sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Koechlin, Laurent

Normalized to: Koechlin, L.

7 article(s) in total. 16 co-authors, from 1 to 3 common article(s). Median position in authors list is 2,0.

[1]  oai:arXiv.org:1902.06980  [pdf] - 1983818
The solar survey at Pic du Midi: calibrated data and improved images
Comments: 7 pages, 6 figures, 1 table, submitted to A&A
Submitted: 2019-02-19, last modified: 2019-05-27
At Pic du Midi observatory we carry out a solar survey with images of the photosphere, prominences and corona. This survey, named CLIMSO (CLIch\'es Multiples du SOleil), is in the following spectral lines: Fe XIII corona (1.075 micron), H-alpha (656.3 nm) and He I (1.083 micron) prominences, H-alpha and Ca II (393.4 nm) photosphere. All frames cover 1.3 times the diameter of the Sun with an angular resolution approaching one arc second. The frame rate is one per minute per channel (weather permitting) for the prominences and chromosphere, and one per hour for the Fe XIII corona. This survey started in 2007 for the disk and prominences, and in 2015 for the corona. We have almost completed one solar cycle, and hope to cover several more, keeping the same wavelengths or adding others. Aims: Make the CLIMSO images easier to use and more profitable for the scientific community. Methods: Providing 'science-ready' data. We have improved the contrast capabilities of our coronagraphs, which now provide images of the Fe XIII corona, in addition to the previous spectral channels. We have also implemented an autoguiding system based on a diffractive Fresnel array for precise positioning of the Sun behind the coronagraphic masks. Results: The data (images and films) are publicly available and downloadable through virtual observatories and dedicated sites: e.g. http://climso.irap.omp.eu. For the H-alpha and and Ca II channels we calibrate the data into physical units, independent of atmospheric or instrumental conditions: we provide solar maps of spectral radiances inW m^-2 sr^-1 nm^-1. The instrumental improvements and the calibration process are presented in this paper.
[2]  oai:arXiv.org:1801.00946  [pdf] - 1612068
Improvements on Fresnel arrays for high contrast imaging
Comments: 22 pages, 12 figures
Submitted: 2018-01-03
The Fresnel Diffractive Array Imager (FDAI) is based on a new optical concept for space telescopes, developed at Institut de Recherche en Astrophysique et Plan\'etologie (IRAP), Toulouse, France. For the visible and near-infrared it has already proven its performances in resolution and dynamic range. We propose it now for astrophysical applications in the ultraviolet with apertures from 6 to 30 meters, aimed at imaging in UV faint astrophysical sources close to bright ones, as well as other applications requiring high dynamic range. Of course the project needs first a probatory mission at small aperture to validate the concept in space. In collaboration with institutes in Spain and Russia, we will propose to board a small prototype of Fresnel imager on the International Space Station (ISS), with a program combining technical tests and astrophysical targets. The spectral domain should contain the Lyman-$\alpha$ line ($\lambda= 121$ nm). As part of its preparation, we improve the Fresnel array design for a better Point Spread Function in UV, presently on a small laboratory prototype working at 260 nm. Moreover, we plan to validate a new optical design and chromatic correction adapted to UV. In this article we present the results of numerical propagations showing the improvement in dynamic range obtained by combining and adapting three methods : central obturation, optimization of the bars mesh holding the Fresnel rings, and orthogonal apodization. We briefly present the proposed astrophysical program of a probatory mission with such UV optics. Keywords: Fresnel arrays -- Diffractive optics -- UV imaging -- Apodization -- High dynamic range -- High angular resolution -- Exoplanets
[3]  oai:arXiv.org:1405.6830  [pdf] - 827372
PISCO2: the new speckle camera of the Nice 76-cm refractor
Comments: 13 pages, 12 figures
Submitted: 2014-05-27
We present the new speckle camera PISCO2 made in 2010-2012, for the 76-cm refractor of C\^ote d'Azur Observatory. It is a focal instrument dedicated to the observation of visual binary stars using high angular resolution speckle interferometry techniques to partly overcome the degradation caused by the atmospheric turbulence. Fitted with an EMCCD detector, PISCO2 allows the acquisition of short exposure images that are processed in real time by our specially designed software. Two Risley prisms are used for correcting the atmospheric dispersion. All optical settings are remotely controlled. We have already been able to observe faint, close binary stars with angular separations as small as 0".16, and visual magnitudes of about 16. We also have measured some particularly difficult systems with a magnitude difference between the two components of about 4 magnitudes. This level of performance is very promising for the detection and study of large sets of yet unknown (or partly measured) binaries with close separation and/or large magnitude difference.
