Normalized to: Kirsch, M.
[1]
oai:arXiv.org:1602.08756 [pdf] - 1392884
Revealing the broad iron Kalpha line in Cygnus X-1 through simultaneous
XMM-Newton, RXTE, and INTEGRAL observations
Duro, Refiz;
Dauser, Thomas;
Grinberg, Victoria;
Miškovičová, Ivica;
Rodriguez, Jérôme;
Tomsick, John;
Hanke, Manfred;
Pottschmidt, Katja;
Nowak, Michael A.;
Kreykenbohm, Sonja;
Bel, Marion Cadolle;
Bodaghee, Arash;
Lohfink, Anne;
Reynolds, Christopher S.;
Kendziorra, Eckhard;
Kirsch, Marcus G. F.;
Staubert, Rüdiger;
Wilms, Jörn
Submitted: 2016-02-28
We report on the analysis of the broad Fe Kalpha line feature of Cygnus X-1
in the spectra of four simultaneous hard intermediate state observations made
with the X-ray Multiple Mirror mission (XMM-Newton), the Rossi X-ray Timing
Explorer (RXTE), and the International Gamma-Ray Astrophysics Laboratory
(INTEGRAL). The high quality of the XMM-Newton data taken in the Modified
Timing Mode of the EPIC-pn camera provides a great opportunity to investigate
the broadened Fe Kalpha reflection line at 6.4keV with a very high signal to
noise ratio. The 4-500keV energy range is used to constrain the underlying
continuum and the reflection at higher energies. We first investigate the data
by applying a phenomenological model that consists of the sum of an
exponentially cutoff power law and relativistically smeared reflection.
Additionally, we apply a more physical approach and model the irradiation of
the accretion disk directly from the lamp post geometry. All four observations
show consistent values for the black hole parameters with a spin of $a\sim
0.9$, in agreement with recent measurements from reflection and disk continuum
fitting. The inclination is found to be $i\sim30^\circ$, consistent with the
orbital inclination and different from inclination measurements made during the
soft state, which show a higher inclination. We speculate that the difference
between the inclination measurements is due to changes in the inner region of
the accretion disk.
[2]
oai:arXiv.org:1204.0978 [pdf] - 1117770
The relative and absolute timing accuracy of the EPIC-pn camera on
XMM-Newton, from X-ray pulsations of the Crab and other pulsars
Martin-Carrillo, A.;
Kirsch, M. G. F.;
Caballero, I.;
Freyberg, M. J.;
Ibarra, A.;
Kendziorra, E.;
Lammers, U.;
Mukerjee, K.;
Schönherr, G.;
Stuhlinger, M.;
Saxton, R. D.;
Staubert, R.;
Suchy, S.;
Wellbrock, A.;
Webb, N.;
Guainazzi, M.
Submitted: 2012-04-04
Reliable timing calibration is essential for the accurate comparison of
XMM-Newton light curves with those from other observatories, to ultimately use
them to derive precise physical quantities. The XMM-Newton timing calibration
is based on pulsar analysis. However, as pulsars show both timing noise and
glitches, it is essential to monitor these calibration sources regularly. To
this end, the XMM-Newton observatory performs observations twice a year of the
Crab pulsar to monitor the absolute timing accuracy of the EPIC-pn camera in
the fast Timing and Burst modes. We present the results of this monitoring
campaign, comparing XMM-Newton data from the Crab pulsar (PSR B0531+21) with
radio measurements. In addition, we use five pulsars (PSR J0537-69, PSR
B0540-69, PSR B0833-45, PSR B1509-58 and PSR B1055-52) with periods ranging
from 16 ms to 197 ms to verify the relative timing accuracy. We analysed 38
XMM-Newton observations (0.2-12.0 keV) of the Crab taken over the first ten
years of the mission and 13 observations from the five complementary pulsars.
All the data were processed with the SAS, the XMM-Newton Scientific Analysis
Software, version 9.0. Epoch folding techniques coupled with \chi^{2} tests
were used to derive relative timing accuracies. The absolute timing accuracy
was determined using the Crab data and comparing the time shift between the
main X-ray and radio peaks in the phase folded light curves. The relative
timing accuracy of XMM-Newton is found to be better than 10^{-8}. The strongest
X-ray pulse peak precedes the corresponding radio peak by 306\pm9 \mus, which
is in agreement with other high energy observatories such as Chandra, INTEGRAL
and RXTE. The derived absolute timing accuracy from our analysis is \pm48 \mus.
[3]
oai:arXiv.org:1108.1157 [pdf] - 1083221
The broad iron Kalpha line of Cygnus X-1 as seen by XMM-Newton in the
EPIC-pn modified timing mode
Duro, R.;
Dauser, T.;
Wilms, J.;
Pottschmidt, K.;
Nowak, M. A.;
Fritz, S.;
Kendziorra, E.;
Kirsch, M. G. F.;
Reynolds, C. S.;
Staubert, R.
