Normalized to: Kastens, L.
[1]
oai:arXiv.org:1310.8214 [pdf] - 795009
First results from the LUX dark matter experiment at the Sanford
Underground Research Facility
LUX Collaboration;
Akerib, D. S.;
Araujo, H. M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Bedikian, S.;
Bernard, E.;
Bernstein, A.;
Bolozdynya, A.;
Bradley, A.;
Byram, D.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Chan, C.;
Chapman, J. J.;
Chiller, A. A.;
Chiller, C.;
Clark, K.;
Coffey, T.;
Currie, A.;
Curioni, A.;
Dazeley, S.;
de Viveiros, L.;
Dobi, A.;
Dobson, J.;
Dragowsky, E. M.;
Druszkiewicz, E.;
Edwards, B.;
Faham, C. H.;
Fiorucci, S.;
Flores, C.;
Gaitskell, R. J.;
Gehman, V. M.;
Ghag, C.;
Gibson, K. R.;
Gilchriese, M. G. D.;
Hall, C.;
Hanhardt, M.;
Hertel, S. A.;
Horn, M.;
Huang, D. Q.;
Ihm, M.;
Jacobsen, R. G.;
Kastens, L.;
Kazkaz, K.;
Knoche, R.;
Kyre, S.;
Lander, R.;
Larsen, N. A.;
Lee, C.;
Leonard, D. S.;
Lesko, K. T.;
Lindote, A.;
Lopes, M. I.;
Lyashenko, A.;
Malling, D. C.;
Mannino, R.;
McKinsey, D. N.;
Mei, D. -M.;
Mock, J.;
Moongweluwan, M.;
Morad, J.;
Morii, M.;
Murphy, A. St. J.;
Nehrkorn, C.;
Nelson, H.;
Neves, F.;
Nikkel, J. A.;
Ott, R. A.;
Pangilinan, M.;
Parker, P. D.;
Pease, E. K.;
Pech, K.;
Phelps, P.;
Reichhart, L.;
Shutt, T.;
Silva, C.;
Skulski, W.;
Sofka, C. J.;
Solovov, V. N.;
Sorensen, P.;
Stiegler, T.;
O`Sullivan, K.;
Sumner, T. J.;
Svoboda, R.;
Sweany, M.;
Szydagis, M.;
Taylor, D.;
Tennyson, B.;
Tiedt, D. R.;
Tripathi, M.;
Uvarov, S.;
Verbus, J. R.;
Walsh, N.;
Webb, R.;
White, J. T.;
White, D.;
Witherell, M. S.;
Wlasenko, M.;
Wolfs, F. L. H.;
Woods, M.;
Zhang, C.
Submitted: 2013-10-30, last modified: 2014-02-05
The Large Underground Xenon (LUX) experiment, a dual-phase xenon
time-projection chamber operating at the Sanford Underground Research Facility
(Lead, South Dakota), was cooled and filled in February 2013. We report results
of the first WIMP search dataset, taken during the period April to August 2013,
presenting the analysis of 85.3 live-days of data with a fiducial volume of 118
kg. A profile-likelihood analysis technique shows our data to be consistent
with the background-only hypothesis, allowing 90% confidence limits to be set
on spin-independent WIMP-nucleon elastic scattering with a minimum upper limit
on the cross section of $7.6 \times 10^{-46}$ cm$^{2}$ at a WIMP mass of 33
GeV/c$^2$. We find that the LUX data are in strong disagreement with low-mass
WIMP signal interpretations of the results from several recent direct detection
experiments.