[4]  oai:arXiv.org:0905.1209  [pdf] - 1002158
Fresnel Interferometric Imager: ground-based prototype
Comments: 10 pages, 13 figures; accepted for publication in Applied Optics
Submitted: 2009-05-08
The Fresnel Interferometric Imager is a space-based astronomical telescope project yielding milli-arc second angular resolution and high contrast images with loose manufacturing constraints. This optical concept involves diffractive focusing and formation flying: a first "primary optics" space module holds a large binary Fresnel Array, and a second "focal module" holds optical elements and focal instruments that allow for chromatic dispersion correction. We have designed a reduced-size Fresnel Interferometric Imager prototype and made optical tests in our lab, in order to validate the concept for future space missions. The Primary module of this prototype consists of a square, 8 cm side, 23 m focal length Fresnel array. The focal module is composed of a diaphragmed small telescope used as "field lens", a small cophased diverging Fresnel Zone Lens (FZL) that cancels the dispersion and a detector. An additional module collimates the artificial targets of various shapes, sizes and dynamic ranges to be imaged. In this paper, we describe the experimental setup, different designs of the primary Fresnel array, and the cophased Fresnel Zone Lens that achieves rigorous chromatic correction. We give quantitative measurements of the diffraction limited performances and dynamic range on double sources. The tests have been performed in the visible domain, lambda = 400 - 700 nm. In addition, we present computer simulations of the prototype optics based on Fresnel propagation, that corroborate the optical tests. This numerical tool has been used to simulate the large aperture Fresnel arrays that could be sent to space with diameters of 3 to 30 m, foreseen to operate from Lyman-alpha (121 nm) to mid I.R. (25 microns).
[5]  oai:arXiv.org:0808.0652  [pdf] - 15162
Fresnel interferometric arrays for space-based imaging: testbed results
Comments: 7 pages, 8 figures; to be published as ref.6687-16 in SPIE Proceedings vol. 6687: UV/Optical/IR Space Telescopes: Innovative Technologies and Concepts III, Howard A. MacEwen; James B. Breckinridge, Editors
Submitted: 2008-08-05, last modified: 2008-08-07
This paper presents the results of a Fresnel Interferometric Array testbed. This new concept of imager involves diffraction focussing by a thin foil, in which many thousands of punched subapertures form a pattern related to a Fresnel zone plate. This kind of array is intended for use in space, as a way to realizing lightweight large apertures for high angular resolution and high dynamic range observations. The chromaticity due to diffraction focussing is corrected by a small diffractive achromatizer placed close to the focal plane of the array. The laboratory test results presented here are obtained with an 8 centimeter side orthogonal array, yielding a 23 meter focal length at 600 nm wavelength. The primary array and the focal optics have been designed and assembled in our lab. This system forms an achromatic image. Test targets of various shapes, sizes, dynamic ranges and intensities have been imaged. We present the first images, the achieved dynamic range, and the angular resolution.
[6]  oai:arXiv.org:astro-ph/0609817  [pdf] - 1455147
The "PISCO" speckle camera at Pic du Midi Observatory
Comments:
Submitted: 2006-09-29
We present a new speckle camera designed and built at Observatoire Midi-Pyr\'{e}n\'{e}es. This focal instrument has been used for four years with the 2-meter Bernard Lyot Telescope of Pic du Midi observatory. It can be set in various operating modes: full pupil imaging, masked-pupil imaging, spectroscopy, wave-front sensor and stellar coronagraphy, hence its name "PISCO" ("Pupil Interferometry Speckle COronagraph"). Restored images of double and triple stars have demonstrated its capabilities in providing close to diffraction limited images (0.06 arcsec in V). PISCO has been fully tested and is now ready to be used by the whole astronomical community.
[7]  oai:arXiv.org:astro-ph/0510383  [pdf] - 76879
High resolution imaging with Fresnel interferometric arrays: suitability for exoplanet detection
Comments: 12 pages, 19 figures, to be published in A&A
Submitted: 2005-10-13
We propose a new kind of interferometric array that yields images of high dynamic range and large field. The numerous individual apertures in this array form a pattern related to a Fresnel zone plate. This array can be used for astrophysical imaging over a broad spectral bandwidth spanning from the U.V. (50 nanometers) to the I.R. (20 microns). Due to the long focal lengths involved, this instrument requires formation-flying of two space borne vessels. We present the concept and study the S/N ratio in different situations, then apply these results to probe the suitability of this concept to detect exoplanets.