Normalized to: Kok, Y.
[1]
oai:arXiv.org:1807.09409 [pdf] - 1725096
Detection of the gravitational redshift in the orbit of the star S2 near
the Galactic centre massive black hole
GRAVITY Collaboration;
Abuter, R.;
Amorim, A.;
Anugu, N.;
Bauböck, M.;
Benisty, M.;
Berger, J. P.;
Blind, N.;
Bonnet, H.;
Brandner, W.;
Buron, A.;
Collin, C.;
Chapron, F.;
Clénet, Y.;
Foresto, V. Coudé du;
de Zeeuw, P. T.;
Deen, C.;
Delplancke-Ströbele, F.;
Dembet, R.;
Dexter, J.;
Duvert, G.;
Eckart, A.;
Eisenhauer, F.;
Finger, G.;
Schreiber, N. M. Förster;
Fédou, P.;
Garcia, P.;
Lopez, R. Garcia;
Gao, F.;
Gendron, E.;
Genzel, R.;
Gillessen, S.;
Gordo, P.;
Habibi, M.;
Haubois, X.;
Haug, M.;
Haußmann, F.;
Henning, Th.;
Hippler, S.;
Horrobin, M.;
Hubert, Z.;
Hubin, N.;
Rosales, A. Jimenez;
Jochum, L.;
Jocou, L.;
Kaufer, A.;
Kellner, S.;
Kendrew, S.;
Kervella, P.;
Kok, Y.;
Kulas, M.;
Lacour, S.;
Lapeyrère, V.;
Lazareff, B.;
Bouquin, J. -B. Le;
Léna, P.;
Lippa, M.;
Lenzen, R.;
Mérand, A.;
Müller, E.;
Neumann, U.;
Ott, T.;
Palanca, L.;
Paumard, T.;
Pasquini, L.;
Perraut, K.;
Perrin, G.;
Pfuhl, O.;
Plewa, P. M.;
Rabien, S.;
Ramírez, A.;
Ramos, J.;
Rau, C.;
Rodríguez-Coira, G.;
Rohloff, R. -R.;
Rousset, G.;
Sanchez-Bermudez, J.;
Scheithauer, S.;
Schöller, M.;
Schuler, N.;
Spyromilio, J.;
Straub, O.;
Straubmeier, C.;
Sturm, E.;
Tacconi, L. J.;
Tristram, K. R. W.;
Vincent, F.;
von Fellenberg, S.;
Wank, I.;
Waisberg, I.;
Widmann, F.;
Wieprecht, E.;
Wiest, M.;
Wiezorrek, E.;
Woillez, J.;
Yazici, S.;
Ziegler, D.;
Zins, G.
Submitted: 2018-07-24
The highly elliptical, 16-year-period orbit of the star S2 around the massive
black hole candidate Sgr A* is a sensitive probe of the gravitational field in
the Galactic centre. Near pericentre at 120 AU, ~1400 Schwarzschild radii, the
star has an orbital speed of ~7650 km/s, such that the first-order effects of
Special and General Relativity have now become detectable with current
capabilities. Over the past 26 years, we have monitored the radial velocity and
motion on the sky of S2, mainly with the SINFONI and NACO adaptive optics
instruments on the ESO Very Large Telescope, and since 2016 and leading up to
the pericentre approach in May 2018, with the four-telescope interferometric
beam-combiner instrument GRAVITY. From data up to and including pericentre, we
robustly detect the combined gravitational redshift and relativistic transverse
Doppler effect for S2 of z ~ 200 km/s / c with different statistical analysis
methods. When parameterising the post-Newtonian contribution from these effects
by a factor f, with f = 0 and f = 1 corresponding to the Newtonian and general
relativistic limits, respectively, we find from posterior fitting with
different weighting schemes f = 0.90 +/- 0.09 (stat) +\- 0.15 (sys). The S2
data are inconsistent with pure Newtonian dynamics.
