Normalized to: Kitamura, H.
[1]
oai:arXiv.org:1712.01757 [pdf] - 1598372
Energy Calibration of CALET Onboard the International Space Station
Asaoka, Y.;
Akaike, Y.;
Komiya, Y.;
Miyata, R.;
Torii, S.;
Adriani, O.;
Asano, K.;
Bagliesi, M. G.;
Bigongiari, G.;
Binns, W. R.;
Bonechi, S.;
Bongi, M.;
Brogi, P.;
Buckley, J. H.;
Cannady, N.;
Castellini, G.;
Checchia, C.;
Cherry, M. L.;
Collazuol, G.;
Di Felice, V.;
Ebisawa, K.;
Fuke, H.;
Guzik, T. G.;
Hams, T.;
Hareyama, M.;
Hasebe, N.;
Hibino, K.;
Ichimura, M.;
Ioka, K.;
Ishizaki, W.;
Israel, M. H.;
Javaid, A.;
Kasahara, K.;
Kataoka, J.;
Kataoka, R.;
Katayose, Y.;
Kato, C.;
Kawanaka, N.;
Kawakubo, Y.;
Kitamura, H.;
Krawczynski, H. S.;
Krizmanic, J. F.;
Kuramata, S.;
Lomtadze, T.;
Maestro, P.;
Marrocchesi, P. S.;
Messineo, A. M.;
Mitchell, J. W.;
Miyake, S.;
Mizutani, K.;
Moiseev, A. A.;
Mori, K.;
Mori, M.;
Mori, N.;
Motz, H. M.;
Munakata, K.;
Murakami, H.;
Nakagawa, Y. E.;
Nakahira, S.;
Nishimura, J.;
Okuno, S.;
Ormes, J. F.;
Ozawa, S.;
Pacini, L.;
Palma, F.;
Papini, P.;
Penacchioni, A. V.;
Rauch, B. F.;
Ricciarini, S.;
Sakai, K.;
Sakamoto, T.;
Sasaki, M.;
Shimizu, Y.;
Shiomi, A.;
Sparvoli, R.;
Spillantini, P.;
Stolzi, F.;
Takahashi, I.;
Takayanagi, M.;
Takita, M.;
Tamura, T.;
Tateyama, N.;
Terasawa, T.;
Tomida, H.;
Tsunesada, Y.;
Uchihori, Y.;
Ueno, S.;
Vannuccini, E.;
Wefel, J. P.;
Yamaoka, K.;
Yanagita, S.;
Yoshida, A.;
Yoshida, K.;
Yuda, T.
Submitted: 2017-12-05
In August 2015, the CALorimetric Electron Telescope (CALET), designed for
long exposure observations of high energy cosmic rays, docked with the
International Space Station (ISS) and shortly thereafter began tocollect data.
CALET will measure the cosmic ray electron spectrum over the energy range of 1
GeV to 20 TeV with a very high resolution of 2% above 100 GeV, based on a
dedicated instrument incorporating an exceptionally thick 30 radiation-length
calorimeter with both total absorption and imaging (TASC and IMC) units. Each
TASC readout channel must be carefully calibrated over the extremely wide
dynamic range of CALET that spans six orders of magnitude in order to obtain a
degree of calibration accuracy matching the resolution of energy measurements.
These calibrations consist of calculating the conversion factors between ADC
units and energy deposits, ensuring linearity over each gain range, and
providing a seamless transition between neighboring gain ranges. This paper
describes these calibration methods in detail, along with the resulting data
and associated accuracies. The results presented in this paper show that a
sufficient accuracy was achieved for the calibrations of each channel in order
to obtain a suitable resolution over the entire dynamic range of the electron
spectrum measurement.