[2]
oai:arXiv.org:1205.2272 [pdf] - 873784
An Ultra-Low Background PMT for Liquid Xenon Detectors
Akerib, D. S.;
Bai, X.;
Bernard, E.;
Bernstein, A.;
Bradley, A.;
Byram, D.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Carr, D.;
Chapman, J. J.;
Chan, Y-D.;
Clark, K.;
Coffey, T.;
deViveiros, L.;
Dragowsky, M.;
Druszkiewicz, E.;
Edwards, B.;
Faham, C. H.;
Fiorucci, S.;
Gaitskell, R. J.;
Gibson, K. R.;
Hall, C.;
Hanhardt, M.;
Holbrook, B.;
Ihm, M.;
Jacobsen, R. G.;
Kastens, L.;
Kazkaz, K.;
Larsen, N.;
Lee, C.;
Lesko, K.;
Lindote, A.;
Lopes, M. I.;
Lyashenko, A.;
Malling, D. C.;
Mannino, R.;
McKinsey, D.;
Mei, D.;
Mock, J.;
Morii, M.;
Nelson, H.;
Neves, F.;
Nikkel, J. A.;
Pangilinan, M.;
Pech, K.;
Phelps, P.;
Shutt, T.;
Silva, C.;
Skulski, W.;
Solovov, V. N.;
Sorensen, P.;
Spaans, J.;
Stiegler, T.;
Sweany, M.;
Szydagis, M.;
Taylor, D.;
Thomson, J.;
Tripathi, M.;
Uvarov, S.;
Verbus, J. R.;
Walsh, N.;
Webb, R.;
White, J. T.;
Wlasenko, M.;
Wolfs, F. L. H.;
Woods, M.;
Zhang, C.
Submitted: 2012-05-10, last modified: 2013-06-24
Results are presented from radioactivity screening of two models of
photomultiplier tubes designed for use in current and future liquid xenon
experiments. The Hamamatsu 5.6 cm diameter R8778 PMT, used in the LUX dark
matter experiment, has yielded a positive detection of four common radioactive
isotopes: 238U, 232Th, 40K, and 60Co. Screening of LUX materials has rendered
backgrounds from other detector materials subdominant to the R8778
contribution. A prototype Hamamatsu 7.6 cm diameter R11410 MOD PMT has also
been screened, with benchmark isotope counts measured at <0.4 238U / <0.3 232Th
/ <8.3 40K / 2.0+-0.2 60Co mBq/PMT. This represents a large reduction, equal to
a change of \times 1/24 238U / \times 1/9 232Th / \times 1/8 40K per PMT,
between R8778 and R11410 MOD, concurrent with a doubling of the photocathode
surface area (4.5 cm to 6.4 cm diameter). 60Co measurements are comparable
between the PMTs, but can be significantly reduced in future R11410 MOD units
through further material selection. Assuming PMT activity equal to the measured
90% upper limits, Monte Carlo estimates indicate that replacement of R8778 PMTs
with R11410 MOD PMTs will change LUX PMT electron recoil background
contributions by a factor of \times1/25 after further material selection for
60Co reduction, and nuclear recoil backgrounds by a factor of \times 1/36. The
strong reduction in backgrounds below the measured R8778 levels makes the
R11410 MOD a very competitive technology for use in large-scale liquid xenon
detectors.
[3]
oai:arXiv.org:1104.3088 [pdf] - 661239
A search for light dark matter in XENON10 data
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
Dahl, C. E.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Sorensen, P.;
Schulte, S.;
Winant, C.;
Yamashita, M.
Submitted: 2011-04-15, last modified: 2013-05-07
We report results of a search for light (<10 GeV) particle dark matter with
the XENON10 detector. The event trigger was sensitive to a single electron,
with the analysis threshold of 5 electrons corresponding to 1.4 keV nuclear
recoil energy. Considering spin-independent dark matter-nucleon scattering, we
exclude cross sections \sigma_n>3.5x10^{-42} cm^2, for a dark matter particle
mass m_{\chi}=8 GeV. We find that our data strongly constrain recent elastic
dark matter interpretations of excess low-energy events observed by CoGeNT and
CRESST-II, as well as the DAMA annual modulation signal.