[2]
oai:arXiv.org:1705.02345 [pdf] - 1583163
First Light for GRAVITY: Phase Referencing Optical Interferometry for
the Very Large Telescope Interferometer
GRAVITY Collaboration;
Abuter, R.;
Accardo, M.;
Amorim, A.;
Anugu, N.;
Ávila, G.;
Azouaoui, N.;
Benisty, M.;
Berger, J. P.;
Blind, N.;
Bonnet, H.;
Bourget, P.;
Brandner, W.;
Brast, R.;
Buron, A.;
Burtscher, L.;
Cassaing, F.;
Chapron, F.;
Choquet, É.;
Clénet, Y.;
Collin, C.;
Foresto, V. Coudé du;
de Wit, W.;
de Zeeuw, P. T.;
Deen, C.;
Delplancke-Ströbele, F.;
Dembet, R.;
Derie, F.;
Dexter, J.;
Duvert, G.;
Ebert, M.;
Eckart, A.;
Eisenhauer, F.;
Esselborn, M.;
Fédou, P.;
Finger, G.;
Garcia, P.;
Dabo, C. E. Garcia;
Lopez, R. Garcia;
Gendron, E.;
Genzel, R.;
Gillessen, S.;
Gonte, F.;
Gordo, P.;
Grould, M.;
Grözinger, U.;
Guieu, S.;
Haguenauer, P.;
Hans, O.;
Haubois, X.;
Haug, M.;
Haussmann, F.;
Henning, Th.;
Hippler, S.;
Horrobin, M.;
Huber, A.;
Hubert, Z.;
Hubin, N.;
Hummel, C. A.;
Jakob, G.;
Janssen, A.;
Jochum, L.;
Jocou, L.;
Kaufer, A.;
Kellner, S.;
Kern, L.;
Kervella, P.;
Kiekebusch, M.;
Klein, R.;
Kok, Y.;
Kolb, J.;
Kulas, M.;
Lacour, S.;
Lapeyrère, V.;
Lazareff, B.;
Bouquin, J. -B. Le;
Lèna, P.;
Lenzen, R.;
Lévêque, S.;
Lippa, M.;
Magnard, Y.;
Mehrgan, L.;
Mellein, M.;
Mérand, A.;
Moreno-Ventas, J.;
Moulin, T.;
Müller, E.;
Müller, F.;
Neumann, U.;
Oberti, S.;
Ott, T.;
Pallanca, L.;
Panduro, J.;
Pasquini, L.;
Paumard, T.;
Percheron, I.;
Perraut, K.;
Perrin, G.;
Pflüger, A.;
Pfuhl, O.;
Duc, T. Phan;
Plewa, P. M.;
Popovic, D.;
Rabien, S.;
Ramírez, A.;
Ramos, J.;
Rau, C.;
Riquelme, M.;
Rohloff, R. -R.;
Rousset, G.;
Sanchez-Bermudez, J.;
Scheithauer, S.;
Schöller, M.;
Schuhler, N.;
Spyromilio, J.;
Straubmeier, C.;
Sturm, E.;
Suarez, M.;
Tristram, K. R. W.;
Ventura, N.;
Vincent, F.;
Waisberg, I.;
Wank, I.;
Weber, J.;
Wieprecht, E.;
Wiest, M.;
Wiezorrek, E.;
Wittkowski, M.;
Woillez, J.;
Wolff, B.;
Yazici, S.;
Ziegler, D.;
Zins, G.
Submitted: 2017-05-05
GRAVITY is a new instrument to coherently combine the light of the European
Southern Observatory Very Large Telescope Interferometer to form a telescope
with an equivalent 130 m diameter angular resolution and a collecting area of
200 m$^2$. The instrument comprises fiber fed integrated optics beam
combination, high resolution spectroscopy, built-in beam analysis and control,
near-infrared wavefront sensing, phase-tracking, dual beam operation and laser
metrology [...]. This article gives an overview of GRAVITY and reports on the
performance and the first astronomical observations during commissioning in
2015/16. We demonstrate phase tracking on stars as faint as m$_K$ ~ 10 mag,
phase-referenced interferometry of objects fainter than m$_K$ ~ 15 mag with a
limiting magnitude of m$_K$ ~ 17 mag, minute long coherent integrations, a
visibility accuracy of better than 0.25 %, and spectro-differential phase and
closure phase accuracy better than 0.5{\deg}, corresponding to a differential
astrometric precision of better than 10 microarcseconds ({\mu}as). The
dual-beam astrometry, measuring the phase difference of two objects with laser
metrology, is still under commissioning. First observations show residuals as
low as 50 {\mu}as when following objects over several months. We illustrate the
instrument performance with the observations of archetypical objects for the
different instrument modes. Examples include the Galactic Center supermassive
black hole and its fast orbiting star S2 for phase referenced dual beam
observations and infrared wavefront sensing, the High Mass X-Ray Binary BP Cru
and the Active Galactic Nucleus of PDS 456 for few {\mu}as spectro-differential
astrometry, the T Tauri star S CrA for a spectro-differential visibility
analysis, {\xi} Tel and 24 Cap for high accuracy visibility observations, and
{\eta} Car for interferometric imaging with GRAVITY.
[3]
oai:arXiv.org:1705.02351 [pdf] - 1996654
Sub-milliarcsecond Optical Interferometry of the HMXB BP Cru with
VLTI/GRAVITY
GRAVITY Collaboration;
Waisberg, I.;
Dexter, J.;
Pfuhl, O.;
Abuter, R.;
Amorin, A.;
Anugu, N.;
Berger, J. P.;
Blind, N.;
Bonnet, H.;
Brandner, W.;
Buron, A.;
Clénet, Y.;
de Wit, W.;
Deen, C.;
Delplancke-Ströbele, F.;
Dembet, R.;
Duvert, G.;
Eckart, A.;
Eisenhauer, F.;
Fédou, P.;
Finger, G.;
Garcia, P.;
Lopez, R. Garcia;
Gendron, E.;
Genzel, R.;
Gillessen, S.;
Haubois, X.;
Haug, M.;
Haussmann, F.;
Henning, Th.;
Hippler, S.;
Horrobin, M.;
Hubert, Z.;
Jochum, L.;
Jocou, L.;
Kervella, P.;
Kok, Y.;
Kulas, M.;
Lacour, S.;
Lapeyrère, V.;
Bouquin, J. -B. Le;
Lèna, P.;
Lippa, M.;
Mérand, A.;
Müller, E.;
Ott, T.;
Pallanca, L.;
Panduro, J.;
Paumard, T.;
Perraut, K.;
Perrin, G.;
Rabien, S.;
Ramírez, A.;
Ramos, J.;
Rau, C.;
Rohloff, R. -R.;
Rousset, G.;
Sanchez-Bermudez, J.;
Scheithauer, S.;
Schöller, M.;
Straubmeier, C.;
Sturm, E.;
Vincent, F.;
Wank, I.;
Wieprecht, E.;
Wiest, M.;
Wiezorrek, E.;
Wittkowski, M.;
Woillez, J.;
Yazici, S.
