[1]  oai:arXiv.org:2003.11899  [pdf] - 2070581
Progress in the development of frequency domain multiplexing for the X-ray Integral Field Unit on board the Athena mission
Comments: 7 pages, 5 figures. Published on Journal of Low Temperature Physics (2020)
Submitted: 2020-03-26
Frequency domain multiplexing (FDM) is the baseline readout system for the X-ray Integral Field Unit (X-IFU) on board the Athena mission. Under the FDM scheme, TESs are coupled to a passive LC filter and biased with alternating current (AC bias) at MHz frequencies. Using high-quality factor LC filters and room temperature electronics developed at SRON and low-noise two-stage SQUID amplifiers provided by VTT, we have recently demonstrated good performance with the FDM readout of Mo/Au TES calorimeters with Au/Bi absorbers. We have achieved a performance requested for the demonstration model (DM) with the single pixel AC bias ($\Delta E=$1.8 eV) and 9 pixel multiplexing ($\Delta E=$2.6 eV) modes. We have also demonstrated 14-pixel multiplexing with an average energy resolution of 3.3 eV, which is limited by non-fundamental issues related to FDM readout in our lab setup.
[2]  oai:arXiv.org:1810.09122  [pdf] - 1770848
Two SQUID amplifiers intended to alleviate the summing node inductance problem in multiplexed arrays of Transition Edge Sensors
Comments: 6 pages, 7 figures
Submitted: 2018-10-22
Frequency Domain Multiplexed detector arrays constructed of superconducting Transition Edge Sensors in the current-summing configuration suffer from the finite impedance of the summing node which should ideally be zero. We suggest two circuits to alleviate the effect. The first circuit uses a capacitive resonant transformer to increase the voltages and decrease the currents of TES signals to overcome the parasitic inductance of the interconnections. On the SQUID chip impedance transform to the opposite direction takes place. The second circuit implements a power combiner having a better branch-to-branch isolation than a simple T-junction. Two SQUID devices have been designed and fabricated for a proof-of-principle demonstration of the circuits.
[3]  oai:arXiv.org:1810.04706  [pdf] - 1764927
Low-dissipating push-pull SQUID amplifier for TES detector readout
Comments: 4 pages, 6 figures
Submitted: 2018-10-10
We suggest SQUID amplifier configuration intended for millikelvin refrigerators where cooling power is limited and hence high power efficiency is desirable. The configuration operates the SQUIDs in class-AB rather than the traditional class-A. A proof-of principle demonstration at T = 4.2 K is presented.
[4]  oai:arXiv.org:1611.05268  [pdf] - 1515839
Optimising the multiplex factor of the frequency domain multiplexed readout of the TES-based microcalorimeter imaging array for the X-IFU instrument on the Athena Xray observatory
Comments:
Submitted: 2016-11-16
Athena is a space-based X-ray observatory intended for exploration of the hot and energetic universe. One of the science instruments on Athena will be the X-ray Integrated Field Unit (X-IFU), which is a cryogenic X-ray spectrometer, based on a large cryogenic imaging array of Transition Edge Sensors (TES) based microcalorimeters operating at a temperature of 100mK. The imaging array consists of 3800 pixels providing 2.5 eV spectral resolution, and covers a field of view with a diameter of of 5 arc minutes. Multiplexed readout of the cryogenic microcalorimeter array is essential to comply with the cooling power and complexity constraints on a space craft. Frequency domain multiplexing has been under development for the readout of TES-based detectors for this purpose, not only for the X-IFU detector arrays but also for TES-based bolometer arrays for the Safari instrument of the Japanese SPICA observatory. This paper discusses the design considerations which are applicable to optimise the multiplex factor within the boundary conditions as set by the space craft. More specifically, the interplay between the science requirements such as pixel dynamic range, pixel speed, and cross talk, and the space craft requirements such as the power dissipation budget, available bandwidth, and electromagnetic compatibility will be discussed.
