sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Kok, Yitping

Normalized to: Kok, Y.

21 article(s) in total. 190 co-authors, from 1 to 13 common article(s). Median position in authors list is 6,0.

[1]  oai:arXiv.org:1807.09409  [pdf] - 1725096
Detection of the gravitational redshift in the orbit of the star S2 near the Galactic centre massive black hole
Comments: Accepted for publication in A&A Letters, 29 June 2018, 10 pages, 6 figures, corresponding author: F. Eisenhauer <eisenhau@mpe.mpg.de>
Submitted: 2018-07-24
The highly elliptical, 16-year-period orbit of the star S2 around the massive black hole candidate Sgr A* is a sensitive probe of the gravitational field in the Galactic centre. Near pericentre at 120 AU, ~1400 Schwarzschild radii, the star has an orbital speed of ~7650 km/s, such that the first-order effects of Special and General Relativity have now become detectable with current capabilities. Over the past 26 years, we have monitored the radial velocity and motion on the sky of S2, mainly with the SINFONI and NACO adaptive optics instruments on the ESO Very Large Telescope, and since 2016 and leading up to the pericentre approach in May 2018, with the four-telescope interferometric beam-combiner instrument GRAVITY. From data up to and including pericentre, we robustly detect the combined gravitational redshift and relativistic transverse Doppler effect for S2 of z ~ 200 km/s / c with different statistical analysis methods. When parameterising the post-Newtonian contribution from these effects by a factor f, with f = 0 and f = 1 corresponding to the Newtonian and general relativistic limits, respectively, we find from posterior fitting with different weighting schemes f = 0.90 +/- 0.09 (stat) +\- 0.15 (sys). The S2 data are inconsistent with pure Newtonian dynamics.
[2]  oai:arXiv.org:1705.02345  [pdf] - 1583163
First Light for GRAVITY: Phase Referencing Optical Interferometry for the Very Large Telescope Interferometer
GRAVITY Collaboration; Abuter, R.; Accardo, M.; Amorim, A.; Anugu, N.; Ávila, G.; Azouaoui, N.; Benisty, M.; Berger, J. P.; Blind, N.; Bonnet, H.; Bourget, P.; Brandner, W.; Brast, R.; Buron, A.; Burtscher, L.; Cassaing, F.; Chapron, F.; Choquet, É.; Clénet, Y.; Collin, C.; Foresto, V. Coudé du; de Wit, W.; de Zeeuw, P. T.; Deen, C.; Delplancke-Ströbele, F.; Dembet, R.; Derie, F.; Dexter, J.; Duvert, G.; Ebert, M.; Eckart, A.; Eisenhauer, F.; Esselborn, M.; Fédou, P.; Finger, G.; Garcia, P.; Dabo, C. E. Garcia; Lopez, R. Garcia; Gendron, E.; Genzel, R.; Gillessen, S.; Gonte, F.; Gordo, P.; Grould, M.; Grözinger, U.; Guieu, S.; Haguenauer, P.; Hans, O.; Haubois, X.; Haug, M.; Haussmann, F.; Henning, Th.; Hippler, S.; Horrobin, M.; Huber, A.; Hubert, Z.; Hubin, N.; Hummel, C. A.; Jakob, G.; Janssen, A.; Jochum, L.; Jocou, L.; Kaufer, A.; Kellner, S.; Kern, L.; Kervella, P.; Kiekebusch, M.; Klein, R.; Kok, Y.; Kolb, J.; Kulas, M.; Lacour, S.; Lapeyrère, V.; Lazareff, B.; Bouquin, J. -B. Le; Lèna, P.; Lenzen, R.; Lévêque, S.; Lippa, M.; Magnard, Y.; Mehrgan, L.; Mellein, M.; Mérand, A.; Moreno-Ventas, J.; Moulin, T.; Müller, E.; Müller, F.; Neumann, U.; Oberti, S.; Ott, T.; Pallanca, L.; Panduro, J.; Pasquini, L.; Paumard, T.; Percheron, I.; Perraut, K.; Perrin, G.; Pflüger, A.; Pfuhl, O.; Duc, T. Phan; Plewa, P. M.; Popovic, D.; Rabien, S.; Ramírez, A.; Ramos, J.; Rau, C.; Riquelme, M.; Rohloff, R. -R.; Rousset, G.; Sanchez-Bermudez, J.; Scheithauer, S.; Schöller, M.; Schuhler, N.; Spyromilio, J.; Straubmeier, C.; Sturm, E.; Suarez, M.; Tristram, K. R. W.; Ventura, N.; Vincent, F.; Waisberg, I.; Wank, I.; Weber, J.; Wieprecht, E.; Wiest, M.; Wiezorrek, E.; Wittkowski, M.; Woillez, J.; Wolff, B.; Yazici, S.; Ziegler, D.; Zins, G.