Submitted: 2017-05-05
We observe the HMXB BP Cru using interferometry in the near-infrared K band
with VLTI/GRAVITY. Continuum visibilities are at most partially resolved,
consistent with the predicted size of the hypergiant. Differential visibility
amplitude ($\Delta |V| \sim 5\%$) and phase ($\Delta \phi \sim 2 \deg$)
signatures are observed across the HeI $2.059 \mu$m and Br$\gamma$ lines, the
latter seen strongly in emission, unusual for the donor star's spectral type.
For a baseline $B \sim 100$m, the differential phase RMS $\sim 0.2 \deg$
corresponds to an astrometric precision of $\sim 2 \mu$as. A model-independent
analysis in the marginally resolved limit of interferometry reveals asymmetric
and extended emission with a strong wavelength dependence. We propose geometric
models based on an extended and distorted wind and/or a high density gas
stream, which has long been predicted to be present in this system. The
observations show that optical interferometry is now able to resolve HMXBs at
the spatial scale at which accretion takes place, and therefore probe the
effects of the gravitational and radiation fields of the compact object on its
environment.
[4]
oai:arXiv.org:1705.02359 [pdf] - 1583169
Accretion-ejection morphology of the microquasar SS433 resolved at
sub-au scale
GRAVITY Collaboration;
Petrucci, P. -O.;
Waisberg, I.;
Bouquin, J. -B. Le;
Dexter, J.;
Dubus, G.;
Perraut, K.;
Kervella, P.;
Abuter, R.;
Amorim, A.;
Anugu, N.;
Berger, J. P.;
Blind, N.;
Bonnet, H.;
Brandner, W.;
Buron, A.;
Choquet, É.;
Clénet, Y.;
de Wit, W.;
Deen, C.;
Eckart, A.;
Eisenhauer, F.;
Finger, G.;
Garcia, P.;
Lopez, R. Garcia;
Gendron, E.;
Genzel, R.;
Gillessen, S.;
Gonte, F.;
Haubois, X.;
Haug, M.;
Haussmann, F.;
Henning, Th.;
Hippler, S.;
Horrobin, M.;
Hubert, Z.;
Jochum, L.;
Jocou, L.;
Kok, Y.;
Kolb, J.;
Kulas, M.;
Lacour, S.;
Lazareff, B.;
Lèna, P.;
Lippa, M.;
Mérand, A.;
Müller, E.;
Ott, T.;
Panduro, J.;
Paumard, T.;
Perrin, G.;
Pfuhl, O.;
Ramos, J.;
Rau, C.;
Rohloff, R. -R.;
Rousset, G.;
Sanchez-Bermudez, J.;
Scheithauer, S.;
Schöller, M.;
Straubmeier, C.;
Sturm, E.;
Vincent, F.;
Wank, I.;
Wieprecht, E.;
Wiest, M.;
Wiezorrek, E.;
Wittkowski, M.;
Woillez, J.;
Yazici, S.;
Zins, G.
Submitted: 2017-05-05
We present the first optical observation at sub-milliarcsecond (mas) scale of
the microquasar SS 433 obtained with the GRAVITY instrument on the VLT
interferometer. The 3.5 hour exposure reveals a rich K-band spectrum dominated
by hydrogen Br$\gamma\ $ and \ion{He}{i} lines, as well as (red-shifted)
emission lines coming from the jets. The K-band continuum emitting region is
dominated by a marginally resolved point source ($<$ 1 mas) embedded inside a
diffuse background accounting for 10\% of the total flux. The jet line
positions agree well with the ones expected from the jet kinematic model, an
interpretation also supported by the consistent sign (i.e. negative/positive
for the receding/approaching jet component) of the phase shifts observed in the
lines. The significant visibility drop across the jet lines, together with the
small and nearly identical phases for all baselines, point toward a jet that is
offset by less than 0.5 mas from the continuum source and resolved in the
direction of propagation, with a typical size of 2 mas. The jet position angle
of $\sim$80$^{\circ}$ is consistent with the expected one at the observation
date. Jet emission so close to the central binary system would suggest that
line locking, if relevant to explain the amplitude and stability of the 0.26c
jet velocity, operates on elements heavier than hydrogen. The Br$\gamma\ $
profile is broad and double peaked. It is better resolved than the continuum
and the change of the phase signal sign across the line on all baselines
suggests an East-West oriented geometry alike the jet direction and supporting
a (polar) disk wind origin.
