Normalized to: Kissel, S.
[1]
oai:arXiv.org:1911.09270 [pdf] - 2001968
An optical test bench for the precision characterization of absolute
quantum efficiency for the TESS CCD detectors
Submitted: 2019-11-20
The Transiting Exoplanet Survey Satellite (TESS) will search for planets
transiting bright stars with Ic<13. TESS has been selected by NASA for launch
in 2018 as an Astrophysics Explorer mission, and is expected to discover a
thousand or more planets that are smaller in size than Neptune. TESS will
employ four wide-field optical charge-coupled device (CCD) cameras with a
band-pass of 650 nm-1050 nm to detect temporary drops in brightness of stars
due to planetary transits. The 1050 nm limit is set by the quantum efficiency
(QE) of the CCDs. The detector assembly consists of four back-illuminated MIT
Lincoln Laboratory CCID-80 devices. Each CCID-80 device consists of 2048x2048
imaging array and 2048x2048 frame store regions. Very precise on-ground
calibration and characterization of CCD detectors will significantly assist in
the analysis of the science data obtained in space. The characterization of the
absolute QE of the CCD detectors is a crucial part of the characterization
process because QE affects the performance of the CCD significantly over the
redder wavelengths at which TESS will be operating. An optical test bench with
significantly high photometric stability has been developed to perform precise
QE measurements. The design of the test setup along with key hardware,
methodology, and results from the test campaign are presented.
[2]
oai:arXiv.org:1309.6665 [pdf] - 740122
The REgolith X-Ray Imaging Spectrometer (REXIS) for OSIRIS-REx:
Identifying Regional Elemental Enrichment on Asteroids
Allen, Branden;
Grindlay, Jonathan;
Hong, Jaesub;
Binzel, Richard P.;
Masterson, Rebecca;
Inamdar, Niraj K.;
Chodas, Mark;
Smith, Matthew W.;
Bautz, Marshall W.;
Kissel, Steven E.;
Villasenor, Joel;
Oprescu, Miruna;
Induni, Nicholas
Submitted: 2013-09-25
The OSIRIS-REx Mission was selected under the NASA New Frontiers program and
is scheduled for launch in September of 2016 for a rendezvous with, and
collection of a sample from the surface of asteroid Bennu in 2019. 101955 Bennu
(previously 1999 RQ36) is an Apollo (near-Earth) asteroid originally discovered
by the LINEAR project in 1999 which has since been classified as a potentially
hazardous near-Earth object. The REgolith X-Ray Imaging Spectrometer (REXIS)
was proposed jointly by MIT and Harvard and was subsequently accepted as a
student led instrument for the determination of the elemental composition of
the asteroid's surface as well as the surface distribution of select elements
through solar induced X-ray fluorescence. REXIS consists of a detector plane
that contains 4 X-ray CCDs integrated into a wide field coded aperture
telescope with a focal length of 20 cm for the detection of regions with
enhanced abundance in key elements at 50 m scales. Elemental surface
distributions of approximately 50-200 m scales can be detected using the
instrument as a simple collimator. An overview of the observation strategy of
the REXIS instrument and expected performance are presented here.
[3]
oai:arXiv.org:0810.0873 [pdf] - 1000970
New CTI Correction Method for the Spaced-Row Charge Injection of the
Suzaku X-Ray Imaging Spectrometer
Uchiyama, Hideki;
Ozawa, Midori;
Matsumoto, Hironori;
Tsuru, Takeshi Go;
Koyama, Katsuji;
Kimura, Masashi;
Uchida, Hiroyuki;
Nakajima, Hiroshi;
Hayashida, Kiyoshi;
Tsunemi, Hiroshi;
Mori, Hideyuki;
Bamba, Aya;
Ozaki, Masanobu;
Dotani, Tadayasu;
Takei, Dai;
Murakami, Hiroshi;
Mori, Koji;
Ishisaki, Yoshitaka;
Kohmura, Takayoshi;
Prigozhin, Gregory;
Kissel, Steve;
Miller, Eric;
LaMarr, Beverly;
Bautz, Marshall
Submitted: 2008-10-06
The charge transfer inefficiency (CTI) of the X-ray CCDs on board the Suzaku
satellite (X-ray Imaging Spectrometers; XIS) has increased since the launch due
to radiation damage, and the energy resolution has been degraded. To improve
the CTI, we have applied a spaced-row charge injection (SCI) technique to the
XIS in orbit; by injecting charges into CCD rows periodically, the CTI is
actively decreased. The CTI in the SCI mode depends on the distance between a
signal charge and a preceding injected row, and the pulse height shows periodic
positional variations. Using in-flight data of onboard calibration sources and
of the strong iron line from the Perseus cluster of galaxies, we studied the
variation in detail. We developed a new method to correct the variation. By
applying the new method, the energy resolution (FWHM) at 5.9 keV at March 2008
is ~155 eV for the front-illuminated CCDs and ~175 eV for the back-illuminated
CCD.