Comments: Accepted for publication in A&A, 23 pages, 23 figures, corresponding author: F. Eisenhauer <eisenhau@mpe.mpg.de>
Submitted: 2017-05-05
GRAVITY is a new instrument to coherently combine the light of the European Southern Observatory Very Large Telescope Interferometer to form a telescope with an equivalent 130 m diameter angular resolution and a collecting area of 200 m$^2$. The instrument comprises fiber fed integrated optics beam combination, high resolution spectroscopy, built-in beam analysis and control, near-infrared wavefront sensing, phase-tracking, dual beam operation and laser metrology [...]. This article gives an overview of GRAVITY and reports on the performance and the first astronomical observations during commissioning in 2015/16. We demonstrate phase tracking on stars as faint as m$_K$ ~ 10 mag, phase-referenced interferometry of objects fainter than m$_K$ ~ 15 mag with a limiting magnitude of m$_K$ ~ 17 mag, minute long coherent integrations, a visibility accuracy of better than 0.25 %, and spectro-differential phase and closure phase accuracy better than 0.5{\deg}, corresponding to a differential astrometric precision of better than 10 microarcseconds ({\mu}as). The dual-beam astrometry, measuring the phase difference of two objects with laser metrology, is still under commissioning. First observations show residuals as low as 50 {\mu}as when following objects over several months. We illustrate the instrument performance with the observations of archetypical objects for the different instrument modes. Examples include the Galactic Center supermassive black hole and its fast orbiting star S2 for phase referenced dual beam observations and infrared wavefront sensing, the High Mass X-Ray Binary BP Cru and the Active Galactic Nucleus of PDS 456 for few {\mu}as spectro-differential astrometry, the T Tauri star S CrA for a spectro-differential visibility analysis, {\xi} Tel and 24 Cap for high accuracy visibility observations, and {\eta} Car for interferometric imaging with GRAVITY.
[3]  oai:arXiv.org:1705.02351  [pdf] - 1996654
Sub-milliarcsecond Optical Interferometry of the HMXB BP Cru with VLTI/GRAVITY
Comments: Submitted to ApJ, 22 pages, 17 figures
Submitted: 2017-05-05
We observe the HMXB BP Cru using interferometry in the near-infrared K band with VLTI/GRAVITY. Continuum visibilities are at most partially resolved, consistent with the predicted size of the hypergiant. Differential visibility amplitude ($\Delta |V| \sim 5\%$) and phase ($\Delta \phi \sim 2 \deg$) signatures are observed across the HeI $2.059 \mu$m and Br$\gamma$ lines, the latter seen strongly in emission, unusual for the donor star's spectral type. For a baseline $B \sim 100$m, the differential phase RMS $\sim 0.2 \deg$ corresponds to an astrometric precision of $\sim 2 \mu$as. A model-independent analysis in the marginally resolved limit of interferometry reveals asymmetric and extended emission with a strong wavelength dependence. We propose geometric models based on an extended and distorted wind and/or a high density gas stream, which has long been predicted to be present in this system. The observations show that optical interferometry is now able to resolve HMXBs at the spatial scale at which accretion takes place, and therefore probe the effects of the gravitational and radiation fields of the compact object on its environment.
