Normalized to: Kovalenko, A.
[1]
oai:arXiv.org:1909.00785 [pdf] - 2027885
Detection statistics of the RadioAstron AGN survey
Kovalev, Y. Y.;
Kardashev, N. S.;
Sokolovsky, K. V.;
Voitsik, P. A.;
An, T.;
Anderson, J. M.;
Andrianov, A. S.;
Avdeev, V. Yu.;
Bartel, N.;
Bignall, H. E.;
Burgin, M. S.;
Edwards, P. G.;
Ellingsen, S. P.;
Frey, S.;
Garcia-Miro, C.;
Gawronski, M. P.;
Ghigo, F. D.;
Ghosh, T.;
Giovannini, G.;
Girin, I. A.;
Giroletti, M.;
Gurvits, L. I.;
Jauncey, D. L.;
Horiuchi, S.;
Ivanov, D. V.;
Kharinov, M. A.;
Koay, J. Y.;
Kostenko, V. I.;
Kovalenko, A. V.;
Kovalev, Yu. A.;
Kravchenko, E. V.;
Kunert-Bajraszewska, M.;
Kutkin, A. M.;
Likhachev, S. F.;
Lisakov, M. M.;
Litovchenko, I. D.;
McCallum, J. N.;
Melis, A.;
Melnikov, A. E.;
Migoni, C.;
Nair, D. G.;
Pashchenko, I. N.;
Phillips, C. J.;
Polatidis, A.;
Pushkarev, A. B.;
Quick, J. F. H.;
Rakhimov, I. A.;
Reynolds, C.;
Rizzo, J. R.;
Rudnitskiy, A. G.;
Savolainen, T.;
Shakhvorostova, N. N.;
Shatskaya, M. V.;
Shen, Z. -Q.;
Shchurov, M. A.;
Vermeulen, R. C.;
de Vicente, P.;
Wolak, P.;
Zensus, J. A.;
Zuga, V. A.
Submitted: 2019-09-02
The largest Key Science Program of the RadioAstron space VLBI mission is a
survey of active galactic nuclei (AGN). The main goal of the survey is to
measure and study the brightness of AGN cores in order to better understand the
physics of their emission while taking interstellar scattering into
consideration. In this paper we present detection statistics for observations
on ground-space baselines of a complete sample of radio-strong AGN at the
wavelengths of 18, 6, and 1.3 cm. Two-thirds of them are indeed detected by
RadioAstron and are found to contain extremely compact, tens to hundreds of
$\mu$as structures within their cores.
[2]
oai:arXiv.org:1710.10074 [pdf] - 1724841
Probing the gravitational redshift with an Earth-orbiting satellite
Litvinov, D. A.;
Rudenko, V. N.;
Alakoz, A. V.;
Bach, U.;
Bartel, N.;
Belonenko, A. V.;
Belousov, K. G.;
Bietenholz, M.;
Biriukov, A. V.;
Carman, R.;
Cimó, G.;
Courde, C.;
Dirkx, D.;
Duev, D. A.;
Filetkin, A. I.;
Granato, G.;
Gurvits, L. I.;
Gusev, A. V.;
Haas, R.;
Herold, G.;
Kahlon, A.;
Kanevsky, B. Z.;
Kauts, V. L.;
Kopelyansky, G. D.;
Kovalenko, A. V.;
Kronschnabl, G.;
Kulagin, V. V.;
Kutkin, A. M.;
indqvist, M. L;
Lovell, J. E. J.;
Mariey, H.;
McCallum, J.;
Molera-Calvés, G.;
Moore, C.;
Moore, K.;
Neidhardt, A.;
Plötz, C.;
Pogrebenko, S. V.;
Pollard, A.;
Porayko, N. K.;
Quick, J.;
Smirnov, A. I.;
Sokolovsky, K. V.;
Stepanyants, V. A.;
Torre, J. -M.;
de Vicente, P.;
Yang, J.;
Zakhvatkin, M. V.
