sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Knight, Haydon S.

Normalized to: Knight, H.

7 article(s) in total. 22 co-authors, from 1 to 5 common article(s). Median position in authors list is 3,0.

[1]  oai:arXiv.org:0801.0334  [pdf] - 8584
Bright Giant Pulses from the Crab Nebula Pulsar: Statistical Properties, Pulse Broadening and Scattering due to the Nebula
Comments: 8 pages, 8 figures, Accepted for publication in ApJ
Submitted: 2008-01-01
We report observations of Crab giant pulses made with the Australia Telescope Compact Array and a baseband recorder system, made simultaneously at two frequencies, 1300 and 1470 MHz. These observations were sensitive to pulses with amplitudes \ga 3 kJy and widths \ga 0.5 $\mu$s. Our analysis led to the detection of more than 700 such bright giant pulses over 3 hours, and using this large sample we investigate their amplitude, width, arrival time and energy distributions. The brightest pulse detected in our data has a peak amplitude of $\sim$ 45 kJy and a width of $\sim$ 0.5 $\mu$s, and therefore an inferred brightness temperature of $\sim 10^{35}$ K. The duration of giant-pulse emission is typically $\sim$1 $\mu$s, however it can also be as long as 10 $\mu$s. The pulse shape at a high time resolution (128 ns) shows rich diversity and complexity in structure and is marked by an unusually low degree of scattering. We discuss possible implications for scattering due to the nebula, and for underlying structures and electron densities.
[2]  oai:arXiv.org:0705.0404  [pdf] - 958
Detection of Crab Giant Pulses Using the Mileura Widefield Array Low Frequency Demonstrator Field Prototype System
Comments: 10 pages, 6 figures, Accepted for publication in the Astrophysical Journal
Submitted: 2007-05-02
We report on the detection of giant pulses from the Crab Nebula pulsar at a frequency of 200 MHz using the field deployment system designed for the Mileura Widefield Array's Low Frequency Demonstrator (MWA-LFD). Our observations are among the first high-quality detections at such low frequencies. The measured pulse shapes are deconvolved for interstellar pulse broadening, yielding a pulse-broadening time of 670$\pm$100 $\mu$s, and the implied strength of scattering (scattering measure) is the lowest that is estimated towards the Crab nebula from observations made so far. The sensitivity of the system is largely dictated by the sky background, and our simple equipment is capable of detecting pulses that are brighter than $\sim$9 kJy in amplitude. The brightest giant pulse detected in our data has a peak amplitude of $\sim$50 kJy, and the implied brightness temperature is $10^{31.6}$ K. We discuss the giant pulse detection prospects with the full MWA-LFD system. With a sensitivity over two orders of magnitude larger than the prototype equipment, the full system will be capable of detecting such bright giant pulses out to a wide range of Galactic distances; from $\sim$8 to $\sim$30 kpc depending on the frequency. The MWA-LFD will thus be a highly promising instrument for the studies of giant pulses and other fast radio transients at low frequencies.
[3]  oai:arXiv.org:astro-ph/0609448  [pdf] - 85040
Discovery of Five Recycled Pulsars in a High Galactic Latitude Survey
Comments: 15 pages, 3 figures, accepted for publication in ApJ
Submitted: 2006-09-15
We present five recycled pulsars discovered during a 21-cm survey of approximately 4,150 deg^2 between 15 deg and 30 deg from the galactic plane using the Parkes radio telescope. One new pulsar, PSR J1528-3146, has a 61 ms spin period and a massive white dwarf companion. Like many recycled pulsars with heavy companions, the orbital eccentricity is relatively high (~0.0002), consistent with evolutionary models that predict less time for circularization. The four remaining pulsars have short spin periods (3 ms < P < 6 ms); three of these have probable white dwarf binary companions and one (PSR J2010-1323) is isolated. PSR J1600-3053 is relatively bright for its dispersion measure of 52.3 pc cm^-3 and promises good timing precision thanks to an intrinsically narrow feature in its pulse profile, resolvable through coherent dedispersion. In this survey, the recycled pulsar discovery rate was one per four days of telescope time or one per 600 deg^2 of sky. The variability of these sources implies that there are more millisecond pulsars that might be found by repeating this survey.
[4]  oai:arXiv.org:astro-ph/0608155  [pdf] - 84032
A Study of Giant Pulses from PSR J1824-2452A
Comments: Accepted by ApJ
Submitted: 2006-08-07