[4]
oai:arXiv.org:1210.4569 [pdf] - 630139
Technical Results from the Surface Run of the LUX Dark Matter Experiment
LUX Collaboration;
Akerib, D. S.;
Bai, X.;
Bernard, E.;
Bernstein, A.;
Bradley, A.;
Byram, D.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Chapman, J. J.;
Coffey, T.;
Dobi, A.;
Dragowsky, E.;
Druszkiewicz, E.;
Edwards, B.;
Faham, C. H.;
Fiorucci, S.;
Gaitskell, R. J.;
Gibson, K. R.;
Gilchriese, M.;
Hall, C.;
Hanhardt, M.;
Ihm, M.;
Jacobsen, R. G.;
Kastens, L.;
Kazkaz, K.;
Knoche, R.;
Larsen, N.;
Lee, C.;
Lesko, K. T.;
Lindote, A.;
Lopes, M. I.;
Lyashenko, A.;
Malling, D. C.;
Mannino, R.;
McKinsey, D. N.;
Mei, D.;
Mock, J.;
Moongweluwan, M.;
Morii, M.;
Nelson, H.;
Neves, F.;
Nikkel, J. A.;
Pangilinan, M.;
Pech, K.;
Phelps, P.;
Rodionov, A.;
Shutt, T.;
Silva, C.;
Skulski, W.;
Solovov, V. N.;
Sorensen, P.;
Stiegler, T.;
Sweany, M.;
Szydagis, M.;
Taylor, D.;
Tripathi, M.;
Uvarov, S.;
Verbus, J. R.;
de Viveiros, L.;
Walsh, N.;
Webb, R.;
White, J. T.;
Wlasenko, M.;
Wolfs, F. L. H.;
Woods, M.;
Zhang, C.
Submitted: 2012-10-16, last modified: 2013-02-22
We present the results of the three-month above-ground commissioning run of
the Large Underground Xenon (LUX) experiment at the Sanford Underground
Research Facility located in Lead, South Dakota, USA. LUX is a 370 kg liquid
xenon detector that will search for cold dark matter in the form of Weakly
Interacting Massive Particles (WIMPs). The commissioning run, conducted with
the detector immersed in a water tank, validated the integration of the various
sub-systems in preparation of the underground deployment. Using the data
collected, we report excellent light collection properties, achieving 8.4
photoelectrons per keV for 662 keV electron recoils without an applied electric
field, measured in the center of the WIMP target. We also find good energy and
position resolution in relatively high-energy interactions from a variety of
internal and external sources. Finally, we have used the commissioning data to
tune the optical properties of our simulation and report updated sensitivity
projections for spin-independent WIMP-nucleon scattering.
[5]
oai:arXiv.org:1207.3665 [pdf] - 1124847
The LUX Prototype Detector: Heat Exchanger Development
Akerib, D. S.;
Bai, X.;
Bedikian, S.;
Bernstein, A.;
Bolozdynya, A.;
Bradley, A.;
Cahn, S.;
Carr, D.;
Chapman, J. J.;
Clark, K.;
Classen, T.;
Curioni, A.;
Dahl, C. E.;
Dazeley, S.;
deViveiros, L.;
Dragowsky, M.;
Druszkiewicz, E.;
Fiorucci, S.;
Gaitskell, R. J.;
Hall, C.;
Faham, C.;
Holbrook, B.;
Kastens, L.;
Kazkaz, K.;
Kwong, J.;
Lander, R.;
Leonard, D.;
Malling, D.;
Mannino, R.;
McKinsey, D. N.;
Mei, D.;
Mock, J.;
Morii, M.;
Nikkel, J.;
Phelps, P.;
Shutt, T.;
Skulski, W.;
Sorensen, P.;
Spaans, J.;
Steigler, T.;
Svoboda, R.;
Sweany, M.;
Thomson, J.;
Tripathi, M.;
Walsh, N.;
Webb, R.;
White, J.;
Wolfs, F. L. H.;
Woods, M.;
Zhang, C.
Submitted: 2012-07-16, last modified: 2013-01-20
The LUX (Large Underground Xenon) detector is a two-phase xenon Time
Projection Chamber (TPC) designed to search for WIMP-nucleon dark matter
interactions. As with all noble element detectors, continuous purification of
the detector medium is essential to produce a large ($>$1ms) electron lifetime;
this is necessary for efficient measurement of the electron signal which in
turn is essential for achieving robust discrimination of signal from background
events. In this paper we describe the development of a novel purification
system deployed in a prototype detector. The results from the operation of this
prototype indicated heat exchange with an efficiency above 94% up to a flow
rate of 42 slpm, allowing for an electron drift length greater than 1 meter to
be achieved in approximately two days and sustained for the duration of the
testing period.