[4]  oai:arXiv.org:1705.02359  [pdf] - 1583169
Accretion-ejection morphology of the microquasar SS433 resolved at sub-au scale
Comments: Submitted for publication in A&A Letters, 4 pages + appendix, 4 figures. Comments welcome
Submitted: 2017-05-05
We present the first optical observation at sub-milliarcsecond (mas) scale of the microquasar SS 433 obtained with the GRAVITY instrument on the VLT interferometer. The 3.5 hour exposure reveals a rich K-band spectrum dominated by hydrogen Br$\gamma\ $ and \ion{He}{i} lines, as well as (red-shifted) emission lines coming from the jets. The K-band continuum emitting region is dominated by a marginally resolved point source ($<$ 1 mas) embedded inside a diffuse background accounting for 10\% of the total flux. The jet line positions agree well with the ones expected from the jet kinematic model, an interpretation also supported by the consistent sign (i.e. negative/positive for the receding/approaching jet component) of the phase shifts observed in the lines. The significant visibility drop across the jet lines, together with the small and nearly identical phases for all baselines, point toward a jet that is offset by less than 0.5 mas from the continuum source and resolved in the direction of propagation, with a typical size of 2 mas. The jet position angle of $\sim$80$^{\circ}$ is consistent with the expected one at the observation date. Jet emission so close to the central binary system would suggest that line locking, if relevant to explain the amplitude and stability of the 0.26c jet velocity, operates on elements heavier than hydrogen. The Br$\gamma\ $ profile is broad and double peaked. It is better resolved than the continuum and the change of the phase signal sign across the line on all baselines suggests an East-West oriented geometry alike the jet direction and supporting a (polar) disk wind origin.
[5]  oai:arXiv.org:1608.04888  [pdf] - 1458639
The metrology system of the VLTI instrument GRAVITY
Comments: 9 pages, 5 figures
Submitted: 2016-08-17
The VLTI instrument GRAVITY combines the beams from four telescopes and provides phase-referenced imaging as well as precision-astrometry of order 10 microarcseconds by observing two celestial objects in dual-field mode. Their angular separation can be determined from their differential OPD (dOPD) when the internal dOPDs in the interferometer are known. Here, we present the general overview of the novel metrology system which performs these measurements. The metrology consists of a three-beam laser system and a homodyne detection scheme for three-beam interference using phase-shifting interferometry in combination with lock-in amplifiers. Via this approach the metrology system measures dOPDs on a nanometer-level.
[6]  oai:arXiv.org:1503.07303  [pdf] - 970999
GRAVITY: the VLTI 4-beam combiner for narrow-angle astrometry and interferometric imaging
Comments: 8 pages, 3 figures. Proceeding of the conference "Fiber optics in astronomy IV". The follwoing authors made significant contribution regarding the work on fibers reported in this paper (ordered by institute and alphabetical order): IPAG: L. Jocou, K. Perraut; LESIA: R. Dembet, P. Fedou, S. Lacour, G. Perrin; MPE: N. Blind, F. Eisenhauer, S. Gillessen,, Y. Kok, M. Lippa
Submitted: 2015-03-25
GRAVITY is the second generation Very Large Telescope Interferometer instrument for precision narrow-angle astrometry and interferometric imaging in the Near Infra-Red (NIR). It shall provide precision astrometry of order 10 microarcseconds, and imaging capability at a few milliarcsecond resolution, and hence will revolutionise dynamical measurements of celestial objects. GRAVITY is currently in the last stages of its integration and tests in Garching at MPE, and will be delivered to the VLT Interferometer (VLTI) in 2015. We present here the instrument, with a particular focus on the components making use of fibres: integrated optics beam combiners, polarisation rotators, fibre differential delay lines, and the metrology.
[7]  oai:arXiv.org:1501.05822  [pdf] - 925683
The GRAVITY instrument software / High-level software
Comments: 8 pages, 7 figures, published in Proc. SPIE 9146, Optical and Infrared Interferometry IV, 91462B
Submitted: 2015-01-23
GRAVITY is the four-beam, near- infrared, AO-assisted, fringe tracking, astrometric and imaging instrument for the Very Large Telescope Interferometer (VLTI). It is requiring the development of one of the most complex instrument software systems ever built for an ESO instrument. Apart from its many interfaces and interdependencies, one of the most challenging aspects is the overall performance and stability of this complex system. The three infrared detectors and the fast reflective memory network (RMN) recorder contribute a total data rate of up to 20 MiB/s accumulating to a maximum of 250 GiB of data per night. The detectors, the two instrument Local Control Units (LCUs) as well as the five LCUs running applications under TAC (Tools for Advanced Control) architecture, are interconnected with fast Ethernet, RMN fibers and dedicated fiber connections as well as signals for the time synchronization. Here we give a simplified overview of all subsystems of GRAVITY and their interfaces and discuss two examples of high-level applications during observations: the acquisition procedure and the gathering and merging of data to the final FITS file.