Submitted: 2017-10-27
We present an approach to testing the gravitational redshift effect using the
RadioAstron satellite. The experiment is based on a modification of the Gravity
Probe A scheme of nonrelativistic Doppler compensation and benefits from the
highly eccentric orbit and ultra-stable atomic hydrogen maser frequency
standard of the RadioAstron satellite. Using the presented techniques we expect
to reach an accuracy of the gravitational redshift test of order $10^{-5}$, a
magnitude better than that of Gravity Probe A. Data processing is ongoing, our
preliminary results agree with the validity of the Einstein Equivalence
Principle.
[3]
oai:arXiv.org:1611.07168 [pdf] - 1567614
New method of 85Kr reduction in a noble gas based low-background
detector
Submitted: 2016-11-22
Krypton-85 is an anthropogenic beta-decaying isotope which produces low
energy backgrounds in dark matter and neutrino experiments, especially those
based upon liquid xenon. Several technologies have been developed to reduce the
Kr concentration in such experiments. We propose to augment those separation
technologies by first adding to the xenon an 85Kr-free sample of krypton in an
amount much larger than the natural krypton that is already present. After the
purification system reduces the total Kr concentration to the same level, the
final 85Kr concentration will have been reduced even further by the dilution
factor. A test cell for measurement of the activity of various Kr samples has
been assembled, and the activity of 25-year-old Krypton has been measured. The
measured activity agrees well with the expected activity accounting for the
85Kr abundance of the earth atmosphere in 1990 and the half-life of the
isotope. Additional tests with a Kr sample produced in the year 1944 (before
the atomic era) have been done in order to demonstrate the sensitivity of the
test cell.
[4]
oai:arXiv.org:1605.05832 [pdf] - 1408919
RadioAstron gravitational redshift experiment: status update
Litvinov, D. A.;
Bach, U.;
Bartel, N.;
Belousov, K. G.;
Bietenholz, M.;
Biriukov, A. V.;
Cimo, G.;
Duev, D. A.;
Gurvits, L. I.;
Gusev, A. V.;
Haas, R.;
Kauts, V. L.;
Kanevsky, B. Z.;
Kovalenko, A. V.;
Kronschnabl, G.;
Kulagin, V. V.;
Lindqvist, M.;
Calves, G. Molera;
Neidhardt, A.;
Ploetz, C.;
Pogrebenko, S. V.;
Porayko, N. K.;
Rudenko, V. N.;
Smirnov, A. I.;
Sokolovsky, K. V.;
Stepanyants, V. A.;
Yang, J.;
Zakhvatkin, M. V.
Submitted: 2016-05-19
A test of a cornerstone of general relativity, the gravitational redshift
effect, is currently being conducted with the RadioAstron spacecraft, which is
on a highly eccentric orbit around Earth. Using ground radio telescopes to
record the spacecraft signal, synchronized to its ultra-stable on-board
H-maser, we can probe the varying flow of time on board with unprecedented
accuracy. The observations performed so far, currently being analyzed, have
already allowed us to measure the effect with a relative accuracy of
$4\times10^{-4}$. We expect to reach $2.5\times10^{-5}$ with additional
observations in 2016, an improvement of almost a magnitude over the 40-year old
result of the GP-A mission.
[5]
oai:arXiv.org:1503.03641 [pdf] - 951898
Gravitational Redshift Experiment with the Space Radio Telescope
RadioAstron
Litvinov, D.;
Bartel, N.;
Belousov, K.;
Bietenholz, M.;
Biriukov, A.;
Fionov, A.;
Gusev, A.;
Kauts, V.;
Kovalenko, A.;
Kulagin, V.;
Poraiko, N.;
Rudenko, V.
Submitted: 2015-03-12
A unique test of general relativity is possible with the space radio
telescope RadioAstron. The ultra-stable on-board hydrogen maser frequency
standard and the highly eccentric orbit make RadioAstron an ideal instrument
for probing the gravitational redshift effect. Large gravitational potential
variation, occurring on the time scale of $\sim$24 hr, causes large variation
of the on-board H-maser clock rate, which can be detected via comparison with
frequency standards installed at various ground radio astronomical
observatories. The experiment requires specific on-board hardware operating
modes and support from ground radio telescopes capable of tracking the
spacecraft continuously and equipped with 8.4 or 15 GHz receivers. Our
preliminary estimates show that $\sim$30 hr of the space radio telescope's
observational time are required to reach $\sim 2\times10^{-5}$ accuracy in the
test, which would constitute a factor of 10 improvement over the currently
achieved best result.
