Normalized to: Kim, P.
[1]
oai:arXiv.org:1909.05413 [pdf] - 1982358
Graphene-based Josephson junction microwave bolometer
Lee, Gil-Ho;
Efetov, Dmitri K.;
Ranzani, Leonardo;
Walsh, Evan D.;
Ohki, Thomas A.;
Taniguchi, Takashi;
Watanabe, Kenji;
Kim, Philip;
Englund, Dirk;
Fong, Kin Chung
Submitted: 2019-09-11, last modified: 2019-10-18
Sensitive microwave detectors are critical instruments in radioastronomy,
dark matter axion searches, and superconducting quantum information science.
The conventional strategy towards higher-sensitivity bolometry is to
nanofabricate an ever-smaller device to augment the thermal response. However,
this direction is increasingly more difficult to obtain efficient photon
coupling and maintain the material properties in a device with a large
surface-to-volume ratio. Here we advance this concept to an ultimately thin
bolometric sensor based on monolayer graphene. To utilize its minute electronic
specific heat and thermal conductivity, we develop a
superconductor-graphene-superconductor (SGS) Josephson junction bolometer
embedded in a microwave resonator of resonant frequency 7.9 GHz with over 99\%
coupling efficiency. From the dependence of the Josephson switching current on
the operating temperature, charge density, input power, and frequency, we
demonstrate a noise equivalent power (NEP) of 7 $\times 10^{-19}$ W/Hz$^{1/2}$,
corresponding to an energy resolution of one single photon at 32 GHz and
reaching the fundamental limit imposed by intrinsic thermal fluctuation at 0.19
K.
[2]
oai:arXiv.org:1304.4279 [pdf] - 732067
Silicon Detector Dark Matter Results from the Final Exposure of CDMS II
CDMS Collaboration;
Agnese, R.;
Ahmed, Z.;
Anderson, A. J.;
Arrenberg, S.;
Balakishiyeva, D.;
Thakur, R. Basu;
Bauer, D. A.;
Billard, J.;
Borgland, A.;
Brandt, D.;
Brink, P. L.;
Bruch, T.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cerdeno, D. G.;
Chagani, H.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Dejongh, F.;
Silva, E. Do Couto E;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Filippini, J.;
Fox, J.;
Fritts, M.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, R. H.;
Hertel, S. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Kim, P.;
Kiveni, M.;
Koch, K.;
Kos, M.;
Leman, S. W.;
Loer, B.;
Asamar, E. Lopez;
Mahapatra, R.;
Mandic, V.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Moore, D. C.;
Nadeau, P.;
Nelson, R. H.;
Page, K.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Sundqvist, K. M.;
Villano, A. N.;
Welliver, B.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Yoo, J.;
Young, B. A.;
Zhang, J.
Submitted: 2013-04-15, last modified: 2013-10-11
We report results of a search for Weakly Interacting Massive Particles
(WIMPS) with the silicon detectors of the CDMS II experiment. This blind
analysis of 140.2 kg-days of data taken between July 2007 and September 2008
revealed three WIMP-candidate events with a surface-event background estimate
of 0.41^{+0.20}_{-0.08}(stat.)^{+0.28}_{-0.24}(syst.). Other known backgrounds
from neutrons and 206Pb are limited to < 0.13 and <0.08 events at the 90%
confidence level, respectively. The exposure of this analysis is equivalent to
23.4 kg-days for a recoil energy range of 7-100 keV for a WIMP of mass 10
GeV/c2. The probability that the known backgrounds would produce three or more
events in the signal region is 5.4%. A profile likelihood ratio test of the
three events that includes the measured recoil energies gives a 0.19%
probability for the known-background-only hypothesis when tested against the
alternative WIMP+background hypothesis. The highest likelihood occurs for a
WIMP mass of 8.6 GeV/c2 and WIMP-nucleon cross section of 1.9e-41 cm2.
[3]
oai:arXiv.org:1304.3706 [pdf] - 719385
Silicon detector results from the first five-tower run of CDMS II
CDMS Collaboration;
Agnese, R.;
Ahmed, Z.;
Anderson, A. J.;
Arrenberg, S.;
Balakishiyeva, D.;
Thakur, R. Basu;
Bauer, D. A.;
Borgland, A.;
Brandt, D.;
Brink, P. L.;
Bruch, T.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cerdeno, D. G.;
Chagani, H.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Dejongh, F.;
Di Stefano, P. C. F.;
Silva, E. do Couto e;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Filippini, J.;
Fox, J.;
Fritts, M.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, R. H.;
Hertel, S. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Kim, P.;
Kiveni, M.;
Koch, K.;
Kos, M.;
Leman, S. W.;
Lopez-Asamar, E.;
Mahapatra, R.;
Mandic, V.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Moore, D. C.;
Nadeau, P.;
Nelson, R. H.;
Page, K.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Sundqvist, K. M.;
Villano, A. N.;
Welliver, B.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Yoo, J.;
Young, B. A.;
Zhan, J.
