Normalized to: Kluck, H.
[1]
oai:arXiv.org:2005.02692 [pdf] - 2090731
Cryogenic characterization of a LiAlO$_{2}$ crystal and new results on
spin-dependent dark matter interactions with ordinary matter
Abdelhameed, A. H.;
Angloher, G.;
Bauer, P.;
Bento, A.;
Bertoldo, E.;
Breier, R.;
Bucci, C.;
Canonica, L.;
D'Addabbo, A.;
Di Lorenzo, S.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Fichtinger, S.;
Fuchs, D.;
Fuss, A.;
Ghete, V. M.;
Garai, A.;
Gorla, P.;
Hauff, D.;
Ješkovský, M.;
Jochum, J.;
Kaizer, J.;
Kaznacheeva, M.;
Kinast, A.;
Kluck, H.;
Kraus, H.;
Langenkämper, A.;
Mancuso, M.;
Mokina, V.;
Mondragon, E.;
Olmi, M.;
Ortmann, T.;
Pagliarone, C.;
Palušová, V.;
Pattavina, L.;
Petricca, F.;
Potzel, W.;
Povinec, P.;
Pröbst, F.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schipperges, V.;
Schmiedmayer, D.;
Schönert, S.;
Schwertner, C.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Usherov, I.;
Wagner, F.;
Willers, M.;
Zema, V.;
Zeman, J.;
Brützam, M.;
Ganschow, S.
Submitted: 2020-05-06
In this work, a first cryogenic characterization of a scintillating
LiAlO$_{2}$ single crystal is presented. The results achieved show that this
material holds great potential as a target for direct dark matter search
experiments. Three different detector modules obtained from one crystal grown
at the Leibniz-Institut f\"ur Kristallz\"uchtung (IKZ) have been tested to
study different properties at cryogenic temperatures. Firstly, two 2.8 g twin
crystals were used to build different detector modules which were operated in
an above-ground laboratory at the Max Planck Institute for Physics (MPP) in
Munich, Germany. The first detector module was used to study the scintillation
properties of LiAlO$_{2}$ at cryogenic temperatures. The second achieved an
energy threshold of (213.02$\pm$1.48) eV which allows setting a competitive
limit on the spin-dependent dark matter particle-proton scattering cross
section for dark matter particle masses between 350 MeV/c$^{2}$ and 1.50
GeV/c$^{2}$. Secondly, a detector module with a 373 g LiAlO$_{2}$ crystal as
the main absorber was tested in an underground facility at the Laboratori
Nazionali del Gran Sasso (LNGS): from this measurement it was possible to
determine the radiopurity of the crystal and study the feasibility of using
this material as a neutron flux monitor for low-background experiments.
[2]
oai:arXiv.org:1905.07335 [pdf] - 2075555
Description of CRESST-III Data
CRESST Collaboration;
Abdelhameed, A. H.;
Angloher, G.;
Bauer, P.;
Bento, A.;
Bertoldo, E.;
Bucci, C.;
Canonica, L.;
D'Addabbo, A.;
Defay, X.;
Di Lorenzo, S.;
Erb, A.;
Feilitzsch, F. v.;
Fichtinger, S.;
Iachellini, N. Ferreiro;
Fuss, A.;
Gorla, P.;
Hauff, D.;
Jochum, J.;
Kinast, A.;
Kluck, H.;
Kraus, H.;
Langenkämper, A.;
Mancuso, M.;
Mokina, V.;
Mondragon, E.;
Münster, A.;
Olmi, M.;
Ortmann, T.;
Pagliarone, C.;
Pattavina, L.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schipperges, V.;
Schmiedmayer, D.;
Schönert, S.;
Schwertner, C.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Türkoglu, C.;
Usherov, I.;
Willers, M.;
Zema, V.
Submitted: 2019-05-17, last modified: 2020-04-06
In CRESST-III, 10 cryogenic detector modules optimized for low energy
thresholds were operated for almost two years (May 2016 - February 2018).
Together with this document we are publishing data from the best performing
detector module which has a nuclear recoil threshold of 30.1eV. With this
data-set we were able to set limits on the cross-section for spin-dependent and
spin-independent elastic scattering of dark matter particles off nuclei at dark
matter masses down to 160MeV/c$^2$. We publish the energies of all events after
data selection as well as of all events within the acceptance region for
dark-matter searches. In this document we describe how to use these data sets.
[3]
oai:arXiv.org:1902.07587 [pdf] - 2045154
First results on sub-GeV spin-dependent dark matter interactions with
$^{7}$Li
Abdelhameed, A. H.;
Angloher, G.;
Bauer, P.;
Bento, A.;
Bertoldo, E.;
Bucci, C.;
Canonica, L.;
D'Addabbo, A.;
Defay, X.;
Di Lorenzo, S.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Fichtinger, S.;
Fuss, A.;
Gorla, P.;
Hauff, D.;
Jochum, J.;
Kinast, A.;
Kluck, H.;
Kraus, H.;
Langenkämper, A.;
Mancuso, M.;
Mokina, V.;
Mondragon, E.;
Münster, A.;
Olmi, M.;
Ortmann, T.;
Pagliarone, C.;
Pattavina, L.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schipperges, V.;
Schmiedmayer, D.;
Schönert, S.;
Schwertner, C.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Türkoglu, C.;
Usherov, I.;
Willers, M.;
Zema, V.;
Chapellier, M.;
Giuliani, A.;
Nones, C.;
Poda, D. V.;
Shlegel, V. N.;
Velázquez, M.;
Zolotarova, A. S.
Submitted: 2019-02-20, last modified: 2019-09-04
In this work, we want to highlight the potential of lithium as a target for
spin-dependent dark matter search in cryogenic experiments, with a special
focus on the low-mass region of the parameter space. We operated a prototype
detector module based on a Li$_2$MoO$_4$ target crystal in an above-ground
laboratory. Despite the high background environment, the detector sets
competitive limits on spin-dependent interactions of dark matter particles with
protons and neutrons for masses between 0.8 GeV/c$^2$ and 1.5 GeV/c$^2$.