[6]
oai:arXiv.org:1112.1481 [pdf] - 1092209
Position Reconstruction in a Dual Phase Xenon Scintillation Detector
Solovov, V. N.;
Belov, V. A.;
Akimov, D. Yu.;
Araújo, H. M.;
Barnes, E. J.;
Burenkov, A. A.;
Chepel, V.;
Currie, A.;
DeViveiros, L.;
Edwards, B.;
Ghag, C.;
Hollingsworth, A.;
Horn, M.;
Kalmus, G. E.;
Kobyakin, A. S.;
Kovalenko, A. G.;
Lebedenko, V. N.;
Lindote, A.;
Lopes, M. I.;
Lüscher, R.;
Majewski, P.;
Murphy, A. St J.;
Neves, F.;
Paling, S. M.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Reichhart, L.;
Scovell, P. R.;
Silva, C.;
Smith, N. J. T.;
Smith, P. F.;
Stekhanov, V. N.;
Sumner, T. J.;
Thorne, C.;
Walker, R. J.
Submitted: 2011-12-07, last modified: 2012-09-26
We studied the application of statistical reconstruction algorithms, namely
maximum likelihood and least squares methods, to the problem of event
reconstruction in a dual phase liquid xenon detector. An iterative method was
developed for in-situ reconstruction of the PMT light response functions from
calibration data taken with an uncollimated gamma-ray source. Using the
techniques described, the performance of the ZEPLIN-III dark matter detector
was studied for 122 keV gamma-rays. For the inner part of the detector (R<100
mm), spatial resolutions of 13 mm and 1.6 mm FWHM were measured in the
horizontal plane for primary and secondary scintillation, respectively. An
energy resolution of 8.1% FWHM was achieved at that energy. The possibility of
using this technique for improving performance and reducing cost of
scintillation cameras for medical applications is currently under study.
[7]
oai:arXiv.org:1110.4769 [pdf] - 1085051
WIMP-nucleon cross-section results from the second science run of
ZEPLIN-III
Akimov, D. Yu.;
Araujo, H. M.;
Barnes, E. J.;
Belov, V. A.;
Bewick, A.;
Burenkov, A. A.;
Chepel, V.;
Currie, A.;
DeViveiros, L.;
Edwards, B.;
Ghag, C.;
Hollingsworth, A.;
Horn, M.;
Jones, W. G.;
Kalmus, G. E.;
Kobyakin, A. S.;
Kovalenko, A. G.;
Lebedenko, V. N.;
Lindote, A.;
Lopes, M. I.;
Luscher, R.;
Majewski, P.;
Murphy, A. StJ.;
Neves, F.;
Paling, S. M.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Reichhart, L.;
Scovell, P. R.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Stekhanov, V. N.;
Sumner, T. J.;
Thorne, C.;
Walker, R. J.
Submitted: 2011-10-21, last modified: 2011-12-16
We report experimental upper limits on WIMP-nucleon elastic scattering cross
sections from the second science run of ZEPLIN-III at the Boulby Underground
Laboratory. A raw fiducial exposure of 1,344 kg.days was accrued over 319 days
of continuous operation between June 2010 and May 2011. A total of eight events
was observed in the signal acceptance region in the nuclear recoil energy range
7-29 keV, which is compatible with background expectations. This allows the
exclusion of the scalar cross-section above 4.8E-8 pb near 50 GeV/c^2 WIMP mass
with 90% confidence. Combined with data from the first run, this result
improves to 3.9E-8 pb. The corresponding WIMP-neutron spin-dependent
cross-section limit is 8.0E-3 pb. The ZEPLIN programme reaches thus its
conclusion at Boulby, having deployed and exploited successfully three liquid
xenon experiments of increasing reach.
