Kowalinski, M.
Normalized to: Kowalinski, M.
4 article(s) in total. 25 co-authors, from 1 to 4 common article(s). Median position in authors list is 4,5.
[1]
oai:arXiv.org:1806.08584 [pdf] - 1732745
Highly ionized Calcium and Argon X-ray spectra from a large solar flare
Submitted: 2018-06-22
X-ray lines of helium-like calcium (\ion{Ca}{19}) between 3.17~\AA\ and
3.21~\AA\ and associated \ion{Ca}{18} dielectronic satellites have previously
been observed in solar flare spectra, and their excitation mechanisms are well
established. Dielectronic satellites of lower ionization stages
(\ion{Ca}{17}~--~\ion{Ca}{15}) are not as well characterized. Several spectra
during a large solar flare in 2001 by the DIOGENESS X-ray spectrometer on the
{\em CORONAS-F}\/ spacecraft show the \ion{Ca}{17} and \ion{Ca}{16} satellites
as well as lines of ionized argon (\ion{Ar}{17}, \ion{Ar}{16}) including
dielectronic satellites. The DIOGENESS spectra are compared with spectra from a
synthesis code developed here based on an isothermal assumption with various
atomic sources including dielectronic satellite data from the Cowan
Hartree--Fock code. Best-fit comparisons are made by varying the temperature as
the code's input (Ar/Ca abundance ratio fixed at 0.33); close agreement is
achieved although with adjustments to some ion fractions. The derived
temperature is close to that derived from the two {\em GOES}\/ X-ray channels,
$T_{\rm GOES}$. Some lines are identified for the first time. Similar spectra
from the {\em P78-1}\/ spacecraft and the Alcator C-Mod tokamak have also been
analyzed and similar agreement obtained. The importance of blends of calcium
and argon lines is emphasized, affecting line ratios used for temperature
diagnostics. This analysis will be applied to the {\em Solar Maximum Mission}\/
Bent Crystal Spectrometer archive and to X-ray spectra expected from the ChemiX
instrument on the Sun-orbiting {\em Interhelioprobe}\/ spacecraft, while the
relevance to X-ray spectra from non-solar sources is indicated.
[2]
oai:arXiv.org:1411.0850 [pdf] - 1222982
X-ray Flare Spectra from the DIOGENESS Spectrometer and its concept
applied to ChemiX on the Interhelioprobe spacecraft
Sylwester, J.;
Kordywski, Z.;
Plocieniak, S.;
Siarkowski, M.;
Kowalinski, M.;
Nowak, S.;
Trzebinski, W.;
Steslinski, M.;
Sylwester, B.;
Stanczyk, E.;
Zawerbny, R.;
Szaforz, Z.;
Phillips, K. J. H.;
Farnik, F;
Stepanov, A.
Submitted: 2014-11-04
The {\em DIOGENESS} X-ray crystal spectrometer on the {\em CORONAS-F}
spacecraft operated for a single month (25~August to 17~September) in 2001 but
in its short lifetime obtained one hundred and forty high-resolution spectra
from some eight solar flares with {\em GOES} importance ranging from C9 to X5.
The instrument included four scanning flat crystals with wavelength ranges
covering the regions of \sixiii\ (6.65~\AA), \sxv\ (5.04~\AA), and \caxix\
(3.18~\AA) X-ray lines and associated dielectronic satellites. Two crystals
covering the \caxix\ lines were oriented in a ``Dopplerometer'' manner, i.e.
such that spatial and spectral displacements both of which commonly occur in
flares can be separated. We describe the {\em DIOGENESS} spectrometer and the
spectra obtained during flares which include lines not hitherto seen from
spacecraft instruments. An instrument with very similar concept is presently
being built for the two Russian {\em Interhelioprobe} spacecraft due for launch
in 2020 and 2022 that will make a near-encounter (perihelion $\sim 0.3$ a.u.)
to the Sun in its orbit. We outline the results that are likely to be obtained.
[3]
oai:arXiv.org:1207.4665 [pdf] - 1124954
X-raying hot plasma in solar active regions with the SphinX spectrometer
Miceli, M.;
Reale, F.;
Gburek, S.;
Terzo, S.;
Barbera, M.;
Collura, A.;
Sylwester, J.;
Kowalinski, M.;
Podgorski, P.;
Gryciuk, M.
Submitted: 2012-07-19
The detection of very hot plasma in the quiescent corona is important for
diagnosing heating mechanisms. The presence and the amount of such hot plasma
is currently debated. The SphinX instrument on-board CORONAS-PHOTON mission is
sensitive to X-ray emission well above 1 keV and provides the opportunity to
detect the hot plasma component. We analyzed the X-ray spectra of the solar
corona collected by the SphinX spectrometer in May 2009 (when two active
regions were present). We modelled the spectrum extracted from the whole Sun
over a time window of 17 days in the 1.34-7 keV energy band by adopting the
latest release of the APED database. The SphinX broadband spectrum cannot be
modelled by a single isothermal component of optically thin plasma and two
components are necessary. In particular, the high statistics and the accurate
calibration of the spectrometer allowed us to detect a very hot component at ~7
million K with an emission measure of ~2.7 x 10^44 cm^-3. The X-ray emission
from the hot plasma dominates the solar X-ray spectrum above 4 keV. We checked
that this hot component is invariably present both at high and low emission
regimes, i.e. even excluding resolvable microflares. We also present and
discuss a possible non-thermal origin (compatible with a weak contribution from
thick-target bremsstrahlung) for this hard emission component. Our results
support the nanoflare scenario and might confirm that a minor flaring activity
is ever-present in the quiescent corona, as also inferred for the coronae of
other stars.
[4]
oai:arXiv.org:1203.6809 [pdf] - 1117664
Sphinx measurements of the 2009 solar minimum x-ray emission
Sylwester, J.;
Kowalinski, M.;
Gburek, S.;
Siarkowski, M.;
Kuzin, S.;
Farnik, F.;
Reale, F.;
Phillips, K. J. H.;
Bakala, J.;
Gryciuk, M.;
Podgorski, P.;
Sylwester, B.
Submitted: 2012-03-30
The SphinX X-ray spectrophotometer on the CORONAS-PHOTON spacecraft measured
soft X-ray emission in the 1-15 keV energy range during the deep solar minimum
of 2009 with a sensitivity much greater than GOES. Several intervals are
identified when the X-ray flux was exceptionally low, and the flux and solar
X-ray luminosity are estimated. Spectral fits to the emission at these times
give temperatures of 1.7-1.9 MK and emission measures between 4 x 10^47 cm^-3
and 1.1 x 10^48 cm^-3. Comparing SphinX emission with that from the Hinode
X-ray Telescope, we deduce that most of the emission is from general coronal
structures rather than confined features like bright points. For one of 27
intervals of exceptionally low activity identified in the SphinX data, the
Sun's X-ray luminosity in an energy range roughly extrapolated to that of ROSAT
(0.1-2.4 keV) was less than most nearby K and M dwarfs.