Normalized to: Kathiravan, S.
[1]
oai:arXiv.org:2002.01159 [pdf] - 2069029
Additional Calibration of the Ultra-Violet Imaging Telescope on board
AstroSat
Tandon, S. N.;
Postma, J.;
Joseph, P.;
Devaraj, A.;
Subramaniam, A;
Barve, I. V.;
George, K.;
Ghosh, S. K.;
Girish, V.;
Hutchings, J. B.;
Kamath, P. U.;
Kathiravan, S.;
Kumar, A.;
Lancelot, J. P.;
Leahy, D.;
Mahesh, P. K.;
Mohan, R.;
Nagabhushana, S.;
Pati, A. K.;
Rao, N. Kameswara;
Sankarasubramanian, K.;
Sriram, S.;
Stalin, C. S.
Submitted: 2020-02-04
Results of the initial calibration of the Ultra-Violet Imaging Telescope
(UVIT) were reported earlier by Tandon et al. (2017). The results reported
earlier were based on the ground calibration as well as the first observations
in orbit. Some additional data from the ground calibration and data from more
in-orbit observations have been used to improve the results. In particular,
extensive new data from in-orbit observations have been used to obtain (a) new
photometric calibration which includes (i) zero-points (ii) flat fields (iii)
saturation, (b) sensitivity variations (c) spectral calibration for the near
Ultra Violet (NUV; 2000 - 3000 Angstroms) and far Ultra-Violet (FUV; 1300 -
1800 Angstroms) gratings, (d) point spread function and (e) astrometric
calibration which included distortion. Data acquired over the last three years
show continued good performance of UVIT with no reduction in sensitivity in
both the UV channels.
[2]
oai:arXiv.org:1903.07333 [pdf] - 1859154
Prospect for UV observations from the Moon. III. Assembly and ground
calibration of Lunar Ultraviolet Cosmic Imager (LUCI)
Mathew, Joice;
Nair, B. G.;
Safonova, Margarita;
Sriram, S.;
Prakash, Ajin;
Sarpotdar, Mayuresh;
Ambily, S.;
K., Nirmal;
Sreejith, A. G.;
Murthy, Jayant;
Kamath, P. U.;
Kathiravan, S.;
Prasad, B. R.;
Brosch, Noah;
Kappelmann, Norbert;
Gadde, Nirmal Suraj;
Narayan, Rahul
Submitted: 2019-03-18, last modified: 2019-04-01
The Lunar Ultraviolet Cosmic Imager (LUCI) is a near-ultraviolet (NUV)
telescope with all-spherical mirrors, designed and built to fly as a scientific
payload on a lunar mission with Team Indus - the original Indian entry to the
Google Lunar X-Prize. Observations from the Moon provide a unique opportunity
of a stable platform with an unobstructed view of the space at all wavelengths
due to the absence of atmosphere and ionosphere. LUCI is an 80 mm aperture
telescope, with a field of view of 27.6'x 20.4' and a spatial resolution of
5'', will scan the sky in the NUV (200-320 nm) domain to look for transient
sources. We describe here the assembly, alignment, and calibration of the
complete instrument. LUCI is now in storage in a class 1000 clean room and will
be delivered to our flight partner in readiness for flight.
[3]
oai:arXiv.org:1705.03715 [pdf] - 1583290
In-orbit Calibrations of the Ultra-Violet Imaging Telescope
Tandon, S. N.;
Subramaniam, Annapurni;
Girish, V.;
Postma, J.;
Sankarasubramanian, K.;
Sriram, S.;
Stalin, C. S.;
Mondal, C.;
Joseph, S. Sahu P.;
Hutchings, J.;
Ghosh, S. K.;
Barve, I. V.;
George, K.;
Kamath, P. U.;
Kathiravan, S.;
Kumar, A.;
Lancelot, J. P.;
Leahy, D.;
Mahesh, P. K.;
Mohan, R.;
Nagabhushana, S.;
Pati, A. K.;
Rao, N. Kameswara;
Sreedhar, Y. H.;
Sreekumar, P.