[8]
oai:arXiv.org:1111.2248 [pdf] - 1091528
Quenching Factor for Low Energy Nuclear Recoils in a Plastic
Scintillator
Reichhart, L.;
Akimov, D. Yu.;
Araujo, H. M.;
Barnes, E. J.;
Belov, V. A.;
Burenkov, A. A.;
Chepel, V.;
Currie, A.;
DeViveiros, L.;
Edwards, B.;
Francis, V.;
Ghag, C.;
Hollingsworth, A.;
Horn, M.;
Kalmus, G. E.;
Kobyakin, A. S.;
Kovalenko, A. G.;
Lebedenko, V. N.;
Lindote, A.;
Lopes, M. I.;
Luscher, R.;
Majewski, P.;
Murphy, A. St J.;
Neves, F.;
Paling, S. M.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Scovell, P. R.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Stekhanov, V. N.;
Sumner, T. J.;
Thorne, C.;
Walker, R. J.
Submitted: 2011-11-09
Plastic scintillators are widely used in industry, medicine and scientific
research, including nuclear and particle physics. Although one of their most
common applications is in neutron detection, experimental data on their
response to low-energy nuclear recoils are scarce. Here, the relative
scintillation efficiency for neutron-induced nuclear recoils in a
polystyrene-based plastic scintillator (UPS-923A) is presented, exploring
recoil energies between 125 keV and 850 keV. Monte Carlo simulations,
incorporating light collection efficiency and energy resolution effects, are
used to generate neutron scattering spectra which are matched to observed
distributions of scintillation signals to parameterise the energy-dependent
quenching factor. At energies above 300 keV the dependence is reasonably
described using the semi-empirical formulation of Birks and a kB factor of
(0.014+/-0.002) g/MeVcm^2 has been determined. Below that energy the measured
quenching factor falls more steeply than predicted by the Birks formalism.
[9]
oai:arXiv.org:1106.0808 [pdf] - 1077078
ZE3RA: The ZEPLIN-III Reduction and Analysis Package
Neves, F.;
Akimov, D. Yu.;
Araújo, H. M.;
Barnes, E. J.;
Belov, V. A.;
Burenkov, A. A.;
Chepel, V.;
Currie, A.;
DeViveiros, L.;
Edwards, B.;
Ghag, C.;
Hollingsworth, A.;
Horn, M.;
Kalmus, G. E.;
Kobyakin, A. S.;
Kovalenko, A. G.;
Lebedenko, V. N.;
Lindote, A.;
Lopes, M. I.;
Lüscher, R.;
Majewski, P.;
Murphy, A. St J.;
Paling, S. M.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Reichhart, L.;
Rodrigues, S.;
Scovell, P. R.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Stekhanov, V. N.;
Sumner, T. J.;
Thorne, C.;
Walker, R. J.
Submitted: 2011-06-04
ZE3RA is the software package responsible for processing the raw data from
the ZEPLIN-III dark matter experiment and its reduction into a set of
parameters used in all subsequent analyses. The detector is a liquid xenon time
projection chamber with scintillation and electroluminescence signals read out
by an array of 31 photomultipliers. The dual range 62-channel data stream is
optimised for the detection of scintillation pulses down to a single
photoelectron and of ionisation signals as small as those produced by single
electrons. We discuss in particular several strategies related to data
filtering, pulse finding and pulse clustering which are tuned to recover the
best electron/nuclear recoil discrimination near the detection threshold, where
most dark matter elastic scattering signatures are expected. The software was
designed assuming only minimal knowledge of the physics underlying the
detection principle, allowing an unbiased analysis of the experimental results
and easy extension to other detectors with similar requirements.
