sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Kaul, S. K.

Normalized to: Kaul, S.

13 article(s) in total. 43 co-authors, from 1 to 9 common article(s). Median position in authors list is 13,0.

[1]  oai:arXiv.org:1808.02670  [pdf] - 1740107
Study of short term enhanced TeV $\gamma$- ray emission from Mrk 421 observed with TACTIC on December 28, 2014
Comments: 21 pages, 5 figures, Accepted for publication in Astroparticle Physics
Submitted: 2018-08-08
In this work, we report on the detection of enhanced TeV gamma- ray emission from the high synchrotron-peaked blazar Mrk 421 with the TACTIC telescope on the night of December 28, 2014 (MJD 57019). We use data from the TACTIC observations of Mrk 421 for one week during December 25-31, 2014 (MJD 57016-57022) in this study. The TACTIC observation on December 28, 2014 (MJD 57019) alone results in the detection of 86+-17 gamma- ray like events from Mrk 421 with a statistical significance of 5.17sigma in a livetime of ~ 2.2 hours above an energy threshold of 0.85 TeV. The high statistics (higher than three Crab Units) of TeV photons enables us to study the very high energy (VHE) gamma- ray emission from the source at shorter timescales. A minimum variability timescale of ~ 0.72 days is obtained for the TeV gamma- ray emission from Mrk 421 during the above flaring activity of the source. We have also analyzed the contemporaneous data from Fermi-LAT to study the high energy (HE) gamma- ray emission during the high activity state of the source. The HE gamma- ray emission is observed to be increasing after the TeV flaring activity detected with the TACTIC. We also use other near simultaneous archival data available from the Swift-BAT in hard X-rays and from SPOL at Steward Observatory in optical V and R bands to characterize the multi-wavelength emission of Mrk 421 during the high activity state observed at TeV energies. The TeV gamma- ray emission observed on December 28, 2014 (MJD 57019) is found to be more prominant than the emissions in lower energy bands during the same period. The TeV gamma- ray observation of Mrk 421 in high activity state with the TACTIC telescope is also used to understand the physical mechanism for blazar emission under the frame work of the leptonic single zone synchrotron self Compton process.
[2]  oai:arXiv.org:1701.04935  [pdf] - 1534697
Multiwavelength study of VHE emission from Markarian 501 using TACTIC observations during April-May, 2012
Comments: 10
Submitted: 2017-01-17
We have observed Markarian 501 in Very High Energy (VHE) gamma-ray wavelength band for 70.6 hours from 15 April to 30 May, 2012 using TACTIC telescope. Detailed analysis of $\sim$66.3 hours of clean data revealed the presence of a TeV $\gamma$-ray signal (686$\pm$77 $\gamma$-ray events) from the source direction with a statistical significance of 8.89$\sigma$ above 850 GeV. Further, a total of 375 $\pm$ 47 $\gamma$-ray like events were detected in 25.2 hours of observation from 22 - 27 May, 2012 with a statistical significance of 8.05$\sigma$ indicating that the source has possibly switched over to a relatively high gamma-ray emission state. We have derived time-averaged differential energy spectrum of the state in the energy range 850 GeV - 17.24 TeV which fits well with a power law function of the form $dF/dE=f_{0}E^{-\Gamma}$ with $f_{0}= (2.27 \pm 0.38) \times 10 ^{-11} $ photons cm$^{-2}$ s$^{-1}$ TeV$^{-1}$ and $\Gamma=2.57 \pm 0.15$. In order to investigate the source state, we have also used almost simultaneous multiwavelength observations viz: high energy data collected by $\it{Fermi}$-LAT, X-ray data collected by $\it{Swift}$-XRT and MAXI, optical and UV data collected by $\it{Swift}$-UVOT, and radio data collected by OVRO, and reconstructed broad-band Spectral Energy Distribution (SED). The obtained SED supports leptonic model (homogeneous single zone) for VHE gamma-ray emission involving synchrotron and synchrotron self Compton (SSC) processes.