[8]  oai:arXiv.org:1501.04738  [pdf] - 923534
The GRAVITY metrology system: narrow-angle astrometry via phase-shifting interferometry
Comments: 11 pages, 7 figures
Submitted: 2015-01-20
The VLTI instrument GRAVITY will provide very powerful astrometry by combining the light from four telescopes for two objects simultaneously. It will measure the angular separation between the two astronomical objects to a precision of 10 microarcseconds. This corresponds to a differential optical path difference (dOPD) between the targets of few nanometers and the paths within the interferometer have to be maintained stable to that level. For this purpose, the novel metrology system of GRAVITY will monitor the internal dOPDs by means of phase-shifting interferometry. We present the four-step phase-shifting concept of the metrology with emphasis on the method used for calibrating the phase shifts. The latter is based on a phase-step insensitive algorithm which unambiguously extracts phases in contrast to other methods that are strongly limited by non-linearities of the phase-shifting device. The main constraint of this algorithm is to introduce a robust ellipse fitting routine. Via this approach we are able to measure phase shifts in the laboratory with a typical accuracy of lambda/2000 or 1 nanometer of the metrology wavelength.
[9]  oai:arXiv.org:1412.1696  [pdf] - 904702
The fiber coupler and beam stabilization system of the GRAVITY interferometer
Comments: 14 pages, 13 figures. Proceedings of the SPIE 9146 "Optical and Infrared Interferometry IV"
Submitted: 2014-12-04
We present the installed and fully operational beam stabilization and fiber injection subsystem feeding the 2nd generation VLTI instrument GRAVITY. The interferometer GRAVITY requires an unprecedented stability of the VLTI optical train to achieve micro-arcsecond astrometry. For this purpose, GRAVITY contains four fiber coupler units, one per telescope. Each unit is equipped with actuators to stabilize the telescope beam in terms of tilt and lateral pupil displacement, to rotate the field, to adjust the polarization and to compensate atmospheric piston. A special roof-prism offers the possibility of on-axis as well as off-axis fringe tracking without changing the optical train. We describe the assembly, integration and alignment and the resulting optical quality and performance of the individual units. Finally, we present the closed-loop performance of the tip-tilt and pupil tracking achieved with the final systems in the lab.
[10]  oai:arXiv.org:1408.5327  [pdf] - 863862
Alternative approach to precision narrow-angle astrometry for Antarctic long baseline interferometry
Comments: SPIE Astronomical Telescopes and Instrumentation conference, June 2014, Paper ID 9146-103, 17 pages, 13 figures
Submitted: 2014-08-22
The conventional approach to high-precision narrow-angle astrometry using a long baseline interferometer is to directly measure the fringe packet separation of a target and a nearby reference star. This is done by means of a technique known as phase-referencing which requires a network of dual beam combiners and laser metrology systems. Using an alternative approach that does not rely on phase-referencing, the narrow-angle astrometry of several closed binary stars (with separation less than 2$"$), as described in this paper, was carried out by observing the fringe packet crossing event of the binary systems. Such an event occurs twice every sidereal day when the line joining the two stars of the binary is is perpendicular to the projected baseline of the interferometer. Observation of these events is well suited for an interferometer in Antarctica. Proof of concept observations were carried out at the Sydney University Stellar Interferometer (SUSI) with targets selected according to its geographical location. Narrow-angle astrometry using this indirect approach has achieved sub-100 micro-arcsecond precision.
[11]  oai:arXiv.org:1407.6669  [pdf] - 861906
The GRAVITY metrology system: modeling a metrology in optical fibers
Comments: 20 pages, 19 figures. Proceeding of SPIE 9146 "Optical and Infrared Interferometry IV"
Submitted: 2014-07-24
GRAVITY is the second generation VLT Interferometer (VLTI) instrument for high-precision narrow-angle astrometry and phase-referenced interferometric imaging. The laser metrology system of GRAVITY is at the heart of its astrometric mode, which must measure the distance of 2 stars with a precision of 10 micro-arcseconds. This means the metrology has to measure the optical path difference between the two beam combiners of GRAVITY to a level of 5 nm. The metrology design presents some non-common paths that have consequently to be stable at a level of 1 nm. Otherwise they would impact the performance of GRAVITY. The various tests we made in the past on the prototype give us hints on the components responsible for this error, and on their respective contribution to the total error. It is however difficult to assess their exact origin from only OPD measurements, and therefore, to propose a solution to this problem. In this paper, we present the results of a semi-empirical modeling of the fibered metrology system, relying on theoretical basis, as well as on characterisations of key components. The modeling of the metrology system regarding various effects, e.g., temperature, waveguide heating or mechanical stress, will help us to understand how the metrology behave. The goals of this modeling are to 1) model the test set-ups and reproduce the measurements (as a validation of the modeling), 2) determine the origin of the non-common path errors, and 3) propose modifications to the current metrology design to reach the required 1nm stability.