[4]
oai:arXiv.org:1908.06755 [pdf] - 2001880
Geant4-based electromagnetic background model for the CRESST dark matter
experiment
CRESST Collaboration;
Abdelhameed, A. H.;
Angloher, G.;
Bauer, P.;
Bento, A.;
Bertoldo, E.;
Breier, R.;
Bucci, C.;
Canonica, L.;
D'Addabbo, A.;
Di Lorenzo, S.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Fichtinger, S.;
Fuss, A.;
Gorla, P.;
Hauff, D.;
Ješkovský, M.;
Jochum, J.;
Kaizer, J.;
Kinast, A.;
Kluck, H.;
Kraus, H.;
Langenkämper, A.;
Mancuso, M.;
Mokina, V.;
Mondragón, E.;
Olmi, M.;
Ortmann, T.;
Pagliarone, C.;
Palušová, V.;
Pattavina, L.;
Petricca, F.;
Potzel, W.;
Povinec, P.;
Pröbst, F.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schipperges, V.;
Schmiedmayer, D.;
Schönert, S.;
Schwertner, C.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Türkoğlu, C.;
Usherov, I.;
Willers, M.;
Zema, V.;
Zeman, J.
Submitted: 2019-08-19
The CRESST (Cryogenic Rare Event Search with Superconducting Thermometers)
dark matter search experiment aims for the detection of dark matter particles
via elastic scattering off nuclei in $\mathrm{CaWO_4}$ crystals. To understand
the CRESST electromagnetic background due to the bulk contamination in the
employed materials, a model based on Monte Carlo simulations was developed
using the Geant4 simulation toolkit. The results of the simulation are applied
to the TUM40 detector module of CRESST-II phase 2. We are able to explain up to
$(68 \pm 16)\,\mathrm{\%}$ of the electromagnetic background in the energy
range between $1\,\mathrm{keV}$ and $40\,\mathrm{keV}$.
[5]
oai:arXiv.org:1904.00498 [pdf] - 2007901
First results from the CRESST-III low-mass dark matter program
CRESST Collaboration;
Abdelhameed, A. H.;
Angloher, G.;
Bauer, P.;
Bento, A.;
Bertoldo, E.;
Bucci, C.;
Canonica, L.;
D'Addabbo, A.;
Defay, X.;
Di Lorenzo, S.;
Erb, A.;
Feilitzsch, F. v.;
Fichtinger, S.;
Iachellini, N. Ferreiro;
Fuss, A.;
Gorla, P.;
Hauff, D.;
Jochum, J.;
Kinast, A.;
Kluck, H.;
Kraus, H.;
Langenkämper, A.;
Mancuso, M.;
Mokina, V.;
Mondragon, E.;
Münster, A.;
Olmi, M.;
Ortmann, T.;
Pagliarone, C.;
Pattavina, L.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schipperges, V.;
Schmiedmayer, D.;
Schönert, S.;
Schwertner, C.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Türkoglu, C.;
Usherov, I.;
Willers, M.;
Zema, V.
Submitted: 2019-03-31
The CRESST experiment is a direct dark matter search which aims to measure
interactions of potential dark matter particles in an earth-bound detector.
With the current stage, CRESST-III, we focus on a low energy threshold for
increased sensitivity towards light dark matter particles. In this manuscript
we describe the analysis of one detector operated in the first run of
CRESST-III (05/2016-02/2018) achieving a nuclear recoil threshold of 30.1eV.
This result was obtained with a 23.6g CaWO$_4$ crystal operated as a cryogenic
scintillating calorimeter in the CRESST setup at the Laboratori Nazionali del
Gran Sasso (LNGS). Both the primary phonon/heat signal and the simultaneously
emitted scintillation light, which is absorbed in a separate
silicon-on-sapphire light absorber, are measured with highly sensitive
transition edge sensors operated at ~15mK. The unique combination of these
sensors with the light element oxygen present in our target yields sensitivity
to dark matter particle masses as low as 160MeV/c$^2$.
[6]
oai:arXiv.org:1706.08666 [pdf] - 1601501
DEPFET detectors for direct detection of MeV Dark Matter particles
Submitted: 2017-06-27, last modified: 2017-12-09
The existence of dark matter is undisputed, while the nature of it is still
unknown. Explaining dark matter with the existence of a new unobserved particle
is among the most promising possible solutions. Recently dark matter candidates
in the MeV mass region received more and more interest. In comparison to the
mass region between a few GeV to several TeV, this region is experimentally
largely unexplored. We discuss the application of a RNDR DEPFET semiconductor
detector for direct searches for dark matter in the MeV mass region. We present
the working principle of the RNDR DEPFET devices and review the performance
obtained by previously performed prototype measurements. The future potential
of the technology as dark matter detector is discussed and the sensitivity for
MeV dark matter detection with RNDR DEPFET sensors is presented. Under the
assumption of three background events in the region of interest and an exposure
of one kg$\cdot$y a sensitivity of $\bar{\sigma}_{\bar{e}} = 10^{-41}$ cm$^{2}$
for dark matter particles with a mass of 10 MeV can be reached.
[7]
oai:arXiv.org:1711.07692 [pdf] - 1591519
First results on low-mass dark matter from the CRESST-III experiment
CRESST collaboration;
Petricca, F.;
Angloher, G.;
Bauer, P.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Defay, X.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. C.;
Lagenkämper, A.;
Loebell, J.;
Mancuso, M.;
Mondragon, E.;
Münster, A.;
Pagliarone, C.;
Potzel, W.;
Pröbst, F.;
Puig, R.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schönert, S.;
Seidel, W.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Thi, H. H. Trinh;
Türkoğlu, C.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.
