Normalized to: Kohse, G.
[1]
oai:arXiv.org:1109.3501 [pdf] - 1084146
Background Rejection in the DMTPC Dark Matter Search Using Charge
Signals
Lopez, J. P.;
Ahlen, S.;
Battat, J.;
Caldwell, T.;
Chernicoff, M.;
Deaconu, C.;
Dujmic, D.;
Dushkin, A.;
Fedus, W.;
Fisher, P.;
Golub, F.;
Henderson, S.;
Inglis, A.;
Kaboth, A.;
Kohse, G.;
Kirsch, L.;
Lanza, R.;
Lee, A.;
Monroe, J.;
Ouyang, H.;
Sahin, T.;
Sciolla, G.;
Skvorodnev, N.;
Tomita, H.;
Wellenstein, H.;
Wolfe, I.;
Yamamoto, R.;
Yegoryan, H.
Submitted: 2011-09-15
The Dark Matter Time Projection Chamber (DMTPC) collaboration is developing
low-pressure gas TPC detectors for measuring WIMP-nucleon interactions. Optical
readout with CCD cameras allows for the detection for the daily modulation in
the direction of the dark matter wind, while several charge readout channels
allow for the measurement of additional recoil properties. In this article, we
show that the addition of the charge readout analysis to the CCD allows us too
obtain a statistics-limited 90% C.L. upper limit on the $e^-$ rejection factor
of $5.6\times10^{-6}$ for recoils with energies between 40 and 200
keV$_{\mathrm{ee}}$. In addition, requiring coincidence between charge signals
and light in the CCD reduces CCD-specific backgrounds by more than two orders
of magnitude.
[2]
oai:arXiv.org:1012.3912 [pdf] - 280381
DMTPC: Dark matter detection with directional sensitivity
Battat, J. B. R.;
Ahlen, S.;
Caldwell, T.;
Deaconu, C.;
Dujmic, D.;
Fedus, W.;
Fisher, P.;
Golub, F.;
Henderson, S.;
Inglis, A.;
Kaboth, A.;
Kohse, G.;
Lanza, R.;
Lee, A.;
Lopez, J.;
Monroe, J.;
Sahin, T.;
Sciolla, G.;
Skvorodnev, N.;
Tomita, H.;
Wellenstein, H.;
Wolfe, I.;
Yamamoto, R.;
Yegoryan, H.
Submitted: 2010-12-17
The Dark Matter Time Projection Chamber (DMTPC) experiment uses CF_4 gas at
low pressure (0.1 atm) to search for the directional signature of Galactic WIMP
dark matter. We describe the DMTPC apparatus and summarize recent results from
a 35.7 g-day exposure surface run at MIT. After nuclear recoil cuts are applied
to the data, we find 105 candidate events in the energy range 80 - 200 keV,
which is consistent with the expected cosmogenic neutron background. Using this
data, we obtain a limit on the spin-dependent WIMP-proton cross-section of 2.0
\times 10^{-33} cm^2 at a WIMP mass of 115 GeV/c^2. This detector is currently
deployed underground at the Waste Isolation Pilot Plant in New Mexico.
[3]
oai:arXiv.org:1006.2928 [pdf] - 377201
First Dark Matter Search Results from a Surface Run of the 10-L DMTPC
Directional Dark Matter Detector
Ahlen, S.;
Battat, J. B. R.;
Caldwell, T.;
Deaconu, C.;
Dujmic, D.;
Fedus, W.;
Fisher, P.;
Golub, F.;
Henderson, S.;
Inglis, A.;
Kaboth, A.;
Kohse, G.;
Lanza, R.;
Lee, A.;
Lopez, J.;
Monroe, J.;
Sahin, T.;
Sciolla, G.;
Skvorodnev, N.;
Tomita, H.;
Wellenstein, H.;
Wolfe, I.;
Yamamoto, R.;
Yegoryan, H.
Submitted: 2010-06-15, last modified: 2010-12-09
The Dark Matter Time Projection Chamber (DMTPC) is a low pressure (75 Torr
CF4) 10 liter detector capable of measuring the vector direction of nuclear
recoils with the goal of directional dark matter detection. In this paper we
present the first dark matter limit from DMTPC. In an analysis window of 80-200
keV recoil energy, based on a 35.7 g-day exposure, we set a 90% C.L. upper
limit on the spin-dependent WIMP-proton cross section of 2.0 x 10^{-33} cm^{2}
for 115 GeV/c^2 dark matter particle mass.
[4]
oai:arXiv.org:0907.0675 [pdf] - 151008
DMTPC: A dark matter detector with directional sensitivity
Battat, J. B. R.;
Ahlen, S.;
Caldwell, T.;
Dujmic, D.;
Dushkin, A.;
Fisher, P.;
Golub, F.;
Goyal, S.;
Henderson, S.;
Inglis, A.;
Lanza, R.;
Lopez, J.;
Kaboth, A.;
Kohse, G.;
Monroe, J.;
Sciolla, G.;
Skvorodnev, B. N.;
Tomita, H.;
Vanderspek, R.;
Wellenstein, H.;
Yamamoto, R.
