Normalized to: Kalmus, G.
[1]
oai:arXiv.org:1112.1481 [pdf] - 1092209
Position Reconstruction in a Dual Phase Xenon Scintillation Detector
Solovov, V. N.;
Belov, V. A.;
Akimov, D. Yu.;
Araújo, H. M.;
Barnes, E. J.;
Burenkov, A. A.;
Chepel, V.;
Currie, A.;
DeViveiros, L.;
Edwards, B.;
Ghag, C.;
Hollingsworth, A.;
Horn, M.;
Kalmus, G. E.;
Kobyakin, A. S.;
Kovalenko, A. G.;
Lebedenko, V. N.;
Lindote, A.;
Lopes, M. I.;
Lüscher, R.;
Majewski, P.;
Murphy, A. St J.;
Neves, F.;
Paling, S. M.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Reichhart, L.;
Scovell, P. R.;
Silva, C.;
Smith, N. J. T.;
Smith, P. F.;
Stekhanov, V. N.;
Sumner, T. J.;
Thorne, C.;
Walker, R. J.
Submitted: 2011-12-07, last modified: 2012-09-26
We studied the application of statistical reconstruction algorithms, namely
maximum likelihood and least squares methods, to the problem of event
reconstruction in a dual phase liquid xenon detector. An iterative method was
developed for in-situ reconstruction of the PMT light response functions from
calibration data taken with an uncollimated gamma-ray source. Using the
techniques described, the performance of the ZEPLIN-III dark matter detector
was studied for 122 keV gamma-rays. For the inner part of the detector (R<100
mm), spatial resolutions of 13 mm and 1.6 mm FWHM were measured in the
horizontal plane for primary and secondary scintillation, respectively. An
energy resolution of 8.1% FWHM was achieved at that energy. The possibility of
using this technique for improving performance and reducing cost of
scintillation cameras for medical applications is currently under study.
[2]
oai:arXiv.org:1110.4769 [pdf] - 1085051
WIMP-nucleon cross-section results from the second science run of
ZEPLIN-III
Akimov, D. Yu.;
Araujo, H. M.;
Barnes, E. J.;
Belov, V. A.;
Bewick, A.;
Burenkov, A. A.;
Chepel, V.;
Currie, A.;
DeViveiros, L.;
Edwards, B.;
Ghag, C.;
Hollingsworth, A.;
Horn, M.;
Jones, W. G.;
Kalmus, G. E.;
Kobyakin, A. S.;
Kovalenko, A. G.;
Lebedenko, V. N.;
Lindote, A.;
Lopes, M. I.;
Luscher, R.;
Majewski, P.;
Murphy, A. StJ.;
Neves, F.;
Paling, S. M.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Reichhart, L.;
Scovell, P. R.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Stekhanov, V. N.;
Sumner, T. J.;
Thorne, C.;
Walker, R. J.
Submitted: 2011-10-21, last modified: 2011-12-16
We report experimental upper limits on WIMP-nucleon elastic scattering cross
sections from the second science run of ZEPLIN-III at the Boulby Underground
Laboratory. A raw fiducial exposure of 1,344 kg.days was accrued over 319 days
of continuous operation between June 2010 and May 2011. A total of eight events
was observed in the signal acceptance region in the nuclear recoil energy range
7-29 keV, which is compatible with background expectations. This allows the
exclusion of the scalar cross-section above 4.8E-8 pb near 50 GeV/c^2 WIMP mass
with 90% confidence. Combined with data from the first run, this result
improves to 3.9E-8 pb. The corresponding WIMP-neutron spin-dependent
cross-section limit is 8.0E-3 pb. The ZEPLIN programme reaches thus its
conclusion at Boulby, having deployed and exploited successfully three liquid
xenon experiments of increasing reach.
[3]
oai:arXiv.org:1111.2248 [pdf] - 1091528
Quenching Factor for Low Energy Nuclear Recoils in a Plastic
Scintillator
Reichhart, L.;
Akimov, D. Yu.;
Araujo, H. M.;
Barnes, E. J.;
Belov, V. A.;
Burenkov, A. A.;
Chepel, V.;
Currie, A.;
DeViveiros, L.;
Edwards, B.;
Francis, V.;
Ghag, C.;
Hollingsworth, A.;
Horn, M.;
Kalmus, G. E.;
Kobyakin, A. S.;
Kovalenko, A. G.;
Lebedenko, V. N.;
Lindote, A.;
Lopes, M. I.;
Luscher, R.;
Majewski, P.;
Murphy, A. St J.;
Neves, F.;
Paling, S. M.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Scovell, P. R.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Stekhanov, V. N.;
Sumner, T. J.;
Thorne, C.;
Walker, R. J.