Submitted: 2013-04-12, last modified: 2013-09-14
We report results of a search for Weakly Interacting Massive Particles
(WIMPs) with the Si detectors of the CDMS II experiment. This report describes
a blind analysis of the first data taken with CDMS II's full complement of
detectors in 2006-2007; results from this exposure using the Ge detectors have
already been presented. We observed no candidate WIMP-scattering events in an
exposure of 55.9 kg-days before analysis cuts, with an expected background of
~1.1 events. The exposure of this analysis is equivalent to 10.3 kg-days over a
recoil energy range of 7-100 keV for an ideal Si detector and a WIMP mass of 10
GeV/c2. These data set an upper limit of 1.7x10-41 cm2 on the WIMP-nucleon
spin-independent cross section of a 10 GeV/c2 WIMP. These data exclude
parameter space for spin-independent WIMP-nucleon elastic scattering that is
relevant to recent searches for low-mass WIMPs.
[4]
oai:arXiv.org:1109.1198 [pdf] - 1083866
Monte Carlo Comparisons to a Cryogenic Dark Matter Search Detector with
low Transition-Edge-Sensor Transition Temperature
Leman, S. W.;
McCarthy, K. A.;
Brink, P. L.;
Cabrera, B.;
Cherry, M.;
Silva, E. Do Couto E;
Figueroa-Feliciano, E.;
Kim, P.;
Mirabolfathi, N.;
Pyle, M.;
Resch, R.;
Sadoulet, B.;
Serfass, B.;
Sundqvist, K. M.;
Tomada, A.;
Young, B. A.
Submitted: 2011-09-06
We present results on phonon quasidiffusion and Transition Edge Sensor (TES)
studies in a large, 3 inch diameter, 1 inch thick [100] high purity germanium
crystal, cooled to 50 mK in the vacuum of a dilution refrigerator, and exposed
with 59.5 keV gamma-rays from an Am-241 calibration source. We compare
calibration data with results from a Monte Carlo which includes phonon
quasidiffusion and the generation of phonons created by charge carriers as they
are drifted across the detector by ionization readout channels. The phonon
energy is then parsed into TES based phonon readout channels and input into a
TES simulator.
[5]
oai:arXiv.org:1109.0551 [pdf] - 1934625
Validation of Phonon Physics in the CDMS Detector Monte Carlo
McCarthy, K. A.;
Leman, S. W.;
Anderson, A. J.;
Brandt, D.;
Brink, P. L.;
Cabrera, B.;
Cherry, M.;
Silva, E. Do Couto E;
Cushman, P.;
Doughty, T.;
Figueroa-Feliciano, E.;
Kim, P.;
Mirabolfathi, N.;
Novak, L.;
Partridge, R.;
Pyle, M.;
Reisetter, A.;
Resch, R.;
Sadoulet, B.;
Serfass, B.;
Sundqvist, K. M.;
Tomada, A.
Submitted: 2011-09-02
The SuperCDMS collaboration is a dark matter search effort aimed at detecting
the scattering of WIMP dark matter from nuclei in cryogenic germanium targets.
The CDMS Detector Monte Carlo (CDMS-DMC) is a simulation tool aimed at
achieving a deeper understanding of the performance of the SuperCDMS detectors
and aiding the dark matter search analysis. We present results from validation
of the phonon physics described in the CDMS-DMC and outline work towards
utilizing it in future WIMP search analyses.
[6]
oai:arXiv.org:1108.6245 [pdf] - 1934624
Comparison of CDMS [100] and [111] oriented germanium detectors
Leman, S. W.;
Hertel, S. A.;
Kim, P.;
Cabrera, B.;
Silva, E. Do Couto E;
Figueroa-Feliciano, E.;
McCarthy, K. A.;
Resch, R.;
Sadoulet, B.;
Sundqvist, K. M.
Submitted: 2011-08-31
The Cryogenic Dark Matter Search (CDMS) utilizes large mass, 3" diameter
$\times$ 1" thick target masses as particle detectors. The target is
instrumented with both phonon and ionization sensors and comparison of energy
in each channel provides event-by-event classification of electron and nuclear
recoils. Fiducial volume is determined by the ability to obtain good phonon and
ionization signal at a particular location. Due to electronic band structure in
germanium, electron mass is described by an anisotropic tensor with heavy mass
aligned along the symmetry axis defined by the [111] Miller index (L valley),
resulting in large lateral component to the transport. The spatial distribution
of electrons varies significantly for detectors which have their longitudinal
axis orientations described by either the [100] or [111] Miller indices.
Electric fields with large fringing component at high detector radius also
affect the spatial distribution of electrons and holes. Both effects are
studied in a 3 dimensional Monte Carlo and the impact on fiducial volume is
discussed.
[7]
oai:arXiv.org:0910.4198 [pdf] - 951084
A Multi-Chamber System for Analyzing the Outgassing, Deposition, and
Associated Optical Degradation Properties of Materials in a Vacuum
Submitted: 2009-10-21, last modified: 2010-08-16
We report on the Camera Materials Test Chamber, a multi-vessel apparatus
which analyzes the outgassing consequences of candidate materials for use in
the vacuum cryostat of a new telescope camera. The system measures the
outgassing products and rates of samples of materials at different
temperatures, and collects films of outgassing products to measure the effects
on light transmission in six optical bands. The design of the apparatus
minimizes potential measurement errors introduced by background contamination.