sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Kirsch, Christian

Normalized to: Kirsch, C.

2 article(s) in total. 108 co-authors, from 1 to 2 common article(s). Median position in authors list is 51,5.

[1]  oai:arXiv.org:1908.00781  [pdf] - 1966924
SIXTE -- The Generic X-ray Instrument Simulation Toolkit
Comments: accepted for publication in A&A
Submitted: 2019-08-02, last modified: 2019-08-08
We give an overview of the SImulation of X-ray TElescopes (SIXTE) software package, a generic, mission-independent Monte Carlo simulation toolkit for X-ray astronomical instrumentation. The package is based on a modular approach for the source definition, the description of the optics, and the detector type such that new missions can be easily implemented. The targets to be simulated are stored in a flexible input format called SIMPUT. Based on this source definition, a sample of photons is produced and then propagated through the optics. In order to model the detection process, the software toolkit contains modules for various detector types, ranging from proportional counter and Si-based detectors, to more complex descriptions like transition edge sensor (TES) devices. The implementation of characteristic detector effects and a detailed modeling of the read-out process allow for representative simulations and therefore enable the analysis of characteristic features, such as for example pile-up, and their impact on observations. We present an overview of the implementation of SIXTE from the input source, the imaging, and the detection process, highlighting the modular approach taken by the SIXTE software package. In order to demonstrate the capabilities of the simulation software, we present a selection of representative applications, including the all-sky survey of eROSITA and a study of pile-up effects comparing the currently operating XMM-Newton with the planned Athena-WFI instrument. A simulation of a galaxy cluster with the Athena- X-IFU shows the capability of SIXTE to predict the expected performance of an observation for a complex source with a spatially varying spectrum and our current knowledge of the future instrument.
[2]  oai:arXiv.org:1807.06092  [pdf] - 1717296
The Athena X-ray Integral Field Unit
Barret, Didier; Trong, Thien Lam; Herder, Jan-Willem den; Piro, Luigi; Cappi, Massimo; Huovelin, Juhani; Kelley, Richard; Mas-Hesse, J. Miguel; Mitsuda, Kazuhisa; Paltani, Stéphane; Rauw, Gregor; Rozanska, Agata; Wilms, Joern; Bandler, Simon; Barbera, Marco; Barcons, Xavier; Bozzo, Enrico; Ceballos, Maria Teresa; Charles, Ivan; Costantini, Elisa; Decourchelle, Anne; Hartog, Roland den; Duband, Lionel; Duval, Jean-Marc; Fiore, Fabrizio; Gatti, Flavio; Goldwurm, Andrea; Jackson, Brian; Jonker, Peter; Kilbourne, Caroline; Macculi, Claudio; Mendez, Mariano; Molendi, Silvano; Orleanski, Piotr; Pajot, François; Pointecouteau, Etienne; Porter, Frederick; Pratt, Gabriel W.; Prêle, Damien; Ravera, Laurent; Sato, Kosuke; Schaye, Joop; Shinozaki, Keisuke; Thibert, Tanguy; Valenziano, Luca; Valette, Veronique; Vink, Jacco; Webb, Natalie; Wise, Michael; Yamasaki, Noriko; Delcelier-Douchin, Françoise; Mesnager, Jean-Michel; Pontet, Bernard; Pradines, Alice; Branduardi-Raymont, Graziella; Bulbul, Esra; Dadina, Mauro; Ettori, Stefano; Finoguenov, Alexis; Fukazawa, Yasushi; Janiuk, Agnieszka; Kaastra, Jelle; Mazzotta, Pasquale; Miller, Jon; Miniutti, Giovanni; Nazé, Yaël; Nicastro, Fabrizio; Sciortino, Salvatore; Simionescu, Aurora; Torrejon, Jose Miguel; Frezouls, Benoît; Geoffray, Hervé; Peille, Philippe; Aicardi, Corinne; André, Jérôme; Clénet, Antoine; Daniel, Christophe; Etcheverry, Christophe; Gloaguen, Emilie; Hervet, Gilles; Jolly, Antoine; Ledot, Aurélien; Maussang, Irwin; Paillet, Alexis; Schmisser, Roseline; Vella, Bruno; Damery, Jean-Charles; Boyce, Kevin; DiPirro, Michael; Lotti, Simone; Schwander, Denis; Smith, Stephen; van Leeuwen, Bert-Joost; van Weers, Henk; Clerc, Nicolas; Cobo, Beatriz; Dauser, Thomas; de Plaa, Jelle; Kirsch, Christian; Cucchetti, Edoardo; Eckart, Megan; Ferrando, Philippe; Natalucci, Lorenzo
Comments: 15 pages, 5 figures, to appear in Proc. SPIE Astronomical Telescopes and Instrumentation, Austin 2018
Submitted: 2018-07-16
The X-ray Integral Field Unit (X-IFU) is the high resolution X-ray spectrometer of the ESA Athena X-ray observatory. Over a field of view of 5' equivalent diameter, it will deliver X-ray spectra from 0.2 to 12 keV with a spectral resolution of 2.5 eV up to 7 keV on ~5 arcsecond pixels. The X-IFU is based on a large format array of super-conducting molybdenum-gold Transition Edge Sensors cooled at about 90 mK, each coupled with an absorber made of gold and bismuth with a pitch of 249 microns. A cryogenic anti-coincidence detector located underneath the prime TES array enables the non X-ray background to be reduced. A bath temperature of about 50 mK is obtained by a series of mechanical coolers combining 15K Pulse Tubes, 4K and 2K Joule-Thomson coolers which pre-cool a sub Kelvin cooler made of a 3He sorption cooler coupled with an Adiabatic Demagnetization Refrigerator. Frequency domain multiplexing enables to read out 40 pixels in one single channel. A photon interacting with an absorber leads to a current pulse, amplified by the readout electronics and whose shape is reconstructed on board to recover its energy with high accuracy. The defocusing capability offered by the Athena movable mirror assembly enables the X-IFU to observe the brightest X-ray sources of the sky (up to Crab-like intensities) by spreading the telescope point spread function over hundreds of pixels. Thus the X-IFU delivers low pile-up, high throughput (>50%), and typically 10 eV spectral resolution at 1 Crab intensities, i.e. a factor of 10 or more better than Silicon based X-ray detectors. In this paper, the current X-IFU baseline is presented, together with an assessment of its anticipated performance in terms of spectral resolution, background, and count rate capability. The X-IFU baseline configuration will be subject to a preliminary requirement review that is scheduled at the end of 2018.