sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Kerr, A. R.

Normalized to: Kerr, A.

5 article(s) in total. 24 co-authors, from 1 to 2 common article(s). Median position in authors list is 2,0.

[1]  oai:arXiv.org:1907.13198  [pdf] - 1926525
Room Temperature, Quantum-Limited THz Heterodyne Detection? Not Yet
Comments: 4 pages, 15 references
Submitted: 2019-07-30
In their article, Wang et al. [1] report a new scheme for THz heterodyne detection using a laser-driven LTG-GaAs photomixer [2, 3] and make the impressive claim of achieving near quantum-limited sensitivity at room temperature. Unfortunately, their experimental methodology is incorrect, and furthermore the paper provides no information on the mixer conversion loss, an important quantity that could readily have been measured and reported as a consistency check. The paper thus offers no reliable experimental evidence that substantiates the claimed sensitivities. To the contrary, the very high value reported for their photomixer impedance strongly suggests that the conversion loss is quite poor and that the actual sensitivity is far worse than claimed.
[2]  oai:arXiv.org:1509.05273  [pdf] - 1278884
Microwave Loss Reduction in Cryogenically Cooled Conductors
Comments: 9 pages
Submitted: 2015-09-17
Measurements of microwave attenuation at room temperature and 4.2 K have been performed on some conductors commonly used in receiver input circuits. The reduction in loss on cooling is substantial, particularly for copper and plated gold, both of which showed a factor of 3 loss reduction. Copper passivated with benzotriazole shows the same loss as without passivation. The residual resistivity ratio between room temperature and 4.2 K, deduced from the measurements using the classical skin effect formula, was smaller than the measured DC value to a degree consistent with conduction in the extreme anomalous skin effect regime at cryogenic temperatures. The measurements were made in the 5-10 GHz range. The materials tested were: aluminum alloys 1100-T6 and 6061-O, C101 copper, benzotriazole treated C101 copper, and brass plated with electroformed copper, Pur-A-Gold 125-Au soft gold, and BDT200 bright gold.
[3]  oai:arXiv.org:1306.6085  [pdf] - 1172294
Development of the ALMA-North America Sideband-Separating SIS Mixers
Comments: Submitted to IEEE Trans. Microwave Theory Tech., June 2013. 10 pages, 21 figures
Submitted: 2013-06-25
As the Atacama Large Millimeter/submillimeter Array (ALMA) nears completion, 73 dual-polarization receivers have been delivered for each of Bands 3 (84-116 GHz) and 6 (211-275 GHz). The receivers use sideband-separating superconducting Nb/Al-AlOx/Nb tunnel-junction (SIS) mixers, developed for ALMA to suppress atmospheric noise in the image band. The mixers were designed taking into account dynamic range, input return loss, and signal-to-image conversion (which can be significant in SIS mixers). Typical SSB receiver noise temperatures in Bands 3 and 6 are 30 K and 60 K, resp., and the image rejection is typically 15 dB.
[4]  oai:arXiv.org:0908.3826  [pdf] - 27641
Large Instrument Development for Radio Astronomy
Comments:
Submitted: 2009-08-26
This white paper offers cautionary observations about the planning and development of new, large radio astronomy instruments. Complexity is a strong cost driver so every effort should be made to assign differing science requirements to different instruments and probably different sites. The appeal of shared resources is generally not realized in practice and can often be counterproductive. Instrument optimization is much more difficult with longer lists of requirements, and the development process is longer and less efficient. More complex instruments are necessarily further behind the technology state of the art because of longer development times. Including technology R&D in the construction phase of projects is a growing trend that leads to higher risks, cost overruns, schedule delays, and project de-scoping. There are no technology breakthroughs just over the horizon that will suddenly bring down the cost of collecting area. Advances come largely through careful attention to detail in the adoption of new technology provided by industry and the commercial market. Radio astronomy instrumentation has a very bright future, but a vigorous long-term R&D program not tied directly to specific projects needs to be restored, fostered, and preserved.
[5]  oai:arXiv.org:gr-qc/0301057  [pdf] - 111153
Standard Clocks, Orbital Precession and the Cosmological Constant
Comments: LaTeX file, no figures, 16 pages, amended version
Submitted: 2003-01-16, last modified: 2003-04-24
We discuss the influence of the cosmological constant on the gravitomagnetic clock effect and the gravitational time delay of electromagnetic rays. Moreover, we consider the relative motion of a binary system to linear order in the cosmological constant $\Lambda$. The general expression for the effect of $\Lambda$ on pericenter precession is given for arbitrary orbital eccentricity.