[10]
oai:arXiv.org:1103.0393 [pdf] - 385243
Performance of the veto detector incorporated into the ZEPLIN-III
experiment
Ghag, C.;
Akimov, D. Yu.;
Araújo, H. M.;
Barnes, E. J.;
Belov, V. A.;
Burenkov, A. A.;
Chepel, V.;
Currie, A.;
DeViveiros, L.;
Edwards, B.;
Francis, V.;
Hollingsworth, A.;
Horn, M.;
Kalmus, G. E.;
Kobyakin, A. S.;
Kovalenko, A. G.;
Lebedenko, V. N.;
Lindote, A.;
Lopes, M. I.;
Lüscher, R.;
Lyons, K.;
Majewski, P.;
St, A.;
Murphy, J.;
Neves, F.;
Paling, S. M.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Reichhart, L.;
Scovell, P. R.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Stekhanov, V. N.;
Sumner, T. J.;
Thorne, C.;
Walker, R. J.
Submitted: 2011-03-02, last modified: 2011-05-01
The ZEPLIN-III experiment is operating in its second phase at the Boulby
Underground Laboratory in search of dark matter WIMPs. The major upgrades to
the instrument over its first science run include lower background
photomultiplier tubes and installation of a plastic scintillator veto system.
Performance results from the veto detector using calibration and science data
in its first six months of operation in coincidence with ZEPLIN-III are
presented. With fully automated operation and calibration, the veto system has
maintained high stability and achieves near unity live time relative to
ZEPLIN-III. Calibrations with a neutron source demonstrate a rejection of 60%
of neutron-induced nuclear recoils in ZEPLIN-III that might otherwise be
misidentified as WIMPs. This tagging efficiency reduces the expected untagged
nuclear recoil background from neutrons during science data taking to a very
low rate of ~0.2 events per year in the WIMP acceptance region. Additionally,
the veto detector provides rejection of 28% of gamma-ray induced background
events, allowing the sampling of the dominant source of background in
ZEPLIN-III - multiple scatter gamma-rays with rare topologies. Since WIMPs will
not be tagged by the veto detector, and tags due to gamma-rays and neutrons are
separable, this population of multiple scatter events may be characterised
without biasing the analysis of candidate WIMP signals in the data.
[11]
oai:arXiv.org:1004.4207 [pdf] - 325335
The ZEPLIN-III Anti-Coincidence Veto Detector
Akimov, D. Yu.;
Araujo, H. M.;
Barnes, E. J.;
Belov, V. A.;
Burenkov, A. A.;
Chepel, V.;
Currie, A.;
Edwards, B.;
Francis, V.;
Ghag, C.;
Hollingsworth, A.;
Horn, M.;
Kalmus, G. E.;
Kobyakin, A. S.;
Kovalenko, A. G.;
Lebedenko, V. N.;
Lindote, A.;
Lopes, M. I.;
Luscher, R.;
Lyons, K.;
Majewski, P.;
Murphy, A. StJ.;
Neves, F.;
Paling, S. M.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Reichhart, L.;
Scovell, P. R.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Stekhanov, V. N.;
Sumner, T. J.;
Taylor, R.;
Thorne, C.;
Walker, R. J.
Submitted: 2010-04-23, last modified: 2010-04-27
The design, optimisation and construction of an anti-coincidence veto
detector to complement the ZEPLIN-III direct dark matter search instrument is
described. One tonne of plastic scintillator is arranged into 52 bars
individually read out by photomultipliers and coupled to a gadolinium-loaded
passive polypropylene shield. Particular attention has been paid to
radiological content. The overall aim has been to achieve a veto detector of
low threshold and high efficiency without the creation of additional background
in ZEPLIN-III, all at a reasonable cost. Extensive experimental measurements of
the components have been made, including radioactivity levels and performance
characteristics. These have been used to inform a complete end-to-end Monte
Carlo simulation that has then been used to calculate the expected performance
of the new instrument, both operating alone and as an anti-coincidence detector
for ZEPLIN-III. The veto device will be capable of rejecting over 65% of
coincident nuclear recoil events from neutron background in the energy range of
interest in ZEPLIN-III. This will reduce the background in ZEPLIN-III from ~0.4
to ~0.14 events per year in the WIMP acceptance region, a significant factor in
the event of a non-zero observation. Furthermore, in addition to providing
valuable diagnostic capabilities, the veto is capable of tagging over 15% for
gamma-ray rejection, all whilst contributing no significant additional
background. In conjunction with the replacement of the internal ZEPLIN-III
photomultiplier array, the new veto is expected to improve significantly the
sensitivity of the ZEPLIN-III instrument to dark matter, allowing spin
independent WIMP-nucleon cross sections below 1E-8 pb to be probed.