[5]
oai:arXiv.org:1608.04888 [pdf] - 1458639
The metrology system of the VLTI instrument GRAVITY
Lippa, Magdalena;
Gillessen, Stefan;
Blind, Nicolas;
Kok, Yipting;
Yazici, Senol;
Weber, Johannes;
Pfuhl, Oliver;
Haug, Marcus;
Kellner, Stefan;
Wieprecht, Ekkehard;
Eisenhauer, Frank;
Genzel, Reinhard;
Hans, Oliver;
Haussmann, Frank;
Huber, David;
Kratschmann, Tobias;
Ott, Thomas;
Plattner, Markus;
Rau, Christian;
Sturm, Eckhard;
Waisberg, Idel;
Wiezorrek, Erich;
Perrin, Guy;
Perraut, Karine;
Brandner, Wolfgang;
Straubmeier, Christian;
Amorim, Antonio
Submitted: 2016-08-17
The VLTI instrument GRAVITY combines the beams from four telescopes and
provides phase-referenced imaging as well as precision-astrometry of order 10
microarcseconds by observing two celestial objects in dual-field mode. Their
angular separation can be determined from their differential OPD (dOPD) when
the internal dOPDs in the interferometer are known. Here, we present the
general overview of the novel metrology system which performs these
measurements. The metrology consists of a three-beam laser system and a
homodyne detection scheme for three-beam interference using phase-shifting
interferometry in combination with lock-in amplifiers. Via this approach the
metrology system measures dOPDs on a nanometer-level.
[6]
oai:arXiv.org:1503.07303 [pdf] - 970999
GRAVITY: the VLTI 4-beam combiner for narrow-angle astrometry and
interferometric imaging
Blind, N.;
Eisenhauer, F.;
Gillessen, S.;
Kok, Y.;
Lippa, M.;
Perrin, G.;
Dembet, R.;
Fedou, P.;
Lacour, S.;
Perraut, K.;
Jocou, L.;
Burtscher, L.;
Hans, O.;
Haug, M.;
Haussmann, F.;
Huber, S.;
Janssen, A.;
Kellner, S.;
Ott, T.;
Pfuhl, O.;
Sturm, E.;
Weber, J.;
Wieprecht, E.;
Amorim, A.;
Brandner, W.;
Straubmeier, C.
Submitted: 2015-03-25
GRAVITY is the second generation Very Large Telescope Interferometer
instrument for precision narrow-angle astrometry and interferometric imaging in
the Near Infra-Red (NIR). It shall provide precision astrometry of order 10
microarcseconds, and imaging capability at a few milliarcsecond resolution, and
hence will revolutionise dynamical measurements of celestial objects. GRAVITY
is currently in the last stages of its integration and tests in Garching at
MPE, and will be delivered to the VLT Interferometer (VLTI) in 2015. We present
here the instrument, with a particular focus on the components making use of
fibres: integrated optics beam combiners, polarisation rotators, fibre
differential delay lines, and the metrology.
[7]
oai:arXiv.org:1501.05822 [pdf] - 925683
The GRAVITY instrument software / High-level software
Burtscher, Leonard;
Wieprecht, Ekkehard;
Ott, Thomas;
Kok, Yitping;
Yazici, Senol;
Anugu, Narsireddy;
Dembet, Roderick;
Fedou, Pierre;
Lacour, Sylvestre;
Ott, Juergen;
Paumard, Thibaut;
Lapeyrere, Vincent;
Kervella, Pierre;
Abuter, Roberto;
Pozna, Eszter;
Eisenhauer, Frank;
Blind, Nicolas;
Genzel, Reinhard;
Gillessen, Stefan;
Hans, Oliver;
Haug, Marcus;
Haussmann, Frank;
Kellner, Stefan;
Lippa, Magdalena;
Pfuhl, Oliver;
Sturm, Eckhard;
Weber, Johannes;
Amorim, Antonio;
Brandner, Wolfgang;
Rousselet-Perraut, Karine;
Perrin, Guy S.;
Straubmeier, Christian;
Schoeller, Markus
Submitted: 2015-01-23
GRAVITY is the four-beam, near- infrared, AO-assisted, fringe tracking,
astrometric and imaging instrument for the Very Large Telescope Interferometer
(VLTI). It is requiring the development of one of the most complex instrument
software systems ever built for an ESO instrument. Apart from its many
interfaces and interdependencies, one of the most challenging aspects is the
overall performance and stability of this complex system. The three infrared
detectors and the fast reflective memory network (RMN) recorder contribute a
total data rate of up to 20 MiB/s accumulating to a maximum of 250 GiB of data
per night. The detectors, the two instrument Local Control Units (LCUs) as well
as the five LCUs running applications under TAC (Tools for Advanced Control)
architecture, are interconnected with fast Ethernet, RMN fibers and dedicated
fiber connections as well as signals for the time synchronization. Here we give
a simplified overview of all subsystems of GRAVITY and their interfaces and
discuss two examples of high-level applications during observations: the
acquisition procedure and the gathering and merging of data to the final FITS
file.
