Multi-wavelength Calibration Procedure for the Pierre Auger Observatory
Fluorescence Detectors
Submitted: 2008-11-10, last modified: 2009-02-12
We present a method to measure the relative spectral response of the Pierre
Auger Observatory Fluorescence Detector. The calibration was done at
wavelengths of 320, 337, 355, 380 and 405 nm using an end-to-end technique in
which the response of all detector components are combined in a single
measurement. A xenon flasher and notch-filters were used as the light source
for the calibration device. The overall uncertainty is 5%.
[10]
oai:arXiv.org:0708.1924 [pdf] - 1934159
The Absolute, Relative and Multi-Wavelength Calibration of the Pierre
Auger Observatory Fluorescence Detectors
Knapik, R.;
Bauleo, P.;
Becker, B. R.;
Brack, J.;
Caruso, R.;
Fratte, C. Delle;
Dorofeev, A.;
Harton, J.;
Insolia, A.;
Matthews, J. A. J.;
Menshikov, A.;
Ortolani, F.;
Petrinca, P.;
Pichel, A.;
Riggi, S.;
Roberts, M.;
Martino, J. Rodriguez;
Rovero, A. C.;
Scuderi, M.;
Tamashiro, A.;
Torresi, D.;
Tuci, V.;
Wiencke, L.
Submitted: 2007-08-14
Absolute calibration of the Pierre Auger Observatory fluorescence detectors
uses a 375 nm light source at the telescope aperture. This end-to-end technique
accounts for the combined effects of all detector components in a single
measurement. The relative response has been measured at wavelengths of 320,
337, 355, 380 and 405 nm, defining a spectral response curve which has been
normalized to the absolute calibration. Before and after each night of data
taking a relative calibration of the phototubes is performed. This relative
calibration is used to track both short and long term changes in the detector's
response. A cross check of the calibration in some phototubes is performed
using an independent laser technique. Overall uncertainties, current results
and future plans are discussed.
[11]
oai:arXiv.org:astro-ph/0510320 [pdf] - 76816
The trigger system of the Pierre Auger Surface Detector: operation,
efficiency and stability
Allard, D.;
Armengaud, E.;
Allekotte, I.;
Allison, P.;
Aublin, J.;
Ave, M.;
Bauleo, P.;
Beatty, J.;
Beau, T.;
Bertou, X.;
Billoir, P.;
Bonifazi, C.;
Chou, A.;
Chye, J.;
Dagoret-Campagne, S.;
Dorofeev, A.;
Ghia, P. L.;
Berisso, M. Gomez;
Gorgi, A.;
Hamilton, J. C.;
Harton, J.;
Knapik, R.;
Lachaud, C.;
Lhenry-Yvon, I.;
Letessier-Selvon, A.;
Matthews, J.;
Medina, C.;
Meyhandan, R.;
Navarra, G.;
Nitz, D.;
Parizot, E.;
Revenu, B.;
Szadkowski, Z.;
Yamamoto, T.
Submitted: 2005-10-11
The trigger system of the Surface Detector (SD) of the Pierre Auger
Observatory is described, from the identification of candidate showers ($E>1$
EeV) at the level of a single station, among a huge background (mainly single
muons), up to the selection of real events and the rejection of random
coincidences at a higher central trigger level (including the reconstruction
accuracy). Efficiency of a single station trigger is evaluated using real data
, and the high performance of event selection hierarchy will be demonstrated.
[12]
oai:arXiv.org:astro-ph/0507577 [pdf] - 74746
Optical Relative Calibration and Stability Monitoring for the Auger
Fluorescence Detector
Pierre Auger Collaboration;
Aramo, C.;
Brack, J.;
Caruso, R.;
D'Urso, D.;
Fazio, D.;
Fonte, R.;
Gemmeke, H.;
Kleifges, M.;
Knapik, R.;
Insolia, A.;
Matthews, J. A. J.;
Menshikov, A.;
Miller, W.;
Privitera, P.;
Martino, J. Rodriguez
Submitted: 2005-07-25, last modified: 2005-07-26
The stability of the fluorescence telescopes of the Pierre Auger Observatory
is monitored with the optical relative calibration setup. Optical fibers
distribute light pulses to three different diffuser groups within the optical
system. The total charge per pulse is measured for each pixel and compared with
reference calibration measurements. This allows monitoring the short and long
term stability with respect of the relative timing between pixels and the
relative gain for each pixel. The designs of the LED calibration unit (LCU) and
of the Xenon flash lamp used for relative calibration, are described and their
capabilities to monitor the stability of the telescope performances are
studied. We report the analysis of relative calibration data recorded during
2004. Fluctuations in the relative calibration constants provide a measure of
the stability of the FD.
[13]
oai:arXiv.org:astro-ph/0507590 [pdf] - 1938930
Measurement of the Lateral Distribution Function of UHECR Air Showers
with the Pierre Auger Observatory
Barnhill, D.;
Bauleo, P.;
Dova, M. T.;
Harton, J.;
Knapik, R.;
Knapp, J.;
Lee, J.;
Mancenido, M.;
Mariazzi, A. G.;
Maris, I. C.;
Newton, D.;
Roth, M.;
Schmidt, T.;
Watson, AA
Submitted: 2005-07-25
The Pierre Auger Observatory is being used to study cosmic rays with energies
larger than 10 EeV. An essential quantity that must be deduced from data is the
lateral distribution function (LDF). Knowledge of the LDF is important for the
reconstruction of the shower core and the shower direction. Here we describe
how the LDF is measured using the large sample of events recorded with the
surface detector (SD) array and with a small sample observed with the
fluorescence detectors (FD). For hybrid events, in which SD and FD measurements
of the same shower are available, the core position is much better constrained
than for SD-only events, thus providing an important cross-check on the LDF
determined from SD measurements alone.
[14]
oai:arXiv.org:astro-ph/0507347 [pdf] - 1938912
Absolute Calibration of the Auger Fluorescence Detectors
Submitted: 2005-07-14
Absolute calibration of the Pierre Auger Observatory fluorescence detectors
uses a light source at the telescope aperture. The technique accounts for the
ombined effects of all detector components in a single measurement. The
calibrated 2.5 m diameter light source fills the aperture, providing uniform
illumination to each pixel. The known flux from the light source and the
response of the acquisition system give the required calibration for each
pixel. In the lab, light source uniformity is studied using CCD images and the
intensity is measured relative to NIST-calibrated photodiodes. Overall
uncertainties are presently 12%, and are dominated by systematics.