sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Kuroda, Yoshikatsu

Normalized to: Kuroda, Y.

7 article(s) in total. 128 co-authors, from 1 to 4 common article(s). Median position in authors list is 12,0.

[1]  oai:arXiv.org:1601.06349  [pdf] - 1407089
Observation of gamma ray bursts at ground level under the thunderclouds
Comments: 16 pages, 7 figures; Accepted for publication in Physics Letters B; Figure 5 added, some minor changes in the text
Submitted: 2016-01-24, last modified: 2016-05-12
We observed three $\gamma$-ray bursts related to thunderclouds in winter using the prototype of anti-neutrino detector PANDA made of 360-kg plastic scintillator deployed at Ohi Power Station at the coastal area of the Japan Sea. The maximum rate of the events which deposited the energy higher than $3\,$MeV was $(5.5 \pm 0.1) \times 10^2 {\rm /s}$. Monte Carlo simulation showed that electrons with approximately monochromatic energy falling downwards from altitudes of order $100\,$m roughly produced the observed total energy spectra of the bursts. It is supposed that secondary cosmic-ray electrons, which act as seed, were accelerated in electric field of thunderclouds and multiplied by relativistic runaway electron avalanche. We actually found that the $\gamma$-rays of the bursts entered into the detector from the direction close to the zenith. The direction stayed constant during the burst within the detector resolution. In addition, taking advantage of the delayed coincidence detection of the detector, we found neutron events in one of the bursts at the maximum rate of $\sim 14\pm5\,{\rm /s}$.
[2]  oai:arXiv.org:1509.00588  [pdf] - 1270723
The Si/CdTe semiconductor Compton camera of the ASTRO-H Soft Gamma-ray Detector (SGD)
Comments: 12 pages, 14 figures
Submitted: 2015-09-02
The Soft Gamma-ray Detector (SGD) is one of the instrument payloads onboard ASTRO-H, and will cover a wide energy band (60--600 keV) at a background level 10 times better than instruments currently in orbit. The SGD achieves low background by combining a Compton camera scheme with a narrow field-of-view active shield. The Compton camera in the SGD is realized as a hybrid semiconductor detector system which consists of silicon and cadmium telluride (CdTe) sensors. The design of the SGD Compton camera has been finalized and the final prototype, which has the same configuration as the flight model, has been fabricated for performance evaluation. The Compton camera has overall dimensions of 12 cm x 12 cm x 12 cm, consisting of 32 layers of Si pixel sensors and 8 layers of CdTe pixel sensors surrounded by 2 layers of CdTe pixel sensors. The detection efficiency of the Compton camera reaches about 15% and 3% for 100 keV and 511 keV gamma rays, respectively. The pixel pitch of the Si and CdTe sensors is 3.2 mm, and the signals from all 13312 pixels are processed by 208 ASICs developed for the SGD. Good energy resolution is afforded by semiconductor sensors and low noise ASICs, and the obtained energy resolutions with the prototype Si and CdTe pixel sensors are 1.0--2.0 keV (FWHM) at 60 keV and 1.6--2.5 keV (FWHM) at 122 keV, respectively. This results in good background rejection capability due to better constraints on Compton kinematics. Compton camera energy resolutions achieved with the final prototype are 6.3 keV (FWHM) at 356 keV and 10.5 keV (FWHM) at 662 keV, respectively, which satisfy the instrument requirements for the SGD Compton camera (better than 2%). Moreover, a low intrinsic background has been confirmed by the background measurement with the final prototype.
[3]  oai:arXiv.org:1401.7398  [pdf] - 903397
HI, CO, and Planck/IRAS dust properties in the high-latitude-cloud complex, MBM 53, 54, 55 and HLCG 92-35; Possible evidence for an optically thick HI envelope around the CO clouds
Comments:
Submitted: 2014-01-28, last modified: 2014-11-20
We present an analysis of the HI and CO gas in conjunction with the Planck/IRAS submillimeter/far-infrared dust properties toward the most outstanding high latitude clouds MBM 53, 54, 55 and HLCG 92-35 at b = -30 deg to -45 deg. The CO emission, dust opacity at 353 GHz (tau353), and dust temperature (Td) show generally good spatial correspondence. On the other hand, the correspondence between the HI emission and the dust properties is less clear than in CO. The integrated HI intensity WHI and tau353 show a large scatter with a correlation coefficient of ~0.6 for a Td range from 16 K to 22 K. We find, however, that WHI and tau353 show better correlation for smaller ranges of Td every 0.5 K, generally with a correlation coefficient of 0.7-0.9. We set up a hypothesis that the HI gas associated with the highest Td >= 21.5 K is optically thin, whereas the HI emission is generally optically thick for Td lower than 21.5 K. We have determined a relationship for the optically thin HI gas between atomic hydrogen column density and tau353, NHI (cm-2) = (1.5 x 10^26) x tau353, under the assumption that the dust properties are uniform and we have applied this to estimate NHI from tau353 for the whole cloud. NHI was then used to solve for Ts and tauHI over the region. The result shows that the HI is dominated by optically thick gas having a low spin temperature of 20-40 K and a density of 40-160 cm-3. The HI envelope has a total mass of ~1.2 x 10^4 Msol, an order of magnitude larger than that of the CO clouds. The HI envelope properties derived by this method do not rule out a mixture of HI and H2 in the dark gas, but we present indirect evidence that most of the gas mass is in the atomic state.