[8]
oai:arXiv.org:1501.04738 [pdf] - 923534
The GRAVITY metrology system: narrow-angle astrometry via phase-shifting
interferometry
Lippa, M.;
Blind, N.;
Gillessen, S.;
Kok, Y.;
Weber, J.;
Eisenhauer, F.;
Pfuhl, O.;
Janssen, A.;
Haug, M.;
Haußmann, F.;
Kellner, S.;
Hans, O.;
Wieprecht, E.;
Ott, T.;
Burtscher, L.;
Genzel, R.;
Sturm, E.;
Hofmann, R.;
Huber, S.;
Huber, D.;
Senftleben, S.;
Pflüger, A.;
Greßmann, R.;
Perrin, G.;
Perraut, K.;
Brandner, W.;
Straubmeier, C.;
Amorim, A.;
Schöller, M.
Submitted: 2015-01-20
The VLTI instrument GRAVITY will provide very powerful astrometry by
combining the light from four telescopes for two objects simultaneously. It
will measure the angular separation between the two astronomical objects to a
precision of 10 microarcseconds. This corresponds to a differential optical
path difference (dOPD) between the targets of few nanometers and the paths
within the interferometer have to be maintained stable to that level. For this
purpose, the novel metrology system of GRAVITY will monitor the internal dOPDs
by means of phase-shifting interferometry. We present the four-step
phase-shifting concept of the metrology with emphasis on the method used for
calibrating the phase shifts. The latter is based on a phase-step insensitive
algorithm which unambiguously extracts phases in contrast to other methods that
are strongly limited by non-linearities of the phase-shifting device. The main
constraint of this algorithm is to introduce a robust ellipse fitting routine.
Via this approach we are able to measure phase shifts in the laboratory with a
typical accuracy of lambda/2000 or 1 nanometer of the metrology wavelength.
[9]
oai:arXiv.org:1412.1696 [pdf] - 904702
The fiber coupler and beam stabilization system of the GRAVITY
interferometer
Pfuhl, O.;
Haug, M.;
Eisenhauer, F.;
Kellner, S.;
Haussmann, F.;
Perrin, G.;
Gillessen, S.;
Straubmeier, C.;
Ott, T.;
Rousselet-Perraut, K.;
Amorim, A.;
Lippa, M.;
Janssen, A.;
Brandner, W.;
Kok, Y.;
Blind, N.;
Burtscher, L.;
Sturm, E.;
Wieprecht, E.;
Schoeller, M.;
Weber, J.;
Hans, O.;
Huber, S.
Submitted: 2014-12-04
We present the installed and fully operational beam stabilization and fiber
injection subsystem feeding the 2nd generation VLTI instrument GRAVITY. The
interferometer GRAVITY requires an unprecedented stability of the VLTI optical
train to achieve micro-arcsecond astrometry. For this purpose, GRAVITY contains
four fiber coupler units, one per telescope. Each unit is equipped with
actuators to stabilize the telescope beam in terms of tilt and lateral pupil
displacement, to rotate the field, to adjust the polarization and to compensate
atmospheric piston. A special roof-prism offers the possibility of on-axis as
well as off-axis fringe tracking without changing the optical train. We
describe the assembly, integration and alignment and the resulting optical
quality and performance of the individual units. Finally, we present the
closed-loop performance of the tip-tilt and pupil tracking achieved with the
final systems in the lab.
[10]
oai:arXiv.org:1408.5327 [pdf] - 863862
Alternative approach to precision narrow-angle astrometry for Antarctic
long baseline interferometry
Submitted: 2014-08-22
The conventional approach to high-precision narrow-angle astrometry using a
long baseline interferometer is to directly measure the fringe packet
separation of a target and a nearby reference star. This is done by means of a
technique known as phase-referencing which requires a network of dual beam
combiners and laser metrology systems. Using an alternative approach that does
not rely on phase-referencing, the narrow-angle astrometry of several closed
binary stars (with separation less than 2$"$), as described in this paper, was
carried out by observing the fringe packet crossing event of the binary
systems. Such an event occurs twice every sidereal day when the line joining
the two stars of the binary is is perpendicular to the projected baseline of
the interferometer. Observation of these events is well suited for an
interferometer in Antarctica. Proof of concept observations were carried out at
the Sydney University Stellar Interferometer (SUSI) with targets selected
according to its geographical location. Narrow-angle astrometry using this
indirect approach has achieved sub-100 micro-arcsecond precision.
[11]
oai:arXiv.org:1407.6669 [pdf] - 861906
The GRAVITY metrology system: modeling a metrology in optical fibers
Blind, N.;
Huber, H.;
Eisenhauer, F.;
Weber, J.;
Gillessen, S.;
Lippa, M.;
Burtscher, L.;
Hans, O.;
Haug, M.;
Haussmann, F.;
Huber, S.;
Janssen, A.;
Kellner, S.;
Kok, Y.;
Ott, T.;
Pfuhl, O.;
Sturm, E.;
Wieprecht, E.;
Amorim, A.;
Brandner, W.;
Perrin, G.;
Perraut, K.;
Straubmeier, C.
