sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Kubota, M.

Normalized to: Kubota, M.

4 article(s) in total. 21 co-authors, from 1 to 3 common article(s). Median position in authors list is 1,5.

[1]  oai:arXiv.org:1904.05699  [pdf] - 2074387
Higgs inflation in metric and Palatini formalisms: Required suppression of higher dimensional operators
Comments: 29 pages, 10 figures; minor typo correction; references added
Submitted: 2019-04-11, last modified: 2020-04-01
We investigate the sensitivity of Higgs(-like) inflation to higher dimensional operators in the nonminimal couplings and in the potential, both in the metric and Palatini formalisms. We find that, while inflationary predictions are relatively stable against the higher dimensional operators around the attractor point in the metric formalism, they are extremely sensitive in the Palatini one: for the latter, inflationary predictions are spoiled by $|\xi_4| \gtrsim 10^{-6}$ in the nonminimal couplings $(\xi_2 \phi^2 + \xi_4 \phi^4 + \cdots)R$, or by $|\lambda_6| \gtrsim 10^{-16}$ in the Jordan-frame potential $\lambda_4 \phi^4 + \lambda_6 \phi^6 + \cdots$ (both in Planck units). This extreme sensitivity results from the absence of attractor in the Palatini formalism. Our study underscores the challenge of realizing inflationary models with the nonminimal coupling in the Palatini formalism.
[2]  oai:arXiv.org:1902.05225  [pdf] - 1832250
An enigmatic hump around 30 keV in Suzaku spectra of Aquila X-1 in the Hard State
Comments: 13 pages, 7 figures, submitted to PASJ
Submitted: 2019-02-14
The typical accreting neutron star, Aquila X-1, was observed with Suzaku seven times in the decay phase of an outburst in 2007 September-October. Among them, the second to the fourth observations were performed 10 to 22 days after the outburst peak, when the source was in the hard state with a luminosity of 2x10^36 erg/sec. A unified spectral model for this type of objects approximately reproduced the 0.8--100~keV spectra obtained in these 3 observations. However, the spectra all exhibited an enigmatic hump-like excess around 30 keV, above the hard X-ray continuum which is interpreted as arising via Comptonization. The excess feature was confirmed to be significant against statistical and systematic uncertainties. It was successfully represented by a Gaussian centered at ~32 keV, with a width (sigma) of ~6 keV and an equivalent width of ~8.6 keV. Alternatively, the feature can also be explained by a recombination edge model, that produces a quasi-continuum above an edge energy of ~27 keV with an electron temperature of ~11 keV and an equivalent width of ~6.3 keV. These results are discussed in the context of atomic features of heavy elements synthesized via rapid-proton capture process during thermonuclear flashes.
[3]  oai:arXiv.org:1811.08140  [pdf] - 1857184
Discovery of Red-shifted He-like Iron Absorption Line from Luminous Accreting Neutron Star SMC X-1
Comments:
Submitted: 2018-11-20
We have analyzed X-ray data of SMC X-1 obtained with \textit{Suzaku}, and discovered a combination of an absorption line and an underlying broadened emission line centered at 6.4 keV in an observation performed on May 19, 2012. This absorption line is centered at $6.61_{-0.03}^{+0.02}$~keV with an absorption strength of $5.9_{-1.4}^{+1.7}$, naturally interpreted as an He$_{\alpha}$ resonance line of Fe at 6.7~keV that has a redshift of $4000_{-1300}^{+1400}\;\mathrm{km\;s^{-1}}$. Although \textit{Suzaku} observed this system ten times during 11 months in 2011--2012, the absorption feature has been seen only in a single observation when the NS was in a rising phase of the super-orbital modulation, which can be regarded as an egress from occultation by an extended accretion disk. We therefore attribute the line to a low density, highly ionized absorber in an accretion disk corona arising from the disk illuminated by the NS's intense X-rays. This interpretation also agrees with a discussion on the photoionization degree and the line depth.
[4]  oai:arXiv.org:1610.06677  [pdf] - 1500521
Performance of the PRAXyS X-ray Polarimeter
Comments: 8 pages, 10 figures, accepted for Nuclear Instruments and Methods in Physics Research A
Submitted: 2016-10-21
The performance of the Time Projection Chamber (TPC) polarimeter for the Polarimeter for Relativistic Astrophysical X-ray Sources (PRAXyS) Small Explorer was evaluated using polarized and unpolarized X-ray sources. The PRAXyS mission will enable exploration of the universe through X-ray polarimetry in the 2-10 keV energy band. We carried out performance tests of the polarimeter at the Brookhaven National Laboratory, National Synchrotron Light Source (BNL-NSLS) and at NASA's Goddard Space Flight Center. The polarimeter was tested with linearly polarized, monochromatic X-rays at 11 different energies between 2.5 and 8.0 keV. At maximum sensitivity, the measured modulation factors at 2.7, 4.5 and 8.0 keV are 27%, 43% and 59%, respectively and the measured angle of polarization is consistent with the expected value at all energies. Measurements with a broadband, unpolarized X-ray source placed a limit of less than 1% on false polarization in the PRAXyS polarimeter.