Submitted: 2011-08-04
We present the analysis of the broadened, flourescent iron Kalpha line in
simultaneous XMM-Newton and RXTE data from the black hole Cygnus X-1. The
XMM-Newton data were taken in a modified version of the timing mode of the
EPIC-pn camera. In this mode the lower energy threshold of the instrument is
increased to 2.8 keV to avoid telemetry drop outs due to the brightness of the
source, while at the same time preserving the signal-to-noise ratio in the Fe
Kalpha band. We find that the best-fit spectrum consists of the sum of an
exponentially cut off power-law and relativistically smeared, ionized
reflection. The shape of the broadened Fe Kalpha feature is due to strong
Compton broadening combined with relativistic broadening. Assuming a standard,
thin accretion disk, the black hole is close to rotating maximally.
[4]
oai:arXiv.org:0903.3392 [pdf] - 1001691
Thermal emission, shock modification, and X-ray emitting ejecta in SN
1006
Submitted: 2009-03-19
Efficient particle acceleration can modify the structure of supernova
remnants. In this context we present the results of the combined analysis of
the XMM-Newton EPIC archive observations of SN 1006. We aim at describing the
spatial distribution of the physical and chemical properties of the X-ray
emitting plasma at the shock front. We investigate the contribution of thermal
and non-thermal emission to the X-ray spectrum at the rim of the remnant to
study how the acceleration processes affect the X-ray emitting plasma. We
perform a spatially resolved spectral analysis on a set of regions covering the
whole rim of the shell and we exploit the results of the spectral analysis to
produce a count-rate image of the "pure" thermal emission of SN 1006 in the
0.5-0.8 keV energy band (subtracting the non-thermal contribution). This image
significantly differs from the total image in the same band, specially near the
bright limbs. We find that thermal X-ray emission can be associated with the
ejecta and we study the azimuthal variation of their physical and chemical
properties finding anisotropies in temperature and chemical composition. Thanks
to our thermal image we trace the position of the contact discontinuity over
the whole shell and we compare it with that expected from 3-D MHD models of
SNRs with unmodified shock. We conclude that the shock is modified everywhere
in the rim and that the aspect angle between the interstellar magnetic field
and the line of sight is significantly lower than 90 degrees
[5]
oai:arXiv.org:0811.2319 [pdf] - 18533
Aspect angle for interstellar magnetic field in SN 1006
Submitted: 2008-11-14
A number of important processes taking place around strong shocks in
supernova remnants (SNRs) depend on the shock obliquity. The measured
synchrotron flux is a function of the aspect angle between interstellar
magnetic field (ISMF) and the line of sight. Thus a model of non-thermal
emission from SNRs should account for the orientation of the ambient magnetic
field. We develop a new method for the estimation of the aspect angle, based on
the comparison between observed and synthesized radio maps of SNRs, making
different assumptions about the dependence of electron injection efficiency on
the shock obliquity. The method uses the azimuthal profile of radio surface
brightness as a probe for orientation of ambient magnetic field because it is
almost insensitive to the downstream distribution of magnetic field and
emitting electrons. We apply our method to a new radio image of SN 1006
produced on the basis of archival VLA and Parkes data. The image recovers
emission from all spatial structures with angular scales from few arcseconds to
15 arcmin. We explore different models of injection efficiency and find the
following best-fitting values for the aspect angle of SN 1006: phi=70 +/- 4.2
deg if the injection is isotropic, phi=64 +/- 2.8 deg for quasi-perpendicular
injection (SNR has an equatorial belt in both cases) and phi=11 +/- 0.8 deg for
quasi-parallel injection (polar-cap model of SNR). In the last case, SN 1006 is
expected to have a centrally-peaked morphology contrary to what is observed.
Therefore, our analysis provides some indication against the quasi-parallel
injection model.
[6]
oai:arXiv.org:0712.1451 [pdf] - 7930
X-ray Timing Analysis of Six Pulsars Using ESA's XMM-Newton Observatory
Submitted: 2007-12-10
We present results of a timing analysis of various isolated pulsars using
ESA's \emph{XMM-Newton} observatory. Isolated pulsars are useful for
calibration purposes because of their stable emission. We have analyzed six
pulsars with different pulse profiles in a range of periods between 15 and 200
ms. All observations were made using the \emph{EPIC-pn camera} in its faster
modes (Small window, Timing and Burst modes). We investigate the relative
timing accuracy of the camera by comparing the pulse periods determined from
the \emph{EPIC-pn camera} observations with those from radio observations. As a
result of our analysis we conclude that the relative timing accuracy of the
\emph{EPIC-pn camera} is of the order of $1\times 10^{-8}$.