Submitted: 2017-11-21
The CRESST experiment, located at Laboratori Nazionali del Gran Sasso in
Italy, searches for dark matter particles via their elastic scattering off
nuclei in a target material. The CRESST target consists of scintillating
CaWO$_4$ crystals, which are operated as cryogenic calorimeters at millikelvin
temperatures. Each interaction in the CaWO$_4$ target crystal produces a phonon
signal and a light signal that is measured by a second cryogenic calorimeter.
Since the CRESST-II result in 2015, the experiment is leading the field of
direct dark matter search for dark matter masses below 1.7\,GeV/$c^2$,
extending the reach of direct searches to the sub-GeV/$c^2$ mass region. For
CRESST-III, whose Phase 1 started in July 2016, detectors have been optimized
to reach the performance required to further probe the low-mass region with
unprecedented sensitivity. In this contribution the achievements of the
CRESST-III detectors will be discussed together with preliminary results and
perspectives of Phase 1.
[8]
oai:arXiv.org:1711.01285 [pdf] - 1590722
Search for low-mass Dark Matter with the CRESST Experiment
Kluck, H.;
Angloher, G.;
Bauer, P.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Defay, X.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kraus, H.;
Lanfranchi, J. -C.;
Langenkämper, A.;
Loebell, J.;
Mancuso, M.;
Mondragon, E.;
Münster, A.;
Pagliarone, C.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Puig, R.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schönert, S.;
Seidel, W.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Thi, H. H. Trinh;
Türkoğlu, C.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.
Submitted: 2017-11-03
CRESST is a multi-stage experiment directly searching for dark matter (DM)
using cryogenic $\mathrm{CaWO_4}$ crystals. Previous stages established leading
limits for the spin-independent DM-nucleon cross section down to DM-particle
masses $m_\mathrm{DM}$ below $1\,\mathrm{GeV/c^2}$. Furthermore, CRESST
performed a dedicated search for dark photons (DP) which excludes new parameter
space between DP masses $m_\mathrm{DP}$ of $300\,\mathrm{eV/c^2}$ to
$700\,\mathrm{eV/c^2}$.
In this contribution we will discuss the latest results based on the previous
CRESST-II phase 2 and we will report on the status of the current CRESST-III
phase 1: in this stage we have been operating 10 upgraded detectors with
$24,\mathrm{g}$ target mass each and enhanced detector performance since summer
2016. The improved detector design in terms of background suppression and
reduction of the detection threshold will be discussed with respect to the
previous stage. We will conclude with an outlook on the potential of the next
stage, CRESST-III phase 2.
[9]
oai:arXiv.org:1707.06749 [pdf] - 1586208
Results on MeV-scale dark matter from a gram-scale cryogenic calorimeter
operated above ground
Angloher, G.;
Bauer, P.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Defay, X.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. -C.;
Loebell, A. Langenkämper J.;
Mancuso, M.;
Mondragon, E.;
Münster, A.;
Oberauer, L.;
Pagliarone, C.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Puig, R.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schönert, S.;
Seidel, W.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Thi, H. H. Trinh;
Türkoglu, C.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2017-07-20, last modified: 2017-09-18
Models for light dark matter particles with masses below 1 GeV/c$^2$ are a
natural and well-motivated alternative to so-far unobserved weakly interacting
massive particles. Gram-scale cryogenic calorimeters provide the required
detector performance to detect these particles and extend the direct dark
matter search program of CRESST. A prototype 0.5 g sapphire detector developed
for the $\nu$-cleus experiment has achieved an energy threshold of
$E_{th}=(19.7\pm 0.9)$ eV, which is one order of magnitude lower than previous
results and independent of the type of particle interaction. The result
presented here is obtained in a setup above ground without significant
shielding against ambient and cosmogenic radiation. Although operated in a
high-background environment, the detector probes a new range of light-mass dark
matter particles previously not accessible by direct searches. We report the
first limit on the spin-independent dark matter particle-nucleon cross section
for masses between 140 MeV/c$^2$ and 500 MeV/c$^2$.
[10]
oai:arXiv.org:1708.01581 [pdf] - 1586787
Performance of a CRESST-II Detector Module with True $4\pi$-veto
Angloher, G.;
Bauer, P.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Defay, X.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. C.;
Langenkämper, A.;
Loebell, J.;
Mancuso, M.;
Münster, A.;
Pagliarone, C.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schönert, V. Schipperges S.;
Seidel, W.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Thi, H. H. Trinh;
Türkoğlu, C.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2017-08-04
Scintillating, cryogenic bolometers are widely used in the field of rare
event searches. Their main advantages are an excellent energy resolution and
particle identification on an event-by-event basis. The sensitivity of
experiments applying this detector technique can be limited by the performance
of the light channel and the presence of external backgrounds in the region of
interest. In the framework of the CRESST-II experiment, we developed and
successfully tested a novel detector design addressing both challenges. Using a
large scale ($\approx$\unit[60]{cm$^2$}), beaker-shaped silicon light absorber,
the signal height recorded in the light channel is improved by a factor 2.5
compared to conventional CRESTT-II detector modules. In combination with a
large carrier crystal, a true $4\pi$ veto system is established which allows to
tag external background sources.