[2]
oai:arXiv.org:1607.00233 [pdf] - 1490766
CALET Upper Limits on X-ray and Gamma-ray Counterparts of GW 151226
Adriani, O.;
Akaike, Y.;
Asano, K.;
Asaoka, Y.;
Bagliesi, M. G.;
Bigongiari, G.;
Binns, W. R.;
Bonechi, S.;
Bongi, M.;
Brog, P.;
Buckley, J. H.;
Cannady, N.;
Castellini, G.;
Checchia, C.;
Cherry, M. L.;
Collazuol, G.;
Di Felice, V.;
Ebisawa, K.;
Fuke, H.;
Guzik, T. G.;
Hams, T.;
Hareyama, M.;
Hasebe, N.;
Hibino, K.;
Ichimura, M.;
Ioka, K.;
Ishizaki, W.;
Israel, M. H.;
Javaid, A.;
Kasahara, K.;
Kataoka, J.;
Kataoka, R.;
Katayose, Y.;
Kato, C.;
Kawanaka, N.;
Kawakubo, Y.;
Kitamura, H.;
Krawczynski, H. S.;
Krizmanic, J. F.;
Kuramata, S.;
Lomtadze, T.;
Maestro, P.;
Marrocchesi, P. S.;
Messineo, A. M.;
Mitchell, J. W.;
Miyake, S.;
Mizutani, K.;
Moiseev, A. A.;
Mori, K.;
Mori, M.;
Mori, N.;
Motz, H. M.;
Munakata, K.;
Murakami, H.;
Nakagawa, Y. E.;
Nakahira, S.;
Nishimura, J.;
Okuno, S.;
Ormes, J. F.;
Ozawa, S.;
Pacini, L.;
Palma, F.;
Papini, P.;
Penacchioni, A. V.;
Rauch, B. F.;
Ricciarini, S.;
Sakai, K.;
Sakamoto, T.;
Sasaki, M.;
Shimizu, Y.;
Shiomi, A.;
Sparvoli, R.;
Spillantini, P.;
Stolzi, F.;
Takahashi, I.;
Takayanagi, M.;
Takita, M.;
Tamura, T.;
Tateyama, N.;
Terasawa, T.;
Tomida, H.;
Torii, S.;
Tsunesada, Y.;
Uchihori, Y.;
Ueno, S.;
Vannuccini, E.;
Wefel, J. P.;
Yamaoka, K.;
Yanagita, S.;
Yoshida, A.;
Yoshida, K.;
Yuda, T.
Submitted: 2016-07-01, last modified: 2016-09-02
We present upper limits in the hard X-ray and gamma-ray bands at the time of
the LIGO gravitational-wave event GW 151226 derived from the CALorimetric
Electron Telescope (CALET) observation. The main instrument of CALET,
CALorimeter (CAL), observes gamma-rays from ~1 GeV up to 10 TeV with a field of
view of ~2 sr. The CALET gamma-ray burst monitor (CGBM) views ~3 sr and ~2pi sr
of the sky in the 7 keV - 1 MeV and the 40 keV - 20 MeV bands, respectively, by
using two different scintillator-based instruments. The CGBM covered 32.5% and
49.1% of the GW 151226 sky localization probability in the 7 keV - 1 MeV and 40
keV - 20 MeV bands respectively. We place a 90% upper limit of 2 x 10^{-7} erg
cm-2 s-1 in the 1 - 100 GeV band where CAL reaches 15% of the integrated LIGO
probability (~1.1 sr). The CGBM 7 sigma upper limits are 1.0 x 10^{-6} erg cm-2
s-1 (7-500 keV) and 1.8 x 10^{-6} erg cm-2 s-1 (50-1000 keV) for one second
exposure. Those upper limits correspond to the luminosity of 3-5 x 10^{49} erg
s-1 which is significantly lower than typical short GRBs.
