Normalized to: Kiviranta, M.
[1]
oai:arXiv.org:2003.11899 [pdf] - 2070581
Progress in the development of frequency domain multiplexing for the
X-ray Integral Field Unit on board the Athena mission
Akamatsu, H.;
Gottardi, L.;
van der Kuur, J.;
de Vries, C. P.;
Bruijn, M. P.;
Chervenak, J. A.;
Kiviranta, M.;
Linden, A. J. van den;
Jackson, B. D.;
Miniussi, A.;
Ravensberg, K.;
Sakai, K.;
Smith, S. J.;
Wakeham, N.
Submitted: 2020-03-26
Frequency domain multiplexing (FDM) is the baseline readout system for the
X-ray Integral Field Unit (X-IFU) on board the Athena mission. Under the FDM
scheme, TESs are coupled to a passive LC filter and biased with alternating
current (AC bias) at MHz frequencies. Using high-quality factor LC filters and
room temperature electronics developed at SRON and low-noise two-stage SQUID
amplifiers provided by VTT, we have recently demonstrated good performance with
the FDM readout of Mo/Au TES calorimeters with Au/Bi absorbers. We have
achieved a performance requested for the demonstration model (DM) with the
single pixel AC bias ($\Delta E=$1.8 eV) and 9 pixel multiplexing ($\Delta
E=$2.6 eV) modes. We have also demonstrated 14-pixel multiplexing with an
average energy resolution of 3.3 eV, which is limited by non-fundamental issues
related to FDM readout in our lab setup.
[2]
oai:arXiv.org:1810.09122 [pdf] - 1770848
Two SQUID amplifiers intended to alleviate the summing node inductance
problem in multiplexed arrays of Transition Edge Sensors
Submitted: 2018-10-22
Frequency Domain Multiplexed detector arrays constructed of superconducting
Transition Edge Sensors in the current-summing configuration suffer from the
finite impedance of the summing node which should ideally be zero. We suggest
two circuits to alleviate the effect. The first circuit uses a capacitive
resonant transformer to increase the voltages and decrease the currents of TES
signals to overcome the parasitic inductance of the interconnections. On the
SQUID chip impedance transform to the opposite direction takes place. The
second circuit implements a power combiner having a better branch-to-branch
isolation than a simple T-junction. Two SQUID devices have been designed and
fabricated for a proof-of-principle demonstration of the circuits.
[3]
oai:arXiv.org:1810.04706 [pdf] - 1764927
Low-dissipating push-pull SQUID amplifier for TES detector readout
Submitted: 2018-10-10
We suggest SQUID amplifier configuration intended for millikelvin
refrigerators where cooling power is limited and hence high power efficiency is
desirable. The configuration operates the SQUIDs in class-AB rather than the
traditional class-A. A proof-of principle demonstration at T = 4.2 K is
presented.
[4]
oai:arXiv.org:1611.05268 [pdf] - 1515839
Optimising the multiplex factor of the frequency domain multiplexed
readout of the TES-based microcalorimeter imaging array for the X-IFU
instrument on the Athena Xray observatory
Submitted: 2016-11-16
Athena is a space-based X-ray observatory intended for exploration of the hot
and energetic universe. One of the science instruments on Athena will be the
X-ray Integrated Field Unit (X-IFU), which is a cryogenic X-ray spectrometer,
based on a large cryogenic imaging array of Transition Edge Sensors (TES) based
microcalorimeters operating at a temperature of 100mK. The imaging array
consists of 3800 pixels providing 2.5 eV spectral resolution, and covers a
field of view with a diameter of of 5 arc minutes. Multiplexed readout of the
cryogenic microcalorimeter array is essential to comply with the cooling power
and complexity constraints on a space craft. Frequency domain multiplexing has
been under development for the readout of TES-based detectors for this purpose,
not only for the X-IFU detector arrays but also for TES-based bolometer arrays
for the Safari instrument of the Japanese SPICA observatory. This paper
discusses the design considerations which are applicable to optimise the
multiplex factor within the boundary conditions as set by the space craft. More
specifically, the interplay between the science requirements such as pixel
dynamic range, pixel speed, and cross talk, and the space craft requirements
such as the power dissipation budget, available bandwidth, and electromagnetic
compatibility will be discussed.
