sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Kilpia, V. H.

Normalized to: Kilpia, V.

5 article(s) in total. 204 co-authors, from 1 to 5 common article(s). Median position in authors list is 49,0.

[1]  oai:arXiv.org:1101.2038  [pdf] - 955981
Planck early results. III. First assessment of the Low Frequency Instrument in-flight performance
Mennella, A.; Bersanelli, M.; Butler, R. C.; Curto, A.; Cuttaia, F.; Davis, R. J.; Dick, J.; Frailis, M.; Galeotta, S.; Gregorio, A.; Kurki-Suonio, H.; Lawrence, C. R.; Leach, S.; Leahy, J. P.; Lowe, S.; Maino, D.; Mandolesi, N.; Maris, M.; Martínez-González, E.; Meinhold, P. R.; Morgante, G.; Pearson, D.; Perrotta, F.; Polenta, G.; Poutanen, T.; Sandri, M.; Seiffert, M. D.; Suur-Uski, A. -S.; Tavagnacco, D.; Terenzi, L.; Tomasi, M.; Valiviita, J.; Villa, F.; Watson, R.; Wilkinson, A.; Zacchei, A.; Zonca, A.; Aja, B.; Artal, E.; Baccigalupi, C.; Banday, A. J.; Barreiro, R. B.; Bartlett, J. G.; Bartolo, N.; Battaglia, P.; Bennett, K.; Bonaldi, A.; Bonavera, L.; Borrill, J.; Bouchet, F. R.; Burigana, C.; Cabella, P.; Cappellini, B.; Chen, X.; Colombo, L.; Cruz, M.; Danese, L.; D'Arcangelo, O.; Davies, R. D.; de Gasperis, G.; de Rosa, A.; de Zotti, G.; Dickinson, C.; Diego, J. M.; Donzelli, S.; Efstathiou, G.; Enßlin, T. A.; Eriksen, H. K.; Falvella, M. C.; Finelli, F.; Foley, S.; Franceschet, C.; Franceschi, E.; Gaier, T. C.; Génova-Santos, R. T.; George, D.; Gómez, F.; González-Nuevo, J.; Górski, K. M.; Gruppuso, A.; Hansen, F. K.; Herranz, D.; Herreros, J. M.; Hoyland, R. J.; Hughes, N.; Jewell, J.; Jukkala, P.; Juvela, M.; Kangaslahti, P.; Keihänen, E.; Keskitalo, R.; Kilpia, V. -H.; Kisner, T. S.; Knoche, J.; Knox, L.; Laaninen, M.; Lähteenmäki, A.; Lamarre, J. -M.; Leonardi, R.; León-Tavares, J.; Leutenegger, P.; Lilje, P. B.; López-Caniego, M.; Lubin, P. M.; Malaspina, M.; Marinucci, D.; Massardi, M.; Matarrese, S.; Matthai, F.; Melchiorri, A.; Mendes, L.; Miccolis, M.; Migliaccio, M.; Mitra, S.; Moss, A.; Natoli, P.; Nesti, R.; Nørgaard-Nielsen, H. U.; Pagano, L.; Paladini, R.; Paoletti, D.; Partridge, B.; Pasian, F.; Pettorino, V.; Pietrobon, D.; Pospieszalski, M.; Prézeau, G.; Prina, M.; Procopio, P.; Puget, J. -L.; Quercellini, C.; Rachen, J. P.; Rebolo, R.; Reinecke, M.; Ricciardi, S.; Robbers, G.; Rocha, G.; Roddis, N.; Rubiño-Martín, J. A.; Savelainen, M.; Scott, D.; Silvestri, R.; Simonetto, A.; Sjoman, P.; Smoot, G. F.; Sozzi, C.; Stringhetti, L.; Tauber, J. A.; Tofani, G.; Toffolatti, L.; Tuovinen, J.; Türler, M.; Umana, G.; Valenziano, L.; Varis, J.; Vielva, P.; Vittorio, N.; Wade, L. A.; Watson, C.; White, S. D. M.; Winder, F.