[3]
oai:arXiv.org:1508.01921 [pdf] - 1264200
Final Evolution and Delayed Explosions of Spinning White Dwarfs in
Single Degenerate Models for Type Ia Supernovae
Submitted: 2015-08-08
We study the occurrence of delayed SNe~Ia in the single degenerate (SD)
scenario. We assume that a massive carbon-oxygen (CO) white dwarf (WD) accretes
matter coming from a companion star, making it to spin at the critical rate. We
assume uniform rotation due to magnetic field coupling. The carbon ignition
mass for non-rotating WDs is M_{ig}^{NR} \approx 1.38 M_{\odot}; while for the
case of uniformly rotating WDs it is a few percent larger (M_{ig}^{R} \approx
1.43 M_{\odot}). When accretion rate decreases, the WD begins to lose angular
momentum, shrinks, and spins up; however, it does not overflow its critical
rotation rate, avoiding mass shedding. Thus, angular momentum losses can lead
the CO WD interior to compression and carbon ignition, which would induce an
SN~Ia. The delay, largely due to the angular momentum losses timescale, may be
large enough to allow the companion star to evolve to a He WD, becoming
undetectable at the moment of explosion. This scenario supports the occurrence
of delayed SNe~Ia if the final CO WD mass is 1.38 M_{\odot} < M < 1.43
M_{\odot}. We also find that if the delay is longer than ~3 Gyr, the WD would
become too cold to explode, rather undergoing collapse.
[4]
oai:arXiv.org:1307.3221 [pdf] - 691775
Single event effect characterization of the mixed-signal ASIC developed
for CCD camera in space use
Nakajima, Hiroshi;
Fujikawa, Mari;
Mori, Hideki;
Kan, Hiroaki;
Ueda, Shutaro;
Kosugi, Hiroko;
Anabuki, Naohisa;
Hayashida, Kiyoshi;
Tsunemi, Hiroshi;
Doty, John P.;
Ikeda, Hirokazu;
Kitamura, Hisashi;
Uchihori, Yukio
Submitted: 2013-07-11
We present the single event effect (SEE) tolerance of a mixed-signal
application-specific integrated circuit (ASIC) developed for a charge-coupled
device camera onboard a future X-ray astronomical mission. We adopted proton
and heavy ion beams at HIMAC/NIRS in Japan. The particles with high linear
energy transfer (LET) of 57.9 MeV cm^{2}/mg is used to measure the single event
latch-up (SEL) tolerance, which results in a sufficiently low cross-section of
sigma_{SEL} < 4.2x10^{-11} cm^{2}/(IonxASIC). The single event upset (SEU)
tolerance is estimated with various kinds of species with wide range of energy.
Taking into account that a part of the protons creates recoiled heavy ions that
has higher LET than that of the incident protons, we derived the probability of
SEU event as a function of LET. Then the SEE event rate in a low-earth orbit is
estimated considering a simulation result of LET spectrum. SEL rate is below
once per 49 years, which satisfies the required latch-up tolerance. The upper
limit of the SEU rate is derived to be 1.3x10^{-3}events/sec. Although the SEU
events cannot be distinguished from the signals of X-ray photons from
astronomical objects, the derived SEU rate is below 1.3% of expected non-X-ray
background rate of the detector and hence these events should not be a major
component of the instrumental background.
[5]
oai:arXiv.org:1102.2472 [pdf] - 317830
Development of the analog ASIC for multi-channel readout X-ray CCD
camera
Nakajima, Hiroshi;
Matsuura, Daisuke;
Idehara, Toshihiro;
Anabuki, Naohisa;
Tsunemi, Hiroshi;
Doty, John P.;
Ikeda, Hirokazu;
Katayama, Haruyoshi;
Kitamura, Hisashi;
Uchihori, Yukio
Submitted: 2011-02-11
We report on the performance of an analog application-specific integrated
circuit (ASIC) developed aiming for the front-end electronics of the X-ray
CCDcamera system onboard the next X-ray astronomical satellite, ASTRO-H. It has
four identical channels that simultaneously process the CCD signals.