[7]
oai:arXiv.org:0706.2137 [pdf] - 2227
The broadband spectrum of Cygnus X-1
Submitted: 2007-06-14
The Black Hole (BH) binary Cygnus X-1 has been observed simultaneously by
INTEGRAL, RXTE, and XMM-Newton for four times in November and December 2004,
when Cyg X-1 became first observable with XMM-Newton. During these observations
the source was found in one of its transitional states between the hard state
and the soft state. We obtained a high signal to noise spectrum of Cyg X-1 from
3 keV to 1 MeV which allows us to put constraints on the nature of the
Comptonizing plasma by modeling the continuum with Comptonization models as
eqpair (Coppi 1992). Using XMM-Newton we were also able to confirm the presence
of a relativistically broadened Fe K-alpha line.
[8]
oai:arXiv.org:astro-ph/0604097 [pdf] - 81166
The XMM-Newton view of the Crab
Kirsch, M. G. F.;
Schoenherr, G.;
Kendziorra, E.;
Freyberg, M. J.;
Martin, M.;
Wilms, J.;
Mukerjee, K.;
Breitfellner, M. G.;
Smith, M. J. S.;
Staubert, R.
Submitted: 2006-04-05
We discuss the current X-ray view of the Crab Nebula and Pulsar, summarising
our analysis of observations of the source with the EPIC-pn camera on board the
XMM-Newton observatory. Different modes of EPIC-pn were combined in order to
yield a complete scenario of the spectral properties of the Crab resolved in
space and time (pulse phase). In addition we give a description of the special
EPIC-pn Burst mode and guidance for data reduction in that mode.
We analysed spectra for the nebula and pulsar separately in the 0.6-12.0 keV
energy band. All data were processed with the SAS 6.0.0 XMM-Newton Scientific
Analysis System package; models were fitted to the data with XSPEC 11. The high
time resolution of EPIC-pn in its Burst mode (7 micros) was used for a phase
resolved analysis of the pulsar spectrum, after determination of the period
with epoch folding techniques. Data from the Small Window mode were processed
and corrected for pile-up allowing for spectroscopy simultaneously resolved in
space and time.
The spatial variation of the spectrum over the entire region of the Crab
shows a gradual spectral softening from the inner pulsar region to the outer
nebula region with a variation in photon index, Gamma, from 2.0 to 2.4. Pulse
phase resolved spectroscopy of the Crab Pulsar reveals a phase dependent
modulation of the photon index in form of a significant hardening of the
spectrum in the inter-peak phase from Gamma =1.7 during the pulse peak to Gamma
=1.5.
[9]
oai:arXiv.org:astro-ph/0511395 [pdf] - 77753
Status of the XMM-Newton cross-calibration with SASv6.5.0
Stuhlinger, M.;
Altieri, B.;
Baskill, D.;
Dennerl, K.;
Esquej, M. P.;
Freyberg, M.;
Haberl, F.;
Herder, J. W. den;
Kaastra, J.;
Kirsch, M. G. F.;
Metcalfe, L.;
Pollock, A. M. T.;
Read, A. M.;
Saxton, R. D.;
Sembay, S.;
Smith, M. J. S.;
Talavera, A.;
Vink, J.;
de Vries, C.
Submitted: 2005-11-14
Further achievements of the XMM-Newton cross-calibration - XMM internal as
well as with other X-ray missions - are presented. We explain the major changes
in the new version SASv6.5 of the XMM-Newton science analysis system. The
current status of the cross-calibration of the three EPIC cameras is shown.
Using a large sample of blazars, the pn energy redistribution at low energy
could be further calibrated, correcting the overestimation of fluxes in the
lowest energy regime. In the central CCDs of the MOSs, patches were identified
at the bore-sight positions, leading to an underestimation of the low energy
fluxes. The further improvement in the understanding of the cameras resulted in
a good agreement of the EPIC instruments down to lowest energies. The latest
release of the SAS software package already includes corrections for both
effects as shown in several examples of different types of sources. Finally the
XMM internal cross-calibration is completed by the presentation of the current
cross-calibration status between EPIC and RGS instruments. Major efforts have
been made in cross-calibrations with other X-ray missions, most importantly
with Chandra, of course, but also with currently observing satellites like
Swift.
[10]
oai:arXiv.org:astro-ph/0407257 [pdf] - 66099
XMM-Newton (cross)-calibration
Kirsch, M. G. F.;
Altieri, B.;
Chen, B.;
Haberl, F.;
Metcalfe, L.;
Pollock, A. M. T.;
Read, A. M.;
Saxton, R. D.;
Sembay, S.;
Smith, M. J. S.
