Normalized to: Kishimoto, T.
[1]
oai:arXiv.org:1703.07600 [pdf] - 1564143
Imaging Polarimeter for a Sub-MeV Gamma-Ray All-Sky Survey using an
Electron-Tracking Compton Camera
Komura, Shotaro;
Takada, Atsushi;
Mizumura, Yoshitaka;
Miyamoto, Shohei;
Takemura, Taito;
Kishimoto, Tetsuro;
Kubo, Hidetoshi;
Kurosawa, Shunsuke;
Matsuoka, Yoshihiro;
Miuchi, Kentaro;
Mizumoto, Tetsuya;
Nakamasu, Yuma;
Nakamura, Kiseki;
Oda, Makoto;
Parker, Joseph D.;
Sawano, Tatsuya;
Sonoda, Shinya;
Tanimori, Toru;
Tomono, Dai;
Yoshikawa, Kei
Submitted: 2017-03-22
X-ray and gamma-ray polarimetry is a promising tool to study the geometry and
the magnetic configuration of various celestial objects, such as binary black
holes or gamma-ray bursts (GRBs). However, statistically significant
polarizations have been detected in few of the brightest objects. Even though
future polarimeters using X-ray telescopes are expected to observe weak
persistent sources, there are no effective approaches to survey transient and
serendipitous sources with a wide field of view (FoV). Here we present an
electron-tracking Compton camera (ETCC) as a highly-sensitive gamma-ray imaging
polarimeter. The ETCC provides powerful background rejection and a high
modulation factor over a FoV of up to 2$\pi$ sr thanks to its excellent imaging
based on a well-defined point spread function. Importantly, we demonstrated for
the first time the stability of the modulation factor under realistic
conditions of off-axis incidence and huge backgrounds using the SPring-8
polarized X-ray beam. The measured modulation factor of the ETCC was 0.65 $\pm$
0.01 at 150 keV for an off-axis incidence with an oblique angle of 30$^\circ$
and was not degraded compared to the 0.58 $\pm$ 0.02 at 130 keV for on-axis
incidence. These measured results are consistent with the simulation results.
Consequently, we found that the satellite-ETCC proposed in Tanimori et al.
(2015) would provide all-sky surveys of weak persistent sources of 13 mCrab
with 10% polarization for a 10$^{7}$ s exposure and over 20 GRBs down to a
$6\times10^{-6}$ erg cm$^{-2}$ fluence and 10% polarization during a one-year
observation.
[2]
oai:arXiv.org:1702.01483 [pdf] - 1535425
Establishment of Imaging Spectroscopy of Nuclear Gamma-Rays based on
Geometrical Optics
Tanimori, Toru;
Mizumura, Yoshitaka;
Takada, Atsushi;
Miyamoto, Shohei;
Takemura, Taito;
Kishimoto, Tetsuro;
Komura, Shotaro;
Kubo, Hidetoshi;
Kurosawa, Shunsuke;
Matsuoka, Yoshihiro;
Miuchi, Kentaro;
Mizumoto, Tetsuya;
Nakamasu, Yuma;
Nakamura, Kiseki;
Parker, Joseph D.;
Sawano, Tatsuya;
Sonoda, Shinya;
Tomono, Dai;
Yoshikawa, Kei
Submitted: 2017-02-05
Since the discovery of nuclear gamma-rays, its imaging has been limited to
pseudo imaging, such as Compton Camera (CC) and coded mask. Pseudo imaging does
not keep physical information (intensity, or brightness in Optics) along a ray,
and thus is capable of no more than qualitative imaging of bright objects. To
attain quantitative imaging, cameras that realize geometrical optics is
essential, which would be, for nuclear MeV gammas, only possible via complete
reconstruction of the Compton process. Recently we have revealed that "Electron
Tracking Compton Camera" (ETCC) provides a well-defined Point Spread Function
(PSF). The information of an incoming gamma is kept along a ray with the PSF
and that is equivalent to geometrical optics. Here we present an
imaging-spectroscopic measurement with the ETCC. Our results highlight the
intrinsic difficulty with CCs in performing accurate imaging, and show that the
ETCC surmounts this problem. The imaging capability also helps the ETCC
suppress the noise level dramatically by ~3 orders of magnitude without a
shielding structure. Furthermore, full reconstruction of Compton process with
the ETCC provides spectra free of Compton edges. These results mark the first
proper imaging of nuclear gammas based on the genuine geometrical optics.