Submitted: 2017-05-10, last modified: 2017-08-05
The Ultra-Violet Imaging Telescope (UVIT) is one of the payloads in ASTROSAT,
the first Indian Space Observatory. The UVIT instrument has two 375mm
telescopes: one for the far-ultraviolet (FUV) channel (1300--1800\AA), and the
other for the near-ultraviolet (NUV) channel (2000--3000\AA) and the visible
(VIS) channel (3200--5500\AA). UVIT is primarily designed for simultaneous
imaging in the two ultraviolet channels with spatial resolution better than 1.8
arcsec, along with provision for slit-less spectroscopy in the NUV and FUV
channels.The results of in-orbit calibrations of UVIT are presented in this
paper.
[4]
oai:arXiv.org:1612.00612 [pdf] - 1580790
In-orbit Performance of UVIT and First Results
Tandon, S. N.;
Hutchings, J. B.;
Ghosh, S. K.;
Subramaniam, A.;
Koshy, G.;
Girish, V.;
Kamath, P. U.;
Kathiravan, s.;
Kumar, A.;
Lancelot, J. P.;
Mahesh, P. K.;
Mohan, R.;
Murthy, J.;
Nagabhushana, S.;
A, A. K. Pati;
Postma, J.;
Rao, N. Kameswara;
Sankarasubramanian, K.;
Sreekumar, P.;
Sriram, S.;
Stalin, C. S.;
Sutaria, F.;
Sreedhar, Y. H.;
Barve, I. V.;
Mondal, C.;
Sahu, S.
Submitted: 2016-12-02
The performance of the ultraviolet telescope (UVIT) on-board ASTROSAT is
reported. The performance in orbit is also compared with estimates made from
the calibrations done on the ground. The sensitivity is found to be within ~15%
of the estimates, and the spatial resolution in the NUV is found to exceed
significantly the design value of 1.8 arcsec and it is marginally better in the
FUV. Images obtained from UVIT are presented to illustrate the details revealed
by the high spatial resolution. The potential of multi-band observations in the
ultraviolet with high spatial resolution is illustrated by some results.
[5]
oai:arXiv.org:1608.01073 [pdf] - 1521281
In-orbit Performance of UVIT on ASTROSAT
Subramaniam, Annapurni;
Tandon, Shyam N.;
Hutchings, John;
Ghosh, Swarna K.;
George, Koshy;
Girish, V.;
Kamath, P. U.;
Kathiravan, S.;
Kumar, Amit;
Lancelot, J. Paul;
Mahesh, P. K.;
Mohan, Rekhesh;
Murthy, Jayant;
Nagabhushana, S.;
Pati, Ashok K.;
Postma, Joe;
Rao, N. Kameswara;
Sankarasubramanian, Kasiviswanathan;
Sreekumar, P.;
Sriram, S.;
Stalin, Chelliah S.;
Sutaria, Firoza;
Sreedhar, Yuvraj Harsha;
Barve, Indrajit V.;
Mondal, Chayan;
Sahu, Snehalata
Submitted: 2016-08-03
We present the in-orbit performance and the first results from the
ultra-violet Imaging telescope (UVIT) on ASTROSAT. UVIT consists of two
identical 38cm coaligned telescopes, one for the FUV channel (130-180nm) and
the other for the NUV (200-300nm) and VIS (320-550nm) channels, with a field of
view of 28 $arcmin$. The FUV and the NUV detectors are operated in the high
gain photon counting mode whereas the VIS detector is operated in the low gain
integration mode. The FUV and NUV channels have filters and gratings, whereas
the VIS channel has filters. The ASTROSAT was launched on 28th September 2015.
The performance verification of UVIT was carried out after the opening of the
UVIT doors on 30th November 2015, till the end of March 2016 within the
allotted time of 50 days for calibration. All the on-board systems were found
to be working satisfactorily. During the PV phase, the UVIT observed several
calibration sources to characterise the instrument and a few objects to
demonstrate the capability of the UVIT. The resolution of the UVIT was found to
be about 1.4 - 1.7 $arcsec$ in the FUV and NUV. The sensitivity in various
filters were calibrated using standard stars (white dwarfs), to estimate the
zero-point magnitudes as well as the flux conversion factor. The gratings were
also calibrated to estimate their resolution as well as effective area. The
sensitivity of the filters were found to be reduced up to 15\% with respect to
the ground calibrations. The sensitivity variation is monitored on a monthly
basis. UVIT is all set to roll out science results with its imaging capability
with good resolution and large field of view, capability to sample the UV
spectral region using different filters and capability to perform variability
studies in the UV.