[11]
oai:arXiv.org:1503.07806 [pdf] - 1530245
In-situ study of light production and transport in phonon/light detector
modules for dark matter search
Kiefer, M.;
Angloher, G.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. -C.;
Loebell, J.;
Münster, A.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Schäffner, K.;
Schieck, J.;
Schönert, S.;
Seidel, W.;
Sivers, M. v.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Türkoğlu, C.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2015-03-26, last modified: 2017-02-20
The CRESST experiment (Cryogenic Rare Event Search with Superconducting
Thermometers) searches for dark matter via the phonon and light signals of
elastic scattering processes in scintillating crystals. The discrimination
between a possible dark matter signal and background is based on the light
yield. We present a new method for evaluating the two characteristics of a
phonon/light detector module that determine how much of the deposited energy is
converted to scintillation light and how efficiently a module detects the
produced light. In contrast to former approaches with dedicated setups, we
developed a method which allows us to use data taken with the cryogenic setup,
during a dark matter search phase. In this way, we accounted for the entire
process that occurs in a detector module, and obtained information on the light
emission of the crystal as well as information on the performance of the module
(light transport and detection). We found that with the detectors operated in
CRESST-II phase 1, about 20% of the produced scintillation light is detected. A
part of the light is likely absorbed by creating meta-stable excitations in the
scintillating crystals. The light not detected is not absorbed entirely, as an
additional light detector can help to increase the fraction of detected light.
[12]
oai:arXiv.org:1611.02113 [pdf] - 1509578
Direct Dark Matter Search with the CRESST II Experiment
Schieck, J;
Angloher, G;
Bento, A;
Bucci, C;
Canonica, L;
Defay, X;
Erb, A;
Feilitzsch, F v;
Iachellini, N Ferreiro;
Gorla, P;
Guetlein, A;
Hauff, D;
Jochum, J;
Kiefer, M;
Kluck, H;
Kraus, H;
Lanfranchi, J-C;
Loebell, J;
Mancuso, M;
Muenster, A;
Pagliarone, C;
Petricca, F;
Potzel, W;
Pröbst, F;
Puig, R;
Reindl, F;
Schaeffner, K;
Schoenert, S;
Seidel, W;
Stahlberg, M;
Stodolsky, L;
Strandhagen, C;
Strauss, R;
Tanzke, A;
Thi, H H Trinh;
Turkoglu, C;
Uffinger, M;
Ulrich, A;
Usherov, I;
Wawoczny, S;
Willers, M;
Wueustrich, M;
Zoeller, A
Submitted: 2016-11-07
The quest for the particle nature of dark matter is one of the big open
questions of modern physics. A well motivated candidate for dark matter is the
so-called WIMP - a weakly interacting massive particle. Recently several
theoretically well-motivated models with dark matter candidates in a mass
region below the WIMP mass-scale gained also a lot of interest, theoretically
and experimentally. The CRESST II experiment located at the Gran Sasso
laboratory in Italy is optimised for the detection of the elastic scattering of
these low-mass dark matter particles with ordinary matter. We show the results
obtained with an improved detector setup with increased radio purity and
enhanced background rejection and the results obtained with a dedicated
low-threshold analysis of a single conventional detector module. The limit
achieved is the most stringent limit achieved for direct dark matter
experiments in the mass region below 1.8 GeV/$c^{2}$. We will discuss the
expected performance for new small CRESST-type detectors to be used during the
next data taking phase. We conclude with an outlook of the future potential for
direct dark matter detection using further improved CRESST CaWO$_{4}$ cryogenic
detectors.
[13]
oai:arXiv.org:1601.04447 [pdf] - 1439730
Limits on momentum-dependent asymmetric dark matter with CRESST-II
Angloher, G.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Defay, X.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. -C.;
Loebell, J.;
Münster, A.;
Pagliarone, C.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Schäffner, K.;
Schieck, J.;
Schönert, S.;
Seidel, W.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Thi, H. H. Trinh;
Türkoğlu, C.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2016-01-18, last modified: 2016-07-19
The usual assumption in direct dark matter searches is to only consider the
spin-dependent or spin-independent scattering of dark matter particles.
However, especially in models with light dark matter particles
$\mathcal{O}(\mathrm{GeV/c^2})$, operators which carry additional powers of the
momentum transfer $q^2$ can become dominant. One such model based on asymmetric
dark matter has been invoked to overcome discrepancies in helioseismology and
an indication was found for a particle with preferred mass of 3
$\mathrm{GeV/c^2}$ and cross section of $10^{-37} \mathrm{cm^2}$. Recent data
from the CRESST-II experiment, which uses cryogenic detectors based on
$\mathrm{CaWO_4}$ to search for nuclear recoils induced by dark matter
particles, are used to constrain these momentum-dependent models. The low
energy threshold of 307 eV for nuclear recoils of the detector used, allows us
to rule out the proposed best fit value above.
[14]
oai:arXiv.org:1509.01515 [pdf] - 1357396
Results on light dark matter particles with a low-threshold CRESST-II
detector
The CRESST Collaboration;
Angloher, G.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Defay, X.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. C.;
Loebell, J.;
Münster, A.;
Pagliarone, C.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Schäffner, K.;
Schieck, J.;
Schönert, S.;
Seidel, W.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Thi, H. H. Trinh;
Türkoğlu, C.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2015-09-04, last modified: 2016-02-12
The CRESST-II experiment uses cryogenic detectors to search for nuclear
recoil events induced by the elastic scattering of dark matter particles in
CaWO$_4$ crystals. Given the low energy threshold of our detectors in
combination with light target nuclei, low mass dark matter particles can be
probed with high sensitivity. In this letter we present the results from data
of a single detector module corresponding to 52 kg live days. A blind analysis
is carried out. With an energy threshold for nuclear recoils of 307 eV we
substantially enhance the sensitivity for light dark matter. Thereby, we extend
the reach of direct dark matter experiments to the sub-region and demonstrate
that the energy threshold is the key parameter in the search for low mass dark
matter particles.
[15]
oai:arXiv.org:1410.1753 [pdf] - 1345768
A detector module with highly efficient surface-alpha event rejection
operated in CRESST-II Phase 2
Strauss, R.;
Angloher, G.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Erb, A.;
Feilitzsch, F. v.;
Ferreiro, N.;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. -C.;
Loebell, J.;
Münster, A.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Schäffner, K.;
Schieck, J.;
Scholl, S.;
Schönert, S.;
Seidel, W.;
Sivers, M. v.;
Stanger, M.;
Stodolsky, L.;
Strandhagen, C.;
Tanzke, A.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2014-10-07, last modified: 2016-01-25
The cryogenic dark matter experiment CRESST-II aims at the direct detection
of WIMPs via elastic scattering off nuclei in scintillating CaWO$_4$ crystals.