[3]
oai:arXiv.org:1508.00990 [pdf] - 1268655
New readout and data-acquisition system in an electron-tracking Compton
camera for MeV gamma-ray astronomy (SMILE-II)
Mizumoto, Tetsuya;
Matsuoka, Yoshihiro;
Mizumura, Yoshitaka;
Tanimori, Toru;
Kubo, Hidetoshi;
Takada, Atsushi;
Iwaki, Satoru;
Sawano, Tatsuya;
Nakamura, Kiseki;
Komura, Shotaro;
Nakamura, Shogo;
Kishimoto, Tetsuro;
Oda, Makoto;
Miyamoto, Shohei;
Takemura, Taito;
Parker, Joseph D.;
Tomono, Dai;
Sonoda, Shinya;
Miuchi, Kentaro;
Kurosawa, Shunsuke
Submitted: 2015-08-05, last modified: 2015-08-29
For MeV gamma-ray astronomy, we have developed an electron-tracking Compton
camera (ETCC) as a MeV gamma-ray telescope capable of rejecting the radiation
background and attaining the high sensitivity of near 1 mCrab in space. Our
ETCC comprises a gaseous time-projection chamber (TPC) with a micro pattern gas
detector for tracking recoil electrons and a position-sensitive scintillation
camera for detecting scattered gamma rays. After the success of a first balloon
experiment in 2006 with a small ETCC (using a 10$\times$10$\times$15 cm$^3$
TPC) for measuring diffuse cosmic and atmospheric sub-MeV gamma rays (Sub-MeV
gamma-ray Imaging Loaded-on-balloon Experiment I; SMILE-I), a (30 cm)$^{3}$
medium-sized ETCC was developed to measure MeV gamma-ray spectra from celestial
sources, such as the Crab Nebula, with single-day balloon flights (SMILE-II).
To achieve this goal, a 100-times-larger detection area compared with that of
SMILE-I is required without changing the weight or power consumption of the
detector system. In addition, the event rate is also expected to dramatically
increase during observation. Here, we describe both the concept and the
performance of the new data-acquisition system with this (30 cm)$^{3}$ ETCC to
manage 100 times more data while satisfying the severe restrictions regarding
the weight and power consumption imposed by a balloon-borne observation. In
particular, to improve the detection efficiency of the fine tracks in the TPC
from $\sim$10\% to $\sim$100\%, we introduce a new data-handling algorithm in
the TPC. Therefore, for efficient management of such large amounts of data, we
developed a data-acquisition system with parallel data flow.
[4]
oai:arXiv.org:1412.3918 [pdf] - 1223621
Performance of a new electron-tracking Compton camera under intense
radiations from a water target irradiated with a proton beam
Matsuoka, Yoshihiro;
Tanimori, T.;
Kubo, H.;
Takada, A.;
Parker, J. D.;
Mizumoto, T.;
Mizumura, Y.;
Iwaki, S.;
Sawano, T.;
Komura, S.;
Kishimoto, T.;
Oda, M.;
Takemura, T.;
Miyamoto, S.;
Sonoda, S.;
Tomono, D.;
Miuchi, K.;
Kabuki, S.;
Kurosawa, S.
