Normalized to: Kawate, K.
[1]
oai:arXiv.org:1111.6746 [pdf] - 1091982
FIBRE-pac: FMOS image-based reduction package
Iwamuro, F.;
Moritani, Y.;
Yabe, K.;
Sumiyoshi, M.;
Kawate, K.;
Tamura, N.;
Akiyama, M.;
Kimura, M.;
Takato, N.;
Tait, P.;
Ohta, K.;
Totani, T.;
Suzuki, Y.;
Tonegawa, M.
Submitted: 2011-11-29
The FIBRE-pac (FMOS image-based reduction package) is an IRAF-based reduction
tool for the fiber multiple-object spectrograph (FMOS) of the Subaru telescope.
To reduce FMOS images, a number of special techniques are necessary because
each image contains about 200 separate spectra with airglow emission lines
variable in spatial and time domains, and with complicated throughput patterns
for the airglow masks. In spite of these features, almost all of the reduction
processes except for a few steps are carried out automatically by scripts in
text format making it easy to check the commands step by step. Wavelength- and
flux-calibrated images together with their noise maps are obtained using this
reduction package.
[2]
oai:arXiv.org:1006.3102 [pdf] - 190657
The Fibre Multi-Object Spectrograph (FMOS) for Subaru Telescope
Kimura, Masahiko;
Maihara, Toshinori;
Iwamuro, Fumihide;
Akiyama, Masayuki;
Tamura, Naoyuki;
Dalton, Gavin B.;
Takato, Naruhisa;
Tait, Philip;
Ohta, Kouji;
Eto, Shigeru;
Mochida, Daisaku;
Elms, Brian;
Kawate, Kaori;
Kurakami, Tomio;
Moritani, Yuuki;
Noumaru, Junichi;
Ohshima, Norio;
Sumiyoshi, Masanao;
Yabe, Kiyoto;
Brzeski, Jurek;
Farrell, Tony;
Frost, Gabriella;
Gillingham, Peter R.;
Haynes, Roger;
Moore, Anna M.;
Muller, Rolf;
Smedley, Scott;
Smith, Greg;
Bonfield, David G.;
Brooks, Charles B.;
Holmes, Alan R.;
Lake, Emma Curtis;
Lee, Hanshin;
Lewis, Ian J.;
Froud, Tim R.;
Tosh, Ian A.;
Woodhouse, Guy F.;
Blackburn, Colin;
Dipper, Nigel;
Murray, Graham;
Sharples, Ray;
Robertson, David J.
Submitted: 2010-06-15
Fibre Multi-Object Spectrograph (FMOS) is the first near-infrared instrument
with a wide field of view capable of acquiring spectra simultaneously from up
to 400 objects. It has been developed as a common-use instrument for the F/2
prime-focus of the Subaru Telescope. The field coverage of 30' diameter is
achieved using a new 3-element corrector optimized in the near-infrared
(0.9-1.8um) wavelength range. Due to limited space at the prime-focus, we have
had to develop a novel fibre positioner called "Echidna" together with two
OH-airglow suppressed spectrographs. FMOS consists of three subsystems: the
prime focus unit for IR, the fibre positioning system/connector units, and the
two spectrographs. After full systems integration, FMOS was installed on the
telescope in late 2007. Many aspects of performance were checked through
various test and engineering observations. In this paper, we present the
optical and mechanical components of FMOS and show the results of our on-sky
engineering observations to date.