[6]
oai:arXiv.org:1110.0103 [pdf] - 967104
After LUX: The LZ Program
Malling, D. C.;
Akerib, D. S.;
Araujo, H. M.;
Bai, X.;
Bedikian, S.;
Bernard, E.;
Bernstein, A.;
Bradley, A.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Carr, D.;
Chapman, J. J.;
Clark, K.;
Classen, T.;
Coffey, T.;
Curioni, A.;
Currie, A.;
Dazeley, S.;
de Viveiros, L.;
Dragowsky, M.;
Druszkiewicz, E.;
Faham, C. H.;
Fiorucci, S.;
Gaitskell, R. J.;
Gibson, K. R.;
Hall, C.;
Hanhardt, M.;
Holbrook, B.;
Ihm, M.;
Jacobsen, R. G.;
Kastens, L.;
Kazkaz, K.;
Lander, R.;
Larsen, N.;
Lee, C.;
Leonard, D.;
Lesko, K.;
Lindote, A.;
Lopes, M. I.;
Lyashenko, A.;
Majewski, P.;
Mannino, R.;
McKinsey, D. N.;
Mei, D. -M.;
Mock, J.;
Morii, M.;
Murphy, A. St J.;
Nelson, H.;
Neves, F.;
Nikkel, J. A.;
Pangilinan, M.;
Phelps, P.;
Reichhart, L.;
Shutt, T.;
Silva, C.;
Skulski, W.;
Solovov, V.;
Sorensen, P.;
Spaans, J.;
Stiegler, T.;
Sumner, T. J.;
Svoboda, R.;
Sweany, M.;
Szydagis, M.;
Thomson, J.;
Tripathi, M.;
Verbus, J. R.;
Walsh, N.;
Webb, R.;
White, J. T.;
Wlasenko, M.;
Wolfs, F. L. H.;
Woods, M.;
Zhang, C.
Submitted: 2011-10-01, last modified: 2011-10-13
The LZ program consists of two stages of direct dark matter searches using
liquid Xe detectors. The first stage will be a 1.5-3 tonne detector, while the
last stage will be a 20 tonne detector. Both devices will benefit tremendously
from research and development performed for the LUX experiment, a 350 kg liquid
Xe dark matter detector currently operating at the Sanford Underground
Laboratory. In particular, the technology used for cryogenics and electrical
feedthroughs, circulation and purification, low-background materials and
shielding techniques, electronics, calibrations, and automated control and
recovery systems are all directly scalable from LUX to the LZ detectors.
Extensive searches for potential background sources have been performed, with
an emphasis on previously undiscovered background sources that may have a
significant impact on tonne-scale detectors. The LZ detectors will probe
spin-independent interaction cross sections as low as 5E-49 cm2 for 100 GeV
WIMPs, which represents the ultimate limit for dark matter detection with
liquid xenon technology.
[7]
oai:arXiv.org:1108.1836 [pdf] - 1083296
Data Acquisition and Readout System for the LUX Dark Matter Experiment
Akerib, D. S.;
Bai, X.;
Bedikian, S.;
Bernard, E.;
Bernstein, A.;
Bradley, A.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Carr, D.;
Chapman, J. J.;
Clark, K.;
Classen, T.;
Coffey, T.;
Curioni, A.;
Dazeley, S.;
deViveiros, L.;
Dragowsky, M.;
Druszkiewicz, E.;
Faham, C. H.;
Fiorucci, S.;
Gaitskell, R. J.;
Gibson, K. R.;
Hall, C.;
Hanhardt, M.;
Holbrook, B.;
Ihm, M.;
Jacobsen, R. G.;
Kastens, L.;
Kazkaz, K.;
Lander, R.;
Larsen, N.;
Lee, C.;
Leonard, D.;
Lesko, K.;
Lyashenko, A.;
Malling, D. C.;
Mannino, R.;
McKinsey, D. N.;
Mei, D.;
Mock, J.;
Morii, M.;
Nelson, H.;
Nikkel, J. A.;
Pangilinan, M.;
Phelps, P.;
Shutt, T.;
Skulski, W.;
Sorensen, P.;
Spaans, J.;
Stiegler, T.;
Svoboda, R.;
Sweany, M.;
Szydagis, M.;
Thomson, J.;
Tripathi, M.;
Verbus, J. R.;
Walsh, N.;
Webb, R.;
White, J. T.;
Wlasenko, M.;
Wolfs, F. L. H.;
Woods, M.;
Zhang, C.
