the GRB cosmology based on the past
observations, and also introduce the mission concept of HiZ-GUNDAM and basic
development of X-ray imaging detectors.
[7]
oai:arXiv.org:1312.0438 [pdf] - 829396
Development of a 30 cm-cube Electron-Tracking Compton Camera for the
SMILE-II Experiment
Mizumura, Y.;
Tanimori, T.;
Kubo, H.;
Takada, A.;
Parker, J. D.;
Mizumoto, T.;
Sonoda, S.;
Tomono, D.;
Sawano, T.;
Nakamura, K.;
Matsuoka, Y.;
Komura, S.;
Nakamura, S.;
Oda, M.;
Miuchi, K.;
Kabuki, S.;
Kishimoto, Y.;
Kurosawa, S.;
Iwaki, S.
Submitted: 2013-12-02, last modified: 2014-02-07
To explore the sub-MeV/MeV gamma-ray window for astronomy, we have developed
the Electron-Tracking Compton Camera (ETCC), and carried out the first
performance test at room condition using several gamma-ray sources in the
sub-MeV energy band. Using a simple track analysis for a quick first test of
the performance, the gamma-ray imaging capability was demonstrated by clear
images and 5.3 degrees of angular resolution measure (ARM) measured at 662 keV.
As the greatest impact of this work, a gamma-ray detection efficiency on the
order of $10^{-4}$ was achieved at the sub-MeV gamma-ray band, which is one
order of magnitude higher than our previous experiment. This angular resolution
and detection efficiency enables us to detect the Crab Nebula at the 5 sigma
level with several hours observation at balloon altitude in middle latitude.
Furthermore, good consistency of efficiencies between this performance test and
simulation including only physical processes has a large importance; it means
we achieve nearly 100% detection of Compton recoil electrons. Thus, our
estimation of enhancements by upgrades of the detector is more dependable. We
are planning to confirm the imaging capability of the ETCC by observation of
celestial objects in the SMILE-II (Sub-MeV gamma ray Imaging Loaded-on-balloon
Experiment II). The SMILE-II and following SMILE-III project will be an
important key of sub-MeV/MeV gamma-ray astronomy.
[8]
oai:arXiv.org:1103.3436 [pdf] - 966507
Observation of Diffuse Cosmic and Atmospheric Gamma Rays at Balloon
Altitudes with an Electron-tracking Compton Camera
Takada, Atsushi;
Kubo, Hidetoshi;
Nishimura, Hironobu;
Ueno, Kazuki;
Hattori, Kaori;
Kabuki, Shigeto;
Kurosawa, Shunsuke;
Miuchi, Kentaro;
Mizuta, Eiichi;
Nagayoshi, Tsutomu;
Nonaka, Naoki;
Okada, Yoko;
Orito, Reiko;
Sekiya, Hiroyuki;
Takeda, Atsushi;
Tanimori, Toru
Submitted: 2011-03-17, last modified: 2011-03-23
We observed diffuse cosmic and atmospheric gamma rays at balloon altitudes
with the Sub-MeV gamma-ray Imaging Loaded-on-balloon Experiment I (SMILE-I) as
the first step toward a future all-sky survey with a high sensitivity. SMILE-I
employed an electron-tracking Compton camera comprised of a gaseous electron
tracker as a Compton-scattering target and a scintillation camera as an
absorber. The balloon carrying the SMILE-I detector was launched from the
Sanriku Balloon Center of the Institute of Space and Astronomical Science/Japan
Space Exploration Agency on September 1, 2006, and the flight lasted for 6.8
hr, including level flight for 4.1 hr at an altitude of 32-35 km. During the
level flight, we successfully detected 420 downward gamma rays between 100 keV
and 1 MeV at zenith angles below 60 degrees. To obtain the flux of diffuse
cosmic gamma rays, we first simulated their scattering in the atmosphere using
Geant4, and for gamma rays detected at an atmospheric depth of 7.0 g cm-2, we
found that 50% and 21% of the gamma rays at energies of 150 keV and 1 MeV,
respectively, were scattered in the atmosphere prior to reaching the detector.
Moreover, by using Geant4 simulations and the QinetiQ atmospheric radiation
model, we estimated that the detected events consisted of diffuse cosmic and
atmospheric gamma rays (79%), secondary photons produced in the instrument
through the interaction between cosmic rays and materials surrounding the
detector (19%), and other particles (2%). The obtained growth curve was
comparable to Ling's model, and the fluxes of diffuse cosmic and atmospheric
gamma rays were consistent with the results of previous experiments. The
expected detection sensitivity of a future SMILE experiment measuring gamma
rays between 150 keV and 20 MeV was estimated from our SMILE-I results and was
found to be ten times better than that of other experiments at around 1 MeV.
