Normalized to: Kurinsky, N.
[1]
oai:arXiv.org:2005.14067 [pdf] - 2103535
Constraints on low-mass, relic dark matter candidates from a
surface-operated SuperCDMS single-charge sensitive detector
SuperCDMS Collaboration;
Amaral, D. W.;
Aralis, T.;
Aramaki, T.;
Arnquist, I. J.;
Azadbakht, E.;
Banik, S.;
Barker, D.;
Bathurst, C.;
Bauer, D. A.;
Bezerra, L. V. S.;
Bhattacharyya, R.;
Binder, T.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Calkins, R.;
Cameron, R. A.;
Cartaro, C.;
Cerdeño, D. G.;
Chang, Y. -Y.;
Chen, R.;
Chott, N.;
Cooley, J.;
Coombes, H.;
Corbett, J.;
Cushman, P.;
De Brienne, F.;
di Vacri, M. L.;
Diamond, M. D.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fink, C. W.;
Fouts, K.;
Fritts, M.;
Gerbier, G.;
Germond, R.;
Ghaith, M.;
Golwala, S. R.;
Harris, H. R.;
Herbert, N.;
Hines, B. A.;
Hollister, M. I.;
Hong, Z.;
Hoppe, E. W.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Kelsey, M. H.;
Kubik, A.;
Kurinsky, N. A.;
Lawrence, R. E.;
Li, A.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
MacFarlane, D. B.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Mayer, A. J.;
Michaud, É. M.;
Michielin, E.;
Mirabolfathi, N.;
Mohanty, B.;
Mendoza, J. D. Morales;
Nagorny, S.;
Nelson, J.;
Neog, H.;
Novati, V.;
Orrell, J. L.;
Oser, S. M.;
Page, W. A.;
Pakarha, P.;
Partridge, R.;
Podviianiuk, R.;
Ponce, F.;
Poudel, S.;
Pyle, M.;
Rau, W.;
Reid, E.;
Ren, R.;
Reynolds, T.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Sattari, A.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Sincavage, D. J.;
Stanford, C.;
Stein, M.;
Street, J.;
Toback, D.;
Underwood, R.;
Verma, S.;
Villano, A. N.;
von Krosigk, B.;
Watkins, S. L.;
Wills, L.;
Wilson, J. S.;
Wilson, M. J.;
Winchell, J.;
Wright, D. H.;
Yellin, S.;
Young, B. A.;
Yu, T. C.;
Zhang, E.;
Zhang, H. G.;
Zhao, X.;
Zheng, L.
Submitted: 2020-05-28
This article presents an analysis and the resulting limits on light dark
matter inelastically scattering off of electrons, and on dark photon and
axion-like particle absorption, using a second-generation SuperCDMS
high-voltage eV-resolution detector. The 0.93 gram Si detector achieved a 3 eV
phonon energy resolution; for a detector bias of 100 V, this corresponds to a
charge resolution of 3% of a single electron-hole pair. The energy spectrum is
reported from a blind analysis with 1.2 gram-days of exposure acquired in an
above-ground laboratory. With charge carrier trapping and impact ionization
effects incorporated into the dark matter signal models, the dark
matter-electron cross section $\bar{\sigma}_{e}$ is constrained for dark matter
masses from 0.5--$10^{4} $MeV$/c^{2}$; in the mass range from 1.2--50
eV$/c^{2}$ the dark photon kinetic mixing parameter $\varepsilon$ and the
axioelectric coupling constant $g_{ae}$ are constrained. The minimum 90%
confidence-level upper limits within the above mentioned mass ranges are
$\bar{\sigma}_{e}\,=\,8.7\times10^{-34}$ cm$^{2}$,
$\varepsilon\,=\,3.3\times10^{-14}$, and $g_{ae}\,=\,1.0\times10^{-9}$.
[2]
oai:arXiv.org:2004.10709 [pdf] - 2083491
Ionization Yield in Silicon for eV-Scale Electron-Recoil Processes
Submitted: 2020-04-22, last modified: 2020-04-24
The development of single charge resolving, macroscopic silicon detectors has
opened a window into rare processes at the O(eV) scale. In order to reconstruct
the energy of a given event, or model the charge signal obtained for a given
amount of energy absorbed by the electrons in a detector, an accurate charge
yield model is needed. In this paper we review existing measurements of charge
yield in Silicon, focusing in particular on the region below 1 keV. We
highlight a calibration gap between 12-50 eV (referred to as the "UV-gap") and
employ a phenomenological model of impact ionization to explore the likely
charge yield in this energy regime. Finally, we explore the impact of
variations in this model on a test case, that of dark matter scattering off
electrons, to illustrate the scientific impact of uncertainties in charge
yield.
[3]
oai:arXiv.org:2002.06937 [pdf] - 2069065
A Dark Matter Interpretation of Excesses in Multiple Direct Detection
Experiments
Submitted: 2020-02-17, last modified: 2020-03-24
We present a novel unifying interpretation of excess event rates observed in
several dark matter direct-detection experiments that utilize single-electron
threshold semiconductor detectors. Despite their different locations,
exposures, readout techniques, detector composition, and operating depths,
these experiments all observe statistically significant excess event rates of
$\sim$ 10 Hz/kg. However, none of these persistent excesses has yet been
reported as a dark matter signal because individually, each can be attributed
to different well-motivated but unmodeled backgrounds, and taken together, they
cannot be explained by dark matter particles scattering elastically off
detector nuclei or electrons. We show that these results can be reconciled if
the semiconductor detectors are seeing a collective inelastic process,
consistent with exciting a plasmon. We further show that plasmon excitation
could arise in two compelling dark matter scenarios, both of which can explain
rates of existing signal excesses in germanium and, at least at the order of
magnitude level, across several single-electron threshold detectors. At least
one of these scenarios also yields the correct relic density from thermal
freeze-out. Both dark matter scenarios motivate a radical rethinking of the
standard interpretations of dark matter-electron scattering from recent
experiments.
[4]
oai:arXiv.org:2003.00101 [pdf] - 2057079
Reply to Robinson and Michaud, arXiv:2002.08893
Submitted: 2020-02-28
We respond to Robinson and Michaud's (RM) comment (arXiv:2002.08893) on our
recent preprint arXiv:2002.06937, in which we discuss recent excesses in
low-threshold dark matter searches, and offer a potential unifying dark matter
interpretation. We thank RM for their feedback, which highlights the critical
need for future measurements to directly calibrate plasmon charge yields for
low $\sim$ 10 eV energy depositions. RM objected to our assertion that plasmons
generated at energy scales below 100~eV may have a large branching fraction
into phonons. As we argue below, the points raised by RM do not invalidate our
primary conclusions, as they pertain to a much different energy scale than we
discuss in our paper.