[3]  oai:arXiv.org:1410.2369  [pdf] - 1222484
Search for TeV $\gamma$--ray emission from blazar 1ES1218+304 with TACTIC telescope during March-April 2013
Comments: Accepted for Publication in New Astronomy
Submitted: 2014-10-09
In this paper, we present results of TeV $\gamma$--ray observations of the high synchrotron peaked BL Lac object 1ES 1218+304 (z=0.182) with the $TACTIC$ (TeV Atmospheric Cherenkov Telescope with Imaging Camera). The observations are primarily motivated by the unusually hard GeV-TeV spectrum of the source despite its relatively large redshift. The source is observed in the TeV energy range with the $TACTIC$ from March 1, 2013 to April 15, 2013 (MJD 56352--56397) for a total observation time of 39.62 h and no evidence of TeV $\gamma$--ray activity is found from the source. The corresponding 99$\%$ confidence level upper limit on the integral flux above a threshold energy of 1.1 TeV is estimated to be 3.41 $\times10^{-12}$ photons cm$^{-2}$ s$^{-1}$ (i.e $<23\%$ Crab Nebula flux) assuming a power law differential energy spectrum with photon index 3.0, as previously observed by the $MAGIC$ and $VERITAS$ telescopes. For the study of multi-wavelength emission from the source, we use nearly simultaneous optical, UV and and X--ray data collected by the UVOT and XRT instruments on board the \emph{Swift} satellite and high energy $\gamma$--ray data collected by the Large Area Telescope on board the \emph{Fermi} satellite. We also use radio data at 15 GHz from OVRO 40 m telescope in the same period. No significant increase of activity is detected from radio to TeV $\gamma$--rays from 1ES1218+304 during the period from March 1, 2013 to April 15, 2013.
[4]  oai:arXiv.org:1202.2984  [pdf] - 1116620
TeV Gamma-ray Observations of Markarian 421 using TACTIC during 2009-10
Comments: 15 pages, 7 figures: Accepted for publication in J. Phys. G: Nucl. Part. Phys
Submitted: 2012-02-14
We have observed the blazar Markarian 421 with the TACTIC $\gamma$-ray telescope at Mt. Abu, India, from 22 November 2009 to 16 May 2010 for 265 hours. Detailed analysis of the data so recorded revealed presence of a TeV $\gamma$-ray signal with a statistical significance of 12.12$\sigma$ at $E_{\gamma}\geq$ 1 TeV. We have estimated the time averaged differential energy spectrum of the source in the energy range 1.0 - 16.44 TeV. The spectrum fits well with the power law function of the form ($dF/dE=f_0 E^{-\Gamma}$) with $f_0=(1.39\pm0.239)\times 10^{-11}cm^{-2}s^{-1}TeV^{-1}$ and $\Gamma=2.31\pm0.14$.
[5]  oai:arXiv.org:0911.3717  [pdf] - 1018430
Artificial Neural Network-based error compensation procedure for low-cost encoders
Comments: 16 pages, 4 figures. Accepted for Publication in Measurement Science and Technology (MST)
Submitted: 2009-11-19
An Artificial Neural Network-based error compensation method is proposed for improving the accuracy of resolver-based 16-bit encoders by compensating for their respective systematic error profiles. The error compensation procedure, for a particular encoder, involves obtaining its error profile by calibrating it on a precision rotary table, training the neural network by using a part of this data and then determining the corrected encoder angle by subtracting the ANN-predicted error from the measured value of the encoder angle. Since it is not guaranteed that all the resolvers will have exactly similar error profiles because of the inherent differences in their construction on a micro scale, the ANN has been trained on one error profile at a time and the corresponding weight file is then used only for compensating the systematic error of this particular encoder. The systematic nature of the error profile for each of the encoders has also been validated by repeated calibration of the encoders over a period of time and it was found that the error profiles of a particular encoder recorded at different epochs show near reproducible behavior. The ANN-based error compensation procedure has been implemented for 4 encoders by training the ANN with their respective error profiles and the results indicate that the accuracy of encoders can be improved by nearly an order of magnitude from quoted values of ~6 arc-min to ~0.65 arc-min when their corresponding ANN-generated weight files are used for determining the corrected encoder angle.