[12]
oai:arXiv.org:0812.1150 [pdf] - 19200
Results from the First Science Run of the ZEPLIN-III Dark Matter Search
Experiment
Lebedenko, V. N.;
Araujo, H. M.;
Barnes, E. J.;
Bewick, A.;
Cashmore, R.;
Chepel, V.;
Currie, A.;
Davidge, D.;
Dawson, J.;
Durkin, T.;
Edwards, B.;
Ghag, C.;
Horn, M.;
Howard, A. S.;
Hughes, A. J.;
Jones, W. G.;
Joshi, M.;
Kalmus, G. E.;
Kovalenko, A. G.;
Lindote, A.;
Liubarsky, I.;
Lopes, M. I.;
Luscher, R.;
Majewski, P.;
Murphy, A. StJ.;
Neves, F.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Scovell, P. R.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Stekhanov, V. N.;
Sumner, T. J.;
Thorne, C.;
Walker, R. J.
Submitted: 2008-12-05, last modified: 2009-09-02
The ZEPLIN-III experiment in the Palmer Underground Laboratory at Boulby uses
a 12kg two-phase xenon time projection chamber to search for the weakly
interacting massive particles (WIMPs) that may account for the dark matter of
our Galaxy. The detector measures both scintillation and ionisation produced by
radiation interacting in the liquid to differentiate between the nuclear
recoils expected from WIMPs and the electron recoil background signals down to
~10keV nuclear recoil energy. An analysis of 847kg.days of data acquired
between February 27th 2008 and May 20th 2008 has excluded a WIMP-nucleon
elastic scattering spin-independent cross-section above 8.1x10(-8)pb at
55GeV/c2 with a 90% confidence limit. It has also demonstrated that the
two-phase xenon technique is capable of better discrimination between electron
and nuclear recoils at low-energy than previously achieved by other xenon-based
experiments.
[13]
oai:arXiv.org:astro-ph/0605500 [pdf] - 82187
The ZEPLIN-III dark matter detector: instrument design, manufacture and
commissioning
Akimov, D. Yu.;
Alner, G. J.;
Araujo, H. M.;
Bewick, A.;
Bungau, C.;
Burenkov, A. A.;
Carson, M. J.;
Chepel, V.;
Cline, D.;
Davidge, D.;
Davies, J. C.;
Daw, E.;
Dawson, J.;
Durkin, T.;
Edwards, B.;
Gamble, T.;
Chag, C.;
Hollingworth, R. J.;
Howard, A. S.;
Jones, W. G.;
Joshi, M.;
Kirkpatrick, J.;
Kovalenko, A.;
Kudryavtsev, V. A.;
Kuznetsov, I. S.;
Lawson, T.;
Lebedenko, V. N.;
Lewin, J. D.;
Lightfoot, P.;
Lindote, A.;
Liubarsky, I.;
Lopes, M. I.;
Luscher, R.;
McMillan, J. E.;
Morgan, B.;
Muna, D.;
Murphy, A. S.;
Neves, F.;
Nicklin, G. G.;
Paling, S. M.;
Muna, D.;
da Cunha, J. Pinto;
Plank, S. J. S.;
Preece, R.;
Quenby, J. J.;
Robinson, M.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Spooner, N. J. C.;
Stekhanov, V.;
Sumner, T. J.;
Thorne, C.;
Tovey, D. R.;
Tziaferi, E.;
Walker, R. J.;
Wang, H.;
White, J.;
Wolfs, F.