[5]
oai:arXiv.org:1903.06517 [pdf] - 2060101
Single Electron-Hole Pair Sensitive Silicon Detector with Surface Event
Rejection
Hong, Ziqing;
Ren, Runze;
Kurinsky, Noah;
Figueroa-Feliciano, Enectali;
Wills, Lise;
Ganjam, Suhas;
Mahapatra, Rupak;
Mirabolfathi, Nader;
Nebolsky, Brian;
Pinckney, H. Douglas;
Platt, Mark
Submitted: 2019-03-15, last modified: 2020-02-27
We demonstrate single electron-hole pair resolution in a single-sided,
contact-free 1 cm$^2$ by 1 mm thick Si crystal operated at 48 mK, with a
baseline energy resolution of 3 eV. This crystal can be operated at voltages in
excess of $\pm50$ V, resulting in a measured charge resolution of 0.06
electron-hole pairs. The high aluminum coverage ($\sim$70%) of this device
allows for the discrimination of surface events and separation of events
occurring near the center of the detector from those near the edge. We use this
discrimination ability to show that non-quantized dark events seen in previous
detectors of a similar design are likely dominated by charge leakage along the
side wall of the device.
[6]
oai:arXiv.org:2001.01724 [pdf] - 2026608
Updated design of the CMB polarization experiment satellite LiteBIRD
Sugai, H.;
Ade, P. A. R.;
Akiba, Y.;
Alonso, D.;
Arnold, K.;
Aumont, J.;
Austermann, J.;
Baccigalupi, C.;
Banday, A. J.;
Banerji, R.;
Barreiro, R. B.;
Basak, S.;
Beall, J.;
Beckman, S.;
Bersanelli, M.;
Borrill, J.;
Boulanger, F.;
Brown, M. L.;
Bucher, M.;
Buzzelli, A.;
Calabrese, E.;
Casas, F. J.;
Challinor, A.;
Chan, V.;
Chinone, Y.;
Cliche, J. -F.;
Columbro, F.;
Cukierman, A.;
Curtis, D.;
Danto, P.;
de Bernardis, P.;
de Haan, T.;
De Petris, M.;
Dickinson, C.;
Dobbs, M.;
Dotani, T.;
Duband, L.;
Ducout, A.;
Duff, S.;
Duivenvoorden, A.;
Duval, J. -M.;
Ebisawa, K.;
Elleflot, T.;
Enokida, H.;
Eriksen, H. K.;
Errard, J.;
Essinger-Hileman, T.;
Finelli, F.;
Flauger, R.;
Franceschet, C.;
Fuskeland, U.;
Ganga, K.;
Gao, J. -R.;
Génova-Santos, R.;
Ghigna, T.;
Gomez, A.;
Gradziel, M. L.;
Grain, J.;
Grupp, F.;
Gruppuso, A.;
Gudmundsson, J. E.;
Halverson, N. W.;
Hargrave, P.;
Hasebe, T.;
Hasegawa, M.;
Hattori, M.;
Hazumi, M.;
Henrot-Versille, S.;
Herranz, D.;
Hill, C.;
Hilton, G.;
Hirota, Y.;
Hivon, E.;
Hlozek, R.;
Hoang, D. -T.;
Hubmayr, J.;
Ichiki, K.;
Iida, T.;
Imada, H.;
Ishimura, K.;
Ishino, H.;
Jaehnig, G. C.;
Jones, M.;
Kaga, T.;
Kashima, S.;
Kataoka, Y.;
Katayama, N.;
Kawasaki, T.;
Keskitalo, R.;
Kibayashi, A.;
Kikuchi, T.;
Kimura, K.;
Kisner, T.;
Kobayashi, Y.;
Kogiso, N.;
Kogut, A.;
Kohri, K.;
Komatsu, E.;
Komatsu, K.;
Konishi, K.;
Krachmalnicoff, N.;
Kuo, C. L.;
Kurinsky, N.;
Kushino, A.;
Kuwata-Gonokami, M.;
Lamagna, L.;
Lattanzi, M.;
Lee, A. T.;
Linder, E.;
Maffei, B.;
Maino, D.;
Maki, M.;
Mangilli, A.;
Martínez-González, E.;
Masi, S.;
Mathon, R.;
Matsumura, T.;
Mennella, A.;
Migliaccio, M.;
Minami, Y.;
Mistuda, K.;
Molinari, D.;
Montier, L.;
Morgante, G.;
Mot, B.;
Murata, Y.;
Murphy, J. A.;
Nagai, M.;
Nagata, R.;
Nakamura, S.;
Namikawa, T.;
Natoli, P.;
Nerva, S.;
Nishibori, T.;
Nishino, H.;
Nomura, Y.;
Noviello, F.;
O'Sullivan, C.;
Ochi, H.;
Ogawa, H.;
Ogawa, H.;
Ohsaki, H.;
Ohta, I.;
Okada, N.;
Okada, N.;
Pagano, L.;
Paiella, A.;
Paoletti, D.;
Patanchon, G.;
Piacentini, F.;
Pisano, G.;
Polenta, G.;
Poletti, D.;
Prouvé, T.;
Puglisi, G.;
Rambaud, D.;
Raum, C.;
Realini, S.;
Remazeilles, M.;
Roudil, G.;
Rubiño-Martín, J. A.;
Russell, M.;
Sakurai, H.;
Sakurai, Y.;
Sandri, M.;
Savini, G.;
Scott, D.;
Sekimoto, Y.;
Sherwin, B. D.;
Shinozaki, K.;
Shiraishi, M.;
Shirron, P.;
Signorelli, G.;
Smecher, G.;
Spizzi, P.;
Stever, S. L.;
Stompor, R.;
Sugiyama, S.;
Suzuki, A.;
Suzuki, J.;
Switzer, E.;
Takaku, R.;
Takakura, H.;
Takakura, S.;
Takeda, Y.;
Taylor, A.;
Taylor, E.;
Terao, Y.;
Thompson, K. L.;
Thorne, B.;
Tomasi, M.;
Tomida, H.;
Trappe, N.;
Tristram, M.;
Tsuji, M.;
Tsujimoto, M.;
Tucker, C.;
Ullom, J.;
Uozumi, S.;
Utsunomiya, S.;
Van Lanen, J.;
Vermeulen, G.;
Vielva, P.;
Villa, F.;
Vissers, M.;
Vittorio, N.;
Voisin, F.;
Walker, I.;
Watanabe, N.;
Wehus, I.;
Weller, J.;
Westbrook, B.;
Winter, B.;
Wollack, E.;
Yamamoto, R.;
Yamasaki, N. Y.;
Yanagisawa, M.;
Yoshida, T.;
Yumoto, J.;
Zannoni, M.;
Zonca, A.