[4]
oai:arXiv.org:0809.3665 [pdf] - 16568
Energy-Scale Calibration of the Suzaku X-Ray Imaging Spectrometer Using
the Checker Flag Charge Injection Technique in Orbit
Ozawa, Midori;
Uchiyama, Hideki;
Matsumoto, Hironori;
Nakajima, Hiroshi;
Koyama, Katsuji;
Tsuru, Takeshi Go;
Uchino, Masahiro;
Uchida, Hiroyuki;
Hayashida, Kiyoshi;
Tsunemi, Hiroshi;
Mori, Hideyuki;
Bamba, Aya;
Ozaki, Masanobu;
Dotani, Tadayasu;
Kohmura, Takayoshi;
Ishisaki, Yoshitaka;
Murakami, Hiroshi;
Kato, Takeshi;
Kitazono, Takeshi;
Kimura, Yuki;
Ogawa, Kazuki;
Kawai, Shunsuke;
Mori, Koji;
Prigozhin, Gregory;
Kissel, Steve;
Miller, Eric;
LaMarr, Beverly;
Bautz, Marshall
Submitted: 2008-09-22
The X-ray Imaging Spectrometer (XIS) on board the Suzaku satellite is an
X-ray CCD camera system that has superior performance such as a low background,
high quantum efficiency, and good energy resolution in the 0.2-12 keV band.
Because of the radiation damage in orbit, however, the charge transfer
inefficiency (CTI) has increased, and hence the energy scale and resolution of
the XIS has been degraded since the launch of July 2005. The CCD has a charge
injection structure, and the CTI of each column and the pulse-height dependence
of the CTI are precisely measured by a checker flag charge injection (CFCI)
technique. Our precise CTI correction improved the energy resolution from 230
eV to 190 eV at 5.9 keV in December 2006. This paper reports the CTI
measurements with the CFCI experiments in orbit. Using the CFCI results, we
have implemented the time-dependent energy scale and resolution to the Suzaku
calibration database.
[5]
oai:arXiv.org:0807.1721 [pdf] - 14403
Physics of reverse annealing in high-resistivity Chandra ACIS CCDs
Submitted: 2008-07-10
After launch, the Advanced CCD Imaging Spectrometer (ACIS), a focal plane
instrument on the Chandra X-ray Observatory, suffered radiation damage from
exposure to soft protons during passages through the Earth's radiation belts.
An effect of the damage was to increase the charge transfer inefficiency (CTI)
of the front illuminated CCDs. As part of the initial damage assessment, the
focal plane was warmed from the operating temperature of -100C to +30C which
unexpectedly further increased the CTI. We report results of ACIS CCD
irradiation experiments in the lab aimed at better understanding this reverse
annealing process. Six CCDs were irradiated cold by protons ranging in energy
from 100 keV to 400 keV, and then subjected to simulated bakeouts in one of
three annealing cycles. We present results of these lab experiments, compare
them to our previous experiences on the ground and in flight, and derive limits
on the annealing time constants.