Distinctive capability of analog-to-digital conversion enables us to construct
a CCD camera body that outputs only digital signals. As the result of the
front-end electronics test, it works properly with low input noise of =<30 uV
at the pixel rate below 100 kHz. The power consumption is sufficiently low of
about 150 mW/chip. The input signal range of 720 mV covers the effective energy
range of the typical X-ray photon counting CCD (up to 20 keV). The integrated
non-linearity is 0.2% that is similar as those of the conventional CCDs in
orbit. We also performed a radiation tolerance test against the total ionizing
dose (TID) effect and the single event effect. The irradiation test using 60Co
and proton beam showed that the ASIC has the sufficient tolerance against TID
up to 200 krad, which absolutely exceeds the expected amount of dose during the
period of operating in a low-inclination low-earth orbit. The irradiation of Fe
ions with the fluence of 5.2x10^8 Ion/cm2 resulted in no single event latchup
(SEL), although there were some possible single event upsets. The threshold
against SEL is higher than 1.68 MeV cm^2/mg, which is sufficiently high enough
that the SEL event should not be one of major causes of instrument downtime in
orbit.
[6]
oai:arXiv.org:0809.0760 [pdf] - 15967
High-energy electron observations by PPB-BETS flight in Antarctica
Torii, S.;
Yamagami, T.;
Tamura, T.;
Yoshida, K.;
Kitamura, H.;
Anraku, K.;
Chang, J.;
Ejiri, M.;
Iijima, I.;
Kadokura, A.;
Kasahara, K.;
Katayose, Y.;
Kobayashi, T.;
Komori, Y.;
Matsuzaka, Y.;
Mizutani, K.;
Murakami, H.;
Namiki, M.;
Nishimura, J.;
Ohta, S.;
Saito, Y.;
Shibata, M.;
Tateyama, N.;
Yamagishi, H.;
Yamashita, T.;
Yuda, T.
Submitted: 2008-09-04
We have observed cosmic-ray electrons from 10 GeV to 800 GeV by a long
duration balloon flight using Polar Patrol Balloon (PPB) in Antarctica. The
observation was carried out for 13 days at an average altitude of 35 km in
January 2004. The detector is an imaging calorimeter composed of
scintillating-fiber belts and plastic scintillators inserted between lead
plates with 9 radiation lengths. The performance of the detector has been
confirmed by the CERN-SPS beam test and also investigated by Monte-Carlo
simulations. New telemetry system using a commercial satellite of Iridium,
power supply by solar batteries, and automatic level control using CPU have
successfully been developed and operated during the flight. From the long
duration balloon observations, we derived the energy spectrum of cosmic-ray
electrons in the energy range from 100 GeV to 800 GeV. In addition, for the
first time we derived the electron arrival directions above 100 GeV, which is
consistent with the isotropic distribution.
[7]
oai:arXiv.org:0707.3328 [pdf] - 3335
The Design of Diamond Compton Telescope
Submitted: 2007-07-23
We have developed radiation detectors using the new synthetic diamonds. The
diamond detector has an advantage for observations of "low/medium" energy gamma
rays as a Compton telescope. The primary advantage of the diamond detector can
reduce the photoelectric effect in the low energy range, which is background
noise for tracking of the Compton recoil electron. A concept of the Diamond
Compton Telescope (DCT) consists of position sensitive layers of
diamond-striped detector and calorimeter layer of CdTe detector. The key part
of the DCT is diamond-striped detectors with a higher positional resolution and
a wider energy range from 10 keV to 10 MeV. However, the diamond-striped
detector is under development. We describe the performance of prototype diamond
detector and the design of a possible DCT evaluated by Monte Carlo simulations.
[8]
oai:arXiv.org:astro-ph/9807045 [pdf] - 1235241
The Anisotropy of Cosmic Ray Arrival Directions around 10$^{18}$eV
AGASA Collaboration;
Hayashida, N.;
Honda, K.;
Inoue, N.;
Kadota, K.;
Kakimoto, F.;
Kamata, K.;
Kawaguchi, S.;
Kawasaki, Y.;
Kawasumi, N.;
Kitamura, H.;
Kusano, E.;
Matsubara, Y.;
Murakami, K.;
Nagano, M.;
Nishikawa, D.;
Ohoka, H.;
Sakaki, N.;
Sasaki, M.;
Shinozaki, K.;
Souma, N.;
Takeda, M.;
Teshima, M.;
Torii, R.;
Tsushima, I.;
Uchihori, Y.;
Yamamoto, T.;
Yoshida, S.;
Yoshii, H.