Comments: Published version
Submitted: 2011-01-11, last modified: 2011-12-19
The scientific performance of the Planck Low Frequency Instrument (LFI) after one year of in-orbit operation is presented. We describe the main optical parameters and discuss photometric calibration, white noise sensitivity, and noise properties. A preliminary evaluation of the impact of the main systematic effects is presented. For each of the performance parameters, we outline the methods used to obtain them from the flight data and provide a comparison with pre-launch ground assessments, which are essentially confirmed in flight.
[2]  oai:arXiv.org:1005.2541  [pdf] - 1032478
Planck pre-launch status: calibration of the Low Frequency Instrument flight model radiometers
Comments: 15 pages, 18 figures. Accepted for publication in Astronomy and Astrophysics
Submitted: 2010-05-14
The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each composed of a pair of pseudo-correlation receivers. We describe the on-ground calibration campaign performed to qualify the flight model RCAs and to measure their pre-launch performances. Each RCA was calibrated in a dedicated flight-like cryogenic environment with the radiometer front-end cooled to 20K and the back-end at 300K, and with an external input load cooled to 4K. A matched load simulating a blackbody at different temperatures was placed in front of the sky horn to derive basic radiometer properties such as noise temperature, gain, and noise performance, e.g. 1/f noise. The spectral response of each detector was measured as was their susceptibility to thermal variation. All eleven LFI RCAs were calibrated. Instrumental parameters measured in these tests, such as noise temperature, bandwidth, radiometer isolation, and linearity, provide essential inputs to the Planck-LFI data analysis.
[3]  oai:arXiv.org:1001.4589  [pdf] - 33143
Planck-LFI radiometers' spectral response
Comments: 16 pages, 9 figures, this paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst
Submitted: 2010-01-26
The Low Frequency Instrument (LFI) is an array of pseudo-correlation radiometers on board the Planck satellite, the ESA mission dedicated to precision measurements of the Cosmic Microwave Background. The LFI covers three bands centred at 30, 44 and 70 GHz, with a goal bandwidth of 20% of the central frequency. The characterization of the broadband frequency response of each radiometer is necessary to understand and correct for systematic effects, particularly those related to foreground residuals and polarization measurements. In this paper we present the measured band shape of all the LFI channels and discuss the methods adopted for their estimation. The spectral characterization of each radiometer was obtained by combining the measured spectral response of individual units through a dedicated RF model of the LFI receiver scheme. As a consistency check, we also attempted end-to-end spectral measurements of the integrated radiometer chain in a cryogenic chamber. However, due to systematic effects in the measurement setup, only qualitative results were obtained from these tests. The measured LFI bandpasses exhibit a moderate level of ripple, compatible with the instrument scientific requirements.
[4]  oai:arXiv.org:1001.4661  [pdf] - 33165
Design, development, and verification of the Planck Low Frequency Instrument 70 GHz Front-End and Back-End Modules
Comments: 16 pages, 15 figures. This paper is part of of the prelaunch status Planck LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst
Submitted: 2010-01-26
70 GHz radiometer front-end and back-end modules for the Low Frequency Instrument of the European Space Agencys Planck Mission were built and tested. The operating principles and the design details of the mechanical structures are described along with the key InP MMIC low noise amplifiers and phase switches of the units. The units were tested in specially designed cryogenic vacuum chambers capable of producing the operating conditions required for Planck radiometers, specifically, a physical temperature of 20 K for the front-end modules, 300 K for the back-end modules and 4 K for the reference signal sources. Test results of the low noise amplifiers and phase switches, the front and back-end modules, and the combined results of both modules are discussed. At 70 GHz frequency, the system noise temperature of the front and back end is 28 K; the effective bandwidth 16 GHz, and the 1/f spectrum knee frequency is 38 mHz. The test results indicate state-of-the-art performance at 70 GHz frequency and fulfil the Planck performance requirements.