[6]
oai:arXiv.org:0705.1771 [pdf] - 1529986
Performance of the Charge Injection Capability of Suzaku XIS
Nakajima, H.;
Yamaguchi, H.;
Matsumoto, H.;
Tsuru, T. G.;
Koyama, K.;
Tsunemi, H.;
Hayashida, K.;
Torii, K.;
Namiki, M.;
Katsuda, S.;
Shoji, M.;
Matsuura, D.;
Miyauchi, T.;
Dotani, T.;
Ozaki, M.;
Murakami, H.;
Bautz, M. W.;
Kissel, S. E.;
LaMarr, B.;
Prigozhin, G. Y.
Submitted: 2007-05-12
A charge injection technique is applied to the X-ray CCD camera, XIS (X-ray
Imaging Spectrometer) onboard Suzaku. The charge transfer inefficiency (CTI) in
each CCD column (vertical transfer channel) is measured by the injection of
charge packets into a transfer channel and subsequent readout. This paper
reports the performances of the charge injection capability based on the ground
experiments using a radiation damaged device, and in-orbit measurements of the
XIS. The ground experiments show that charges are stably injected with the
dispersion of 91eV in FWHM in a specific column for the charges equivalent to
the X-ray energy of 5.1keV. This dispersion width is significantly smaller than
that of the X-ray events of 113eV (FWHM) at approximately the same energy. The
amount of charge loss during transfer in a specific column, which is measured
with the charge injection capability, is consistent with that measured with the
calibration source. These results indicate that the charge injection technique
can accurately measure column-dependent charge losses rather than the
calibration sources. The column-to-column CTI correction to the calibration
source spectra significantly reduces the line widths compared to those with a
column-averaged CTI correction (from 193eV to 173eV in FWHM on an average at
the time of one year after the launch). In addition, this method significantly
reduces the low energy tail in the line profile of the calibration source
spectrum.
[7]
oai:arXiv.org:astro-ph/0609310 [pdf] - 1233870
Discoveries of Diffuse Iron Line Sources from the Sgr B Region
Koyama, Katsuji;
Inui, Tatsuya;
Hyodo, Yoshiaki;
Matsumoto, Hironori;
Tsuru, Takeshi Go;
Maeda, Yoshitomo;
Murakami, Hiroshi;
Yamauchi, Shigeo;
Kissel, Steven E.;
Kai-Wing;
Soong, Chan Yang
Submitted: 2006-09-12
The radio complex Sgr B region is observed with the X-Ray Imaging
Spectrometers (XIS) on board Suzaku. This region exhibits diffuse iron lines at
6.4, 6.7 and 6.9 keV, which are K$\alpha$ lines of Fe \emissiontype{I} (neutral
iron), Fe\emissiontype{XXV} (He-like iron) and Fe\emissiontype{XXVI} (H-like
iron), respectively. The high energy resolving power of the XIS provides the
separate maps of the K-shell transition lines from Fe\emissiontype{I} (6.4 keV)
and Fe\emissiontype{XXV} (6.7 keV). Although the 6.7 keV line is smoothly
distributed over the Sgr B region, a local excess is found near at $(l, b) =
(\timeform {0D.61}, \timeform{0D.01})$, possibly a new SNR. The plasma
temperature is \textit{kT} $\sim$3 keV and the age is estimated to be around
several$\times10^{3}$ years. The 6.4 keV image is clumpy with local excesses
nearby Sgr B2 and at $(l, b) = (\timeform{0D.74}, -\timeform{0D.09})$. Like Sgr
B2, this excess may be another candidate of an X-ray reflection nebula (XRN).
[8]
oai:arXiv.org:astro-ph/0607659 [pdf] - 316459
Cyclotron resonance energies at a low X-ray luminosity: A0535+262
observed with Suzaku
Terada, Y.;
Mihara, T.;
Nakajima, M.;
Suzuki, M.;
Isobe, N.;
Makishima, K.;
Takahashi, H.;
Enoto, T.;
Kokubun, M.;
Kitaguchi, T.;
Naik, S.;
Dotani, T.;
Nagase, F.;
Tanaka, T.;
Watanabe, S.;
Kitamoto, S.;
Sudoh, K.;
Yoshida, A.;
Nakagawa, Y.;
Sugita, S.;
Kohmura, T.;
Kotani, T.;
Yonetoku, D.;
Angelini, L.;
Cottam, J.;
Mukai, K.;
Kelley, R.;
Soong, Y.;
Bautz, M.;
Kissel, S.;
Doty, J.
