sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Kanai, H.

Normalized to: Kanai, H.

2 article(s) in total. 151 co-authors, from 1 to 2 common article(s). Median position in authors list is 29,5.

[1]  oai:arXiv.org:1811.03886  [pdf] - 1825471
Delta-map method to remove CMB foregrounds with spatially varying spectra
Comments: 31 pages, 8 figures, revised following referee's suggestions, accepted for publication in PTEP
Submitted: 2018-11-09, last modified: 2019-01-31
We extend the internal template foreground removal method by accounting for spatially varying spectral parameters such as the spectral indices of synchrotron and dust emission and the dust temperature. As the previous algorithm had to assume that the spectral parameters are uniform over the full sky (or some significant fraction of the sky), it resulted in a bias in the tensor-to-scalar ratio parameter $r$ estimated from foreground-cleaned polarization maps of the cosmic microwave background (CMB). The new algorithm, "Delta-map method", accounts for spatially varying spectra to first order in perturbation. The only free parameters are the cosmological parameters such as $r$ and the sky-averaged foreground parameters. We show that a cleaned CMB map is the maximum likelihood solution to first order in perturbation, and derive the posterior distribution of $r$ and the sky-averaged foreground parameters using Bayesian statistics. Applying this to realistic simulated sky maps including polarized CMB, synchrotron and thermal dust emission, we find that the new algorithm removes the bias in $r$ down to undetected level in our noiseless simulation ($r\lesssim 4\times 10^{-4}$). We show that the frequency decorrelation of polarized foregrounds due to averaging of spatially varying spectra can be accounted for to first order in perturbation by using slightly different spectral parameters for the Stokes $Q$ and $U$ maps. Finally, we show that the effect of polarized anomalous microwave emission on foreground removal can be absorbed into the curvature parameter of the synchrotron spectrum.
[2]  oai:arXiv.org:1801.06987  [pdf] - 1698011
The LiteBIRD Satellite Mission - Sub-Kelvin Instrument
Suzuki, A.; Ade, P. A. R.; Akiba, Y.; Alonso, D.; Arnold, K.; Aumont, J.; Baccigalupi, C.; Barron, D.; Basak, S.; Beckman, S.; Borrill, J.; Boulanger, F.; Bucher, M.; Calabrese, E.; Chinone, Y.; Cho, H-M.; Cukierman, A.; Curtis, D. W.; de Haan, T.; Dobbs, M.; Dominjon, A.; Dotani, T.; Duband, L.; Ducout, A.; Dunkley, J.; Duval, J. M.; Elleflot, T.; Eriksen, H. K.; Errard, J.; Fischer, J.; Fujino, T.; Funaki, T.; Fuskeland, U.; Ganga, K.; Goeckner-Wald, N.; Grain, J.; Halverson, N. W.; Hamada, T.; Hasebe, T.; Hasegawa, M.; Hattori, K.; Hattori, M.; Hayes, L.; Hazumi, M.; Hidehira, N.; Hill, C. A.; Hilton, G.; Hubmayr, J.; Ichiki, K.; Iida, T.; Imada, H.; Inoue, M.; Inoue, Y.; D., K.; Ishino, H.; Jeong, O.; Kanai, H.; Kaneko, D.; Kashima, S.; Katayama, N.; Kawasaki, T.; Kernasovskiy, S. A.; Keskitalo, R.; Kibayashi, A.; Kida, Y.; Kimura, K.; Kisner, T.; Kohri, K.; Komatsu, E.; Komatsu, K.; Kuo, C. L.; Kurinsky, N. A.; Kusaka, A.; Lazarian, A.; Lee, A. T.; Li, D.; Linder, E.; Maffei, B.; Mangilli, A.; Maki, M.; Matsumura, T.; Matsuura, S.; Meilhan, D.; Mima, S.; Minami, Y.; Mitsuda, K.; Montier, L.; Nagai, M.; Nagasaki, T.; Nagata, R.; Nakajima, M.; Nakamura, S.; Namikawa, T.; Naruse, M.; Nishino, H.; Nitta, T.; Noguchi, T.; Ogawa, H.; Oguri, S.; Okada, N.; Okamoto, A.; Okamura, T.; Otani, C.; Patanchon, G.; Pisano, G.; Rebeiz, G.; Remazeilles, M.; Richards, P. L.; Sakai, S.; Sakurai, Y.; Sato, Y.; Sato, N.; Sawada, M.; Segawa, Y.; Sekimoto, Y.; Seljak, U.; Sherwin, B. D.; Shimizu, T.; Shinozaki, K.; Stompor, R.; Sugai, H.; Sugita, H.; Suzuki, J.; Tajima, O.; Takada, S.; Takaku, R.; Takakura, S.; Takatori, S.; Tanabe, D.; Taylor, E.; Thompson, K. L.; Thorne, B.; Tomaru, T.; Tomida, T.; Tomita, N.; Tristram, M.; Tucker, C.; Turin, P.; Tsujimoto, M.; Uozumi, S.; Utsunomiya, S.; Uzawa, Y.; Vansyngel, F.; Wehus, I. K.; Westbrook, B.; Willer, M.; Whitehorn, N.; Yamada, Y.; Yamamoto, R.; Yamasaki, N.; Yamashita, T.; Yoshida, M.
Comments: 7 pages 2 figures Journal of Low Temperature Physics - Special edition - LTD17 Proceeding
Submitted: 2018-01-22, last modified: 2018-03-15
Inflation is the leading theory of the first instant of the universe. Inflation, which postulates that the universe underwent a period of rapid expansion an instant after its birth, provides convincing explanation for cosmological observations. Recent advancements in detector technology have opened opportunities to explore primordial gravitational waves generated by the inflation through B-mode (divergent-free) polarization pattern embedded in the Cosmic Microwave Background anisotropies. If detected, these signals would provide strong evidence for inflation, point to the correct model for inflation, and open a window to physics at ultra-high energies. LiteBIRD is a satellite mission with a goal of detecting degree-and-larger-angular-scale B-mode polarization. LiteBIRD will observe at the second Lagrange point with a 400 mm diameter telescope and 2,622 detectors. It will survey the entire sky with 15 frequency bands from 40 to 400 GHz to measure and subtract foregrounds. The U.S. LiteBIRD team is proposing to deliver sub-Kelvin instruments that include detectors and readout electronics. A lenslet-coupled sinuous antenna array will cover low-frequency bands (40 GHz to 235 GHz) with four frequency arrangements of trichroic pixels. An orthomode-transducer-coupled corrugated horn array will cover high-frequency bands (280 GHz to 402 GHz) with three types of single frequency detectors. The detectors will be made with Transition Edge Sensor (TES) bolometers cooled to a 100 milli-Kelvin base temperature by an adiabatic demagnetization refrigerator.The TES bolometers will be read out using digital frequency multiplexing with Superconducting QUantum Interference Device (SQUID) amplifiers. Up to 78 bolometers will be multiplexed with a single SQUID amplidier. We report on the sub-Kelvin instrument design and ongoing developments for the LiteBIRD mission.