Submitted: 2011-11-09
Plastic scintillators are widely used in industry, medicine and scientific
research, including nuclear and particle physics. Although one of their most
common applications is in neutron detection, experimental data on their
response to low-energy nuclear recoils are scarce. Here, the relative
scintillation efficiency for neutron-induced nuclear recoils in a
polystyrene-based plastic scintillator (UPS-923A) is presented, exploring
recoil energies between 125 keV and 850 keV. Monte Carlo simulations,
incorporating light collection efficiency and energy resolution effects, are
used to generate neutron scattering spectra which are matched to observed
distributions of scintillation signals to parameterise the energy-dependent
quenching factor. At energies above 300 keV the dependence is reasonably
described using the semi-empirical formulation of Birks and a kB factor of
(0.014+/-0.002) g/MeVcm^2 has been determined. Below that energy the measured
quenching factor falls more steeply than predicted by the Birks formalism.
[4]
oai:arXiv.org:1106.0808 [pdf] - 1077078
ZE3RA: The ZEPLIN-III Reduction and Analysis Package
Neves, F.;
Akimov, D. Yu.;
Araújo, H. M.;
Barnes, E. J.;
Belov, V. A.;
Burenkov, A. A.;
Chepel, V.;
Currie, A.;
DeViveiros, L.;
Edwards, B.;
Ghag, C.;
Hollingsworth, A.;
Horn, M.;
Kalmus, G. E.;
Kobyakin, A. S.;
Kovalenko, A. G.;
Lebedenko, V. N.;
Lindote, A.;
Lopes, M. I.;
Lüscher, R.;
Majewski, P.;
Murphy, A. St J.;
Paling, S. M.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Reichhart, L.;
Rodrigues, S.;
Scovell, P. R.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Stekhanov, V. N.;
Sumner, T. J.;
Thorne, C.;
Walker, R. J.
Submitted: 2011-06-04
ZE3RA is the software package responsible for processing the raw data from
the ZEPLIN-III dark matter experiment and its reduction into a set of
parameters used in all subsequent analyses. The detector is a liquid xenon time
projection chamber with scintillation and electroluminescence signals read out
by an array of 31 photomultipliers. The dual range 62-channel data stream is
optimised for the detection of scintillation pulses down to a single
photoelectron and of ionisation signals as small as those produced by single
electrons. We discuss in particular several strategies related to data
filtering, pulse finding and pulse clustering which are tuned to recover the
best electron/nuclear recoil discrimination near the detection threshold, where
most dark matter elastic scattering signatures are expected. The software was
designed assuming only minimal knowledge of the physics underlying the
detection principle, allowing an unbiased analysis of the experimental results
and easy extension to other detectors with similar requirements.
[5]
oai:arXiv.org:1103.0393 [pdf] - 385243
Performance of the veto detector incorporated into the ZEPLIN-III
experiment
Ghag, C.;
Akimov, D. Yu.;
Araújo, H. M.;
Barnes, E. J.;
Belov, V. A.;
Burenkov, A. A.;
Chepel, V.;
Currie, A.;
DeViveiros, L.;
Edwards, B.;
Francis, V.;
Hollingsworth, A.;
Horn, M.;
Kalmus, G. E.;
Kobyakin, A. S.;
Kovalenko, A. G.;
Lebedenko, V. N.;
Lindote, A.;
Lopes, M. I.;
Lüscher, R.;
Lyons, K.;
Majewski, P.;
St, A.;
Murphy, J.;
Neves, F.;
Paling, S. M.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Reichhart, L.;
Scovell, P. R.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Stekhanov, V. N.;
Sumner, T. J.;
Thorne, C.;
Walker, R. J.
Submitted: 2011-03-02, last modified: 2011-05-01
The ZEPLIN-III experiment is operating in its second phase at the Boulby
Underground Laboratory in search of dark matter WIMPs. The major upgrades to
the instrument over its first science run include lower background
photomultiplier tubes and installation of a plastic scintillator veto system.
Performance results from the veto detector using calibration and science data
in its first six months of operation in coincidence with ZEPLIN-III are
presented. With fully automated operation and calibration, the veto system has
maintained high stability and achieves near unity live time relative to
ZEPLIN-III. Calibrations with a neutron source demonstrate a rejection of 60%
of neutron-induced nuclear recoils in ZEPLIN-III that might otherwise be
misidentified as WIMPs. This tagging efficiency reduces the expected untagged
nuclear recoil background from neutrons during science data taking to a very
low rate of ~0.2 events per year in the WIMP acceptance region. Additionally,
the veto detector provides rejection of 28% of gamma-ray induced background
events, allowing the sampling of the dominant source of background in
ZEPLIN-III - multiple scatter gamma-rays with rare topologies. Since WIMPs will
not be tagged by the veto detector, and tags due to gamma-rays and neutrons are
separable, this population of multiple scatter events may be characterised
without biasing the analysis of candidate WIMP signals in the data.
