sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Knötig, Max

Normalized to: Knötig, M.

2 article(s) in total. 37 co-authors. Median position in authors list is 7,5.

[1]  oai:arXiv.org:1311.0478  [pdf] - 741502
FACT - Long-term Monitoring of Bright TeV-Blazars
Comments: 4 pages, 4 figures, presented at the 33rd ICRC (2013)
Submitted: 2013-11-03
Since October 2011, the First G-APD Cherenkov Telescope (FACT) is operated successfully on the Canary Island of La Palma. Apart from the proof of principle for the use of G-APDs in Cherenkov telescopes, the major goal of the project is the dedicated long-term monitoring of a small sample of bright TeV blazars. The unique properties of G-APDs permit stable observations also during strong moon light. Thus a superior sampling density is provided on time scales at which the blazar variability amplitudes are expected to be largest, as exemplified by the spectacular variations of Mrk 501 observed in June 2012. While still in commissioning, FACT monitored bright blazars like Mrk 421 and Mrk 501 during the past 1.5 years so far. Preliminary results including the Mrk 501 flare from June 2012 will be presented.
[2]  oai:arXiv.org:1307.5463  [pdf] - 1937903
Novel Photo Multiplier Tubes for the Cherenkov Telescope Array Project
Comments: In Proceedings of the 33rd International Cosmic Ray Conference (ICRC2013), Rio de Janeiro (Brazil). All CTA contributions at arXiv:1307.2232
Submitted: 2013-07-20
Currently the standard light sensors for imaging atmospheric Cherenkov telescopes are the classical photo multiplier tubes that are using bialkali photo cathodes. About eight years ago we initiated an improvement program with the Photo Multiplier Tube (PMT) manufacturers Hamamatsu (Japan), Electron Tubes Enterprises (England) and Photonis (France) for the needs of imaging atmospheric Cherenkov telescopes. As a result, after about 40 years of stagnation of the peak Quantum Efficiency (QE) on the level of 25-27%, new PMTs appeared with a peak QE of 35%. These have got the name super-bialkali. The second significant upgrade has happened very recently, as a result of a dedicated improvement program for the candidate PMT for Cherenkov Telescope Array. The latter is going to be the next generation major instrument in the field of very high energy gamma astrophysics and will consist of over 100 telescopes of three different sizes of 23m, 12m and 4-7m, located both in southern and northern hemispheres. Now PMTs with average peak QE of approximately 40% became available. Also, the photo electron collection efficiency of the previous generation PMTs of 80- 90% has been enhanced towards 95-98% for the new ones. The after-pulsing of novel PMTs has been reduced towards the level of 0.02% for the set threshold of 4 photo electrons. We will report on the PMT development work by the companies Electron Tubes Enterprises and Hamamatsu Photonics K.K. show the achieved results and the current status.