Submitted: 2009-07-03
By correlating nuclear recoil directions with the Earth's direction of motion
through the Galaxy, a directional dark matter detector can unambiguously detect
Weakly Interacting Massive Particles (WIMPs), even in the presence of
backgrounds. Here, we describe the Dark Matter Time-Projection Chamber (DMTPC)
detector, a TPC filled with CF4 gas at low pressure (0.1 atm). Using this
detector, we have measured the vector direction (head-tail) of nuclear recoils
down to energies of 100 keV with an angular resolution of <15 degrees. To study
our detector backgrounds, we have operated in a basement laboratory on the MIT
campus for several months. We are currently building a new, high-radiopurity
detector for deployment underground at the Waste Isolation Pilot Plant facility
in New Mexico.
[5]
oai:arXiv.org:0903.3895 [pdf] - 22632
The DMTPC project
Sciolla, G.;
Battat, J.;
Caldwell, T.;
Dujmic, D.;
Fisher, P.;
Henderson, S.;
Lanza, R.;
Lee, A.;
Lopez, J.;
Kaboth, A.;
Kohse, G.;
Monroe, J.;
Sahin, T.;
Sciolla, G.;
Yamamoto, R.;
Yegoryan, H.;
Ahlen, S.;
Otis, K.;
Tomita, H.;
Dushkin, A.;
Wellenstein, H.
Submitted: 2009-03-23
The DMTPC detector is a low-pressure CF4 TPC with optical readout for
directional detection of Dark Matter. The combination of the energy and
directional tracking information allows for an efficient suppression of all
backgrounds. The choice of gas (CF4) makes this detector particularly sensitive
to spin-dependent interactions.
[6]
oai:arXiv.org:0811.2922 [pdf] - 121221
The DMTPC detector
Sciolla, G.;
Battat, J.;
Caldwell, T.;
Cornell, B.;
Dujmic, D.;
Fisher, P.;
Henderson, S.;
Lanza, R.;
Lee, A.;
Lopez, J.;
Kaboth, A.;
Kohse, G.;
Monroe, J.;
Sahin, T.;
Vanderspek, R.;
Yamamoto, R.;
Yegoryan, H.;
Ahlen, S.;
Avery, D.;
Otis, K.;
Roccaro, A.;
Tomita, H.;
Dushkin, A.;
Wellenstein, H.
Submitted: 2008-11-18
Directional detection of Dark Matter allows for unambiguous direct detection
of WIMPs as well as discrimination between various Dark Matter models in our
galaxy. The DMTPC detector is a low-pressure TPC with optical readout designed
for directional direct detection of WIMPs. By using CF4 gas as the active
material, the detector also has excellent sensitivity to spin-dependent
interactions of Dark Matter on protons.
[7]
oai:arXiv.org:0810.0291 [pdf] - 16990
DMTPC: a new apparatus for directional detection of Dark Matter
Sciolla, G.;
Lee, A.;
Battat, J.;
Caldwell, T.;
Cornell, B.;
Dujmic, D.;
Fisher, P.;
Henderson, S.;
Lanza, R.;
Lopez, J.;
Kaboth, A.;
Kohse, G.;
Monroe, J.;
Sahin, T.;
Vanderspek, R .;
Yamamoto, R.;
Yegoryan, H.;
Alhen, S.;
Avery, D.;
Otis, K.;
Roccaro, A.;
Tomita, H.;
Dushkin, A.;
Wellenstein, H.
Submitted: 2008-10-01
Directional detection of Dark Matter allows for unambiguous direct detection
of WIMPs as well as discrimination between various Dark Matter models in our
galaxy. The DMTPC detector is a low-pressure TPC with optical readout designed
for directional direct detection of WIMPs. By using CF4 gas as the active
material, the detector also has excellent sensitivity to spin-dependent
interactions of Dark Matter on protons.
[8]
oai:arXiv.org:0804.4827 [pdf] - 12212
Charge amplification concepts for direction-sensitive dark matter
detectors
Dujmic, D.;
Fisher, P.;
Sciolla, G.;
Ahlen, S.;
Dutta, V.;
Henderson, S.;
Kaboth, A.;
Kohse, G.;
Lanza, R.;
Monroe, J.;
Roccaro, A.;
Skvorodnev, N.;
Tomita, H.;
Vanderspek, R.;
Wellenstein, H.;
Yamamoto, R.
Submitted: 2008-04-30, last modified: 2008-08-22
Direction measurement of weakly interacting massive particles in
time-projection chambers can provide definite evidence of their existence and
help to determine their properties. This article demonstrates several concepts
for charge amplification in time-projection chambers that can be used in
direction-sensitive dark matter search experiments. We demonstrate
reconstruction of the 'head-tail' effect for nuclear recoils above 100keV, and
discuss the detector performance in the context of dark matter detection and
scaling to large detector volumes.
