Normalized to: Koechlin, L.
[1]
oai:arXiv.org:1902.06980 [pdf] - 1983818
The solar survey at Pic du Midi: calibrated data and improved images
Submitted: 2019-02-19, last modified: 2019-05-27
At Pic du Midi observatory we carry out a solar survey with images of the
photosphere, prominences and corona. This survey, named CLIMSO (CLIch\'es
Multiples du SOleil), is in the following spectral lines: Fe XIII corona (1.075
micron), H-alpha (656.3 nm) and He I (1.083 micron) prominences, H-alpha and Ca
II (393.4 nm) photosphere. All frames cover 1.3 times the diameter of the Sun
with an angular resolution approaching one arc second. The frame rate is one
per minute per channel (weather permitting) for the prominences and
chromosphere, and one per hour for the Fe XIII corona. This survey started in
2007 for the disk and prominences, and in 2015 for the corona. We have almost
completed one solar cycle, and hope to cover several more, keeping the same
wavelengths or adding others. Aims: Make the CLIMSO images easier to use and
more profitable for the scientific community. Methods: Providing
'science-ready' data. We have improved the contrast capabilities of our
coronagraphs, which now provide images of the Fe XIII corona, in addition to
the previous spectral channels. We have also implemented an autoguiding system
based on a diffractive Fresnel array for precise positioning of the Sun behind
the coronagraphic masks. Results: The data (images and films) are publicly
available and downloadable through virtual observatories and dedicated sites:
e.g. http://climso.irap.omp.eu. For the H-alpha and and Ca II channels we
calibrate the data into physical units, independent of atmospheric or
instrumental conditions: we provide solar maps of spectral radiances inW m^-2
sr^-1 nm^-1. The instrumental improvements and the calibration process are
presented in this paper.
[2]
oai:arXiv.org:1801.00946 [pdf] - 1612068
Improvements on Fresnel arrays for high contrast imaging
Submitted: 2018-01-03
The Fresnel Diffractive Array Imager (FDAI) is based on a new optical concept
for space telescopes, developed at Institut de Recherche en Astrophysique et
Plan\'etologie (IRAP), Toulouse, France. For the visible and near-infrared it
has already proven its performances in resolution and dynamic range. We propose
it now for astrophysical applications in the ultraviolet with apertures from 6
to 30 meters, aimed at imaging in UV faint astrophysical sources close to
bright ones, as well as other applications requiring high dynamic range. Of
course the project needs first a probatory mission at small aperture to
validate the concept in space. In collaboration with institutes in Spain and
Russia, we will propose to board a small prototype of Fresnel imager on the
International Space Station (ISS), with a program combining technical tests and
astrophysical targets. The spectral domain should contain the Lyman-$\alpha$
line ($\lambda= 121$ nm). As part of its preparation, we improve the Fresnel
array design for a better Point Spread Function in UV, presently on a small
laboratory prototype working at 260 nm. Moreover, we plan to validate a new
optical design and chromatic correction adapted to UV. In this article we
present the results of numerical propagations showing the improvement in
dynamic range obtained by combining and adapting three methods : central
obturation, optimization of the bars mesh holding the Fresnel rings, and
orthogonal apodization. We briefly present the proposed astrophysical program
of a probatory mission with such UV optics.
Keywords: Fresnel arrays -- Diffractive optics -- UV imaging -- Apodization
-- High dynamic range -- High angular resolution -- Exoplanets
[3]
oai:arXiv.org:1405.6830 [pdf] - 827372
PISCO2: the new speckle camera of the Nice 76-cm refractor
Submitted: 2014-05-27
We present the new speckle camera PISCO2 made in 2010-2012, for the 76-cm
refractor of C\^ote d'Azur Observatory. It is a focal instrument dedicated to
the observation of visual binary stars using high angular resolution speckle
interferometry techniques to partly overcome the degradation caused by the
atmospheric turbulence. Fitted with an EMCCD detector, PISCO2 allows the
acquisition of short exposure images that are processed in real time by our
specially designed software. Two Risley prisms are used for correcting the
atmospheric dispersion. All optical settings are remotely controlled. We have
already been able to observe faint, close binary stars with angular separations
as small as 0".16, and visual magnitudes of about 16. We also have measured
some particularly difficult systems with a magnitude difference between the two
components of about 4 magnitudes. This level of performance is very promising
for the detection and study of large sets of yet unknown (or partly measured)
binaries with close separation and/or large magnitude difference.