We present a new, highly improved, detector design installed in the current run
of CRESST-II Phase 2 with an efficient active rejection of surface-alpha
backgrounds. Using CaWO$_4$ sticks instead of metal clamps to hold the target
crystal, a detector housing with fully-scintillating inner surface could be
realized. The presented detector (TUM40) provides an excellent threshold of
${\sim}\,0.60\,$keV and a resolution of $\sigma\,{\approx}\,0.090$ keV (at
2.60$\,$keV). With significantly reduced background levels, TUM40 sets
stringent limits on the spin-independent WIMP-nucleon scattering cross section
and probes a new region of parameter space for WIMP masses below
3$\,$GeV/c$^2$. In this paper, we discuss the novel detector design and the
surface-alpha event rejection in detail.
[16]
oai:arXiv.org:1509.09124 [pdf] - 1286174
The CRESST Dark Matter Search - Status and Perspectives
The CRESST Collaboration;
Reindl, F.;
Angloher, G.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Defay, X.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. C.;
Loebell, J.;
Münster, A.;
Pagliarone, C.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Schäffner, K.;
Schieck, J.;
Schönert, S.;
Seidel, W.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Thi, H. H. Trinh;
Türkoğlu, C.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2015-09-30
In the past years the spotlight of the search for dark matter particles
widened to the low mass region, both from theoretical and experimental side. We
discuss results from data obtained in 2013 with a single detector TUM40. This
detector is equipped with a new upgraded holding scheme to efficiently veto
backgrounds induced by surface alpha decays. This veto, the low threshold of
0.6keV and an unprecedented background level for CaWO$_4$ target crystals
render TUM40 the detector with the best overall performance of CRESST-II phase
2 (July 2013 - August 2015). A low-threshold analysis allowed to investigate
light dark matter particles (<3GeV/c$^2$), previously not accessible for other
direct detection experiments.
[17]
oai:arXiv.org:1503.08065 [pdf] - 972114
Probing low WIMP masses with the next generation of CRESST detector
The CRESST Collaboration;
Angloher, G.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. -C.;
Loebell, J.;
Münster, A.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Schäffner, K.;
Schieck, J.;
Scholl, S.;
Schönert, S.;
Seidel, W.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2015-03-27
The purpose of this document is to describe the upgrade of the CRESST dark
matter search at LNGS. The proposed strategy will allow to explore a region of
the parameter space for spin-independent WIMP-nucleon elastic scattering
corresponding to WIMP masses below 10GeV/c$^\text{2}$, that has not been
covered by other experiments. These results can be achieved only with
outstanding detector performances in terms of threshold and background. This
proposal shows how CRESST can match these performance requirements, adding a
unique piece of information to the dark matter puzzle. The results of this
program will fix a new state-of-the-art in the low mass WIMP exploration,
opening new perspectives of understanding the dark matter scenario.
[18]
oai:arXiv.org:1407.3146 [pdf] - 925077
Results on low mass WIMPs using an upgraded CRESST-II detector
CRESST Collaboration;
Angloher, G.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Huff, P.;
Jochum, J.;
Kiefer, M.;
Kister, C.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. -C.;
Loebell, J.;
Münster, A.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Schäffner, K.;
Schieck, J.;
Schmaler, J.;
Scholl, S.;
Schönert, S.;
Seidel, W.;
Sivers, M. v.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2014-07-11, last modified: 2015-01-22
The CRESST-II cryogenic dark matter search aims for the detection of WIMPs
via elastic scattering off nuclei in CaWO$_4$ crystals. We present results from
a low-threshold analysis of a single upgraded detector module. This module
efficiently vetoes low energy backgrounds induced by $\alpha$-decays on inner
surfaces of the detector. With an exposure of \unit[29.35]{kg live days}
collected in 2013 we set a limit on spin-independent WIMP-nucleon scattering
which probes a new region of parameter space for WIMP masses below
\unit[3]{GeV/c$^2$}, previously not covered in direct detection searches. A
possible excess over background discussed for the previous CRESST-II phase 1
(from 2009 to 2011) is not confirmed.
[19]
oai:arXiv.org:1307.1488 [pdf] - 844079
Axion searches with the EDELWEISS-II experiment
Armengaud, E.;
Arnaud, Q.;
Augier, C.;
Benoit, A.;
Benoit, A.;
Bergé, L.;
Bergmann, T.;
Blümer, J.;
Broniatowski, A.;
Brudanin, V.;
Camus, P.;
Cazes, A.;
Censier, B.;
Chapellier, M.;
Charlieux, F.;
Couëdo, F.;
Coulter, P.;
Cox, G. A.;
de Boissière, T.;
De Jesus, M.;
Dolgorouky, Y.;
Drillien, A. A.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Fourches, N.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hehn, L.;
Henry, S.;
Hervé, S.;
Heuermann, G.;
Holtzer, N.;
Humbert, V.;
Juillard, A.;
Kéfélian, C.;
Kleifges, M.;
Kluck, H.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Sueur, H. Le;
Mancuso, M.;
Marrache-Kikuchi, C.;
Marnieros, S.;
Menshikov, A.;
Navick, X-F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Piro, M. C.;
Rigaut, O.;
Robinson, M.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Siebenborn, B.;
Tcherniakhovski, D.;
Tenconi, M.;
Vagneron, L.;
Walker, R. J.;
Weber, M.;
Yakushev, E.;
Zhang, X.