Submitted: 2014-07-24
GRAVITY is the second generation VLT Interferometer (VLTI) instrument for
high-precision narrow-angle astrometry and phase-referenced interferometric
imaging. The laser metrology system of GRAVITY is at the heart of its
astrometric mode, which must measure the distance of 2 stars with a precision
of 10 micro-arcseconds. This means the metrology has to measure the optical
path difference between the two beam combiners of GRAVITY to a level of 5 nm.
The metrology design presents some non-common paths that have consequently to
be stable at a level of 1 nm. Otherwise they would impact the performance of
GRAVITY. The various tests we made in the past on the prototype give us hints
on the components responsible for this error, and on their respective
contribution to the total error. It is however difficult to assess their exact
origin from only OPD measurements, and therefore, to propose a solution to this
problem. In this paper, we present the results of a semi-empirical modeling of
the fibered metrology system, relying on theoretical basis, as well as on
characterisations of key components. The modeling of the metrology system
regarding various effects, e.g., temperature, waveguide heating or mechanical
stress, will help us to understand how the metrology behave. The goals of this
modeling are to 1) model the test set-ups and reproduce the measurements (as a
validation of the modeling), 2) determine the origin of the non-common path
errors, and 3) propose modifications to the current metrology design to reach
the required 1nm stability.
[12]
oai:arXiv.org:1407.6660 [pdf] - 861905
GRAVITY: the Calibration Unit
Blind, N.;
Eisenhauer, F.;
Haug, M.;
Gillessen, S.;
Lippa, M.;
Burtscher, L.;
Hans, O.;
Haussmann, F.;
Huber, S.;
Janssen, A.;
Kellner, S.;
Kok, Y.;
Ott, T.;
Pfuhl, O.;
Sturm, E.;
Weber, J.;
Wieprecht, E.;
Amorim, A.;
Brandner, W.;
Perrin, G.;
Perraut, K.;
Straubmeier, C.
Submitted: 2014-07-24
We present in this paper the design and characterisation of a new sub-system
of the VLTI 2nd generation instrument GRAVITY: the Calibration Unit. The
Calibration Unit provides all functions to test and calibrate the beam combiner
instrument: it creates two artificial stars on four beams, and dispose of four
delay lines with an internal metrology. It also includes artificial stars for
the tip-tilt and pupil guiding systems, as well as four metrology pick-up
diodes, for tests and calibration of the corresponding sub-systems. The
calibration unit also hosts the reference targets to align GRAVITY to the VLTI,
and the safety shutters to avoid the metrology light to propagate in the
VLTI-lab. We present the results of the characterisation and validtion of these
differrent sub-units.
[13]
oai:arXiv.org:1407.4281 [pdf] - 1215705
The interferometric baselines and GRAVITY astrometric error budget
Lacour, S.;
Eisenhauer, F.;
Gillessen, S.;
Pfuhl, O.;
Kok, Y.;
Perrin, G.;
Rousselet-Perraut, K.;
Straubmeier, C.;
Brandner, W.;
Amorim, A.;
Woillez, J.;
Bonnet, H.
Submitted: 2014-07-16
GRAVITY is a new generation beam combination instrument for the VLTI. Its
goal is to achieve microarsecond astrometric accuracy between objects separated
by a few arcsec. This $10^6$ accuracy on astrometric measurements is the most
important challenge of the instrument, and careful error budget have been
paramount during the technical design of the instrument. In this poster, we
will focus on baselines induced errors, which is part of a larger error budget.
[14]
oai:arXiv.org:1404.1014 [pdf] - 862631
Reaching micro-arcsecond astrometry with long baseline optical
interferometry; application to the GRAVITY instrument
Lacour, S.;
Eisenhauer, F.;
Gillessen, S.;
Pfuhl, O.;
Woillez, J.;
Bonnet, H.;
Perrin, G.;
Lazareff, B.;
Rabien, S.;
Lapeyrere, V.;
Clenet, Y.;
Kervella, P.;
Kok, Y.
Submitted: 2014-04-03, last modified: 2014-05-24
A basic principle of long baseline interferometry is that an optical path
difference (OPD) directly translates into an astrometric measurement. In the
simplest case, the OPD is equal to the scalar product between the vector
linking the two telescopes and the normalized vector pointing toward the star.
However, a too simple interpretation of this scalar product leads to seemingly
conflicting results, called here "the baseline paradox". For micro-arcsecond
accuracy astrometry, we have to model in full the metrology measurement. It
involves a complex system subject to many optical effects: from pure baseline
errors to static, quasi-static and high order optical aberrations. The goal of
this paper is to present the strategy used by the "General Relativity Analysis
via VLT InTerferometrY" instrument (GRAVITY) to minimize the biases introduced
by these defects. It is possible to give an analytical formula on how the
baselines and tip-tilt errors affect the astrometric measurement. This formula
depends on the limit-points of three type of baselines: the wide-angle
baseline, the narrow-angle baseline, and the imaging baseline. We also,
numerically, include non-common path higher-order aberrations, whose amplitude
were measured during technical time at the Very Large Telescope Interferometer.
