Normalized to: Kepa, A.
[1]
oai:arXiv.org:1912.07984 [pdf] - 2061630
A Multiwavelength Analysis of the Long-duration Flare Observed on 15
April 2002
Submitted: 2019-12-17
We present a multiwavelength analysis of the long duration flare observed on
15 April 2002 (soft X-ray peak time at 03:55 UT, SOL2002-04-15T03:55). This
flare occurred on the disk (S15W01) in NOAA 9906 and was observed by a number
of space instruments including the Extreme-Ultraviolet Imaging Telescope on the
Solar and Heliospheric Observatory (SOHO/EIT), the RESIK spectrometer onboard
the Coronas-F spacecraft, and the Ramaty High Energy Solar Spectroscopic Imager
(RHESSI). We have performed a complex analysis of these measurements and
studied the morphology and physical parameters characterizing the conditions in
flaring plasmas. The 195 A SOHO/EIT images have been used to study evolution of
flaring loops. Analysis of RHESSI data provided the opportunity for a detailed
analysis of hard X-ray emission with 1 keV energy resolution. We have used
Geostationary Operational Environmental Satellite (GOES) observations for
isothermal interpretation of the X-ray measurements. Temperature diagnostics of
the flaring plasma have been carried out by means of a differential emission
measure (DEM) analysis based on RESIK X-ray spectra.
[2]
oai:arXiv.org:1503.00979 [pdf] - 1055813
RESIK Solar X-ray flare element abundances on a non-isothermal
assumption
Submitted: 2015-03-03
Solar X-ray spectra from the RESIK crystal spectrometer on the {\em
CORONAS-F} spacecraft (spectral range $3.3-6.1$~\AA) are analyzed for
thirty-three flares using a method to derive abundances of Si, S, Ar, and K,
emission lines of which feature prominently in the spectra. For each spectrum,
the method first optimizes element abundances then derives the differential
emission measure as a function of temperature based on a procedure given by
Sylwester et al. and Withbroe. This contrasts with our previous analyses of
RESIK spectra in which an isothermal assumption was used. The revised
abundances (on a logarithmic scale with $A({\rm H}) = 12$) averaged for all the
flares in the analysis are $A({\rm Si}) = 7.53 \pm 0.08$ (previously $7.89 \pm
0.13$), $A({\rm S}) = 6.91 \pm 0.07$ ($7.16 \pm 0.17$), $A({\rm Ar}) = 6.47 \pm
0.08$ ($6.45 \pm 0.07$), and $A({\rm K}) = 5.73 \pm 0.19$ ($5.86 \pm 0.20$),
with little evidence for time variations of abundances within the evolution of
each flare. Our previous estimates of the Ar and K flare abundances are thus
confirmed by this analysis but those for Si and S are reduced. This suggests
the flare abundances of Si and Ar are very close to the photospheric abundance
or solar proxies, while S is significantly less than photospheric and the K
abundance is much higher than photospheric. These estimates differ to some
extent from those in which a single enhancement factor applies to elements with
first ionization potential less than 10~eV.
[3]
oai:arXiv.org:1404.5775 [pdf] - 1209119
Solar Flare Composition and Thermodynamics from RESIK X-ray Spectra
Submitted: 2014-04-23, last modified: 2014-04-24
Previous estimates of the solar flare abundances of Si, S, Cl, Ar, and K from
the RESIK X-ray crystal spectrometer on board the CORONAS-F spacecraft were
made on the assumption of isothermal X-ray emission. We investigate the effect
on these estimates by relaxing this assumption and instead determining the
differential emission measure (DEM) or thermal structure of the emitting plasma
by re-analyzing RESIK data for a GOES class M1.0 flare on 2002 November~14
(SOL2002-11-14T22:26) for which there was good data coverage. The analysis
method uses a maximum-likelihood (Withbroe--Sylwester) routine for evaluating
the DEM. In a first step, called here AbuOpt, an optimized set of abundances of
Si, S, Ar, and K is found that is consistent with the observed spectra. With
these abundances, the differential emission measure evolution during the flare
is found. The abundance optimization leads to revised abundances of silicon and
sulfur in the flare plasma: $A({\rm S}) = 6.94 \pm 0.06$ and $A({\rm Si}) =
7.56 \pm 0.08$ (on a logarithmic scale with $A({\rm H}) = 12$). Previously
determined abundances of Ar, K, and Cl from an isothermal assumption are still
the preferred values. During the flare's maximum phase, the X-ray-emitting
plasma has a basically two-temperature structure, with the cooler plasma with
approximately constant temperature (3--6~MK) and a hotter plasma with
temperature $16-21$~MK. Using imaging data from the RHESSI hard X-ray
spacecraft, the emission volume of the hot plasma is deduced from which lower
limits of the electron density $N_e$ and the thermal content of the plasma are
given.
[4]
oai:arXiv.org:1212.2914 [pdf] - 1158467
Silicon abundance from RESIK solar flare observations
Submitted: 2012-12-12
The RESIK instrument on the CORONAS-F spacecraft obtained solar flare and
active region X-ray spectra in four channels covering the wavelength range 3.8
-- 6.1 \AA in its operational period between 2001 and 2003. Several highly
ionized silicon lines were observed within the range of the long-wavelength
channel (5.00 -- 6.05 \AA). The fluxes of the \sixiv Ly-$\beta$ line (5.217
\AA) and the \sixiii $1s^2 - 1s3p$ line (5.688 \AA) during 21 flares with
optimized pulse-height analyzer settings on RESIK have been analyzed to obtain
the silicon abundance relative to hydrogen in flare plasmas. As in previous
work, the emitting plasma for each spectrum is assumed to be characterized by a
single temperature and emission measure given by the ratio of emission in the
two channels of GOES. The silicon abundance is determined to be $A({\rm Si}) =
7.93 \pm .21$ (\sixiv) and $7.89 \pm .13$ (\sixiii) on a logarithmic scale with
H = 12. These values, which vary by only very small amounts from flare to flare
and times within flares, are $2.6 \pm 1.3$ and $2.4 \pm 0.7$ times the
photospheric abundance, and are about a factor of three higher than RESIK
measurements during a period of very low activity. There is a suggestion that
the Si/S abundance ratio increases from active regions to flares.
[5]
oai:arXiv.org:0806.0935 [pdf] - 1000759
Diagnostic of the temperature and differential emission measure (DEM)
based on Hinode/XRT data
Submitted: 2008-06-05
We discuss here various methodologies and an optimal strategy of the
temperature and emission measure diagnostics based on Hinode X-Ray Telescope
data. As an example of our results we present determination of the temperature
distribution of the X-rays emitting plasma using filters ratio method and three
various methods of the calculation of the differential emission measure (DEM).
We have found that all these methods give results similar to the two filters
ratio method. Additionally, all methods of the DEM calculation gave similar
solutions. We can state that the majority of the pairs of the Hinode filters
allows one to derive the temperature and emission measure in the isothermal
plasma approximation using standard diagnostic based on two filters ratio
method. In cases of strong flares one can also expect well conformity of the
results obtained using a Withbroe - Sylwester, genetic algorithm and
least-square methods of the DEM evaluation.