[4]  oai:arXiv.org:1306.2090  [pdf] - 1171908
Molecular Clouds Toward the Super Star Cluster NGC3603; Possible Evidence for a Cloud-Cloud Collision in Triggering the Cluster Formation
Comments: submitted to ApJ
Submitted: 2013-06-09, last modified: 2013-06-10
We present new large field observations of molecular clouds with NANTEN2 toward the super star cluster NGC3603 in the transitions 12CO(J=2-1, J=1-0) and 13CO(J=2-1, J=1-0). We suggest that two molecular clouds at 13 km s-1 and 28 km s-1 are associated with NGC3603 as evidenced by higher temperatures toward the H II region as well as morphological correspondence. The mass of the clouds is too small to gravitationally bind them, given their relative motion of ~20 km s-1. We suggest that the two clouds collided with each other a Myr ago to trigger the formation of the super star cluster. This scenario is able to explain the origin of the highest mass stellar population in the cluster which is as young as a Myr and is segregated within the central sub-pc of the cluster. This is the second super star cluster along side Westerlund2 where formation may have been triggered by a cloud-cloud collision.
[5]  oai:arXiv.org:0811.0415  [pdf] - 18145
High energy resolution hard X-ray and gamma-ray imagers using CdTe diode devices
Comments: 6 pages, 10 figures, accepted for publication in IEEE Transactions on Nuclear Science
Submitted: 2008-11-03
We developed CdTe double-sided strip detectors (DSDs or cross strip detectors) and evaluated their spectral and imaging performance for hard X-rays and gamma-rays. Though the double-sided strip configuration is suitable for imagers with a fine position resolution and a large detection area, CdTe diode DSDs with indium (In) anodes have yet to be realized due to the difficulty posed by the segmented In anodes. CdTe diode devices with aluminum (Al) anodes were recently established, followed by a CdTe device in which the Al anodes could be segmented into strips. We developed CdTe double-sided strip devices having Pt cathode strips and Al anode strips, and assembled prototype CdTe DSDs. These prototypes have a strip pitch of 400 micrometer. Signals from the strips are processed with analog ASICs (application specific integrated circuits). We have successfully performed gamma-ray imaging spectroscopy with a position resolution of 400 micrometer. Energy resolution of 1.8 keV (FWHM: full width at half maximum) was obtained at 59.54 keV. Moreover, the possibility of improved spectral performance by utilizing the energy information of both side strips was demonstrated. We designed and fabricated a new analog ASIC, VA32TA6, for the readout of semiconductor detectors, which is also suitable for DSDs. A new feature of the ASIC is its internal ADC function. We confirmed this function and good noise performance that reaches an equivalent noise charge of 110 e- under the condition of 3-4 pF input capacitance.
[6]  oai:arXiv.org:0711.2715  [pdf] - 1530010
In Orbit Timing Calibration of the Hard X-Ray Detector on Board Suzaku
Comments: Accepted for publication on PASJ Vol.60, SP-1, 2008
Submitted: 2007-11-16
The hard X-ray detector (HXD) on board the X-ray satellite Suzaku is designed to have a good timing capability with a 61 $\mu$s time resolution. In addition to detailed descriptions of the HXD timing system, results of in-orbit timing calibration and performance of the HXD are summarized. The relative accuracy of time measurements of the HXD event was confirmed to have an accuracy of $1.9\times 10^{-9}$ s s$^{-1}$ per day, and the absolute timing was confirmed to be accurate to 360 $\mu$s or better. The results were achieved mainly through observations of the Crab pulsar, including simultaneous ones with RXTE, INTEGRAL, and Swift.
[7]  oai:arXiv.org:astro-ph/0611232  [pdf] - 1233970
Hard X-ray Detector (HXD) on Board Suzaku
Comments: 35 pages, 25 figures and 4 tables; acceted for Publication of the Astronomical Society of Japan
Submitted: 2006-11-07
The Hard X-ray Detector (HXD) on board Suzaku covers a wide energy range from 10 keV to 600 keV by combination of silicon PIN diodes and GSO scintillators. The HXD is designed to achieve an extremely low in-orbit back ground based on a combination of new techniques, including the concept of well-type active shield counter. With an effective area of 142 cm^2 at 20 keV and 273 cm2 at 150 keV, the background level at the sea level reached ~1x10^{-5} cts s^{-1} cm^{-2} keV^{-1} at 30 keV for the PI N diodes, and ~2x10^{-5} cts s^{-1} cm^{-2} keV^{-1} at 100 keV, and ~7x10^{-6} cts s^{-1} cm^{-2} keV^{-1} at 200 keV for the phoswich counter. Tight active shielding of the HXD results in a large array of guard counters surrounding the main detector parts. These anti-coincidence counters, made of ~4 cm thick BGO crystals, have a large effective area for sub-MeV to MeV gamma-rays. They work as an excellent gamma-ray burst monitor with limited angular resolution (~5 degree). The on-board signal-processing system and the data transmitted to the ground are also described.