Submitted: 2014-12-12, last modified: 2015-01-22
We have developed an electron-tracking Compton camera (ETCC) for use in
next-generation MeV gamma ray telescopes. An ETCC consists of a gaseous time
projection chamber (TPC) and pixel scintillator arrays (PSAs). Since the TPC
measures the three dimensional tracks of Compton-recoil electrons, the ETCC can
completely reconstruct the incident gamma rays. Moreover, the ETCC demonstrates
efficient background rejection power in Compton-kinematics tests, identifies
particle from the energy deposit rate (dE/dX) registered in the TPC, and
provides high quality imaging by completely reconstructing the Compton
scattering process. We are planning the "Sub-MeV gamma ray Imaging
Loaded-on-balloon Experiment" (SMILE) for our proposed all-sky survey
satellite. Performance tests of a mid-sized 30 cm-cubic ETCC, constructed for
observing the Crab nebula, are ongoing. However, observations at balloon
altitudes or satellite orbits are obstructed by radiation background from the
atmosphere and the detector itself. The background rejection power was checked
using proton accelerator experiments conducted at the Research Center for
Nuclear Physics, Osaka University. To create the intense radiation fields
encountered in space, which comprise gamma rays, neutrons, protons, and other
energetic entities, we irradiated a water target with a 140 MeV proton beam and
placed a SMILE-II ETCC near the target. In this situation, the counting rate
was five times than that expected at the balloon altitude. Nonetheless, the
ETCC stably operated and identified particles sufficiently to obtain a clear
gamma ray image of the checking source. Here, we report the performance of our
detector and demonstrate its effective background rejection based in electron
tracking experiments.
[6]
oai:arXiv.org:1307.4565 [pdf] - 1937883
The Cherenkov Telescope Array Large Size Telescope
Ambrosi, G.;
Awane, Y.;
Baba, H.;
Bamba, A.;
Barceló, M.;
de Almeida, U. Barres;
Barrio, J. A.;
Bigas, O. Blanch;
Boix, J.;
Brunetti, L.;
Carmona, E.;
Chabanne, E.;
Chikawa, M.;
Colin, P.;
Conteras, J. L.;
Cortina, J.;
Dazzi, F.;
Deangelis, A.;
Deleglise, G.;
Delgado, C.;
Díaz, C.;
Dubois, F.;
Fiasson, A.;
Fink, D.;
Fouque, N.;
Freixas, L.;
Fruck, C.;
Gadola, A.;
García, R.;
Gascon, D.;
Geffroy, N.;
Giglietto, N.;
Giordano, F.;
Grañena, F.;
Gunji, S.;
Hagiwara, R.;
Hamer, N.;
Hanabata, Y.;
Hassan, T.;
Hatanaka, K.;
Haubold, T.;
Hayashida, M.;
Hermel, R.;
Herranz, D.;
Hirotani, K.;
Inoue, S.;
Inoue, Y.;
Ioka, K.;
Jablonski, C.;
Kagaya, M.;
Katagiri, H.;
Kishimoto, T.;
Kodani, K.;
Kohri, K.;
Konno, Y.;
Koyama, S.;
Kubo, H.;
Kushida, J.;
Lamanna, G.;
Flour, T. Le;
López-Moya, M.;
López, R.;
Lorenz, E.;
Majumdar, P.;
Manalaysay, A.;
Mariotti, M.;
Martínez, G.;
Martínez, M.;
Mazin, D.;
Miranda, J. M.;
Mirzoyan, R.;
Monteiro, I.;
Moralejo, A.;
Murase, K.;
Nagataki, S.;
Nakajima, D.;
Nakamori, T.;
Nishijima, K.;
Noda, K.;
Nozato, A.;
Ohira, Y.;
Ohishi, M.;
Ohoka, H.;
Okumura, A.;
Orito, R.;
Panazol, J. L.;
Paneque, D.;
Paoletti, R.;
Paredes, J. M.;
Pauletta, G.;
Podkladkin, S.;
Prast, J.;
Rando, R.;
Reimann, O.;
Ribó, M.;
Rosier-Lees, S.;
Saito, K.;
Saito, T.;
Saito, Y.;
Sakaki, N.;
Sakonaka, R.;
Sanuy, A.;
Sasaki, H.;
Sawada, M.;
Scalzotto, V.;
Schultz, S.;
Schweizer, T.;
Shibata, T.;
Shu, S.;
Sieiro, J.;
Stamatescu, V.;
Steiner, S.;
Straumann, U.;
Sugawara, R.;
Tajima, H.;
Takami, H.;
Tanaka, S.;
Tanaka, M.;
Tejedor, L. A.;
Terada, Y.;
Teshima, M.;
Totani, T.;
Ueno, H.;
Umehara, K.;
Vollhardt, A.;
Wagner, R.;
Wetteskind, H.;
Yamamoto, T.;
Yamazaki, R.;
Yoshida, A.;
Yoshida, T.;
Yoshikoshi, T.