We end by simulating the influence of high-order common-path aberrations due to
atmospheric residuals calculated from a Monte-Carlo simulation tool for
Adaptive optics systems. The result of this work is an error budget of the
biases caused by the multiple optical imperfections, including optical
dispersion. We show that the beam stabilization through both focal and pupil
tracking is crucial to the GRAVITY system. Assuming the instrument pupil is
stabilized at a 4 cm level on M1, and a field tracking below 0.2$\lambda/D$, we
show that GRAVITY will be able to reach its objective of 10$\mu$as accuracy.
[15]
oai:arXiv.org:1311.7497 [pdf] - 752999
Phase-referenced Interferometry and Narrow-angle Astrometry with SUSI
Submitted: 2013-11-29
The Sydney University Stellar Interferometer (SUSI) now incorporates a new
beam combiner, called the Microarcsecond University of Sydney Companion
Astrometry instrument (MUSCA), for the purpose of high precision differential
astrometry of bright binary stars. Operating in the visible wavelength regime
where photon-counting and post-processing fringe tracking is possible, MUSCA
will be used in tandem with SUSI's primary beam combiner, Precision
Astronomical Visible Observations (PAVO), to record high spatial resolution
fringes and thereby measure the separation of fringe packets of binary stars.
In its current phase of development, the dual beam combiner configuration has
successfully demonstrated for the first time a dual-star phase-referencing
operation in visible wavelengths. This paper describes the beam combiner optics
and hardware, the network of metrology systems employed to measure every
non-common path between the two beam combiners and also reports on a recent
narrow-angle astrometric observation of $\delta$ Orionis A (HR 1852) as the
project enters its on-sky testing phase.
[16]
oai:arXiv.org:1309.3811 [pdf] - 1179234
Long-Baseline Interferometric Multiplicity Survey of the Sco-Cen OB
Association
Rizzuto, A. C.;
Ireland, M. J.;
Robertson, J. G.;
Kok, Y.;
Tuthill, P. G.;
Warrington, B. A.;
Haubois, X.;
Tango, W. J.;
Norris, B.;
Brummelaar, T. ten;
Kraus, A. L.;
Jacob, A.;
Laliberte-Houdeville, C.
Submitted: 2013-09-15
We present the first multiplicity-dedicated long baseline optical
interferometric survey of the Scorpius-Centaurus-Lupus-Crux association. We
used the Sydney University Stellar Interferometer to undertake a survey for new
companions to 58 Sco-Cen B- type stars and have detected 24 companions at
separations ranging from 7-130mas, 14 of which are new detections. Furthermore,
we use a Bayesian analysis and all available information in the literature to
determine the multiplicity distribution of the 58 stars in our sample, showing
that the companion frequency is F = 1.35 and the mass ratio distribution is
best described as a power law with exponent equal to -0.46, agreeing with
previous Sco-Cen high mass work and differing significantly from lower-mass
stars in Tau-Aur. Based on our analysis, we estimate that among young B-type
stars in moving groups, up to 23% are apparently single stars. This has strong
implications for the understanding of high-mass star formation, which requires
angular momentum dispersal through some mechanism such as formation of multiple
systems.
[17]
oai:arXiv.org:1307.7589 [pdf] - 1173031
Searching for solar-like oscillations in the delta Scuti star rho Puppis
Antoci, V.;
Handler, G.;
Grundahl, F.;
Carrier, F.;
Brugamyer, E. J.;
Robertson, P.;
Kjeldsen, H.;
Kok, Y.;
Ireland, M.;
Matthews, J. M.
Submitted: 2013-07-29
Despite the shallow convective envelopes of delta Scuti pulsators, solar-like
oscillations are theoretically predicted to be excited in those stars as well.
To search for such stochastic oscillations we organised a spectroscopic
multi-site campaign for the bright, metal-rich delta Sct star rho Puppis. We
obtained a total of 2763 high-resolution spectra using four telescopes. We
discuss the reduction and analysis with the iodine cell technique, developed
for searching for low-amplitude radial velocity variations, in the presence of
high-amplitude variability. Furthermore, we have determined the angular
diameter of rho Puppis to be 1.68 \pm 0.03 mas, translating into a radius of
3.52 \pm 0.07Rsun. Using this value, the frequency of maximum power of possible
solar-like oscillations, is expected at ~43 \pm 2 c/d (498 \pm 23 muHz). The
dominant delta Scuti-type pulsation mode of rho Puppis is known to be the
radial fundamental mode which allows us to determine the mean density of the
star, and therefore an expected large frequency separation of 2.73 c/d (31.6
muHz). We conclude that 1) the radial velocity amplitudes of the delta Scuti
pulsations are different for different spectral lines; 2) we can exclude
solar-like oscillations to be present in rho Puppis with an amplitude per
radial mode larger than 0.5 m/s.
[18]
oai:arXiv.org:1306.5937 [pdf] - 684435
Optical Interferometry of early-type stars with PAVO@CHARA. I.