[4]
oai:arXiv.org:0905.1209 [pdf] - 1002158
Fresnel Interferometric Imager: ground-based prototype
Submitted: 2009-05-08
The Fresnel Interferometric Imager is a space-based astronomical telescope
project yielding milli-arc second angular resolution and high contrast images
with loose manufacturing constraints. This optical concept involves diffractive
focusing and formation flying: a first "primary optics" space module holds a
large binary Fresnel Array, and a second "focal module" holds optical elements
and focal instruments that allow for chromatic dispersion correction.
We have designed a reduced-size Fresnel Interferometric Imager prototype and
made optical tests in our lab, in order to validate the concept for future
space missions. The Primary module of this prototype consists of a square, 8 cm
side, 23 m focal length Fresnel array. The focal module is composed of a
diaphragmed small telescope used as "field lens", a small cophased diverging
Fresnel Zone Lens (FZL) that cancels the dispersion and a detector. An
additional module collimates the artificial targets of various shapes, sizes
and dynamic ranges to be imaged.
In this paper, we describe the experimental setup, different designs of the
primary Fresnel array, and the cophased Fresnel Zone Lens that achieves
rigorous chromatic correction. We give quantitative measurements of the
diffraction limited performances and dynamic range on double sources. The tests
have been performed in the visible domain, lambda = 400 - 700 nm.
In addition, we present computer simulations of the prototype optics based on
Fresnel propagation, that corroborate the optical tests. This numerical tool
has been used to simulate the large aperture Fresnel arrays that could be sent
to space with diameters of 3 to 30 m, foreseen to operate from Lyman-alpha (121
nm) to mid I.R. (25 microns).
[5]
oai:arXiv.org:0808.0652 [pdf] - 15162
Fresnel interferometric arrays for space-based imaging: testbed results
Submitted: 2008-08-05, last modified: 2008-08-07
This paper presents the results of a Fresnel Interferometric Array testbed.
This new concept of imager involves diffraction focussing by a thin foil, in
which many thousands of punched subapertures form a pattern related to a
Fresnel zone plate. This kind of array is intended for use in space, as a way
to realizing lightweight large apertures for high angular resolution and high
dynamic range observations. The chromaticity due to diffraction focussing is
corrected by a small diffractive achromatizer placed close to the focal plane
of the array.
The laboratory test results presented here are obtained with an 8 centimeter
side orthogonal array, yielding a 23 meter focal length at 600 nm wavelength.
The primary array and the focal optics have been designed and assembled in our
lab. This system forms an achromatic image. Test targets of various shapes,
sizes, dynamic ranges and intensities have been imaged. We present the first
images, the achieved dynamic range, and the angular resolution.
[6]
oai:arXiv.org:astro-ph/0609817 [pdf] - 1455147
The "PISCO" speckle camera at Pic du Midi Observatory
Submitted: 2006-09-29
We present a new speckle camera designed and built at Observatoire
Midi-Pyr\'{e}n\'{e}es. This focal instrument has been used for four years with
the 2-meter Bernard Lyot Telescope of Pic du Midi observatory. It can be set in
various operating modes: full pupil imaging, masked-pupil imaging,
spectroscopy, wave-front sensor and stellar coronagraphy, hence its name
"PISCO" ("Pupil Interferometry Speckle COronagraph"). Restored images of double
and triple stars have demonstrated its capabilities in providing close to
diffraction limited images (0.06 arcsec in V). PISCO has been fully tested and
is now ready to be used by the whole astronomical community.
[7]
oai:arXiv.org:astro-ph/0510383 [pdf] - 76879
High resolution imaging with Fresnel interferometric arrays: suitability
for exoplanet detection
Submitted: 2005-10-13
We propose a new kind of interferometric array that yields images of high
dynamic range and large field. The numerous individual apertures in this array
form a pattern related to a Fresnel zone plate. This array can be used for
astrophysical imaging over a broad spectral bandwidth spanning from the U.V.
(50 nanometers) to the I.R. (20 microns). Due to the long focal lengths
involved, this instrument requires formation-flying of two space borne vessels.
We present the concept and study the S/N ratio in different situations, then
apply these results to probe the suitability of this concept to detect
exoplanets.