[12]  oai:arXiv.org:1407.6660  [pdf] - 861905
GRAVITY: the Calibration Unit
Comments: 12 pages, 11 figures. Proceeding of SPIE 9146 "Optical and Infrared Interferometry IV"
Submitted: 2014-07-24
We present in this paper the design and characterisation of a new sub-system of the VLTI 2nd generation instrument GRAVITY: the Calibration Unit. The Calibration Unit provides all functions to test and calibrate the beam combiner instrument: it creates two artificial stars on four beams, and dispose of four delay lines with an internal metrology. It also includes artificial stars for the tip-tilt and pupil guiding systems, as well as four metrology pick-up diodes, for tests and calibration of the corresponding sub-systems. The calibration unit also hosts the reference targets to align GRAVITY to the VLTI, and the safety shutters to avoid the metrology light to propagate in the VLTI-lab. We present the results of the characterisation and validtion of these differrent sub-units.
[13]  oai:arXiv.org:1407.4281  [pdf] - 1215705
The interferometric baselines and GRAVITY astrometric error budget
Comments: SPIE Meeting 2014 -- Montreal
Submitted: 2014-07-16
GRAVITY is a new generation beam combination instrument for the VLTI. Its goal is to achieve microarsecond astrometric accuracy between objects separated by a few arcsec. This $10^6$ accuracy on astrometric measurements is the most important challenge of the instrument, and careful error budget have been paramount during the technical design of the instrument. In this poster, we will focus on baselines induced errors, which is part of a larger error budget.
[14]  oai:arXiv.org:1404.1014  [pdf] - 862631
Reaching micro-arcsecond astrometry with long baseline optical interferometry; application to the GRAVITY instrument
Comments: 14 pages. Accepted by A&A
Submitted: 2014-04-03, last modified: 2014-05-24
A basic principle of long baseline interferometry is that an optical path difference (OPD) directly translates into an astrometric measurement. In the simplest case, the OPD is equal to the scalar product between the vector linking the two telescopes and the normalized vector pointing toward the star. However, a too simple interpretation of this scalar product leads to seemingly conflicting results, called here "the baseline paradox". For micro-arcsecond accuracy astrometry, we have to model in full the metrology measurement. It involves a complex system subject to many optical effects: from pure baseline errors to static, quasi-static and high order optical aberrations. The goal of this paper is to present the strategy used by the "General Relativity Analysis via VLT InTerferometrY" instrument (GRAVITY) to minimize the biases introduced by these defects. It is possible to give an analytical formula on how the baselines and tip-tilt errors affect the astrometric measurement. This formula depends on the limit-points of three type of baselines: the wide-angle baseline, the narrow-angle baseline, and the imaging baseline. We also, numerically, include non-common path higher-order aberrations, whose amplitude were measured during technical time at the Very Large Telescope Interferometer. We end by simulating the influence of high-order common-path aberrations due to atmospheric residuals calculated from a Monte-Carlo simulation tool for Adaptive optics systems. The result of this work is an error budget of the biases caused by the multiple optical imperfections, including optical dispersion. We show that the beam stabilization through both focal and pupil tracking is crucial to the GRAVITY system. Assuming the instrument pupil is stabilized at a 4 cm level on M1, and a field tracking below 0.2$\lambda/D$, we show that GRAVITY will be able to reach its objective of 10$\mu$as accuracy.
