Normalized to: Kurhade, V.
[1]
oai:arXiv.org:1702.08624 [pdf] - 1581666
Calibration of the Large Area X-ray Proportional Counter (LAXPC)
instrument on-board AstroSat
Antia, H. M.;
Yadav, J. S.;
Agrawal, P. C.;
Chauhan, Jai Verdhan;
Manchanda, R. K.;
Chitnis, Varsha;
Paul, Biswajit;
Dedhia, Dhiraj;
Shah, Parag;
Gujar, V. M.;
Katoch, Tilak;
Kurhade, V. N.;
Madhwani, Pankaj;
Manojkumar, T. K.;
Nikam, V. A.;
Pandya, A. S.;
Parmar, J. V.;
Pawar, D. M.;
Pahari, Mayukh;
Misra, Ranjeev;
Navalgund, K. H.;
Pandiyan, R.;
Sharma, K. S.;
Subbarao, K.
Submitted: 2017-02-27, last modified: 2017-06-18
We present the calibration and background model for the Large Area X-ray
Proportional Counter (LAXPC) detectors on-board AstroSat. LAXPC instrument has
three nominally identical detectors to achieve large collecting area. These
detectors are independent of each other and in the event analysis mode, they
record the arrival time and energy of each photon that is detected. The
detectors have a time-resolution of 10 $\mu$s and a dead-time of about 42
$\mu$s. This makes LAXPC ideal for timing studies. The energy resolution and
peak channel to energy mapping were obtained from calibration on ground using
radioactive sources coupled with GEANT4 simulations of the detectors. The
response matrix was further refined from observations of the Crab X-ray source
after launch. At around 20 keV the energy resolution of detector is about
10--15\%, while the combined effective area of the 3 detectors is about 6000
cm$^2$.
[2]
oai:arXiv.org:1705.06446 [pdf] - 1583573
Large Area X-ray Proportional Counter (LAXPC) Instrument on AstroSat and
Some Preliminary Results from its performance in the orbit
Agrawal, P. C.;
Yadav, J. S.;
Antia, H. M.;
Dedhia, Dhiraj;
Shah, P.;
Chauhan, Jai Verdhan;
Manchanda, R. K.;
Chitnis, V. R.;
Gujar, V. M.;
Katoch, Tilak;
Kurhade, V. N.;
Madhwani, P.;
Manojkumar, T. K.;
Nikam, V. A.;
Pandya, A. S.;
Parmar, J. V.;
Pawar, D. M.;
Roy, Jayashree;
Paul, B.;
Pahari, Mayukh;
Misra, Ranjeev;
Ravichandran, M. H.;
Anilkumar, K.;
Joseph, C. C.;
Navalgund, K. H.;
Pandiyan, R.;
Sarma, K. S.;
Subbarao, K.
Submitted: 2017-05-18, last modified: 2017-05-25
Large Area X-ray Propositional Counter (LAXPC) instrument on AstroSat is
aimed at providing high time resolution X-ray observations in 3 to 80 keV
energy band with moderate energy resolution. To achieve large collecting area,
a cluster of three co-aligned identical LAXPC detectors, is used to realize an
effective area in access of about 6000 cm2 at 15 keV. The large detection
volume of the LAXPC detectors, filled with xenon gas at about 2 atmosphere
pressure, results in detection efficiency greater than 50%, above 30 keV. In
this article, we present salient features of the LAXPC detectors, their testing
and characterization in the laboratory prior to launch and calibration in the
orbit. Some preliminary results on timing and spectral characteristics of a few
X-ray binaries and other type of sources, are briefly discussed to demonstrate
that the LAXPC instrument is performing as planned in the orbit.
[3]
oai:arXiv.org:1609.03531 [pdf] - 1478997
Performance of Large Area X-ray Proportional Counters in a Balloon
Experiment
Roy, J.;
Agrawal, P. C.;
Dedhia, D. K.;
Manchanda, R. K.;
Shah, P. B.;
Chitnis, V. R.;
Gujar, V. M.;
Parmar, J. V.;
Pawar, D. M.;
Kurhade, V. B.
Submitted: 2016-09-12
ASTROSAT is India's first satellite fully devoted to astronomical
observations covering a wide spectral band from optical to hard X-rays by a
complement of 4 co-aligned instruments and a Scanning Sky X-ray Monitor. One of
the instruments is Large Area X-ray Proportional Counter with 3 identical
detectors. In order to assess the performance of this instrument, a balloon
experiment with two prototype Large Area X-ray Proportional Counters (LAXPC)
was carried out on 2008 April 14. The design of these LAXPCs was similar to
those on the ASTROSAT except that their field of view (FOV) was 3$^{\circ}$
$\times$ 3$^{\circ}$ versus FOV of 1$^{\circ}$ $\times$ 1$^{\circ}$ for the
LAXPCs on the ASTROSAT. The LAXPCs are aimed at the timing and spectral studies
of X-ray sources in 3-80 keV region. In the balloon experiment, the LAXPC,
associated electronics and support systems were mounted on an oriented platform
which could be pre-programmed to track any source in the sky. A brief
description of the LAXPC design, laboratory tests, calibration and the detector
characteristics is presented here. The details of the experiment and background
counting rates of the 2 LAXPCs at the float altitude of about 41 km are
presented in different energy bands. The bright black hole X-ray binary Cygnus
X-1 (Cyg X-1) was observed in the experiment for $\sim$ 3 hours. Details of Cyg
X-1 observations, count rates measured from it in different energy intervals
and the intensity variations of Cyg X-1 detected during the observations are
presented and briefly discussed.