Submitted: 2020-01-06
Recent developments of transition-edge sensors (TESs), based on extensive
experience in ground-based experiments, have been making the sensor techniques
mature enough for their application on future satellite CMB polarization
experiments. LiteBIRD is in the most advanced phase among such future
satellites, targeting its launch in Japanese Fiscal Year 2027 (2027FY) with
JAXA's H3 rocket. It will accommodate more than 4000 TESs in focal planes of
reflective low-frequency and refractive medium-and-high-frequency telescopes in
order to detect a signature imprinted on the cosmic microwave background (CMB)
by the primordial gravitational waves predicted in cosmic inflation. The total
wide frequency coverage between 34GHz and 448GHz enables us to extract such
weak spiral polarization patterns through the precise subtraction of our
Galaxy's foreground emission by using spectral differences among CMB and
foreground signals. Telescopes are cooled down to 5Kelvin for suppressing
thermal noise and contain polarization modulators with transmissive half-wave
plates at individual apertures for separating sky polarization signals from
artificial polarization and for mitigating from instrumental 1/f noise. Passive
cooling by using V-grooves supports active cooling with mechanical coolers as
well as adiabatic demagnetization refrigerators. Sky observations from the
second Sun-Earth Lagrangian point, L2, are planned for three years. An
international collaboration between Japan, USA, Canada, and Europe is sharing
various roles. In May 2019, the Institute of Space and Astronautical Science
(ISAS), JAXA selected LiteBIRD as the strategic large mission No. 2.
[7]
oai:arXiv.org:1806.07043 [pdf] - 1944785
Production Rate Measurement of Tritium and Other Cosmogenic Isotopes in
Germanium with CDMSlite
SuperCDMS Collaboration;
Agnese, R.;
Aralis, T.;
Aramaki, T.;
Arnquist, I. J.;
Azadbakht, E.;
Baker, W.;
Barker, D.;
Bauer, D. A.;
Binder, T.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Calkins, R.;
Cartaro, C.;
Cerdeño, D. G.;
Chang, Y. -Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
Doughty, T.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fink, C. W.;
Fritts, M.;
Gerbier, G.;
Germond, R.;
Ghaith, M.;
Golwal, S. R.;
Harris, H. R.;
Hong, Z.;
Hoppe, E. W.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Jena, C.;
Kelsey, M. H.;
Kennedy, A.;
Kubik, A.;
Kurinsky, N. A.;
Lawrence, R. E.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Miller, E.;
Mirabolfathi, N.;
Mohanty, B.;
Mendoza, J. D. Morales;
Nelson, J.;
Orrell, J. L.;
Oser, S. M.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Ponce, F.;
Poudel, S.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Reisetter, A.;
Ren, R.;
Reynolds, T.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Banik, S.;
Sander, J.;
Scarff, A.;
Schnee, R. W.;
Scorza, S.;
Senapati, K.;
Serfass, B.;
Speller, D.;
Stein, M.;
Street, J.;
Tanaka, H. A.;
Toback, D.;
Underwood, R.;
Villano, A. N.;
von Krosigk, B.;
Watkins, S. L.;
Wilson, J. S.;
Wilson, M. J.;
Winchell, J.;
Wright, D. H.;
Yellin, S.;
Young, B. A.;
Zhang, X.;
Zhao, X.
Submitted: 2018-06-19, last modified: 2019-08-16
Future direct searches for low-mass dark matter particles with germanium
detectors, such as SuperCDMS SNOLAB, are expected to be limited by backgrounds
from radioactive isotopes activated by cosmogenic radiation inside the
germanium. There are limited experimental data available to constrain
production rates and a large spread of theoretical predictions. We examine the
calculation of expected production rates, and analyze data from the second run
of the CDMS low ionization threshold experiment (CDMSlite) to estimate the
rates for several isotopes. We model the measured CDMSlite spectrum and fit for
contributions from tritium and other isotopes. Using the knowledge of the
detector history, these results are converted to cosmogenic production rates at
sea level. The production rates in atoms/(kg$\cdot$day) are 74$\pm$9 for $^3$H,
1.5$\pm$0.7 for $^{55}$Fe, 17$\pm$5 for $^{65}$Zn, and 30$\pm$18 for $^{68}$Ge.
[8]
oai:arXiv.org:1804.10697 [pdf] - 1877835
First Dark Matter Constraints from a SuperCDMS Single-Charge Sensitive
Detector
SuperCDMS Collaboration;
Agnese, R.;
Aralis, T.;
Aramaki, T.;
Arnquist, I. J.;
Azadbakht, E.;
Baker, W.;
Banik, S.;
Barker, D.;
Bauer, D. A.;
Binder, T.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Calkins, R.;
Cartaro, C.;
Cerdeno, D. G.;
Chang, Y. -Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
Di Stefano, P. C. F.;
Doughty, T.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fink, C.;
Fritts, M.;
Gerbier, G.;
Germond, R.;
Ghaith, M.;
Golwala, S. R.;
Harris, H. R.;
Hong, Z.;
Hoppe, E. W.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jena, C.;
Kelsey, M. H.;
Kennedy, A.;
Kubik, A.;
Kurinsky, N. A.;
Lawrence, R. E.;
Leyva, J. V.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Miller, E. H.;
Mirabolfathi, N.;
Mohanty, B.;
Mendoza, J. D. Morales;
Nelson, J.;
Orrell, J. L.;
Oser, S. M.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Ponce, F.;
Poudel, S.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Reisetter, A.;
Reynolds, T.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Romani, R. K.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Scarff, A.;
Schnee, R. W.;
Scorza, S.;
Senapati, K.;
Serfass, B.;
So, J.;
Speller, D.;
Stanford, C.;
Stein, M.;
Street, J.;
Tanaka, H. A.;
Toback, D.;
Underwood, R.;
Villano, A. N.;
von Krosigk, B.;
Watkins, S. L.;
Wilson, J. S.;
Wilson, M. J.;
Winchell, J.;
Wright, D. H.;
Yellin, S.;
Young, B. A.;
Zhang, X.;
Zhao, X.
Submitted: 2018-04-27, last modified: 2019-05-03
We present the first limits on inelastic electron-scattering dark matter and
dark photon absorption using a prototype SuperCDMS detector having a charge
resolution of 0.1 electron-hole pairs (CDMS HVeV, a 0.93 gram CDMS HV device).
These electron-recoil limits significantly improve experimental constraints on
dark matter particles with masses as low as 1 MeV/$\mathrm{c^2}$. We
demonstrate a sensitivity to dark photons competitive with other leading
approaches but using substantially less exposure (0.49 gram days). These
results demonstrate the scientific potential of phonon-mediated semiconductor
detectors that are sensitive to single electronic excitations.