[5]  oai:arXiv.org:1611.00956  [pdf] - 1521434
Development of frequency domain multiplexing for the X-ray Integral Field Unit (X-IFU) on the Athena
Comments: 8 pages, 4 figures, Proceedings of the SPIE Astronomical Instrumentation "Space Telescopes and Instrumentation 2014: Ultraviolet to Gamma Ray"
Submitted: 2016-11-03
We are developing the frequency domain multiplexing (FDM) read-out of transition-edge sensor (TES) microcalorimeters for the X-ray Integral Field Unit (X-IFU) instrument on board of the future European X-Ray observatory Athena. The X-IFU instrument consists of an array of $\sim$3840 TESs with a high quantum efficiency ($>$90 \%) and spectral resolution $\Delta E$=2.5 eV $@$ 7 keV ($E/\Delta E\sim$2800). FDM is currently the baseline readout system for the X-IFU instrument. Using high quality factor LC filters and room temperature electronics developed at SRON and low-noise two stage SQUID amplifiers provided by VTT, we have recently demonstrated good performance with the FDM readout of Mo/Au TES calorimeters with Au/Bi absorbers. An integrated noise equivalent power resolution of about 2.0 eV at 1.7 MHz has been demonstrated with a pixel from a new TES array from NASA/Goddard (GSFC-A2). We have achieved X-ray energy resolutions $\sim$2.5 eV at AC bias frequency at 1.7 MHz in the single pixel read-out. We have also demonstrated for the first time an X-ray energy resolution around 3.0 eV in a 6 pixel FDM read-out with TES array (GSFC-A1). In this paper we report on the single pixel performance of these microcalorimeters under MHz AC bias, and further results of the performance of these pixels under FDM.
[6]  oai:arXiv.org:1604.00670  [pdf] - 1489757
Development of the superconducting detectors and read-out for the X-IFU instrument on board of the X-ray observatory Athena
Comments: 4 pages,4 figures, available on line (http://www.sciencedirect.com/science/article/pii/S0168900215011274)
Submitted: 2016-04-03
The Advanced Telescope for High-Energy Astrophysics (Athena) has been selected by ESA as its second large-class mission. The future European X-ray observatory will study the hot and energetic Universe with its launch foreseen in 2028. Microcalorimeters based on superconducting Transition-edge sensor (TES) are the chosen technology for the detectors array of the X-ray Integral Field Unit (X-IFU) on board of Athena. The X-IFU is a 2-D imaging integral-field spectrometer operating in the soft X-ray band (0.3 -12 keV). The detector consists of an array of 3840 TESs coupled to X-ray absorbers and read out in the MHz bandwidth using Frequency Domain Multiplexing (FDM) based on Superconducting QUantum Interference Devices (SQUIDs). The proposed design calls for devices with a high filling-factor, high quantum efficiency, relatively high count-rate capability and an energy resolution of 2.5 eV at 5.9 keV. The paper will review the basic principle and the physics of the TES-based microcalorimeters and present the state-of-the art of the FDM read-out.
[7]  oai:arXiv.org:1604.00553  [pdf] - 1384861
Development of TES-based detectors array for the X-ray Integral Field Unit (X-IFU) on the future x-ray observatory ATHENA
Comments: 9 pages, 8 figures
Submitted: 2016-04-02
We are developing transition-edge sensor (TES)-based microcalorimeters for the X-ray Integral Field Unit (XIFU) of the future European X-Ray Observatory Athena. The microcalorimeters are based on TiAu TESs coupled to 250{\mu}m squared, AuBi absorbers. We designed and fabricated devices with different contact geometries between the absorber and the TES to optimise the detector performance and with different wiring topology to mitigate the self-magnetic field. The design is tailored to optimise the performance under Frequency Domain Multiplexing. In this paper we review the main design feature of the pixels array and we report on the performance of the 18 channels, 2-5MHz frequency domain multiplexer that will be used to characterised the detector array.