[6]
oai:arXiv.org:1004.4207 [pdf] - 325335
The ZEPLIN-III Anti-Coincidence Veto Detector
Akimov, D. Yu.;
Araujo, H. M.;
Barnes, E. J.;
Belov, V. A.;
Burenkov, A. A.;
Chepel, V.;
Currie, A.;
Edwards, B.;
Francis, V.;
Ghag, C.;
Hollingsworth, A.;
Horn, M.;
Kalmus, G. E.;
Kobyakin, A. S.;
Kovalenko, A. G.;
Lebedenko, V. N.;
Lindote, A.;
Lopes, M. I.;
Luscher, R.;
Lyons, K.;
Majewski, P.;
Murphy, A. StJ.;
Neves, F.;
Paling, S. M.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Reichhart, L.;
Scovell, P. R.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Stekhanov, V. N.;
Sumner, T. J.;
Taylor, R.;
Thorne, C.;
Walker, R. J.
Submitted: 2010-04-23, last modified: 2010-04-27
The design, optimisation and construction of an anti-coincidence veto
detector to complement the ZEPLIN-III direct dark matter search instrument is
described. One tonne of plastic scintillator is arranged into 52 bars
individually read out by photomultipliers and coupled to a gadolinium-loaded
passive polypropylene shield. Particular attention has been paid to
radiological content. The overall aim has been to achieve a veto detector of
low threshold and high efficiency without the creation of additional background
in ZEPLIN-III, all at a reasonable cost. Extensive experimental measurements of
the components have been made, including radioactivity levels and performance
characteristics. These have been used to inform a complete end-to-end Monte
Carlo simulation that has then been used to calculate the expected performance
of the new instrument, both operating alone and as an anti-coincidence detector
for ZEPLIN-III. The veto device will be capable of rejecting over 65% of
coincident nuclear recoil events from neutron background in the energy range of
interest in ZEPLIN-III. This will reduce the background in ZEPLIN-III from ~0.4
to ~0.14 events per year in the WIMP acceptance region, a significant factor in
the event of a non-zero observation. Furthermore, in addition to providing
valuable diagnostic capabilities, the veto is capable of tagging over 15% for
gamma-ray rejection, all whilst contributing no significant additional
background. In conjunction with the replacement of the internal ZEPLIN-III
photomultiplier array, the new veto is expected to improve significantly the
sensitivity of the ZEPLIN-III instrument to dark matter, allowing spin
independent WIMP-nucleon cross sections below 1E-8 pb to be probed.
[7]
oai:arXiv.org:0812.1150 [pdf] - 19200
Results from the First Science Run of the ZEPLIN-III Dark Matter Search
Experiment
Lebedenko, V. N.;
Araujo, H. M.;
Barnes, E. J.;
Bewick, A.;
Cashmore, R.;
Chepel, V.;
Currie, A.;
Davidge, D.;
Dawson, J.;
Durkin, T.;
Edwards, B.;
Ghag, C.;
Horn, M.;
Howard, A. S.;
Hughes, A. J.;
Jones, W. G.;
Joshi, M.;
Kalmus, G. E.;
Kovalenko, A. G.;
Lindote, A.;
Liubarsky, I.;
Lopes, M. I.;
Luscher, R.;
Majewski, P.;
Murphy, A. StJ.;
Neves, F.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Scovell, P. R.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Stekhanov, V. N.;
Sumner, T. J.;
Thorne, C.;
Walker, R. J.
Submitted: 2008-12-05, last modified: 2009-09-02
The ZEPLIN-III experiment in the Palmer Underground Laboratory at Boulby uses
a 12kg two-phase xenon time projection chamber to search for the weakly
interacting massive particles (WIMPs) that may account for the dark matter of
our Galaxy. The detector measures both scintillation and ionisation produced by
radiation interacting in the liquid to differentiate between the nuclear
recoils expected from WIMPs and the electron recoil background signals down to
~10keV nuclear recoil energy. An analysis of 847kg.days of data acquired
between February 27th 2008 and May 20th 2008 has excluded a WIMP-nucleon
elastic scattering spin-independent cross-section above 8.1x10(-8)pb at
55GeV/c2 with a 90% confidence limit. It has also demonstrated that the
two-phase xenon technique is capable of better discrimination between electron
and nuclear recoils at low-energy than previously achieved by other xenon-based
experiments.