[9]
oai:arXiv.org:1808.09098 [pdf] - 1873743
Search for Low-Mass Dark Matter with CDMSlite Using a Profile Likelihood
Fit
SuperCDMS Collaboration;
Agnese, R.;
Aralis, T.;
Aramaki, T.;
Arnquist, I. J.;
Azadbakht, E.;
Baker, W.;
Banik, S.;
Barker, D.;
Bauer, D. A.;
Binder, T.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Calkins, R.;
Cameron, R. A.;
Cartaro, C.;
Cerdeño, D. G.;
Chang, Y. -Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
De Brienne, F.;
Doughty, T.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fink, C. W.;
Fritts, M.;
Gerbier, G.;
Germond, R.;
Ghaith, M.;
Golwala, S. R.;
Harris, H. R.;
Herbert, N.;
Hong, Z.;
Hoppe, E. W.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Jena, C.;
Kelsey, M. H.;
Kennedy, A.;
Kubik, A.;
Kurinsky, N. A.;
Lawrence, R. E.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Miller, E.;
Mirabolfathi, N.;
Mohanty, B.;
Mendoza, J. D. Morales;
Nelson, J.;
Neog, H.;
Orrell, J. L.;
Oser, S. M.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Ponce, F.;
Poudel, S.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Reisetter, A.;
Ren, R.;
Reynolds, T.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Scarff, A.;
Schnee, R. W.;
Scorza, S.;
Senapati, K.;
Serfass, B.;
Speller, D.;
Stanford, C.;
Stein, M.;
Street, J.;
Tanaka, H. A.;
Toback, D.;
Underwood, R.;
Villano, A. N.;
von Krosigk, B.;
Watkins, S. L.;
Wilson, J. S.;
Wilson, M. J.;
Winchell, J.;
Wright, D. H.;
Yellin, S.;
Young, B. A.;
Zhang, X.;
Zhao, X.
Submitted: 2018-08-27, last modified: 2019-04-25
The Cryogenic Dark Matter Search low ionization threshold experiment
(CDMSlite) searches for interactions between dark matter particles and
germanium nuclei in cryogenic detectors. The experiment has achieved a low
energy threshold with improved sensitivity to low-mass (<10 GeV/c$^2$) dark
matter particles. We present an analysis of the final CDMSlite data set, taken
with a different detector than was used for the two previous CDMSlite data
sets. This analysis includes a data "salting" method to protect against bias,
improved noise discrimination, background modeling, and the use of profile
likelihood methods to search for a dark matter signal in the presence of
backgrounds. We achieve an energy threshold of 70 eV and significantly improve
the sensitivity for dark matter particles with masses between 2.5 and 10
GeV/c$^2$ compared to previous analyses. We set an upper limit on the dark
matter-nucleon scattering cross section in germanium of 5.4$\times$10$^{-42}$
cm$^2$ at 5 GeV/c$^2$, a factor of $\sim$2.5 improvement over the previous
CDMSlite result.
[10]
oai:arXiv.org:1805.09942 [pdf] - 1867949
Energy Loss Due to Defect Formation from $^{206}$Pb Recoils in SuperCDMS
Germanium Detectors
Agnese, Robert;
Aralis, Taylor;
Aramaki, Tsuguo;
Arnquist, Isaac;
Azadbakht, Elham;
Baker, William;
Banik, Samir;
Barker, D'Ann;
Bauer, Dan;
Binder, Thomas;
Bowles, Michael;
Brink, Paul;
Bunker, Ray;
Cabrera, Blas;
Calkins, Robert;
Cartaro, Concetta;
Cerdeno, David;
Chang, Yen-Yung;
Cooley, Jodi;
Cornell, Brett;
Cushman, Priscilla;
Di Stefano, Philippe;
Doughty, Todd;
Fascione, Eleanor;
Figueroa, Tali;
Fink, Caleb;
Fritts, Matt;
Gerbier, Gilles;
Germond, Richard;
Ghaith, Muad;
Golwala, Sunil;
Harris, Rusty;
Hong, Ziqing;
Hoppe, Eric;
Hsu, Lauren;
Huber, Martin;
Iyer, Vijay;
Jardin, Dan;
Jena, Chitrasen;
Kelsey, Michael;
Kennedy, Allison;
Kubik, Andrew;
Kurinsky, Noah;
Lawrence, Richard;
Loer, Ben;
Lopez-Asamar, Elias;
Lukens, Pat;
MacDonell, Danika;
Mahapatra, Rupak;
Mandic, Vuk;
Mast, Nicholas;
Miller, Eric;
Mirabolfathi, Nader;
Mohanty, Bedangadas;
Morales, Jorge;
Nelson, Jack;
Orrell, John;
Oser, Scott;
Page, William;
Partridge, Richard;
Pepin, Mark;
Ponce, Francisco;
Poudel, Sudip;
Pyle, Matt;
Qiu, Hang;
Rau, Wolfgang;
Reisetter, Angela;
Ren, Tom;
Reynolds, Tyler;
Roberts, Amy;
Robinson, Alan;
Rogers, Hannah;
Saab, Tarek;
Sadoulet, Bernard;
Sander, Joel;
Scarff, Andrew;
Schnee, Richard;
Scorza, Silvia;
Senapati, Kartik;
Serfass, Bruno;
Speller, Danielle;
Stein, Matthew;
Street, Joseph;
Tanaka, Hirohisa;
Toback, David;
Underwood, Ryan;
Villano, Anthony;
von Krosigk, Belina;
Watkins, Samuel;
Wilson, Jon;
Wilson, Matthew;
Winchell, Joshua;
Wright, Dennis;
Yellin, Steve;
Young, Betty;
Zhang, Xiaohe;
Zhao, Xuji
Submitted: 2018-05-24, last modified: 2019-04-16
The Super Cryogenic Dark Matter Search experiment (SuperCDMS) at the Soudan
Underground Laboratory studied energy loss associated with Frenkel defect
formation in germanium crystals at mK temperatures using in situ $^{210}$Pb
sources. We examine the spectrum of $^{206}$Pb nuclear recoils near its
expected 103 keV endpoint energy and determine an energy loss of
$\left(6.08\pm0.18\right)$ %, which we attribute to defect formation. From this
result and using TRIM simulations, we extract the first experimentally
determined average displacement threshold energy of
$\left(19.7^{+0.6}_{-0.5}\right)$ eV for germanium. This has implications for
the analysis thresholds of future germanium-based dark matter searches.