Submitted: 2013-07-04
We present new constraints on the couplings of axions and more generic
axion-like particles using data from the EDELWEISS-II experiment. The EDELWEISS
experiment, located at the Underground Laboratory of Modane, primarily aims at
the direct detection of WIMPs using germanium bolometers. It is also sensitive
to the low-energy electron recoils that would be induced by solar or dark
matter axions. Using a total exposure of up to 448 kg.d, we searched for
axion-induced electron recoils down to 2.5 keV within four scenarios involving
different hypotheses on the origin and couplings of axions. We set a 95% CL
limit on the coupling to photons $g_{A\gamma}<2.13\times 10^{-9}$ GeV$^{-1}$ in
a mass range not fully covered by axion helioscopes. We also constrain the
coupling to electrons, $g_{Ae} < 2.56\times 10^{-11}$, similar to the more
indirect solar neutrino bound. Finally we place a limit on $g_{Ae}\times
g_{AN}^{\rm eff}<4.70 \times 10^{-17}$, where $g_{AN}^{\rm eff}$ is the
effective axion-nucleon coupling for $^{57}$Fe. Combining these results we
fully exclude the mass range $0.91\,{\rm eV}<m_A<80$ keV for DFSZ axions and
$5.73\,{\rm eV}<m_A<40$ keV for KSVZ axions.
[20]
oai:arXiv.org:1302.7112 [pdf] - 633724
Muon-induced background in the EDELWEISS dark matter search
The EDELWEISS collaboration;
Schmidt, B.;
Armengaud, E.;
Augier, C.;
Benoit, A.;
Bergé, L.;
Bergmann, T.;
Blümer, J.;
Bres, G.;
Broniatowski, A.;
Brudanin, V.;
Censier, B.;
Chapellier, M.;
Charlieux, F.;
Collin, S.;
Coulter, P.;
Cox, G. A.;
Crauste, O.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Fourches, N.;
Garde, G.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hehn, L.;
Henry, S.;
Hervé, S.;
Heuermann, G.;
Juillard, A.;
Kluck, H.;
Kozlov, V. Y.;
Kleifges, M.;
Kraus, H.;
Kudryavtsev, V. A.;
Loaiza, P.;
Marnieros, S.;
Menshikov, A.;
Navick, X. -F.;
Nieder, H.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Robinson, M.;
Rodenas, H.;
Rozov, S.;
Sanglard, V.;
Siebenborn, B.;
Tcherniakhovski, D.;
Torrentó-Coello, A. S.;
Vagneron, L.;
Walker, R. J.;
Weber, M.;
Yakushev, E.;
Zhang, X.
Submitted: 2013-02-28
A dedicated analysis of the muon-induced background in the EDELWEISS dark
matter search has been performed on a data set acquired in 2009 and 2010. The
total muon flux underground in the Laboratoire Souterrain de Modane (LSM) was
measured to be $\Phi_{\mu}=(5.4\pm 0.2 ^{+0.5}_{-0.9})$\,muons/m$^2$/d. The
modular design of the muon-veto system allows the reconstruction of the muon
trajectory and hence the determination of the angular dependent muon flux in
LSM. The results are in good agreement with both MC simulations and earlier
measurements. Synchronization of the muon-veto system with the phonon and
ionization signals of the Ge detector array allowed identification of
muon-induced events. Rates for all muon-induced events $\Gamma^{\mu}=(0.172 \pm
0.012)\, \rm{evts}/(\rm{kg \cdot d})$ and of WIMP-like events $\Gamma^{\mu-n} =
0.008^{+0.005}_{-0.004}\, \rm{evts}/(\rm{kg \cdot d})$ were extracted. After
vetoing, the remaining rate of accepted muon-induced neutrons in the
EDELWEISS-II dark matter search was determined to be $\Gamma^{\mu-n}_{\rm
irred} < 6\cdot 10^{-4} \, \rm{evts}/(\rm{kg \cdot d})$ at 90%\,C.L. Based on
these results, the muon-induced background expectation for an anticipated
exposure of 3000\,\kgd\ for EDELWEISS-3 is $N^{\mu-n}_{3000 kg\cdot d} < 0.6$
events.
[21]
oai:arXiv.org:1207.1815 [pdf] - 568705
A search for low-mass WIMPs with EDELWEISS-II heat-and-ionization
detectors
EDELWEISS Collaboration;
Armengaud, E.;
Augier, C.;
Benoît, A.;
Bergé, L.;
Bergmann, T.;
Blümer, J.;
Broniatowski, A.;
Brudanin, V.;
Censier, B.;
Chapellier, M.;
Charlieux, F.;
Couëdo, F.;
Coulter, P.;
Cox, G. A.;
Domange, J.;
Drillien, A. A.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Fourches, N.;
Gascon, J.;
Gerbier, G.;
Gironnet, J.;
Gros, M.;
Heuermann, G.;
Henry, S.;
Hervé, S.;
Juillard, A.;
Kleifges, M.;
Kluck, H.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Sueur, H. Le;
Loaiza, P.;
Marnieros, S.;
Menshikov, A.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Robinson, M.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Siebenborn, B.;
Tcherniakhovski, D.;
Torrento-Coello, A. S.;
Vagneron, L.;
Walker, R. J.;
Weber, M.;
Yakushev, E.;
Zhang, X.
Submitted: 2012-07-07, last modified: 2012-09-05
We report on a search for low-energy (E < 20 keV) WIMP-induced nuclear
recoils using data collected in 2009 - 2010 by EDELWEISS from four germanium
detectors equipped with thermal sensors and an electrode design (ID) which
allows to efficiently reject several sources of background. The data indicate
no evidence for an exponential distribution of low-energy nuclear recoils that
could be attributed to WIMP elastic scattering after an exposure of 113 kg.d.