[5]  oai:arXiv.org:1001.3321  [pdf] - 1024699
Planck pre-launch status: Design and description of the Low Frequency Instrument
Bersanelli, M.; Mandolesi, N.; Butler, R. C.; Mennella, A.; Villa, F.; Aja, B.; Artal, E.; Artina, E.; Baccigalupi, C.; Balasini, M.; Baldan, G.; Banday, A.; Bastia, P.; Battaglia, P.; Bernardino, T.; Blackhurst, E.; Boschini, L.; Burigana, C.; Cafagna, G.; Cappellini, B.; Cavaliere, F.; Colombo, F.; Crone, G.; Cuttaia, F.; D'Arcangelo, O.; Danese, L.; Davies, R. D.; Davis, R. J.; De Angelis, L.; De Gasperis, G. C.; De La Fuente, L.; De Rosa, A.; De Zotti, G.; Falvella, M. C.; Ferrari, F.; Ferretti, R.; Figini, L.; Fogliani, S.; Franceschet, C.; Franceschi, E.; Gaier, T.; Garavaglia, S.; Gomez, F.; Gorski, K.; Gregorio, A.; Guzzi, P.; Herreros, J. M.; Hildebrandt, S. R.; Hoyland, R.; Hughes, N.; Janssen, M.; Jukkala, P.; Kettle, D.; Kilpia, V. H.; Laaninen, M.; Lapolla, P. M.; Lawrence, C. R.; Leahy, J. P.; Leonardi, R.; Leutenegger, P.; Levin, S.; Lilje, P. B.; Lowe, S. R.; Lubin, D. Lawson P. M.; Maino, D.; Malaspina, M.; Maris, M.; Marti-Canales, J.; Martinez-Gonzalez, E.; Mediavilla, A.; Meinhold, P.; Miccolis, M.; Morgante, G.; Natoli, P.; Nesti, R.; Pagan, L.; Paine, C.; Partridge, B.; Pascual, J. P.; Pasian, F.; Pearson, D.; Pecora, M.; Perrotta, F.; Platania, P.; Pospieszalski, M.; Poutanen, T.; Prina, M.; Rebolo, R.; Roddis, N.; Rubino-Martin, J. A.; Salmon, n M. J.; Sandri, M.; Seiffert, M.; Silvestri, R.; Simonetto, A.; Sjoman, P.; Smoot, G. F.; Sozzi, C.; Stringhetti, L.; Taddei, E.; Tauber, J.; Terenzi, L.; Tomasi, M.; Tuovinen, J.; Valenziano, L.; Varis, J.; Vittorio, N.; Wade, L. A.; Wilkinson, A.; Winder, F.; Zacchei, A.; Zonca, A.
Comments: 23 pages, 31 figures, accepted by Astronomy and Astrophysics, Planck LFI technical papers published by JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/1748-0221
Submitted: 2010-01-19
In this paper we present the Low Frequency Instrument (LFI), designed and developed as part of the Planck space mission, the ESA program dedicated to precision imaging of the cosmic microwave background (CMB). Planck-LFI will observe the full sky in intensity and polarisation in three frequency bands centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be covered by the HFI instrument. The LFI is an array of microwave radiometers based on state-of-the-art Indium Phosphide cryogenic HEMT amplifiers implemented in a differential system using blackbody loads as reference signals. The front-end is cooled to 20K for optimal sensitivity and the reference loads are cooled to 4K to minimise low frequency noise. We provide an overview of the LFI, discuss the leading scientific requirements and describe the design solutions adopted for the various hardware subsystems. The main drivers of the radiometric, optical and thermal design are discussed, including the stringent requirements on sensitivity, stability, and rejection of systematic effects. Further details on the key instrument units and the results of ground calibration are provided in a set of companion papers.