Normalized to: Koehler, C.
[1]
oai:arXiv.org:astro-ph/0606329 [pdf] - 1233815
Probing unexplored territories with MUSE: a second generation instrument
for the VLT
Bacon, R.;
Bauer, S.;
Boehm, P.;
Boudon, D.;
Brau-Nogue, S.;
Caillier, P.;
Capoani, L.;
Carollo, C. M.;
Champavert, N.;
Contini, T.;
Daguise, E.;
Dalle, D.;
Delabre, B.;
Devriendt, J.;
Dreizler, S.;
Dubois, J.;
Dupieux, M.;
Dupin, J. P.;
Emsellem, E.;
Ferruit, P.;
Franx, M.;
Gallou, G.;
Gerssen, J.;
Guiderdoni, B.;
Hahn, T.;
Hofmann, D.;
Jarno, A.;
Kelz, A.;
Koehler, C.;
Kollatschny, W.;
Kosmalski, J.;
Laurent, F.;
Lilly, S. J.;
Lizon, J.;
Loupias, M.;
Lynn, S.;
Manescau, A.;
McDermid, R. M.;
Monstein, C.;
Nicklas, H.;
Pares, L.;
Pasquini, L.;
Pecontal-Rousset, A.;
Pecontal, E.;
Pello, R.;
Petit, C.;
Picat, J. -P.;
Popow, E.;
Quirrenbach, A.;
Reiss, R.;
Renault, E.;
Roth, M.;
Schaye, J.;
Soucail, G.;
Steinmetz, M.;
Stroebele, S.;
Stuik, R.;
Weilbacher, P.;
Wozniak, H.;
de Zeeuw, P. T.
Submitted: 2006-06-13
The Multi Unit Spectroscopic Explorer (MUSE) is a second-generation VLT
panoramic integral-field spectrograph under preliminary design study. MUSE has
a field of 1x1 arcmin**2 sampled at 0.2x0.2 arcsec**2 and is assisted by the
VLT ground layer adaptive optics ESO facility using four laser guide stars. The
simultaneous spectral range is 465-930 nm, at a resolution of R~3000. MUSE
couples the discovery potential of a large imaging device to the measuring
capabilities of a high-quality spectrograph, while taking advantage of the
increased spatial resolution provided by adaptive optics. This makes MUSE a
unique and tremendously powerful instrument for discovering and characterizing
objects that lie beyond the reach of even the deepest imaging surveys. MUSE has
also a high spatial resolution mode with 7.5x7.5 arcsec**2 field of view
sampled at 25 milli-arcsec. In this mode MUSE should be able to obtain
diffraction limited data-cubes in the 600-930 nm wavelength range. Although the
MUSE design has been optimized for the study of galaxy formation and evolution,
it has a wide range of possible applications; e.g. monitoring of outer planets
atmosphere, environment of young stellar objects, super massive black holes and
active nuclei in nearby galaxies or massive spectroscopic surveys of stellar
fields in the Milky Way and nearby galaxies.
[2]
oai:arXiv.org:astro-ph/9910443 [pdf] - 108997
On the optimum spacing of stereoscopic imaging atmospheric Cherenkov
telescopes
Submitted: 1999-10-25
For stereoscopic systems of imaging atmospheric Cherenkov telescopes (IACTs),
a key parameter to optimize the sensitivity for VHE gamma-ray point sources is
the intertelescope spacing. Using pairs of telescopes of the HEGRA IACT system,
the sensitivity of two-telescope stereo IACT systems is studied as a function
of the telescope spacing, ranging from 70 m to 140 m. Data taken during the
1997 outburst of Mrk 501 are used to evaluate both the detection rates before
cuts, and the sensitivity for weak signals after cuts to optimize the
significance of signals. Detection rates decrease by about 1/3 between the
minimum and maximum spacing. The significance of signals is essentially
independent of distance, in the range investigated.
[3]
oai:arXiv.org:astro-ph/9801092 [pdf] - 99941
Locating TeV Gamma-Ray Sources with Sub-Arcminute Precision: the
Pointing Calibration of the HEGRA System of Imaging Atmospheric Cherenkov
Telescopes
Submitted: 1998-01-12
Stereoscopic viewing of TeV gamma-ray air showers with systems of Imaging
Atmospheric Cherenkov Telescopes (IACTs) allows to reconstruct the origin of
individual primary particles with an accuracy of 0.1 degree or better. The
shower impact point can be determined within 15 meters. To actually achieve
this resolution, the pointing of the telescopes of an IACT system needs to be
controlled with high precision. For the HEGRA IACT system, a procedure to
calibrate telescope pointing was established, using bright stars distributed
over the sky as references. On the basis of these measurements, one determines
parameters of a correction function which is valid for the complete hemisphere.
After correction a pointing accuracy of 0.01 degree is achieved.
[4]
oai:arXiv.org:astro-ph/9712063 [pdf] - 99552
Characteristics of the Multi-Telescope Coincidence Trigger of the HEGRA
IACT System
Bulian, N.;
Daum, A.;
Hermann, G.;
Hess, M.;
Hofmann, W.;
Lampeitl, H.;
Puehlhofer, G.;
Koehler, C.;
Panter, M.;
Stein, M.;
Boerst, G.;
Rauterberg, G.;
Samorski, M.;
Sauerland, C.;
Stamm, W.
Submitted: 1997-12-04
The HEGRA--collaboration is operating a system of imaging atmospheric
Cherenkov telescopes to search for sources of TeV-gamma-rays. Air showers are
observed in stereoscopic mode with several telescopes simultaneously. To
trigger the telescope system a versatile two-level trigger scheme has been
implemented, which allows a significant reduction of the energy threshold with
respect to single telescopes. The technical implementation of this trigger
scheme and the performance of the trigger system are described. Results include
the dependence of single- and multi-telescope trigger rates on the trigger
thresholds, on the orientation of the telescopes, and on the type of the
primary particle.
[5]
oai:arXiv.org:astro-ph/9707304 [pdf] - 98128
Calibration of the Sensitivity of Imaging Atmospheric Cherenkov
Telescopes using a Reference Light Source
Submitted: 1997-07-28
The sensitivity of an Imaging Atmospheric Cherenkov telescope is calibrated
by shining, from a distant pulsed monochromatic light source, a defined photon
flux onto the mirror. The light pulse is captured and reconstructed by the
telescope in an identical fashion as real Cherenkov light. The intensity of the
calibration light pulse is monitored via a calibrated sensor at the telescope;
in order to account for the lower sensitivity of this sensor compared to the
Cherenkov telescope, an attenuator is inserted in the light source between the
measurements with the calibrated sensor, and with the telescope. The resulting
telescope sensitivities have errors of 10%, and compare well with other
estimates of the sensitivity.