We have searched for microsecond bursts of emission from millisecond pulsars in the globular cluster M28 using the Parkes radio telescope. We detected a total of 27 giant pulses from the known emitter PSR J1824-2452A. At wavelengths around 20 cm the giant pulses are scatter-broadened to widths of around 2 microseconds and follow power-law statistics. The pulses occur in two narrow phase-windows which correlate in phase with X-ray emission and trail the peaks of the integrated radio pulse-components. Notably, the integrated radio emission at these phase windows has a steeper spectral index than other emission. The giant pulses exhibit a high degree of polarization, with many being 100% elliptically polarized. Their position angles appear random. Although the integrated emission of PSR J1824-2452A is relatively stable for the frequencies and bandwidths observed, the intensities of individual giant pulses vary considerably across our bands. Two pulses were detected at both 2700 and 3500 MHz. The narrower of the two pulses is 20 ns wide at 3500 MHz. At 2700 MHz this pulse has an inferred brightness temperature at maximum of 5 x 10^37 K. Our observations suggest the giant pulses of PSR J1824-2452A are generated in the same part of the magnetosphere as X-ray emission through a different emission process to that of ordinary pulses.
[5]  oai:arXiv.org:astro-ph/0512341  [pdf] - 78541
Green Bank Telescope Studies of Giant Pulses from Millisecond Pulsars
Comments: 26 pages, 4 figures, accepted to ApJ
Submitted: 2005-12-13
We have conducted a search for giant pulses from four millisecond pulsars using the 100m Green Bank Telescope. Coherently dedispersed time-series from PSR J0218+4232 were found to contain giant pulses of very short intrinsic duration whose energies follow power-law statistics. The giant pulses are in phase with the two minima of the radio integrated pulse profile but are phase aligned with the peaks of the X-ray profile. Historically, individual pulses more than 10-20 times the mean pulse energy have been deemed to be ``giant pulses''. As only 4 of the 155 pulses had energies greater than 10 times the mean pulse-energy, we argue the emission mechanism responsible for giant pulses should instead be defined through: (a) intrinsic timescales of microsecond or nanosecond duration; (b) power-law energy statistics; and (c) emission occurring in narrow phase-windows coincident with the phase windows of non-thermal X-ray emission. Four short-duration pulses with giant-pulse characteristics were also observed from PSR B1957+20. As the inferred magnetic fields at the light cylinders of the millisecond pulsars that emit giant pulses are all very high, this parameter has previously been considered to be an indicator of giant pulse emissivity. However, the frequency of giant pulse emission from PSR~B1957+20 is significantly lower than for other millisecond pulsars that have similar magnetic fields at their light cylinders. This suggests that the inferred magnetic field at the light cylinder is a poor indicator of the rate of emission of giant pulses.
[6]  oai:arXiv.org:astro-ph/0502203  [pdf] - 70994
A Search for Giant Pulses from Millisecond Pulsars
Comments: 14 pages, 2 figures, accepted for publication in ApJ
Submitted: 2005-02-09
We have searched for microsecond-timescale broadband emission from a sample of eighteen millisecond pulsars. Our study places strong limits on such emission from several millisecond pulsars and shows that it is only present in a small subset of millisecond pulsars. Giant pulses of up to 64 times the mean pulse energy were detected from PSR J1823-3021A in the globular cluster NGC 6624. In contrast to the giant pulses of PSR B1937+21, nearly all of the giant pulses from PSR J1823-3021A were distributed within the trailing half of the main-pulse component of the integrated pulse profile. The fact that no giant pulses were observed on the leading side of the main-pulse component suggests that giant pulses are preferentially emitted closer to the last open field line than ordinary emission. The correlation between giant pulse emissivity and spin-down luminosity in millisecond pulsars suggests that the high period derivative of PSR J1823-3021A is intrinsic and is not just an artifact of its acceleration in the gravitational potential of NGC 6624.
[7]  oai:arXiv.org:astro-ph/0307468  [pdf] - 58181
Self-consistency of relativistic observables with general relativity in the white dwarf-neutron star binary pulsar PSR J1141-6545
Comments: 10 pages, 2 figures, revised version to Ap J Letters
Submitted: 2003-07-27
Here we report timing measurements of the relativistic binary pulsar PSR J1141-6545 that constrain the component masses and demonstrate that the orbital period derivative \dot Pb = (-4+/-1)x10^-13 is consistent with gravitational wave emission as described by the general theory of relativity. The mass of the neutron star and its companion are 1.30+/-0.02 Mo and 0.986+/-0.020 Mo respectively, suggesting a white dwarf companion, and extending the range of systems for which general relativity provides a correct description. On evolutionary grounds, the progenitor mass of PSR J1141-6545 should be near the minimum for neutron star production. Its mass is two standard deviations below the mean of the other neutron stars, suggesting a relationship between progenitor and remnant masses.