[11]
oai:arXiv.org:1803.02903 [pdf] - 1724039
Nuclear-recoil energy scale in CDMS II silicon dark-matter detectors
Agnese, R.;
Anderson, A. J.;
Aramaki, T.;
Baker, W.;
Balakishiyeva, D.;
Banik, S.;
Barker, D.;
Thakur, R. Basu;
Bauer, D. A.;
Binder, T.;
Borgland, A.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Calkins, R.;
Cartaro, C.;
Cerdeno, D. G.;
Chagani, H.;
Chang, Y. -Y.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
Daal, M.;
Doughty, T.;
Dragowsky, E. M.;
Esteban, L.;
Fallows, S.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fritts, M.;
Gerbier, G.;
Germond, R.;
Ghaith, M.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Holmgren, D.;
Hong, Z.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Jena, C.;
Kelsey, M. H.;
Kennedy, A.;
Kubik, A.;
Kurinsky, N. A.;
Leder, A.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
McCarthy, K. A.;
Miller, E. H.;
Mirabolfathi, N.;
Moffatt, R. A.;
Mohanty, B.;
Moore, D.;
Mendoza, J. D. Morales;
Nelson, J.;
Oser, S. M.;
Page, K.;
Page, W. A.;
Partridge, R.;
Martinez, M. Penalver;
Pepin, M.;
Phipps, A.;
Poudel, S.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Roberts, A.;
Rogers, H. E.;
Robinson, A. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Senapati, K.;
Serfass, B.;
Speller, D.;
Di Stefano, P. C. F.;
Stein, M.;
Street, J.;
Tanaka, H. A.;
Toback, D.;
Underwood, R.;
Villano, A. N.;
von Krosigk, B.;
Welliver, B.;
Wilson, J. S.;
Wilson, M. J.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, X.;
Zhao, X.
Submitted: 2018-03-07, last modified: 2018-07-27
The Cryogenic Dark Matter Search (CDMS II) experiment aims to detect dark
matter particles that elastically scatter from nuclei in semiconductor
detectors. The resulting nuclear-recoil energy depositions are detected by
ionization and phonon sensors. Neutrons produce a similar spectrum of
low-energy nuclear recoils in such detectors, while most other backgrounds
produce electron recoils. The absolute energy scale for nuclear recoils is
necessary to interpret results correctly. The energy scale can be determined in
CDMS II silicon detectors using neutrons incident from a broad-spectrum
$^{252}$Cf source, taking advantage of a prominent resonance in the neutron
elastic scattering cross section of silicon at a recoil (neutron) energy near
20 (182) keV. Results indicate that the phonon collection efficiency for
nuclear recoils is $4.8^{+0.7}_{-0.9}$% lower than for electron recoils of the
same energy. Comparisons of the ionization signals for nuclear recoils to those
measured previously by other groups at higher electric fields indicate that the
ionization collection efficiency for CDMS II silicon detectors operated at
$\sim$4 V/cm is consistent with 100% for nuclear recoils below 20 keV and
gradually decreases for larger energies to $\sim$75% at 100 keV. The impact of
these measurements on previously published CDMS II silicon results is small.
[12]
oai:arXiv.org:1801.06987 [pdf] - 1698011
The LiteBIRD Satellite Mission - Sub-Kelvin Instrument
Suzuki, A.;
Ade, P. A. R.;
Akiba, Y.;
Alonso, D.;
Arnold, K.;
Aumont, J.;
Baccigalupi, C.;
Barron, D.;
Basak, S.;
Beckman, S.;
Borrill, J.;
Boulanger, F.;
Bucher, M.;
Calabrese, E.;
Chinone, Y.;
Cho, H-M.;
Cukierman, A.;
Curtis, D. W.;
de Haan, T.;
Dobbs, M.;
Dominjon, A.;
Dotani, T.;
Duband, L.;
Ducout, A.;
Dunkley, J.;
Duval, J. M.;
Elleflot, T.;
Eriksen, H. K.;
Errard, J.;
Fischer, J.;
Fujino, T.;
Funaki, T.;
Fuskeland, U.;
Ganga, K.;
Goeckner-Wald, N.;
Grain, J.;
Halverson, N. W.;
Hamada, T.;
Hasebe, T.;
Hasegawa, M.;
Hattori, K.;
Hattori, M.;
Hayes, L.;
Hazumi, M.;
Hidehira, N.;
Hill, C. A.;
Hilton, G.;
Hubmayr, J.;
Ichiki, K.;
Iida, T.;
Imada, H.;
Inoue, M.;
Inoue, Y.;
D., K.;
Ishino, H.;
Jeong, O.;
Kanai, H.;
Kaneko, D.;
Kashima, S.;
Katayama, N.;
Kawasaki, T.;
Kernasovskiy, S. A.;
Keskitalo, R.;
Kibayashi, A.;
Kida, Y.;
Kimura, K.;
Kisner, T.;
Kohri, K.;
Komatsu, E.;
Komatsu, K.;
Kuo, C. L.;
Kurinsky, N. A.;
Kusaka, A.;
Lazarian, A.;
Lee, A. T.;
Li, D.;
Linder, E.;
Maffei, B.;
Mangilli, A.;
Maki, M.;
Matsumura, T.;
Matsuura, S.;
Meilhan, D.;
Mima, S.;
Minami, Y.;
Mitsuda, K.;
Montier, L.;
Nagai, M.;
Nagasaki, T.;
Nagata, R.;
Nakajima, M.;
Nakamura, S.;
Namikawa, T.;
Naruse, M.;
Nishino, H.;
Nitta, T.;
Noguchi, T.;
Ogawa, H.;
Oguri, S.;
Okada, N.;
Okamoto, A.;
Okamura, T.;
Otani, C.;
Patanchon, G.;
Pisano, G.;
Rebeiz, G.;
Remazeilles, M.;
Richards, P. L.;
Sakai, S.;
Sakurai, Y.;
Sato, Y.;
Sato, N.;
Sawada, M.;
Segawa, Y.;
Sekimoto, Y.;
Seljak, U.;
Sherwin, B. D.;
Shimizu, T.;
Shinozaki, K.;
Stompor, R.;
Sugai, H.;
Sugita, H.;
Suzuki, J.;
Tajima, O.;
Takada, S.;
Takaku, R.;
Takakura, S.;
Takatori, S.;
Tanabe, D.;
Taylor, E.;
Thompson, K. L.;
Thorne, B.;
Tomaru, T.;
Tomida, T.;
Tomita, N.;
Tristram, M.;
Tucker, C.;
Turin, P.;
Tsujimoto, M.;
Uozumi, S.;
Utsunomiya, S.;
Uzawa, Y.;
Vansyngel, F.;
Wehus, I. K.;
Westbrook, B.;
Willer, M.;
Whitehorn, N.;
Yamada, Y.;
Yamamoto, R.;
Yamasaki, N.;
Yamashita, T.;
Yoshida, M.
Submitted: 2018-01-22, last modified: 2018-03-15
Inflation is the leading theory of the first instant of the universe.
Inflation, which postulates that the universe underwent a period of rapid
expansion an instant after its birth, provides convincing explanation for
cosmological observations. Recent advancements in detector technology have
opened opportunities to explore primordial gravitational waves generated by the
inflation through B-mode (divergent-free) polarization pattern embedded in the
Cosmic Microwave Background anisotropies. If detected, these signals would
provide strong evidence for inflation, point to the correct model for
inflation, and open a window to physics at ultra-high energies.