[15]  oai:arXiv.org:1311.7497  [pdf] - 752999
Phase-referenced Interferometry and Narrow-angle Astrometry with SUSI
Comments: 35 pages, 51 figures, accepted for publication in JAI
Submitted: 2013-11-29
The Sydney University Stellar Interferometer (SUSI) now incorporates a new beam combiner, called the Microarcsecond University of Sydney Companion Astrometry instrument (MUSCA), for the purpose of high precision differential astrometry of bright binary stars. Operating in the visible wavelength regime where photon-counting and post-processing fringe tracking is possible, MUSCA will be used in tandem with SUSI's primary beam combiner, Precision Astronomical Visible Observations (PAVO), to record high spatial resolution fringes and thereby measure the separation of fringe packets of binary stars. In its current phase of development, the dual beam combiner configuration has successfully demonstrated for the first time a dual-star phase-referencing operation in visible wavelengths. This paper describes the beam combiner optics and hardware, the network of metrology systems employed to measure every non-common path between the two beam combiners and also reports on a recent narrow-angle astrometric observation of $\delta$ Orionis A (HR 1852) as the project enters its on-sky testing phase.
[16]  oai:arXiv.org:1309.3811  [pdf] - 1179234
Long-Baseline Interferometric Multiplicity Survey of the Sco-Cen OB Association
Comments: 7 figures, 5 tables, accepted for publication in MNRAS
Submitted: 2013-09-15
We present the first multiplicity-dedicated long baseline optical interferometric survey of the Scorpius-Centaurus-Lupus-Crux association. We used the Sydney University Stellar Interferometer to undertake a survey for new companions to 58 Sco-Cen B- type stars and have detected 24 companions at separations ranging from 7-130mas, 14 of which are new detections. Furthermore, we use a Bayesian analysis and all available information in the literature to determine the multiplicity distribution of the 58 stars in our sample, showing that the companion frequency is F = 1.35 and the mass ratio distribution is best described as a power law with exponent equal to -0.46, agreeing with previous Sco-Cen high mass work and differing significantly from lower-mass stars in Tau-Aur. Based on our analysis, we estimate that among young B-type stars in moving groups, up to 23% are apparently single stars. This has strong implications for the understanding of high-mass star formation, which requires angular momentum dispersal through some mechanism such as formation of multiple systems.
[17]  oai:arXiv.org:1307.7589  [pdf] - 1173031
Searching for solar-like oscillations in the delta Scuti star rho Puppis
Comments: 14 pages, 12 figure, accepted for MNRAS
Submitted: 2013-07-29
Despite the shallow convective envelopes of delta Scuti pulsators, solar-like oscillations are theoretically predicted to be excited in those stars as well. To search for such stochastic oscillations we organised a spectroscopic multi-site campaign for the bright, metal-rich delta Sct star rho Puppis. We obtained a total of 2763 high-resolution spectra using four telescopes. We discuss the reduction and analysis with the iodine cell technique, developed for searching for low-amplitude radial velocity variations, in the presence of high-amplitude variability. Furthermore, we have determined the angular diameter of rho Puppis to be 1.68 \pm 0.03 mas, translating into a radius of 3.52 \pm 0.07Rsun. Using this value, the frequency of maximum power of possible solar-like oscillations, is expected at ~43 \pm 2 c/d (498 \pm 23 muHz). The dominant delta Scuti-type pulsation mode of rho Puppis is known to be the radial fundamental mode which allows us to determine the mean density of the star, and therefore an expected large frequency separation of 2.73 c/d (31.6 muHz). We conclude that 1) the radial velocity amplitudes of the delta Scuti pulsations are different for different spectral lines; 2) we can exclude solar-like oscillations to be present in rho Puppis with an amplitude per radial mode larger than 0.5 m/s.
[18]  oai:arXiv.org:1306.5937  [pdf] - 684435
Optical Interferometry of early-type stars with PAVO@CHARA. I. Fundamental stellar properties
Comments: 13 pages, 9 figures, accepted for publication in MNRAS
Submitted: 2013-06-25
We present interferometric observations of 7 main-sequence and 3 giant stars with spectral types from B2 to F6 using the PAVO beam combiner at the CHARA array. We have directly determined the angular diameters for these objects with an average precision of 2.3%. We have also computed bolometric fluxes using available photometry in the visible and infrared wavelengths, as well as space-based ultraviolet spectroscopy. Combined with precise \textit{Hipparcos} parallaxes, we have derived a set of fundamental stellar properties including linear radius, luminosity and effective temperature. Fitting the latter to computed isochrone models, we have inferred masses and ages of the stars. The effective temperatures obtained are in good agreement (at a 3% level) with nearly-independent temperature estimations from spectroscopy. They validate recent sixth-order polynomial (B-V)-$T_\mathrm{eff}$ empirical relations \citep{Boyajian2012a}, but suggest that a more conservative third-order solution \citep{vanBelle2009} could adequately describe the (V-K)-$T_\mathrm{eff}$ relation for main-sequence stars of spectral type A0 and later. Finally, we have compared mass values obtained combining surface gravity with inferred stellar radius (\textit{gravity mass}) and as a result of the comparison of computed luminosity and temperature values with stellar evolutionary models (\textit{isochrone mass}). The strong discrepancy between isochrone and gravity mass obtained for one of the observed stars, $\gamma$\,Lyr, suggests that determination of the stellar atmosphere parameters should be revised.