Submitted: 2013-07-17
The two arrays of the Very High Energy gamma-ray observatory Cherenkov
Telescope Array (CTA) will include four Large Size Telescopes (LSTs) each with
a 23 m diameter dish and 28 m focal distance. These telescopes will enable CTA
to achieve a low-energy threshold of 20 GeV, which is critical for important
studies in astrophysics, astroparticle physics and cosmology. This work
presents the key specifications and performance of the current LST design in
the light of the CTA scientific objectives.
[7]
oai:arXiv.org:1307.3386 [pdf] - 1937869
Development of the Photomultiplier-Tube Readout System for the CTA Large
Size Telescope
Kubo, H.;
Paoletti, R.;
Awane, Y.;
Bamba, A.;
Barcelo, M.;
Barrio, J. A.;
Blanch, O.;
Boix, J.;
Delgado, C.;
Fink, D.;
Gascon, D.;
Gunji, S.;
Hagiwara, R.;
Hanabata, Y.;
Hatanaka, K.;
Hayashida, M.;
Ikeno, M.;
Kabuki, S.;
Katagiri, H.;
Kataoka, J.;
Konno, Y.;
Koyama, S.;
Kishimoto, T.;
Kushida, J.;
Martinez, G.;
Masuda, S.;
Miranda, J. M.;
Mirzoyan, R.;
Mizuno, T.;
Nagayoshi, T.;
Nakajima, D.;
Nakamori, T.;
Ohoka, H.;
Okumura, A.;
Orito, R.;
Saito, T.;
Sanuy, A.;
Sasaki, H.;
Sawada, M.;
Schweizer, T.;
Sugawara, R.;
Sulanke, K. -H.;
Tajima, H.;
Tanaka, M.;
Tanaka, S.;
Tejedor, L. A.;
Terada, Y.;
Teshima, M.;
Tokanai, F.;
Tsuchiya, Y.;
Uchida, T.;
Ueno, H.;
Umehara, K.;
Yamamoto, T.
Submitted: 2013-07-12
We have developed a prototype of the photomultiplier tube (PMT) readout
system for the Cherenkov Telescope Array (CTA) Large Size Telescope (LST). Two
thousand PMTs along with their readout systems are arranged on the focal plane
of each telescope, with one readout system per 7-PMT cluster. The Cherenkov
light pulses generated by the air showers are detected by the PMTs and
amplified in a compact, low noise and wide dynamic range gain block. The output
of this block is then digitized at a sampling rate of the order of GHz using
the Domino Ring Sampler DRS4, an analog memory ASIC developed at Paul Scherrer
Institute. The sampler has 1,024 capacitors per channel and four channels are
cascaded for increased depth. After a trigger is generated in the system, the
charges stored in the capacitors are digitized by an external slow sampling ADC
and then transmitted via Gigabit Ethernet. An onboard FPGA controls the DRS4,
trigger threshold, and Ethernet transfer. In addition, the control and
monitoring of the Cockcroft-Walton circuit that provides high voltage for the
7-PMT cluster are performed by the same FPGA. A prototype named Dragon has been
developed that has successfully sampled PMT signals at a rate of 2 GHz, and
generated single photoelectron spectra.