LiteBIRD is a satellite mission with a goal of detecting
degree-and-larger-angular-scale B-mode polarization. LiteBIRD will observe at
the second Lagrange point with a 400 mm diameter telescope and 2,622 detectors.
It will survey the entire sky with 15 frequency bands from 40 to 400 GHz to
measure and subtract foregrounds.
The U.S. LiteBIRD team is proposing to deliver sub-Kelvin instruments that
include detectors and readout electronics. A lenslet-coupled sinuous antenna
array will cover low-frequency bands (40 GHz to 235 GHz) with four frequency
arrangements of trichroic pixels. An orthomode-transducer-coupled corrugated
horn array will cover high-frequency bands (280 GHz to 402 GHz) with three
types of single frequency detectors. The detectors will be made with Transition
Edge Sensor (TES) bolometers cooled to a 100 milli-Kelvin base temperature by
an adiabatic demagnetization refrigerator.The TES bolometers will be read out
using digital frequency multiplexing with Superconducting QUantum Interference
Device (SQUID) amplifiers. Up to 78 bolometers will be multiplexed with a
single SQUID amplidier.
We report on the sub-Kelvin instrument design and ongoing developments for
the LiteBIRD mission.
[13]
oai:arXiv.org:1707.01632 [pdf] - 1622232
Low-Mass Dark Matter Search with CDMSlite
SuperCDMS Collaboration;
Agnese, R.;
Anderson, A. J.;
Aralis, T.;
Aramaki, T.;
Arnquist, I. J.;
Baker, W.;
Balakishiyeva, D.;
Barker, D.;
Thakur, R. Basu;
Bauer, D. A.;
Binder, T.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Calkins, R.;
Cartaro, C.;
Cerdeno, D. G.;
Chang, Y.;
Chagani, H.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fritts, M.;
Gerbier, G.;
Ghaith, M.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hong, Z.;
Hoppe, E. W.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Jena, C.;
Kelsey, M. H.;
Kennedy, A.;
Kubik, A.;
Kurinsky, N. A.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Miller, E. H.;
Mirabolfathi, N.;
Moffatt, R. A.;
Mohanty, B.;
Mendoza, J. D. Morales;
Nelson, J.;
Orrell, J. L.;
Oser, S. M.;
Page, K.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Martinez, M. Penalver;
Phipps, A.;
Poudel, S.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Reynolds, T.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Senapati, K.;
Serfass, B.;
Speller, D.;
Stein, M.;
Street, J.;
Tanaka, H. A.;
Toback, D.;
Underwood, R.;
Villano, A. N.;
von Krosigk, B.;
Welliver, B.;
Wilson, J. S.;
Wilson, M. J;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, X.;
Zhao, X.
Submitted: 2017-07-06, last modified: 2018-01-18
The SuperCDMS experiment is designed to directly detect weakly interacting
massive particles (WIMPs) that may constitute the dark matter in our Galaxy.
During its operation at the Soudan Underground Laboratory, germanium detectors
were run in the CDMSlite mode to gather data sets with sensitivity specifically
for WIMPs with masses ${<}$10 GeV/$c^2$. In this mode, a higher detector-bias
voltage is applied to amplify the phonon signals produced by drifting charges.
This paper presents studies of the experimental noise and its effect on the
achievable energy threshold, which is demonstrated to be as low as 56
eV$_{\text{ee}}$ (electron equivalent energy). The detector-biasing
configuration is described in detail, with analysis corrections for voltage
variations to the level of a few percent. Detailed studies of the
electric-field geometry, and the resulting successful development of a fiducial
parameter, eliminate poorly measured events, yielding an energy resolution
ranging from ${\sim}$9 eV$_{\text{ee}}$ at 0 keV to 101 eV$_{\text{ee}}$ at
${\sim}$10 eV$_{\text{ee}}$. New results are derived for astrophysical
uncertainties relevant to the WIMP-search limits, specifically examining how
they are affected by variations in the most probable WIMP velocity and the
Galactic escape velocity. These variations become more important for WIMP
masses below 10 GeV/$c^2$. Finally, new limits on spin-dependent low-mass
WIMP-nucleon interactions are derived, with new parameter space excluded for
WIMP masses $\lesssim$3 GeV/$c^2$
[14]
oai:arXiv.org:1701.07239 [pdf] - 1534996
Exploring the evolution of star formation and dwarf galaxy properties
with JWST/MIRI serendipitous spectroscopic surveys
Bonato, Matteo;
Sajina, Anna;
De Zotti, Gianfranco;
McKinney, Jed;
Baronchelli, Ivano;
Negrello, Mattia;
Marchesini, Danilo;
Roebuck, Eric;
Shipley, Heath;
Kurinsky, Noah;
Pope, Alexandra;
Noriega-Crespo, Alberto;
Yan, Lin;
Kirkpatrick, Allison
Submitted: 2017-01-25
The James Webb Space Telescope's Medium Resolution Spectrometer (MRS), will
offer nearly 2 orders of magnitude improvement in sensitivity and >3X
improvement in spectral resolution over our previous space-based mid-IR
spectrometer, the Spitzer IRS. In this paper, we make predictions for
spectroscopic pointed observations and serendipitous detections with the MRS.
Specifically, pointed observations of Herschel sources require only a few
minutes on source integration for detections of several star-forming and active
galactic nucleus lines, out to z$=$3 and beyond. But the same data will also
include tens of serendipitous 0$\lesssim$z$\lesssim$4 galaxies per field with
infrared luminosities ranging $\sim10^6-10^{13}$L$_{\odot}$. In particular, for
the first time and for free we will be able to explore the
$L_{IR}<10^{9}L_{\odot}$ regime out to $z\sim3$. We estimate that with
$\sim$100 such fields, statistics of these detections will be sufficient to
constrain the evolution of the low-$L$ end of the infrared luminosity function,
and hence the star formation rate function. The above conclusions hold for a
wide range in potential low-$L$ end of the IR luminosity function, and
accounting for the PAH deficit in low-$L$, low-metallicity galaxies.
[15]
oai:arXiv.org:1611.04083 [pdf] - 1513810
SuperCDMS SNOLAB Low-Mass Detectors: Ultra-Sensitive Phonon Calorimeters
for a Sub-GeV Dark Matter Search
Submitted: 2016-11-12
We present the technical design for the SuperCDMS high-voltage, low-mass dark
matter detectors, designed to be sensitive to dark matter down to 300 MeV/$c^2$
in mass and resolve individual electron-hole pairs from low-energy scattering
events in high-purity Ge and Si crystals. In this paper we discuss some of the
studies and technological improvements which have allowed us to design such a
sensitive detector, including advances in phonon sensor design and detector
simulation. With this design we expect to achieve better than 10 eV (5 eV)
phonon energy resolution in our Ge (Si) detectors, and recoil energy resolution
below 1eV by exploiting Luke-Neganov phonon generation of charges accelerated
in high fields.