[6]  oai:arXiv.org:0706.2055  [pdf] - 2215
The TACTIC atmospheric Cherenkov Imaging telescope
Comments: 27 pages, 13 figures, accepted for publication in NIM A
Submitted: 2007-06-14
The TACTIC $\gamma$-ray telescope, equipped with a light collector of area $\sim$9.5m$^2$ and a medium resolution imaging camera of 349-pixels, has been in operation at Mt.Abu, India since 2001. This paper describes the main features of its various subsystems and its overall performance with regard to (a) tracking accuracy of its 2-axes drive system, (b) spot size of the light collector, (c) back-end signal processing electronics and topological trigger generation scheme, (d) data acquisition and control system and (e) relative and absolute gain calibration methodology. Using a trigger field of view of 11$\times$11 pixels ($\sim$ 3.4$^\circ$$\times3.4^\circ$), the telescope records a cosmic ray event rate of $\sim$2.5 Hz at a typical zenith angle of 15$^\circ$. Monte Carlo simulation results are also presented in the paper for comparing the expected performance of the telescope with actual observational results. The consistent detection of a steady signal from the Crab Nebula above $\sim$1.2 TeV energy, at a sensitivity level of $\sim5.0\sigma$ in $\sim$25 h, alongwith excellent matching of its energy spectrum with that obtained by other groups, reassures that the performance of the TACTIC telescope is quite stable and reliable. Furthermore, encouraged by the detection of strong $\gamma$-ray signals from Mrk 501 (during 1997 and 2006 observations) and Mrk 421 (during 2001 and 2005-2006 observations), we believe that there is considerable scope for the TACTIC telescope to monitor similar TeV $\gamma$-ray emission activity from other active galactic nuclei on a long term basis.
[7]  oai:arXiv.org:0706.2055  [pdf] - 2215
The TACTIC atmospheric Cherenkov Imaging telescope
Comments: 27 pages, 13 figures, accepted for publication in NIM A
Submitted: 2007-06-14
The TACTIC $\gamma$-ray telescope, equipped with a light collector of area $\sim$9.5m$^2$ and a medium resolution imaging camera of 349-pixels, has been in operation at Mt.Abu, India since 2001. This paper describes the main features of its various subsystems and its overall performance with regard to (a) tracking accuracy of its 2-axes drive system, (b) spot size of the light collector, (c) back-end signal processing electronics and topological trigger generation scheme, (d) data acquisition and control system and (e) relative and absolute gain calibration methodology. Using a trigger field of view of 11$\times$11 pixels ($\sim$ 3.4$^\circ$$\times3.4^\circ$), the telescope records a cosmic ray event rate of $\sim$2.5 Hz at a typical zenith angle of 15$^\circ$. Monte Carlo simulation results are also presented in the paper for comparing the expected performance of the telescope with actual observational results. The consistent detection of a steady signal from the Crab Nebula above $\sim$1.2 TeV energy, at a sensitivity level of $\sim5.0\sigma$ in $\sim$25 h, alongwith excellent matching of its energy spectrum with that obtained by other groups, reassures that the performance of the TACTIC telescope is quite stable and reliable. Furthermore, encouraged by the detection of strong $\gamma$-ray signals from Mrk 501 (during 1997 and 2006 observations) and Mrk 421 (during 2001 and 2005-2006 observations), we believe that there is considerable scope for the TACTIC telescope to monitor similar TeV $\gamma$-ray emission activity from other active galactic nuclei on a long term basis.
[8]  oai:arXiv.org:astro-ph/9906128  [pdf] - 106849
Observations of the Crab Nebula, Mkn 501 and Mkn 421 using the TACTIC Imaging Element
Comments: 3 pages, 1 Figure, to be presented in the 26th ICRC1999: OG 2.4.20
Submitted: 1999-06-08
The results of our observational campaigns on the two extragalactic sources Mkn 501 and Mkn 421, carried out with the Imaging Element of the TACTIC array, during March-May, 1998 and April-May, 1999, are presented. The results indicate that the two BL Lac objects (Mkn 501 and Mkn 421) were in a `low' gamma-ray emission state during both epochs of our observations.
[9]  oai:arXiv.org:astro-ph/9906128  [pdf] - 106849
Observations of the Crab Nebula, Mkn 501 and Mkn 421 using the TACTIC Imaging Element
Comments: 3 pages, 1 Figure, to be presented in the 26th ICRC1999: OG 2.4.20
Submitted: 1999-06-08
The results of our observational campaigns on the two extragalactic sources Mkn 501 and Mkn 421, carried out with the Imaging Element of the TACTIC array, during March-May, 1998 and April-May, 1999, are presented. The results indicate that the two BL Lac objects (Mkn 501 and Mkn 421) were in a `low' gamma-ray emission state during both epochs of our observations.