Submitted: 2004-07-13
ESA's large X-ray space observatory XMM-Newton is in its fifth year of
operations. We give a general overview of the status of calibration of the five
X-ray instruments and the Optical Monitor. A main point of interest in the last
year became the cross-calibration between the instruments. A cross-calibration
campaign started at the XMM-Newton Science Operation Centre at the European
Space Astronomy Centre in collaboration with the Instrument Principle
Investigators provides a first systematic comparison of the X-ray instruments
EPIC and RGS for various kind of sources making also an initial assessment in
cross calibration with other X-ray observatories.
[11]
oai:arXiv.org:astro-ph/0407017 [pdf] - 65859
Studies of orbital parameters and pulse profile of the accreting
millisecond pulsar XTE J1807-294
Submitted: 2004-07-01
The accreting millisecond pulsar XTE J1807-294 was observed by XMM-Newton on
March 22, 2003 after its discovery on February 21, 2003 by RXTE. The source was
detected in its bright phase with an observed average count rate of 33.3 cts/s
in the EPIC-pn camera in the 0.5-10 keV energy band (3.7 mCrab). Using the
earlier established best-fit orbital period of 40.0741+/-0.0005 minutes from
RXTE observations and considering a circular binary orbit as first
approximation, we derived a value of 4.8+/-0.1 lt-ms for the projected orbital
radius of the binary system and an epoch of the orbital phase of MJD
52720.67415(16). The barycentric mean spin period of the pulsar was derived as
5.2459427+/-0.0000004 ms. The pulsar's spin-pulse profile showed a prominent
(1.5 ms FWHM) pulse, with energy and orbital phase dependence in the amplitude
and shape. The measured pulsed fraction in four energy bands was found to be
3.1+/-0.2 % (0.5-3.0 keV), 5.4+/-0.4 % (3.0-6.0 keV), 5.1+/-0.7 % (6.0-10.0
keV) and 3.7+/-0.2 % (0.5-10.0 keV), respectively. Studies of spin-profiles
with orbital phase and energy showed significant increase in its pulsed
fraction during the second observed orbit of the neutron star, gradually
declining in the subsequent two orbits, which was associated with sudden but
marginal increase in mass accretion. From our investigations of orbital
parameters and estimation of other properties of this compact binary system, we
conclude that XTE J1807-294 is very likely a candidate for a millisecond radio
pulsar.
[12]
oai:arXiv.org:astro-ph/0403647 [pdf] - 1468635
In-orbit Vignetting Calibrations of XMM-Newton Telescopes
Submitted: 2004-03-29
We describe measurements of the mirror vignetting in the XMM-Newton
Observatory made in-orbit, using observations of SNR G21.5-09 and SNR
3C58 with the EPIC imaging cameras. The instrument features that complicate
these measurements are briefly described. We show the spatial and energy
dependences of measured vignetting, outlining assumptions made in deriving the
eventual agreement between simulation and measurement. Alternate methods to
confirm these are described, including an assessment of source elongation with
off-axis angle, the surface brightness distribution of the diffuse X-ray
background, and the consistency of Coma cluster emission at different position
angles. A synthesis of these measurements leads to a change in the XMM
calibration data base, for the optical axis of two of the three telescopes, by
in excess of 1 arcminute. This has a small but measureable effect on the
assumed spectral responses of the cameras for on-axis targets.
[13]
oai:arXiv.org:astro-ph/0011438 [pdf] - 39445
The first broad-band X-ray images and spectra of the 30 Doradus region
in the LMC
Dennerl, K.;
Haberl, F.;
Aschenbach, B.;
Briel, U. G.;
Balasini, M.;
Braeuninger, H.;
Burkert, W.;
Hartmann, R.;
Hartner, G.;
Hasinger, G.;
Kemmer, J.;
Kendziorra, E.;
Kirsch, M.;
Krause, N.;
Kuster, M.;
Lumb, D.;
Massa, P.;
Meidinger, N.;
Pfeffermann, E.;
Pietsch, W.;
Reppin, C.;
Soltau, H.;
Staubert, R.;
Strueder, L.;
Truemper, J.;
Turner, M.;
Villa, G.;
Zavlin, V. E.
Submitted: 2000-11-23
We present the XMM-Newton first light image, taken in January 2000 with the
EPIC pn camera during the instrument's commissioning phase, when XMM-Newton was
pointing towards the Large Magellanic Cloud (LMC). The field is rich in
different kinds of X-ray sources: point sources, supernova remnants (SNRs) and
diffuse X-ray emission from LMC interstellar gas. The observations are of
unprecedented sensitivity, reaching a few 10^32 erg/s for point sources in the
LMC. We describe how these data sets were analysed and discuss some of the
spectroscopic results. For the SNR N157B the power law spectrum is clearly
steeper than previously determined from ROSAT and ASCA data. The existence of a
significant thermal component is evident and suggests that N157B is not a
Crab-like but a composite SNR. Most puzzling is the spectrum of the LMC hot
interstellar medium, which indicates a significant overabundance of Ne and Mg