sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Kim, P.

Normalized to: Kim, P.

7 article(s) in total. 110 co-authors, from 1 to 5 common article(s). Median position in authors list is 8,0.

[1]  oai:arXiv.org:1909.05413  [pdf] - 1982358
Graphene-based Josephson junction microwave bolometer
Comments: 8 pages, 4 figures
Submitted: 2019-09-11, last modified: 2019-10-18
Sensitive microwave detectors are critical instruments in radioastronomy, dark matter axion searches, and superconducting quantum information science. The conventional strategy towards higher-sensitivity bolometry is to nanofabricate an ever-smaller device to augment the thermal response. However, this direction is increasingly more difficult to obtain efficient photon coupling and maintain the material properties in a device with a large surface-to-volume ratio. Here we advance this concept to an ultimately thin bolometric sensor based on monolayer graphene. To utilize its minute electronic specific heat and thermal conductivity, we develop a superconductor-graphene-superconductor (SGS) Josephson junction bolometer embedded in a microwave resonator of resonant frequency 7.9 GHz with over 99\% coupling efficiency. From the dependence of the Josephson switching current on the operating temperature, charge density, input power, and frequency, we demonstrate a noise equivalent power (NEP) of 7 $\times 10^{-19}$ W/Hz$^{1/2}$, corresponding to an energy resolution of one single photon at 32 GHz and reaching the fundamental limit imposed by intrinsic thermal fluctuation at 0.19 K.
[2]  oai:arXiv.org:1304.4279  [pdf] - 732067
Silicon Detector Dark Matter Results from the Final Exposure of CDMS II
Comments: 5 pages, 4 figures, as accepted by PRL
Submitted: 2013-04-15, last modified: 2013-10-11
We report results of a search for Weakly Interacting Massive Particles (WIMPS) with the silicon detectors of the CDMS II experiment. This blind analysis of 140.2 kg-days of data taken between July 2007 and September 2008 revealed three WIMP-candidate events with a surface-event background estimate of 0.41^{+0.20}_{-0.08}(stat.)^{+0.28}_{-0.24}(syst.). Other known backgrounds from neutrons and 206Pb are limited to < 0.13 and <0.08 events at the 90% confidence level, respectively. The exposure of this analysis is equivalent to 23.4 kg-days for a recoil energy range of 7-100 keV for a WIMP of mass 10 GeV/c2. The probability that the known backgrounds would produce three or more events in the signal region is 5.4%. A profile likelihood ratio test of the three events that includes the measured recoil energies gives a 0.19% probability for the known-background-only hypothesis when tested against the alternative WIMP+background hypothesis. The highest likelihood occurs for a WIMP mass of 8.6 GeV/c2 and WIMP-nucleon cross section of 1.9e-41 cm2.
[3]  oai:arXiv.org:1304.3706  [pdf] - 719385
Silicon detector results from the first five-tower run of CDMS II
Comments: 5 pages, 4 figures; updated to match published version
Submitted: 2013-04-12, last modified: 2013-09-14
We report results of a search for Weakly Interacting Massive Particles (WIMPs) with the Si detectors of the CDMS II experiment. This report describes a blind analysis of the first data taken with CDMS II's full complement of detectors in 2006-2007; results from this exposure using the Ge detectors have already been presented. We observed no candidate WIMP-scattering events in an exposure of 55.9 kg-days before analysis cuts, with an expected background of ~1.1 events. The exposure of this analysis is equivalent to 10.3 kg-days over a recoil energy range of 7-100 keV for an ideal Si detector and a WIMP mass of 10 GeV/c2. These data set an upper limit of 1.7x10-41 cm2 on the WIMP-nucleon spin-independent cross section of a 10 GeV/c2 WIMP. These data exclude parameter space for spin-independent WIMP-nucleon elastic scattering that is relevant to recent searches for low-mass WIMPs.
[4]  oai:arXiv.org:1109.1198  [pdf] - 1083866
Monte Carlo Comparisons to a Cryogenic Dark Matter Search Detector with low Transition-Edge-Sensor Transition Temperature
Comments:
Submitted: 2011-09-06
We present results on phonon quasidiffusion and Transition Edge Sensor (TES) studies in a large, 3 inch diameter, 1 inch thick [100] high purity germanium crystal, cooled to 50 mK in the vacuum of a dilution refrigerator, and exposed with 59.5 keV gamma-rays from an Am-241 calibration source. We compare calibration data with results from a Monte Carlo which includes phonon quasidiffusion and the generation of phonons created by charge carriers as they are drifted across the detector by ionization readout channels. The phonon energy is then parsed into TES based phonon readout channels and input into a TES simulator.
[5]  oai:arXiv.org:1109.0551  [pdf] - 1934625
Validation of Phonon Physics in the CDMS Detector Monte Carlo
Comments: 6 Pages, 5 Figures, Proceedings of Low Temperature Detectors 14 Conference
Submitted: 2011-09-02
The SuperCDMS collaboration is a dark matter search effort aimed at detecting the scattering of WIMP dark matter from nuclei in cryogenic germanium targets. The CDMS Detector Monte Carlo (CDMS-DMC) is a simulation tool aimed at achieving a deeper understanding of the performance of the SuperCDMS detectors and aiding the dark matter search analysis. We present results from validation of the phonon physics described in the CDMS-DMC and outline work towards utilizing it in future WIMP search analyses.
[6]  oai:arXiv.org:1108.6245  [pdf] - 1934624
Comparison of CDMS [100] and [111] oriented germanium detectors
Comments: Low Temperature Detector 14 conference proceedings to be published in the Journal of Low Temperature Physics
Submitted: 2011-08-31
The Cryogenic Dark Matter Search (CDMS) utilizes large mass, 3" diameter $\times$ 1" thick target masses as particle detectors. The target is instrumented with both phonon and ionization sensors and comparison of energy in each channel provides event-by-event classification of electron and nuclear recoils. Fiducial volume is determined by the ability to obtain good phonon and ionization signal at a particular location. Due to electronic band structure in germanium, electron mass is described by an anisotropic tensor with heavy mass aligned along the symmetry axis defined by the [111] Miller index (L valley), resulting in large lateral component to the transport. The spatial distribution of electrons varies significantly for detectors which have their longitudinal axis orientations described by either the [100] or [111] Miller indices. Electric fields with large fringing component at high detector radius also affect the spatial distribution of electrons and holes. Both effects are studied in a 3 dimensional Monte Carlo and the impact on fiducial volume is discussed.
[7]  oai:arXiv.org:0910.4198  [pdf] - 951084
A Multi-Chamber System for Analyzing the Outgassing, Deposition, and Associated Optical Degradation Properties of Materials in a Vacuum
Comments: 9 pages, 10 figures, published in RSI (minor edits made to match journal accepted version)
Submitted: 2009-10-21, last modified: 2010-08-16
We report on the Camera Materials Test Chamber, a multi-vessel apparatus which analyzes the outgassing consequences of candidate materials for use in the vacuum cryostat of a new telescope camera. The system measures the outgassing products and rates of samples of materials at different temperatures, and collects films of outgassing products to measure the effects on light transmission in six optical bands. The design of the apparatus minimizes potential measurement errors introduced by background contamination.