Submitted: 2011-08-08, last modified: 2011-08-09
LUX is a two-phase (liquid/gas) xenon time projection chamber designed to
detect nuclear recoils from interactions with dark matter particles. Signals
from the LUX detector are processed by custom-built analog electronics which
provide properly shaped signals for the trigger and data acquisition (DAQ)
systems. The DAQ is comprised of commercial digitizers with firmware customized
for the LUX experiment. Data acquisition systems in rare-event searches must
accommodate high rate and large dynamic range during precision calibrations
involving radioactive sources, while also delivering low threshold for maximum
sensitivity. The LUX DAQ meets these challenges using real-time baseline sup-
pression that allows for a maximum event acquisition rate in excess of 1.5 kHz
with virtually no deadtime. This paper describes the LUX DAQ and the novel
acquisition techniques employed in the LUX experiment.
[8]
oai:arXiv.org:0910.3698 [pdf] - 270011
Constraints on inelastic dark matter from XENON10
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
Dahl, C. E.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Sorensen, P.;
Schulte, S.;
Winant, C.;
Yamashita, M.
Submitted: 2009-10-19, last modified: 2010-11-30
It has been suggested that dark matter particles which scatter inelastically
from detector target nuclei could explain the apparent incompatibility of the
DAMA modulation signal (interpreted as evidence for particle dark matter) with
the null results from CDMS-II and XENON10. Among the predictions of
inelastically interacting dark matter are a suppression of low-energy events,
and a population of nuclear recoil events at higher nuclear recoil equivalent
energies. This is in stark contrast to the well-known expectation of a falling
exponential spectrum for the case of elastic interactions. We present a new
analysis of XENON10 dark matter search data extending to E$_{nr}=75$ keV
nuclear recoil equivalent energy. Our results exclude a significant region of
previously allowed parameter space in the model of inelastically interacting
dark matter. In particular, it is found that dark matter particle masses
$m_{\chi}\gtrsim150$ GeV are disfavored.
[9]
oai:arXiv.org:1011.6439 [pdf] - 270289
Lowering the low-energy threshold of xenon detectors
Sorensen, P.;
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
Dahl, C. E.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Schulte, S.;
Winant, C.;
Yamashita, M.
Submitted: 2010-11-29
We show that the energy threshold for nuclear recoils in the XENON10 dark
matter search data can be lowered to ~1 keV, by using only the ionization
signal. In other words, we make no requirement that a valid event contain a
primary scintillation signal. We therefore relinquish incident particle type
discrimination, which is based on the ratio of ionization to scintillation in
liquid xenon. This method compromises the detector's ability to precisely
determine the z coordinate of a particle interaction. However, we show for the
first time that it is possible to discriminate bulk events from surface events
based solely on the ionization signal.
[10]
oai:arXiv.org:0909.1063 [pdf] - 142221
Scintillation efficiency and ionization yield of liquid xenon for
mono-energetic nuclear recoils down to 4 keV
Submitted: 2009-09-05, last modified: 2010-01-18
Liquid Xenon (LXe) is an excellent material for experiments designed to
detect dark matter in the form of Weakly Interacting Massive Particles (WIMPs).
A low energy detection threshold is essential for a sensitive WIMP search. The
understanding of the relative scintillation efficiency (Leff) and ionization
yield of low energy nuclear recoils in LXe is limited for energies below 10
keV. In this paper, we present new measurements that extend the energy down to
4 keV, finding that Leff decreases with decreasing energy. We also measure the
quenching of scintillation efficiency due to the electric field in LXe, finding
no significant field dependence.
[11]
oai:arXiv.org:1001.2834 [pdf] - 348097
Design and Performance of the XENON10 Dark Matter Experiment
Aprile, E.;
Angle, J.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
Dahl, C. E.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Orlandi, D.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Sorensen, P.;
Schulte, S.;
Tatananni, E.;
Winant, C.;
Yamashita, M.
Submitted: 2010-01-16
XENON10 is the first two-phase xenon time projection chamber (TPC) developed
within the XENON dark matter search program. The TPC, with an active liquid
xenon (LXe) mass of about 14 kg, was installed at the Gran Sasso underground
laboratory (LNGS) in Italy, and operated for more than one year, with excellent
stability and performance. Results from a dark matter search with XENON10 have
been published elsewhere. In this paper, we summarize the design and
performance of the detector and its subsystems, based on calibration data using
sources of gamma-rays and neutrons as well as background and Monte Carlo
simulations data. The results on the detector's energy threshold, energy and
position resolution, and overall efficiency show a performance that exceeds
design specifications, in view of the very low energy threshold achieved (<10
keVr) and the excellent energy resolution achieved by combining the ionization
and scintillation signals, detected simultaneously.