[16]
oai:arXiv.org:1610.00006 [pdf] - 1561019
Projected Sensitivity of the SuperCDMS SNOLAB experiment
Agnese, R.;
Anderson, A. J.;
Aramaki, T.;
Arnquist, I.;
Baker, W.;
Barker, D.;
Thakur, R. Basu;
Bauer, D. A.;
Borgland, A.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Calkins, R.;
Cartaro, C.;
Cerdeño, D. G.;
Chagani, H.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Fritts, M.;
Gerbier, G.;
Ghaith, M.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hofer, T.;
Holmgren, D.;
Hong, Z.;
Hoppe, E.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Kelsey, M. H.;
Kennedy, A.;
Kubik, A.;
Kurinsky, N. A.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Mirabolfathi, N.;
Moffatt, R. A.;
Mendoza, J. D. Morales;
Orrell, J. L.;
Oser, S. M.;
Page, K.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Poudel, S.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Serfass, B.;
Speller, D.;
Stein, M.;
Street, J.;
Tanaka, H. A.;
Toback, D.;
Underwood, R.;
Villano, A. N.;
von Krosigk, B.;
Welliver, B.;
Wilson, J. S.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, X.;
Zhao, X.
Submitted: 2016-09-30
SuperCDMS SNOLAB will be a next-generation experiment aimed at directly
detecting low-mass (< 10 GeV/c$^2$) particles that may constitute dark matter
by using cryogenic detectors of two types (HV and iZIP) and two target
materials (germanium and silicon). The experiment is being designed with an
initial sensitivity to nuclear recoil cross sections ~ 1 x 10$^{-43}$ cm$^2$
for a dark matter particle mass of 1 GeV/c$^2$, and with capacity to continue
exploration to both smaller masses and better sensitivities. The phonon
sensitivity of the HV detectors will be sufficient to detect nuclear recoils
from sub-GeV dark matter. A detailed calibration of the detector response to
low energy recoils will be needed to optimize running conditions of the HV
detectors and to interpret their data for dark matter searches. Low-activity
shielding, and the depth of SNOLAB, will reduce most backgrounds, but
cosmogenically produced $^{3}$H and naturally occurring $^{32}$Si will be
present in the detectors at some level. Even if these backgrounds are x10
higher than expected, the science reach of the HV detectors would be over three
orders of magnitude beyond current results for a dark matter mass of 1
GeV/c$^2$. The iZIP detectors are relatively insensitive to variations in
detector response and backgrounds, and will provide better sensitivity for dark
matter particle masses (> 5 GeV/c$^2$). The mix of detector types (HV and
iZIP), and targets (germanium and silicon), planned for the experiment, as well
as flexibility in how the detectors are operated, will allow us to maximize the
low-mass reach, and understand the backgrounds that the experiment will
encounter. Upgrades to the experiment, perhaps with a variety of
ultra-low-background cryogenic detectors, will extend dark matter sensitivity
down to the "neutrino floor", where coherent scatters of solar neutrinos become
a limiting background.
[18]
oai:arXiv.org:1605.02736 [pdf] - 1411580
The evolution in the stellar mass of Brightest Cluster Galaxies over the
past 10 billion years
Bellstedt, Sabine;
Lidman, Chris;
Muzzin, Adam;
Franx, Marijn;
Guatelli, Susanna;
Hill, Allison R.;
Hoekstra, Henk;
Kurinsky, Noah;
Labbe, Ivo;
Marchesini, Danilo;
Marsan, Z. Cemile;
Safavi-Naeini, Mitra;
Sifon, Cristobal;
Stefanon, Mauro;
van de Sande, Jesse;
van Dokkum, Pieter;
Weigel, Catherine
Submitted: 2016-05-09, last modified: 2016-05-16
Using a sample of 98 galaxy clusters recently imaged in the near infra-red
with the ESO NTT, WIYN and WHT telescopes, supplemented with 33 clusters from
the ESO archive, we measure how the stellar mass of the most massive galaxies
in the universe, namely Brightest Cluster Galaxies (BCG), increases with time.
Most of the BCGs in this new sample lie in the redshift range $0.2<z<0.6$,
which has been noted in recent works to mark an epoch over which the growth in
the stellar mass of BCGs stalls. From this sample of 132 clusters, we create a
subsample of 102 systems that includes only those clusters that have estimates
of the cluster mass. We combine the BCGs in this subsample with BCGs from the
literature, and find that the growth in stellar mass of BCGs from 10 billion
years ago to the present epoch is broadly consistent with recent semi-analytic
and semi-empirical models. As in other recent studies, tentative evidence
indicates that the stellar mass growth rate of BCGs may be slowing in the past
3.5 billion years. Further work in collecting larger samples, and in better
comparing observations with theory using mock images is required if a more
detailed comparison between the models and the data is to be made.
[19]
oai:arXiv.org:1407.0903 [pdf] - 1521934
Robust Constraint of Luminosity Function Evolution Through MCMC Sampling
Submitted: 2014-07-03, last modified: 2014-09-30
We present a new galaxy survey simulation package, which combines the power
of Markov Chain Monte Carlo (MCMC) sampling with a robust and adaptable model
of galaxy evolution. The aim of this code is to aid in the characterization and
study of new and existing galaxy surveys. In this paper we briefly describe the
MCMC implementation and the survey simulation methodology and associated tools.
A test case of this full suite was to constrain the evolution of the IR
Luminosity Function (LF) based on the HerMES (Herschel SPIRE) survey of the
Spitzer First Look Survey field. The initial results are consistent with
previous studies, but our more general approach should be of wider benefit to
the community.