Submitted: 2006-07-29
The binary X-ray pulsar A0535+262 was observed with the Suzaku X-ray
observatory, on 2005 September 14 for a net exposure of 22 ksec. The source was
in a declining phase of a minor outburst, exhibiting 3--50 keV luminosity of
about $3.7 \times 10^{35}$ ergs s$^{-1}$ at an assumed distance of 2 kpc. In
spite of the very low source intensity (about 30 mCrab at 20 keV), its electron
cyclotron resonance was detected clearly with the Suzaku Hard X-ray Detector,
in absorption at about 45 keV. The resonance energy is found to be essentially
the same as those measured when the source is almost two orders of magnitude
more luminous. These results are compared with the luminosity-dependent changes
in the cyclotron resonance energy, observed from 4U 0115+63 and X 0331+53.
[9]
oai:arXiv.org:astro-ph/0606178 [pdf] - 82618
Temperature dependence of charge transfer inefficiency in Chandra X-ray
CCDs
Submitted: 2006-06-07
Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the
focal plane instruments on the Chandra X-ray Observatory, suffered radiation
damage from exposure to soft protons during passages through the Earth's
radiation belts. The primary effect of the damage was to increase the charge
transfer inefficiency (CTI) of the eight front illuminated CCDs by more than
two orders of magnitude. The ACIS instrument team is continuing to study the
properties of the damage with an emphasis on developing techniques to mitigate
CTI and spectral resolution degradation. We present the initial temperature
dependence of ACIS CTI from -120 to -60 degrees Celsius and the current
temperature dependence after more than six years of continuing slow radiation
damage. We use the change of shape of the temperature dependence to speculate
on the nature of the damaging particles.
[10]
oai:arXiv.org:astro-ph/0509035 [pdf] - 75617
Long-term trends in radiation damage of Chandra X-ray CCDs
Submitted: 2005-09-01
Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the
focal plane instruments on the Chandra X-ray Observatory, suffered radiation
damage from exposure to soft protons during passages through the Earth's
radiation belts. Current operations require ACIS to be protected during
radiation belt passages to prevent this type of damage, but there remains a
much slower and more gradual increase. We present the history of ACIS charge
transfer inefficiency (CTI), and other measures of radiation damage, from
January 2000 through June 2005. The rate of CTI increase is low, of order 1e-6
per year, with no indication of step-function increases due to specific solar
events. Based on the time history and CCD location of the CTI increase, we
speculate on the nature of the damaging particles.
[11]
oai:arXiv.org:astro-ph/0407199 [pdf] - 66041
A charge transfer inefficiency correction model for the Chandra Advanced
CCD Imaging Spectrometer
Submitted: 2004-07-09
Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the
focal plane instruments on the Chandra X-ray Observatory, suffered radiation
damage from exposure to soft protons during passages through the Earth's
radiation belts. The primary effect of the damage was to increase the charge
transfer inefficiency (CTI) of the eight front illuminated CCDs by more than
two orders of magnitude. The ACIS instrument team is continuing to study the
properties of the damage with an emphasis on developing techniques to mitigate
CTI and spectral resolution degradation. We will discuss the characteristics of
the damage, the detector and the particle background and how they conspire to
degrade the instrument performance. We have developed a model for ACIS CTI
which can be used to correct each event and regain some of the lost
performance. The correction uses a map of the electron trap distribution, a
parameterization of the energy dependent charge loss and the fraction of the
lost charge re-emitted into the trailing pixel to correct the pixels in the
event island. This model has been implemented in the standard Chandra data
processing pipeline. Some of the correction algorithm was inspired by the
earlier work on ACIS CTI correction by Townsley et al. (2000; 2002). The
details of the CTI model and how each parameter improves performance will be
discussed, as well as the limitations and the possibilities for future
improvement.