[12]
oai:arXiv.org:0905.1766 [pdf] - 24160
Calibration of a Liquid Xenon Detector with Kr-83m
Submitted: 2009-05-12, last modified: 2009-12-11
We report the preparation of a Kr-83m source and its subsequent use in
calibrating a liquid xenon detector. Kr-83m atoms were produced through the
decay of Rb-83 atoms trapped in zeolite molecular sieve and were then
introduced into liquid xenon. Decaying Kr-83m nuclei were detected through
liquid xenon scintillation. Conversion electrons with energies of 9.4 keV and
32.1 keV from the decay of Kr-83m were both observed. This calibration source
will allow the characterization of the scintillation and ionization response of
noble liquid detectors at low energies, highly valuable for the search for WIMP
dark matter. Kr-83m may also be useful for measuring fluid flow dynamics, both
to understand purification in noble liquid-based particle detectors, as well as
for studies of classical and quantum turbulence in superfluid helium.
[13]
oai:arXiv.org:0912.0482 [pdf] - 902613
Status of the LUX Dark Matter Search
Fiorucci, S.;
Akerib, D. S.;
Bedikian, S.;
Bernstein, A.;
Bolozdynya, A.;
Bradley, A.;
Carr, D.;
Chapman, J.;
Clark, K.;
Classen, T.;
Curioni, A.;
Dahl, E.;
Dazeley, S.;
de Viveiros, L.;
Druszkiewicz, E.;
Gaitskell, R.;
Hall, C.;
Faham, C. Hernandez;
Holbrook, B.;
Kastens, L.;
Kazkaz, K.;
Lander, R.;
Lesko, K.;
Malling, D.;
Mannino, R.;
McKinsey, D.;
Mei, D.;
Mock, J.;
Nikkel, J.;
Phelps, P.;
Schroeder, U.;
Shutt, T.;
Skulski, W.;
Sorensen, P.;
Spaans, J.;
Stiegler, T.;
Svoboda, R.;
Sweany, M.;
Thomson, J.;
Toke, J.;
Tripathi, M.;
Walsh, N.;
Webb, R.;
White, J.;
Wolfs, F.;
Woods, M.;
Zhang, C.
Submitted: 2009-12-02
The Large Underground Xenon (LUX) dark matter search experiment is currently
being deployed at the Homestake Laboratory in South Dakota. We will highlight
the main elements of design which make the experiment a very strong competitor
in the field of direct detection, as well as an easily scalable concept. We
will also present its potential reach for supersymmetric dark matter detection,
within various timeframes ranging from 1 year to 5 years or more.
[14]
oai:arXiv.org:0911.5453 [pdf] - 146838
Calibration of liquid argon and neon detectors with $^{83}Kr^m$
Submitted: 2009-11-30
We report results from tests of $^{83}$Kr$^{\mathrm{m}}$, as a calibration
source in liquid argon and liquid neon. $^{83}$Kr$^{\mathrm{m}}$ atoms are
produced in the decay of $^{83}$Rb, and a clear $^{83}$Kr$^{\mathrm{m}}$
scintillation peak at 41.5 keV appears in both liquids when filling our
detector through a piece of zeolite coated with $^{83}$Rb. Based on this
scintillation peak, we observe 6.0 photoelectrons/keV in liquid argon with a
resolution of 6% ($\sigma$/E) and 3.0 photoelectrons/keV in liquid neon with a
resolution of 19% ($\sigma$/E). The observed peak intensity subsequently decays
with the $^{83}$Kr$^{\mathrm{m}}$ half-life after stopping the fill, and we
find evidence that the spatial location of $^{83}$Kr$^{\mathrm{m}}$ atoms in
the chamber can be resolved. $^{83}$Kr$^{\mathrm{m}}$ will be a useful
calibration source for liquid argon and neon dark matter and solar neutrino
detectors.
[15]
oai:arXiv.org:0807.0459 [pdf] - 1937508
The scintillation and ionization yield of liquid xenon for nuclear
recoils
Sorensen, P.;
Manzur, A.;
Dahl, C. E.;
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Schulte, S.;
Winant, C.;
Yamashita, M.