For WIMPs of mass 10 GeV, the observation of one event in the WIMP search
region results in a 90% CL limit of 1.0x10^-5 pb on the spin-independent
WIMP-nucleon scattering cross-section, which constrains the parameter space
associated with the findings reported by the CoGeNT, DAMA and CRESST
experiments.
[22]
oai:arXiv.org:1103.4070 [pdf] - 966535
Final results of the EDELWEISS-II WIMP search using a 4-kg array of
cryogenic germanium detectors with interleaved electrodes
EDELWEISS Collaboration;
Armengaud, E.;
Augier, C.;
Benoît, A.;
Bergé, L.;
Blümer, J.;
Broniatowski, A.;
Brudanin, V.;
Censier, B.;
Chardin, G.;
Chapellier, M.;
Charlieux, F.;
Coulter, P.;
Cox, G. A.;
Defay, X.;
De Jesus, M.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Fourches, N.;
Gascon, J.;
Gerbier, G.;
Gironnet, J.;
Gros, M.;
Henry, S.;
Hervé, S.;
Juillard, A.;
Kluck, H.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Loaiza, P.;
Marnieros, S.;
Navick, X-F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Pattavina, L.;
Paul, B.;
Robinson, M.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Scorza, S.;
Semikh, S.;
Torrento-Coello, A-S.;
Vagneron, L.;
Verdier, M-A.;
Walker, R. J.;
Yakushev, E.
Submitted: 2011-03-21, last modified: 2011-08-31
The EDELWEISS-II collaboration has completed a direct search for WIMP dark
matter with an array of ten 400-g cryogenic germanium detectors in operation at
the Laboratoire Souterrain de Modane. The combined use of thermal phonon
sensors and charge collection electrodes with an interleaved geometry enables
the efficient rejection of gamma-induced radioactivity as well as near-surface
interactions. A total effective exposure of 384 kg.d has been achieved, mostly
coming from fourteen months of continuous operation. Five nuclear recoil
candidates are observed above 20 keV, while the estimated background is 3.0
events. The result is interpreted in terms of limits on the cross-section of
spin-independent interactions of WIMPs and nucleons. A cross-section of
4.4x10^-8 pb is excluded at 90%CL for a WIMP mass of 85 GeV. New constraints
are also set on models where the WIMP-nucleon scattering is inelastic.
[23]
oai:arXiv.org:1105.3377 [pdf] - 966800
Combined Limits on WIMPs from the CDMS and EDELWEISS Experiments
CDMS;
Collaborations, EDELWEISS;
:;
Ahmed, Z.;
Akerib, D. S.;
Armengaud, E.;
Arrenberg, S.;
Augier, C.;
Bailey, C. N.;
Balakishiyeva, D.;
Baudis, L.;
Bauer, D. A.;
Benoît, A.;
Bergé, L.;
Blümer, J.;
Brink, P. L.;
Broniatowski, A.;
Bruch, T.;
Brudanin, V.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Censier, B.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Cooley, J.;
Coulter, P.;
Cox, G. A.;
Cushman, P.;
Daal, M.;
Defay, X.;
De Jesus, M.;
DeJongh, F.;
Di Stefano, P. C. F.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Dragowsky, M. R.;
Eitel, K.;
Fallows, S.;
Figueroa-Feliciano, E.;
Filippini, J.;
Filosofov, D.;
Fourches, N.;
Fox, J.;
Fritts, M.;
Gascon, J.;
Gerbier, G.;
Gironnet, J.;
Golwala, S. R.;
Gros, M.;
Hall, J.;
Hennings-Yeomans, R.;
Henry, S.;
Hertel, S. A.;
Hervé, S.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Juillard, A.;
Kamaev, O.;
Kiveni, M.;
Kluck, H.;
Kos, M.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Leman, S. W.;
Liu, S.;
Loaiza, P.;
Mahapatra, R.;
Mandic, V.;
Marnieros, S.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moore, D.;
Nadeau, P.;
Navick, X-F.;
Nelson, H.;
Nones, C.;
Ogburn, R. W.;
Olivieri, E.;
Pari, P.;
Pattavina, L.;
Paul, B.;
Phipps, A.;
Pyle, M.;
Qiu, X.;
Rau, W.;
Reisetter, A.;
Ricci, Y.;
Robinson, M.;
Rozov, S.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Sanglard, V.;
Schmidt, B.;
Schnee, R. W.;
Scorza, S.;
Seitz, D. N.;
Semikh, S.;
Serfass, B.;
Sundqvist, K. M.;
Tarka, M.;
Torrento-Coello, A. S.;
Vagneron, L.;
Verdier, M. -A.;
Walker, R. J.;
Wikus, P.;
Yakushev, E.;
Yellin, S.;
Yoo, J.;
Young, B. A.;
Zhang, J.
Submitted: 2011-05-17, last modified: 2011-07-08
The CDMS and EDELWEISS collaborations have combined the results of their
direct searches for dark matter using cryogenic germanium detectors. The total
data set represents 614 kg.d equivalent exposure. A straightforward method of
combination was chosen for its simplicity before data were exchanged between
experiments. The results are interpreted in terms of limits on spin-independent
WIMP-nucleon cross-section. For a WIMP mass of 90 GeV/c^2, where this analysis
is most sensitive, a cross-section of 3.3 x 10^{-44} cm^2 is excluded at 90%
CL. At higher WIMP masses, the combination improves the individual limits, by a
factor 1.6 above 700 GeV/c^2. Alternative methods of combining the data provide
stronger constraints for some ranges of WIMP masses and weaker constraints for
others.