Submitted: 1998-07-04, last modified: 1999-05-15
Anisotropy in the arrival directions of cosmic rays with energies above
10$^{17}$eV is studied using data from the Akeno 20 km$^2$ array and the Akeno
Giant Air Shower Array (AGASA), using a total of about 117,000 showers observed
during 11 years. In the first harmonic analysis, we have found strong
anisotropy of $\sim$ 4% around 10$^{18}$eV, corresponding to a chance
probability of 0.2%. With two dimensional analysis in right ascension and
declination, this anisotropy is interpreted as an excess of showers near the
directions of the Galactic Center and the Cygnus region.
[9]
oai:arXiv.org:astro-ph/9807193 [pdf] - 102187
Extension of the Cosmic-Ray Energy Spectrum Beyond the Predicted
Greisen-Zatsepin-Kuz'min Cutoff
Takeda, M.;
Hayashida, N.;
Honda, K.;
Inoue, N.;
Kadota, K.;
Kakimoto, F.;
Kamata, K.;
Kawaguchi, S.;
Kawasaki, Y.;
Kawasumi, N.;
Kitamura, H.;
Kusano, E.;
Matsubara, Y.;
Murakami, K.;
Nagano, M.;
Nishikawa, D.;
Ohoka, H.;
Sakaki, N.;
Sasaki, M.;
Shinozaki, K.;
Souma, N.;
Teshima, M.;
Torii, R.;
Tsushima, I.;
Uchihori, Y.;
Yamamoto, T.;
Yoshida, S.;
Yoshii, H.
Submitted: 1998-07-18
The cosmic-ray energy spectrum above 10^{18.5} eV is reported using the
updated data set of the Akeno Giant Air Shower Array (AGASA) from February 1990
to October 1997. The energy spectrum extends beyond 10^{20} eV and the energy
gap between the highest energy event and the others is being filled up with
recently observed events. The spectral shape suggests the absence of the 2.7 K
cutoff in the energy spectrum or a possible presence of a new component beyond
the 2.7 K cutoff.
[10]
oai:arXiv.org:astro-ph/9706079 [pdf] - 97600
The Detection of TeV Gamma Rays from Crab using the Telescope Array
Prototype
Aiso, S.;
Chikawa, M.;
Hayashi, Y.;
Hayashida, N.;
Hibino, K.;
Hirasawa, H.;
Honda, K.;
Hotta, N.;
Inoue, N.;
Ishikawa, F.;
Ito, N.;
Kabe, S.;
Kajino, F.;
Kashiwagi, T.;
Kawakami, S.;
Kawasaki, Y.;
Kawasumi, N.;
Kitamura, H.;
Kuramochi, K.;
Kurata, K.;
Kusano, E.;
Lafoux, H.;
Loh, E. C.;
Matsubara, Y.;
Matsuyama, T.;
Mizumoto, Y.;
Mizutani, K.;
Nagano, M.;
Nishikawa, D.;
Nishimura, J.;
Nishizawa, M.;
Ouchi, T.;
Ohoka, H.;
Ohnishi, M.;
Saito, To.;
Sakaki, N.;
Sakata, M.;
Sakumoto, K.;
Sasaki, M.;
Sasano, M.;
Shimodaira, H.;
Shiomi, A.;
Sokolsky, P.;
Sugiyama, T.;
Takahashi, T.;
Taylor, S.;
Teshima, M.;
Tsushima, I.;
Uchihori, Y.;
Yamamoto, T.;
Yamamoto, Y.;
Yoshida, S.;
Yoshii, H.;
Yuda, T.
Submitted: 1997-06-08
The Telescope Array prototype detectors were installed at Akeno Observatory
and at the Utah Fly's Eye site. Using these detectors, we have observed the
Crab Nebula and AGN's since the end of 1995. The successful detections of TeV
gamma rays from Crab Nebula and Mkn501 are reported.