[20]
oai:arXiv.org:1207.4706 [pdf] - 1124960
Planck intermediate results. VII. Statistical properties of infrared and
radio extragalactic sources from the Planck Early Release Compact Source
Catalogue at frequencies between 100 and 857 GHz
Planck Collaboration;
Ade, P. A. R.;
Aghanim, N.;
Argüeso, F.;
Arnaud, M.;
Ashdown, M.;
Atrio-Barandela, F.;
Aumont, J.;
Baccigalupi, C.;
Balbi, A.;
Banday, A. J.;
Barreiro, R. B.;
Battaner, E.;
Benabed, K.;
Benoît, A.;
Bernard, J. -P.;
Bersanelli, M.;
Bethermin, M.;
Bhatia, R.;
Bonaldi, A.;
Bond, J. R.;
Borrill, J.;
Bouchet, F. R.;
Burigana, C.;
Cabella, P.;
Cardoso, J. -F.;
Catalano, A.;
Cayón, L.;
Chamballu, A.;
Chary, R. -R.;
Chen, X.;
Chiang, L. -Y;
Christensen, P. R.;
Clements, D. L.;
Colafrancesco, S.;
Colombi, S.;
Colombo, L. P. L.;
Coulais, A.;
Crill, B. P.;
Cuttaia, F.;
Danese, L.;
Davis, R. J.;
de Bernardis, P.;
de Gasperis, G.;
de Zotti, G.;
Delabrouille, J.;
Dickinson, C.;
Diego, J. M.;
Dole, H.;
Donzelli, S.;
Doré, O.;
Dörl, U.;
Douspis, M.;
Dupac, X.;
Efstathiou, G.;
Enßlin, T. A.;
Eriksen, H. K.;
Finelli, F.;
Forni, O.;
Fosalba, P.;
Frailis, M.;
Franceschi, E.;
Galeotta, S.;
Ganga, K.;
Giard, M.;
Giardino, G.;
Giraud-Héraud, Y.;
González-Nuevo, J.;
Górski, K. M.;
Gregorio, A.;
Gruppuso, A.;
Hansen, F. K.;
Harrison, D.;
Henrot-Versillé, S.;
Hernández-Monteagudo, C.;
Herranz, D.;
Hildebrandt, S. R.;
Hivon, E.;
Hobson, M.;
Holmes, W. A.;
Jaffe, T. R.;
Jaffe, A. H.;
Jagemann, T.;
Jones, W. C.;
Juvela, M.;
Keihänen, E.;
Kisner, T. S.;
Kneissl, R.;
Knoche, J.;
Knox, L.;
Kunz, M.;
Kurinsky, N.;
Kurki-Suonio, H.;
Lagache, G.;
Lähteenmäki, A.;
Lamarre, J. -M.;
Lasenby, A.;
Lawrence, C. R.;
Leonardi, R.;
Lilje, P. B.;
López-Caniego, M.;
Macías-Pérez, J. F.;
Maino, D.;
Mandolesi, N.;
Maris, M.;
Marshall, D. J.;
Martínez-González, E.;
Masi, S.;
Massardi, M.;
Matarrese, S.;
Mazzotta, P.;
Melchiorri, A.;
Mendes, L.;
Mennella, A.;
Mitra, S.;
Miville-Deschênes, M. -A.;
Moneti, A.;
Montier, L.;
Morgante, G.;
Mortlock, D.;
Munshi, D.;
Murphy, J. A.;
Naselsky, P.;
Nati, F.;
Natoli, P.;
Nørgaard-Nielsen, H. U.;
Noviello, F.;
Novikov, D.;
Novikov, I.;
Osborne, S.;
Pajot, F.;
Paladini, R.;
Paoletti, D.;
Partridge, B.;
Pasian, F.;
Patanchon, G.;
Perdereau, O.;
Perotto, L.;
Perrotta, F.;
Piacentini, F.;
Piat, M.;
Pierpaoli, E.;
Plaszczynski, S.;
Pointecouteau, E.;
Polenta, G.;
Ponthieu, N.;
Popa, L.;
Poutanen, T.;
Pratt, G. W.;
Prunet, S.;
Puget, J. -L.;
Rachen, J. P.;
Reach, W. T.;
Rebolo, R.;
Reinecke, M.;
Renault, C.;
Ricciardi, S.;
Riller, T.;
Ristorcelli, I.;
Rocha, G.;
Rosset, C.;
Rowan-Robinson, M.;
Rubiño-Martín, J. A.;
Rusholme, B.;
Sajina, A.;
Sandri, M.;
Savini, G.;
Scott, D.;
Smoot, G. F.;
Starck, J. -L.;
Sudiwala, R.;
Suur-Uski, A. -S.;
Sygnet, J. -F.;
Tauber, J. A.;
Terenzi, L.;
Toffolatti, L.;
Tomasi, M.;
Tristram, M.;
Tucci, M.;
Türler, M.;
Valenziano, L.;
Van Tent, B.;
Vielva, P.;
Villa, F.;
Vittorio, N.;
Wade, L. A.;
Wandelt, B. D.;
White, M.;
Yvon, D.;
Zacchei, A.;
Zonca, A.
Submitted: 2012-07-19, last modified: 2013-01-22
(abridged for arXiv) We make use of the Planck all-sky survey to derive
number counts and spectral indices of extragalactic sources -- infrared and
radio sources -- from the Planck Early Catalogue (ERCSC) at 100 to 857GHz. Our
sample contains, after the 80% completeness cut, between 122 and 452 and
sources, with flux densities above 0.3 and 1.9Jy at 100 and 857GHz, over about
31 to 40% of the sky. Using Planck HFI, all the sources have been classified as
either dust-dominated or synchrotron-dominated on the basis of their spectral
energy distributions (SED). Our sample is thus complete, flux-limited and
color-selected to differentiate between the two populations. We find an
approximately equal number of synchrotron and dusty sources between 217 and
353GHz; at 353GHz or higher (or 217GHz and lower) frequencies, the number is
dominated by dusty (synchrotron) sources, as expected. For most of the sources,
the spectral indices are also derived. We provide for the first time counts of
bright sources from 353 to 857GHz and the contributions from dusty and
synchrotron sources at all HFI frequencies in the key spectral range where
these spectra are crossing. The observed counts are in the Euclidean regime.
The number counts are compared to previously published data (earlier Planck,
Herschel, BLAST, SCUBA, LABOCA, SPT, and ACT) and models taking into account
both radio or infrared galaxies. We derive the multi-frequency Euclidean level
and compare it to WMAP, Spitzer and IRAS results. The submillimetre number
counts are not well reproduced by current evolution models of dusty galaxies,
whereas the millimetre part appears reasonably well fitted by the most recent
model for synchrotron-dominated sources. Finally we provide estimates of the
local luminosity density of dusty galaxies, providing the first such
measurements at 545 and 857GHz.
[21]
oai:arXiv.org:1211.3931 [pdf] - 616305
VLA/JVLA Monitoring of Bright Northern Radio Sources
Submitted: 2012-11-16
We report multiple epoch VLA/JVLA observations of 89 northern hemisphere
sources, most with 37\,GHz flux density > 1 Jy, observed at 4.8, 8.5, 33.5, and
43.3 GHz. The high frequency selection leads to a predominantly flat spectrum
sample, with 85% of our sources being in the Planck Early Release Compact
Source Catalog (ERCSC). These observations allow us to: 1) validate Planck's 30
and 44 GHz flux density scale, 2) extend the radio SEDs of Planck sources to
lower frequencies allowing for the full 5-857GHz regime to be studied, and 3)
characterize the variability of these sources. At 30 GHz and 44 GHz, the JVLA
and Planck flux densities agree to within 3%. On timescales of less than two
months the median variability of our sources is 2%. On timescales of about a
year the median variability increases to 14%. Using the WMAP 7-year data, the
30 GHz median variability on a 1-6 years timescale is 16%.