[24]
oai:arXiv.org:1006.3098 [pdf] - 190656
A detection system to measure muon-induced neutrons for direct Dark
Matter searches
Kozlov, V. Yu.;
Armengaud, E.;
Augier, C.;
Benoit, A.;
Berge, L.;
Besida, O.;
Blumer, J.;
Broniatowski, A.;
Brudanin, V.;
Chantelauze, A.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Collin, S.;
Defay, X.;
De Jesus, M.;
Di Stefano, P.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hannawald, M.;
Herve, S.;
Juillard, A.;
Kluck, H.;
Lemrani, R.;
Loaiza, P.;
Lubashevskiy, A.;
Marnieros, S.;
Navick, X. -F.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Rozov, S.;
Sanglard, V.;
Scorza, S.;
Semikh, S.;
Torrento-Coello, A. S.;
Vagneron, L.;
Verdier, M-A.;
Yakushev, E.
Submitted: 2010-06-15
Muon-induced neutrons constitute a prominent background component in a number
of low count rate experiments, namely direct searches for Dark Matter. In this
work we describe a neutron detector to measure this background in an
underground laboratory, the Laboratoire Souterrain de Modane. The system is
based on 1 m3 of Gd-loaded scintillator and it is linked with the muon veto of
the EDELWEISS-II experiment for coincident muon detection. The system was
installed in autumn 2008 and passed since then a number of commissioning tests
proving its full functionality. The data-taking is continuously ongoing and a
count rate of the order of 1 muon-induced neutron per day has been achieved.
[25]
oai:arXiv.org:1001.4383 [pdf] - 33100
Monitoring of the thermal neutron flux in the LSM underground laboratory
Rozov, S.;
Armengaud, E.;
Augier, C.;
Bergé, L.;
Benoit, A.;
Besida, O.;
Blümer, J.;
Broniatowski, A.;
Brudanin, V.;
Chantelauze, A.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Collin, S.;
Crauste, O.;
De Jesus, M.;
Defay, X.;
Di Stefano, P.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hannawald, M.;
Juillard, A.;
Kluck, H.;
Kozlov, V.;
Lemrani, R.;
Lubashevskiy, A.;
Marrach, C.;
Marnieros, S.;
Navick, X-F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Sanglard, V.;
Scorza, S.;
Semikh, S.;
Verdier, M-A.;
Vagneron, L.;
Yakushev, E.
Submitted: 2010-01-25
This paper describes precise measurements of the thermal neutron flux in the
LSM underground laboratory in proximity of the EDELWEISS-II dark matter search
experiment together with short measurements at various other locations.
Monitoring of the flux of thermal neutrons is accomplished using a mobile
detection system with low background proportional counter filled with $^3$He.
On average 75 neutrons per day are detected with a background level below 1
count per day (cpd). This provides a unique possibility of a day by day study
of variations of the neutron field in a deep underground site. The measured
average 4$\pi$ neutron flux per cm$^{2}$ in the proximity of EDELWEISS-II is
$\Phi_{MB}=3.57\pm0.05^{stat}\pm0.27^{syst}\times 10^{-6}$ neutrons/sec. We
report the first experimental observation that the point-to-point thermal
neutron flux at LSM varies by more than a factor two.
[26]
oai:arXiv.org:0912.0805 [pdf] - 157860
First results of the EDELWEISS-II WIMP search using Ge cryogenic
detectors with interleaved electrodes
Armengaud, E.;
Augier, C.;
Benoit, A.;
Berge, L.;
Besida, O.;
Blumer, J.;
Broniatowski, A.;
Chantelauze, A.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Collin, S.;
Defay, X.;
De Jesus, M.;
Di Stefano, P.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hannawald, M.;
Herve, S.;
Juillard, A.;
Kluck, H.;
Kozlov, V.;
Lemrani, R.;
Loaiza, P.;
Lubashevskiy, A.;
Marnieros, S.;
Navick, X-F.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Rozov, S.;
Sanglard, V.;
Scorza, S.;
Semikh, S.;
Torrento-Coello, A. S.;
Vagneron, L.;
Verdier, M-A.;
Yakushev, E.;
Collaboration, the EDELWEISS
Submitted: 2009-12-04
The EDELWEISS-II collaboration has performed a direct search for WIMP dark
matter with an array of ten 400 g heat-and-ionization cryogenic detectors
equipped with interleaved electrodes for the rejection of near-surface events.
Six months of continuous operation at the Laboratoire Souterrain de Modane have
been achieved. The observation of one nuclear recoil candidate above 20 keV in
an effective exposure of 144 kgd is interpreted in terms of limits on the
cross-section of spin-independent interactions of WIMPs and nucleons. A
cross-section of 1.0x10^-7 pb is excluded at 90%CL for a WIMP mass of 80
GeV/c2. This result demonstrates for the first time the very high background
rejection capabilities of these simple and robust detectors in an actual WIMP
search experiment.
[27]
oai:arXiv.org:0905.0753 [pdf] - 369040
A new high-background-rejection dark matter Ge cryogenic detector
Broniatowski, A.;
Defay, X.;
Armengaud, E.;
Berge, L.;
Benoit, A.;
Besida, O.;
Blumer, J.;
Chantelauze, A.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Collin, S.;
Crauste, O.;
De Jesus, M.;
Di Stefano, P.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hannawald, M.;
Herve, S.;
Juillard, A.;
Kluck, H.;
Kozlov, V.;
Lemrani, R.;
Lubashevskiy, A.;
Marrache, C.;
Marnieros, S.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Rozov, S.;
Sanglard, V.;
Scorza, S.;
Semikh, S.;
Verdier, M. -A.;
Vagneron, L.;
Yakushev, E.
Submitted: 2009-05-06
A new design of a cryogenic germanium detector for dark matter search is
presented, taking advantage of the coplanar grid technique of event
localisation for improved background discrimination. Experiments performed with
prototype devices in the EDELWEISS II setup at the Modane underground facility
demonstrate the remarkably high efficiency of these devices for the rejection
of low-energy $\beta$, approaching 10$^5$ . This opens the road to investigate
the range beyond 10$^{-8}$ pb in the WIMP-nucleon collision cross-sections, as
proposed in the EURECA project of a one-ton cryogenic detector mass.