[5]
oai:arXiv.org:1611.00956 [pdf] - 1521434
Development of frequency domain multiplexing for the X-ray Integral
Field Unit (X-IFU) on the Athena
Akamatsu, Hiroki;
Gottardi, Luciano;
van der Kuur, Jan;
de Vries, Cor P.;
Ravensberg, Kevin;
Adams, Joseph S.;
Bandler, Simon R.;
Bruijn, Marcel P.;
Chervenak, James A.;
Kilbourne, Caroline A;
Kiviranta, Mikko;
Linden, A. J. van den;
Jackson, Brian D.;
Smith, Stephen J.
Submitted: 2016-11-03
We are developing the frequency domain multiplexing (FDM) read-out of
transition-edge sensor (TES) microcalorimeters for the X-ray Integral Field
Unit (X-IFU) instrument on board of the future European X-Ray observatory
Athena. The X-IFU instrument consists of an array of $\sim$3840 TESs with a
high quantum efficiency ($>$90 \%) and spectral resolution $\Delta E$=2.5 eV
$@$ 7 keV ($E/\Delta E\sim$2800). FDM is currently the baseline readout system
for the X-IFU instrument. Using high quality factor LC filters and room
temperature electronics developed at SRON and low-noise two stage SQUID
amplifiers provided by VTT, we have recently demonstrated good performance with
the FDM readout of Mo/Au TES calorimeters with Au/Bi absorbers. An integrated
noise equivalent power resolution of about 2.0 eV at 1.7 MHz has been
demonstrated with a pixel from a new TES array from NASA/Goddard (GSFC-A2). We
have achieved X-ray energy resolutions $\sim$2.5 eV at AC bias frequency at 1.7
MHz in the single pixel read-out. We have also demonstrated for the first time
an X-ray energy resolution around 3.0 eV in a 6 pixel FDM read-out with TES
array (GSFC-A1). In this paper we report on the single pixel performance of
these microcalorimeters under MHz AC bias, and further results of the
performance of these pixels under FDM.
[6]
oai:arXiv.org:1604.00670 [pdf] - 1489757
Development of the superconducting detectors and read-out for the X-IFU
instrument on board of the X-ray observatory Athena
Submitted: 2016-04-03
The Advanced Telescope for High-Energy Astrophysics (Athena) has been
selected by ESA as its second large-class mission. The future European X-ray
observatory will study the hot and energetic Universe with its launch foreseen
in 2028. Microcalorimeters based on superconducting Transition-edge sensor
(TES) are the chosen technology for the detectors array of the X-ray Integral
Field Unit (X-IFU) on board of Athena. The X-IFU is a 2-D imaging
integral-field spectrometer operating in the soft X-ray band (0.3 -12 keV). The
detector consists of an array of 3840 TESs coupled to X-ray absorbers and read
out in the MHz bandwidth using Frequency Domain Multiplexing (FDM) based on
Superconducting QUantum Interference Devices (SQUIDs). The proposed design
calls for devices with a high filling-factor, high quantum efficiency,
relatively high count-rate capability and an energy resolution of 2.5 eV at 5.9
keV. The paper will review the basic principle and the physics of the TES-based
microcalorimeters and present the state-of-the art of the FDM read-out.
[7]
oai:arXiv.org:1604.00553 [pdf] - 1384861
Development of TES-based detectors array for the X-ray Integral Field
Unit (X-IFU) on the future x-ray observatory ATHENA
Gottardi, Luciano;
Akamatsu, Hiroki;
Barret, Didier;
Bruijn, Marcel P.;
Hartog, Roland H. den;
Herder, Jan-Willem den;
Hoevers, Henk F. C.;
Kiviranta, Mikko;
van der Kuur, Jan;
van der Linden, Anton J.;
Jackson, Brian D.;
Jambunathan, Madu;
Ridder, Marcel L.
Submitted: 2016-04-02
We are developing transition-edge sensor (TES)-based microcalorimeters for
the X-ray Integral Field Unit (XIFU) of the future European X-Ray Observatory
Athena. The microcalorimeters are based on TiAu TESs coupled to 250{\mu}m
squared, AuBi absorbers. We designed and fabricated devices with different
contact geometries between the absorber and the TES to optimise the detector
performance and with different wiring topology to mitigate the self-magnetic
field. The design is tailored to optimise the performance under Frequency
Domain Multiplexing. In this paper we review the main design feature of the
pixels array and we report on the performance of the 18 channels, 2-5MHz
frequency domain multiplexer that will be used to characterised the detector
array.