Submitted: 2006-05-19
We present details of the technical design and manufacture of the ZEPLIN-III
dark matter experiment. ZEPLIN-III is a two-phase xenon detector which measures
both the scintillation light and the ionisation charge generated in the liquid
by interacting particles and radiation. The instrument design is driven by both
the physics requirements and by the technology requirements surrounding the use
of liquid xenon. These include considerations of key performance parameters,
such as the efficiency of scintillation light collection, restrictions placed
on the use of materials to control the inherent radioactivity levels,
attainment of high vacuum levels and chemical contamination control. The
successful solution has involved a number of novel design and manufacturing
features which will be of specific use to future generations of direct dark
matter search experiments as they struggle with similar and progressively more
demanding requirements.
[14]
oai:arXiv.org:astro-ph/0603243 [pdf] - 80452
The ZEPLIN-III dark matter detector: performance study using an
end-to-end simulation tool
Araujo, H. M.;
Akimov, D. Yu.;
Alner, G. J.;
Bewick, A.;
Bungau, C.;
Camanzi, B.;
Carson, M. J.;
Chepel, V.;
Chagani, H.;
Davidge, D.;
Davies, J. C.;
Daw, E.;
Dawson, J.;
Durkin, T.;
Edwards, B.;
Gamble, T.;
Ghag, C.;
Hollingworth, R.;
Howard, A. S.;
Jones, W. G.;
Joshi, M.;
Kirkpatrick, J.;
Kovalenko, A.;
Kudryavtsev, V. A.;
Lebedenko, V. N.;
Lawson, T.;
Lewin, J. D.;
Lightfoot, P.;
Lindote, A.;
Liubarsky, I.;
Lopes, M. I.;
Luscher, R.;
Majewski, P.;
Mavrokoridis, K.;
McMillan, J.;
Morgan, B.;
Muna, D.;
Murphy, A. S.;
Neves, F.;
Nicklin, G.;
Paling, S.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Robinson, M.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Spooner, N. J. C.;
Stekhanov, V.;
Sumner, T. J.;
Tovey, D. R.;
Thorne, C.;
Tziaferi, E.;
Walker, R. J.
Submitted: 2006-03-09
We present results from a GEANT4-based Monte Carlo tool for end-to-end
simulations of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase
detector which measures both the scintillation light and the ionisation charge
generated in liquid xenon by interacting particles and radiation. The software
models the instrument response to radioactive backgrounds and calibration
sources, including the generation, ray-tracing and detection of the primary and
secondary scintillations in liquid and gaseous xenon, and subsequent processing
by data acquisition electronics. A flexible user interface allows easy
modification of detector parameters at run time. Realistic datasets can be
produced to help with data analysis, an example of which is the position
reconstruction algorithm developed from simulated data. We present a range of
simulation results confirming the original design sensitivity of a few times
$10^{-8}$ pb to the WIMP-nucleon cross-section.
[15]
oai:arXiv.org:astro-ph/0007391 [pdf] - 37229
Space-VLBI observations of OH maser OH34.26+0.15: low interstellar
scattering
Slysh, V. I.;
Voronkov, M. A.;
Migenes, V.;
Shibata, K. M.;
Umemoto, T.;
Altunin, V. I.;
Valtts, I. E.;
Kanevsky, B. Z.;
Popov, M. V.;
Kovalenko, A. V.;
Fomalont, E. B.;
Poperechenko, B. A.;
Gorshenkov, Yu. N.;
Carlson, B. R.;
Dougherty, S. M.;
Reynolds, J. E.;
Jiang, D. R.;
Smirnov, A. I.;
Grachev, V. G.
Submitted: 2000-07-26
We report on the first space-VLBI observations of the OH34.26+0.15 maser in
two main line OH transitions at 1665 and 1667 MHz. The observations involved
the space radiotelescope on board the Japanese satellite HALCA and an array of
ground radio telescopes. The map of the maser region and images of individual
maser spots were produced with an angular resolution of 1 milliarcsec which is
several times higher than the angular resolution available on the ground. The
maser spots were only partly resolved and a lower limit to the brightness
temperature 6x10^{12} K was obtained. The maser seems to be located in the
direction of low interstellar scattering, an order of magnitude lower than the
scattering of a nearby extragalactic source and pulsar.