[19]  oai:arXiv.org:1304.0086  [pdf] - 1165626
A low cost scheme for high precision dual-wavelength laser metrology
Comments: 17 pages, 4 figures, accepted for publication in Applied Optics
Submitted: 2013-03-30
A novel method capable of delivering relative optical path length metrology with nanometer precision is demonstrated. Unlike conventional dual-wavelength metrology which employs heterodyne detection, the method developed in this work utilizes direct detection of interference fringes of two He-Ne lasers as well as a less precise stepper motor open-loop position control system to perform its measurement. Although the method may be applicable to a variety of circumstances, the specific application where this metrology is essential is in an astrometric optical long baseline stellar interferometer dedicated to precise measurement of stellar positions. In our example application of this metrology to a narrow-angle astrometric interferometer, measurement of nanometer precision could be achieved without frequency-stabilized lasers although the use of such lasers would extend the range of optical path length the metrology can accurately measure. Implementation of the method requires very little additional optics or electronics, thus minimizing cost and effort of implementation. Furthermore, the optical path traversed by the metrology lasers is identical with that of the starlight or science beams, even down to using the same photodetectors, thereby minimizing the non-common-path between metrology and science channels.
[20]  oai:arXiv.org:1303.3658  [pdf] - 1165273
Science and Technology Progress at the Sydney University Stellar Interferometer
Comments: 10 pages, 9 Figures
Submitted: 2013-03-14
This paper presents an overview of recent progress at the Sydney University Stellar Interferometer (SUSI). Development of the third-generation PAVO beam combiner has continued. The MUSCA beam combiner for high-precision differential astrometry using visible light phase referencing is under active development and will be the subject of a separate paper. Because SUSI was one of the pioneering interferometric instruments, some of its original systems are old and have become difficult to maintain. We are undertaking a campaign of modernization of systems: (1) an upgrade of the Optical Path Length Compensator IR laser metrology counter electronics from a custom system which uses an obsolete single-board computer to a modern one based on an FPGA interfaced to a Linux computer - in addition to improving maintainability, this upgrade should allow smoother motion and higher carriage speeds; (2) the replacement of the aged single-board computer local controllers for the siderostats and the longitudinal dispersion compensator has been completed; (3) the large beam reducing telescope has been replaced with a pair of smaller units with separate accessible foci. Examples of scientific results are also included.
[21]  oai:arXiv.org:1302.7139  [pdf] - 1164921
Simulating a dual beam combiner at SUSI for narrow-angle astrometry
Comments: 28 pages, 23 figures, accepted for publication in Experimental Astronomy. The final publication is available at http://link.springer.com
Submitted: 2013-02-28
The Sydney University Stellar Interferometer (SUSI) has two beam combiners, i.e. the Precision Astronomical Visible Observations (PAVO) and the Microarcsecond University of Sydney Companion Astrometry (MUSCA). The primary beam combiner, PAVO, can be operated independently and is typically used to measure properties of binary stars of less than 50 milliarc- sec (mas) separation and the angular diameters of single stars. On the other hand, MUSCA was recently installed and must be used in tandem with the for- mer. It is dedicated for microarcsecond precision narrow-angle astrometry of close binary stars. The performance evaluation and development of the data reduction pipeline for the new setup was assisted by an in-house computer simulation tool developed for this and related purposes. This paper describes the framework of the simulation tool, simulations carried out to evaluate the performance of each beam combiner and the expected astrometric precision of the dual beam combiner setup, both at SUSI and possible future sites.