[6]
oai:arXiv.org:1208.4670 [pdf] - 1150850
Ultra Violet Imaging Telescope (UVIT) on ASTROSAT
Kumar, Amit;
Ghosh, S. K.;
Hutchings, J.;
Kamath, P. U.;
Kathiravan, S.;
Mahesh, P. K.;
Murthy, J.;
S, Nagbhushana.;
Pati, A. K.;
Rao, M. N.;
Rao, N. K.;
Sriram, S.;
Tandon, S. N.
Submitted: 2012-08-23
Ultra Violet Imaging Telescope on ASTROSAT Satellite mission is a suite of
Far Ultra Violet (FUV 130 to 180 nm), Near Ultra Violet (NUV 200 to 300 nm) and
Visible band (VIS 320 to 550nm) imagers. ASTROSAT is the first multi wavelength
mission of INDIA. UVIT will image the selected regions of the sky
simultaneously in three channels and observe young stars, galaxies, bright UV
Sources. FOV in each of the 3 channels is about 28 arc-minute. Targeted angular
resolution in the resulting UV images is better than 1.8 arc-second (better
than 2.0 arc-second for the visible channel). Two identical co-aligned
telescopes (T1, T2) of Ritchey-Chretien configuration (Primary mirror of 375 mm
diameter) collect celestial radiation and feed to the detector system via a
selectable filter on a filter wheel mechanism; gratings are available in filter
wheels of FUV and NUV channels for slit-less low resolution spectroscopy. The
detector system for each of the 3 channels is generically identical. One of the
telescopes images in the FUV channel, while the other images in NUV and VIS
channels. Images from VIS channel are also used for measuring drift for
reconstruction of images on ground through shift and add algorithm, and to
reconstruct absolute aspect of the images. Adequate baffling has been provided
for reducing scattered background from the Sun, earth albedo and other bright
objects. One time open-able mechanical cover on each telescope also works as a
Sun-shield after deployment. We are presenting here the overall (mechanical,
optical and electrical) design of the payload.
[7]
oai:arXiv.org:1208.4672 [pdf] - 1150851
Tests & Calibration on Ultra Violet Imaging Telescope (UVIT)
Kumar, Amit;
Ghosh, S. K.;
Kamath, P. U.;
Postma, Joe;
Kathiravan, S.;
Mahesh, P. K.;
S, Nagbhushana.;
Navalgund, K. H.;
Rajkumar, N;
Rao, M. N.;
Sarma, K. S.;
Sriram, S.;
Stalin, C. S.;
Tandon, S. N.
Submitted: 2012-08-23
Ultra Violet Imaging Telescope on ASTROSAT Satellite mission is a suite of
Far Ultra Violet (FUV; 130 to 180 nm), Near Ultra Violet (NUV; 200 to 300 nm)
and Visible band (VIS; 320 to 550nm) imagers. ASTROSAT is a first multi
wavelength mission of INDIA. UVIT will image the selected regions of the sky
simultaneously in three channels & observe young stars, galaxies, bright UV
Sources. FOV in each of the 3 channels is about 28 arc-minute. Targeted angular
resolution in the resulting UV images is better than 1.8 arc-second (better
than 2.0 arc-second for the visible channel). Two identical co-aligned
telescopes (T1, T2) of Ritchey-Chretien configuration (Primary mirror of 375 mm
diameter) collect the celestial radiation and feed to the detector system via a
selectable filter on a filter wheel mechanism; gratings are available in the
filter wheels of FUV and NUV channels for slit-less low resolution
spectroscopy. The detector system for each of the 3 channels is generically
identical. One telescope images in the FUV channel, and other images in NUV and
VIS channels. One time open-able mechanical cover on each telescope also works
as Sun-shield after deployment.We will present the optical tests and
calibrations done on the two telescopes. Results on vibrations test and
thermo-vacuum tests on the engineering model will also be presented.