Submitted: 2008-07-03, last modified: 2008-12-30
XENON10 is an experiment designed to directly detect particle dark matter. It
is a dual phase (liquid/gas) xenon time-projection chamber with 3D position
imaging. Particle interactions generate a primary scintillation signal (S1) and
ionization signal (S2), which are both functions of the deposited recoil energy
and the incident particle type. We present a new precision measurement of the
relative scintillation yield \leff and the absolute ionization yield Q_y, for
nuclear recoils in xenon. A dark matter particle is expected to deposit energy
by scattering from a xenon nucleus. Knowledge of \leff is therefore crucial for
establishing the energy threshold of the experiment; this in turn determines
the sensitivity to particle dark matter. Our \leff measurement is in agreement
with recent theoretical predictions above 15 keV nuclear recoil energy, and the
energy threshold of the measurement is 4 keV. A knowledge of the ionization
yield \Qy is necessary to establish the trigger threshold of the experiment.
The ionization yield \Qy is measured in two ways, both in agreement with
previous measurements and with a factor of 10 lower energy threshold.
[16]
oai:arXiv.org:0805.2939 [pdf] - 1937505
Limits on spin-dependent WIMP-nucleon cross-sections from the XENON10
experiment
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
Dahl, C. E.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Sorensen, P.;
Schulte, S.;
Winant, C.;
Yamashita, M.
Submitted: 2008-05-19, last modified: 2008-09-10
XENON10 is an experiment to directly detect weakly interacting massive
particle (WIMPs), which may comprise the bulk of the non-baryonic dark matter
in our Universe. We report new results for spin-dependent WIMP-nucleon
interactions with 129-Xe and 131-Xe from 58.6 live-days of operation at the
Laboratori Nazionali del Gran Sasso (LNGS). Based on the non-observation of a
WIMP signal in 5.4 kg of fiducial liquid xenon mass, we exclude previously
unexplored regions in the theoretically allowed parameter space for
neutralinos. We also exclude a heavy Majorana neutrino with a mass in the range
of 10 GeV -2 TeV as a dark matter candidate under standard assumptions for its
density and distribution in the galactic halo.
[17]
oai:arXiv.org:0706.0039 [pdf] - 1934124
First Results from the XENON10 Dark Matter Experiment at the Gran Sasso
National Laboratory
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
Dahl, C. E.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Sorensen, P.;
Schulte, S.;
Winant, C.;
Yamashita, M.
Submitted: 2007-05-31, last modified: 2007-12-03
The XENON10 experiment at the Gran Sasso National Laboratory uses a 15 kg
xenon dual phase time projection chamber (XeTPC) to search for dark matter
weakly interacting massive particles (WIMPs). The detector measures
simultaneously the scintillation and the ionization produced by radiation in
pure liquid xenon, to discriminate signal from background down to 4.5 keV
nuclear recoil energy. A blind analysis of 58.6 live days of data, acquired
between October 6, 2006 and February 14, 2007, and using a fiducial mass of 5.4
kg, excludes previously unexplored parameter space, setting a new 90% C.L.
upper limit for the WIMP-nucleon spin-independent cross-section of 8.8 x
10^{-44} cm^2 for a WIMP mass of 100 GeV/c^2, and 4.5 x 10^{-44} cm^2 for a
WIMP mass of 30 GeV/c^2. This result further constrains predictions of
supersymmetric models.
[18]
oai:arXiv.org:0708.1976 [pdf] - 3998
Preparation of Neutron-activated Xenon for Liquid Xenon Detector
Calibration
Submitted: 2007-08-14, last modified: 2007-09-27
We report the preparation of neutron-activated xenon for the calibration of
liquid xenon (LXe) detectors. Gamma rays from the decay of xenon metastable
states, produced by fast neutron activation, were detected and their activities
measured in a LXe scintillation detector. Following a five-day activation of
natural xenon gas with a Cf-252 (4 x 10^5 n/s) source, the activities of two
gamma ray lines at 164 keV and 236 keV, from Xe-131m and Xe-129m metastable
states, were measured at about 95 and 130 Bq/kg, respectively. We also observed
three additional lines at 35 keV, 100 keV and 275 keV, which decay away within
a few days. No long-lifetime activity was observed after the neutron
activation.