[9]
oai:arXiv.org:0806.2673 [pdf] - 1937507
Toward directional detection of Dark Matter with the DM-TPC detector
Sciolla, G.;
Ahlen, S.;
Dujmic, D.;
Dutta, V.;
Fisher, P.;
Henderson, S.;
Kaboth, A.;
Kohse, G.;
Lanza, R.;
Monroe, J.;
Roccaro, A.;
Skvorodnev, N.;
Tomita, H.;
Vanderspek, R.;
Wellenstein, H.;
Yamamoto, R.
Submitted: 2008-06-16
Directional detection can provide unambiguous observation of Dark Matter
interactions even in presence of insidious backgrounds. The DM-TPC
collaboration is developing a detector with the goal of measuring the direction
and sense of nuclear recoils produced in Dark Matter interactions. The detector
consists of a Time Projection Chamber with optical readout filled with CF$_4$
gas at low pressure. A collision between a WIMP and a gas molecule results in a
nuclear recoil of 1-2 mm. The measurement of the energy loss along the recoil
allows us to determine the sense and the direction of the recoil. Results from
a prototype detector operated in a low-energy neutron beam clearly demonstrate
the suitability of this approach to measure directionality. A cubic meter
prototype, which is now being designed, will allow us to set competitive limits
on spin-dependent Dark Matter interactions using a directional detector.
[10]
oai:arXiv.org:0805.2431 [pdf] - 12694
DM-TPC: a new approach to directional detection of Dark Matter
Sciolla, G.;
Ahlen, S.;
Dujmic, D.;
Dutta, V.;
Fisher, P.;
Henderson, S.;
Kaboth, A.;
Kohse, G.;
Lanza, R.;
Monroe, J.;
Roccaro, A.;
Skvorodnev, N.;
Tomita, H.;
Vanderspek, R.;
Wellenstein, H.;
Yamamoto, R.
Submitted: 2008-05-15
Directional detection can provide unambiguous observation of Dark Matter
interactions even in presence of insidious backgrounds. The DM-TPC
collaboration is developing a detector with the goal of measuring the direction
and sense of nuclear recoils produced in Dark Matter interactions. The detector
consists of a Time Projection Chamber with optical readout filled with CF$_4$
gas at low pressure. A collision between a WIMP and a gas molecule results in a
nuclear recoil of 1-2 mm. The measurement of the energy loss along the recoil
allows us to determine the sense and the direction of the recoil.
Results from a prototype detector operated in a low-energy neutron beam
clearly demonstrate the suitability of this approach to measure directionality.
A full-scale module with an active volume of about one cubic meter is now being
designed. This detector, which will be operated underground in 2009, will allow
us to set competitive limits on spin-dependent Dark Matter interactions using a
directional detector.
[11]
oai:arXiv.org:0801.2687 [pdf] - 9112
Improved measurement of the head-tail effect in nuclear recoils
Dujmic, D.;
Ahlen, S.;
Fisher, P.;
Henderson, S.;
Kaboth, A.;
Kohse, G.;
Lanza, R.;
Lewandowska, M.;
Monroe, J.;
Roccaro, A.;
Sciolla, G.;
Skvorodnev, N.;
Tomita, H.;
Vanderspek, R.;
Wellenstein, H.;
Yamamoto, R.
Submitted: 2008-01-17
We present new results with a prototype detector that is being developed by
the DMTPC collaboration for the measurement of the direction tag (head-tail) of
dark matter wind. We use neutrons from a Cf-252 source to create low-momentum
nuclear recoils in elastic scattering with the residual gas nuclei. The recoil
track is imaged in low-pressure time-projection chamber with optical readout.
We measure the ionization rate along the recoil trajectory, which allows us to
determine the direction tag of the incoming neutrons.
[12]
oai:arXiv.org:0708.2370 [pdf] - 4059
Observation of the 'head-tail' effect in nuclear recoils of low-energy
neutrons
Dujmic, D.;
Tomita, H.;
Lewandowska, M.;
Ahlen, S.;
Fisher, P.;
Henderson, S.;
Kaboth, A.;
Kohse, G.;
Lanza, R.;
Monroe, J.;
Roccaro, A.;
Sciolla, G.;
Skvorodnev, N.;
Vanderspek, R.;
Wellenstein, H.;
Yamamoto, R.
Submitted: 2007-08-17, last modified: 2007-10-09
Directional detection of dark matter can provide unambiguous observation of
dark matter interactions even in the presence of background. This article
presents an experimental method to measure the direction tag ("head-tail") of
the dark matter wind by detecting the scintillation light created by the
elastic nuclear recoils in the scattering of dark matter particles with the
detector material. The technique is demonstrated by tagging the direction of
the nuclear recoils created in the scattering of low-energy neutrons with CF4
in a low-pressure time-projection chamber that is developed by the DMTPC
collaboration. The measurement of the decreasing ionization rate along the
recoil trajectory provides the direction tag of the incoming neutrons, and
proves that the "head-tail" effect can be observed.