[9]
oai:arXiv.org:1002.1794 [pdf] - 1025066
First underground results with NEWAGE-0.3a direction-sensitive dark
matter detector
Miuchi, Kentaro;
Nishimura, Hironobu;
Hattori, Kaori;
Higashi, Naoki;
Ida, Chihiro;
Iwaki, Satoshi;
Kabuki, Shigeto;
Kubo, Hidetoshi;
Kurosawa, Shunsuke;
Nakamura, Kiseki;
Parker, Joseph;
Sawano, Tatsuya;
Takahashi, Michiaki;
Tanimori, Toru;
Taniue, Kojiro;
Ueno, Kazuki;
Sekiya, Hiroyuki;
Takeda, Atsushi;
Tsuchiya, Ken'ichi;
Takada, Atsushi
Submitted: 2010-02-09
A direction-sensitive dark matter search experiment at Kamioka underground
laboratory with the NEWAGE-0.3a detector was performed. The NEWAGE- 0.3a
detector is a gaseous micro-time-projection chamber filled with CF4 gas at 152
Torr. The fiducial volume and target mass are 20*25*31 cm3 and 0.0115 kg,
respectively. With an exposure of 0.524 kgdays, improved spin-dependent weakly
interacting massive particle (WIMP)-proton cross section limits by a
direction-sensitive method were achieved including a new record of 5400 pb for
150 GeV/c2 WIMPs. We studied the remaining background and found that ambient
gamma-rays contributed about one-fifth of the remaining background and
radioactive contaminants inside the gas chamber contributed the rest.
[10]
oai:arXiv.org:0911.0323 [pdf] - 902277
The case for a directional dark matter detector and the status of
current experimental efforts
Ahlen, S.;
Afshordi, N.;
Battat, J. B. R.;
Billard, J.;
Bozorgnia, N.;
Burgos, S.;
Caldwell, T.;
Carmona, J. M.;
Cebrian, S.;
Colas, P.;
Dafni, T.;
Daw, E.;
Dujmic, D.;
Dushkin, A.;
Fedus, W.;
Ferrer, E.;
Finkbeiner, D.;
Fisher, P. H.;
Forbes, J.;
Fusayasu, T.;
Galan, J.;
Gamble, T.;
Ghag, C.;
Giomataris, I.;
Gold, M.;
Gomez, H.;
Gomez, M. E.;
Gondolo, P.;
Green, A.;
Grignon, C.;
Guillaudin, O.;
Hagemann, C.;
Hattori, K.;
Henderson, S.;
Higashi, N.;
Ida, C.;
Iguaz, F. J.;
Inglis, A.;
Irastorza, I. G.;
Iwaki, S.;
Kaboth, A.;
Kabuki, S.;
Kadyk, J.;
Kallivayalil, N.;
Kubo, H.;
Kurosawa, S.;
Kudryavtsev, V. A.;
Lamy, T.;
Lanza, R.;
Lawson, T. B.;
Lee, A.;
Lee, E. R.;
Lin, T.;
Loomba, D.;
Lopez, J.;
Luzon, G.;
Manobu, T.;
Martoff, J.;
Mayet, F.;
Mccluskey, B.;
Miller, E.;
Miuchi, K.;
Monroe, J.;
Morgan, B.;
Muna, D.;
Murphy, A. St. J.;
Naka, T.;
Nakamura, K.;
Nakamura, M.;
Nakano, T.;
Nicklin, G. G.;
Nishimura, H.;
Niwa, K.;
Paling, S. M.;
Parker, J.;
Petkov, A.;
Pipe, M.;
Pushkin, K.;
Robinson, M.;
Rodriguez, A.;
Rodriguez-Quintero, J.;
Sahin, T.;
Sanderson, R.;
Sanghi, N.;
Santos, D.;
Sato, O.;
Sawano, T.;
Sciolla, G.;
Sekiya, H.;
Slatyer, T. R.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Sugiyama, A.;
Takada, A.;
Takahashi, M.;
Takeda, A.;
Tanimori, T.;
Taniue, K.;
Tomas, A.;
Tomita, H.;
Tsuchiya, K.;
Turk, J.;
Tziaferi, E.;
Ueno, K.;
Vahsen, S.;
Vanderspek, R.;
Vergados, J.;
Villar, J. A.;
Wellenstein, H.;
Wolfe, I.;
Yamamoto, R. K.;
Yegoryan, H.
Submitted: 2009-11-01
We present the case for a dark matter detector with directional sensitivity.
This document was developed at the 2009 CYGNUS workshop on directional dark
matter detection, and contains contributions from theorists and experimental
groups in the field. We describe the need for a dark matter detector with
directional sensitivity; each directional dark matter experiment presents their
project's status; and we close with a feasibility study for scaling up to a one
ton directional detector, which would cost around $150M.
[11]
oai:arXiv.org:0708.2579 [pdf] - 4090
Direction-sensitive dark matter search results in a surface laboratory
Miuchi, Kentaro;
Hattori, Kaori;
Kabuki, Shigeto;
Kubo, Hidetoshi;
Kurosawa, Shunsuke;
Nishimura, Hironobu;
Okada, Yoko;
Takada, Atsushi;
Tanimori, Toru;
Tsuchiya, Ken'ichi;
Ueno, Kazuki;
Sekiya, Hiroyuki;
Takeda, Atsushi
Submitted: 2007-08-19
We developed a three-dimensional gaseous tracking device and performed a
direction-sensitive dark matter search in a surface laboratory. By using 150
Torr carbon-tetrafluoride (CF_4 gas), we obtained a sky map drawn with the
recoil directions of the carbon and fluorine nuclei, and set the first limit on
the spin-dependent WIMP (Weakly Interacting Massive Particles)-proton cross
section by a direction-sensitive method. Thus, we showed that a WIMP-search
experiment with a gaseous tracking device can actually set limits. Furthermore,
we demonstrated that this method will potentially play a certain role in
revealing the nature of dark matter when a low-background large-volume detector
is developed.