Fundamental stellar properties
Maestro, V.;
Che, X.;
Huber, D.;
Ireland, M. J.;
Monnier, J. D.;
White, T. R.;
Kok, Y.;
Robertson, J. G.;
Schaefer, G. H.;
Brummelaar, T. A. Ten;
Tuthill, P. G.
Submitted: 2013-06-25
We present interferometric observations of 7 main-sequence and 3 giant stars
with spectral types from B2 to F6 using the PAVO beam combiner at the CHARA
array. We have directly determined the angular diameters for these objects with
an average precision of 2.3%. We have also computed bolometric fluxes using
available photometry in the visible and infrared wavelengths, as well as
space-based ultraviolet spectroscopy. Combined with precise \textit{Hipparcos}
parallaxes, we have derived a set of fundamental stellar properties including
linear radius, luminosity and effective temperature. Fitting the latter to
computed isochrone models, we have inferred masses and ages of the stars. The
effective temperatures obtained are in good agreement (at a 3% level) with
nearly-independent temperature estimations from spectroscopy. They validate
recent sixth-order polynomial (B-V)-$T_\mathrm{eff}$ empirical relations
\citep{Boyajian2012a}, but suggest that a more conservative third-order
solution \citep{vanBelle2009} could adequately describe the
(V-K)-$T_\mathrm{eff}$ relation for main-sequence stars of spectral type A0 and
later. Finally, we have compared mass values obtained combining surface gravity
with inferred stellar radius (\textit{gravity mass}) and as a result of the
comparison of computed luminosity and temperature values with stellar
evolutionary models (\textit{isochrone mass}). The strong discrepancy between
isochrone and gravity mass obtained for one of the observed stars,
$\gamma$\,Lyr, suggests that determination of the stellar atmosphere parameters
should be revised.
[19]
oai:arXiv.org:1304.0086 [pdf] - 1165626
A low cost scheme for high precision dual-wavelength laser metrology
Submitted: 2013-03-30
A novel method capable of delivering relative optical path length metrology
with nanometer precision is demonstrated. Unlike conventional dual-wavelength
metrology which employs heterodyne detection, the method developed in this work
utilizes direct detection of interference fringes of two He-Ne lasers as well
as a less precise stepper motor open-loop position control system to perform
its measurement. Although the method may be applicable to a variety of
circumstances, the specific application where this metrology is essential is in
an astrometric optical long baseline stellar interferometer dedicated to
precise measurement of stellar positions. In our example application of this
metrology to a narrow-angle astrometric interferometer, measurement of
nanometer precision could be achieved without frequency-stabilized lasers
although the use of such lasers would extend the range of optical path length
the metrology can accurately measure. Implementation of the method requires
very little additional optics or electronics, thus minimizing cost and effort
of implementation. Furthermore, the optical path traversed by the metrology
lasers is identical with that of the starlight or science beams, even down to
using the same photodetectors, thereby minimizing the non-common-path between
metrology and science channels.
[20]
oai:arXiv.org:1303.3658 [pdf] - 1165273
Science and Technology Progress at the Sydney University Stellar
Interferometer
Submitted: 2013-03-14
This paper presents an overview of recent progress at the Sydney University
Stellar Interferometer (SUSI). Development of the third-generation PAVO beam
combiner has continued. The MUSCA beam combiner for high-precision differential
astrometry using visible light phase referencing is under active development
and will be the subject of a separate paper. Because SUSI was one of the
pioneering interferometric instruments, some of its original systems are old
and have become difficult to maintain. We are undertaking a campaign of
modernization of systems: (1) an upgrade of the Optical Path Length Compensator
IR laser metrology counter electronics from a custom system which uses an
obsolete single-board computer to a modern one based on an FPGA interfaced to a
Linux computer - in addition to improving maintainability, this upgrade should
allow smoother motion and higher carriage speeds; (2) the replacement of the
aged single-board computer local controllers for the siderostats and the
longitudinal dispersion compensator has been completed; (3) the large beam
reducing telescope has been replaced with a pair of smaller units with separate
accessible foci. Examples of scientific results are also included.
[21]
oai:arXiv.org:1302.7139 [pdf] - 1164921
Simulating a dual beam combiner at SUSI for narrow-angle astrometry
Submitted: 2013-02-28
The Sydney University Stellar Interferometer (SUSI) has two beam combiners,
i.e. the Precision Astronomical Visible Observations (PAVO) and the
Microarcsecond University of Sydney Companion Astrometry (MUSCA). The primary
beam combiner, PAVO, can be operated independently and is typically used to
measure properties of binary stars of less than 50 milliarc- sec (mas)
separation and the angular diameters of single stars. On the other hand, MUSCA
was recently installed and must be used in tandem with the for- mer. It is
dedicated for microarcsecond precision narrow-angle astrometry of close binary
stars. The performance evaluation and development of the data reduction
pipeline for the new setup was assisted by an in-house computer simulation tool
developed for this and related purposes. This paper describes the framework of
the simulation tool, simulations carried out to evaluate the performance of
each beam combiner and the expected astrometric precision of the dual beam
combiner setup, both at SUSI and possible future sites.