Kading, T. J.
Normalized to: Kading, T.
2 article(s) in total. 35 co-authors, from 1 to 2 common article(s). Median position in authors list is 10,0.
[1]
oai:arXiv.org:1101.1940 [pdf] - 288646
An Optical Readout TPC (O-TPC) for Studies in Nuclear Astrophysics With
Gamma-Ray Beams at HIgS
Gai, M.;
Ahmed, M. W.;
Stave, S. C.;
Zimmerman, W. R.;
Breskin, A.;
Bromberger, B.;
Chechik, R.;
Dangendorf, V.;
Delbar, Th.;
France, R. H.;
Henshaw, S. S.;
Kading, T. J.;
Martel, P. P.;
McDonald, J. E. R.;
Seo, P. -N.;
Tittelmeier, K.;
Weller, H. R.;
Young, A. H.
Submitted: 2011-01-10
We report on the construction, tests, calibrations and commissioning of an
Optical Readout Time Projection Chamber (O-TPC) detector operating with a
CO2(80%) + N2(20%) gas mixture at 100 and 150 Torr. It was designed to measure
the cross sections of several key nuclear reactions involved in stellar
evolution. In particular, a study of the rate of formation of oxygen and carbon
during the process of helium burning will be performed by exposing the chamber
gas to intense nearly mono-energetic gamma-ray beams at the High Intensity
Gamma Source (HIgS) facility. The O-TPC has a sensitive target-drift volume of
30x30x21 cm^3. Ionization electrons drift towards a double parallel grid
avalanche multiplier, yielding charge multiplication and light emission.
Avalanche induced photons from N2 emission are collected, intensified and
recorded with a Charge Coupled Device (CCD) camera, providing two-dimensional
track images. The event's time projection (third coordinate) and the deposited
energy are recorded by photomultipliers and by the TPC charge-signal,
respectively. A dedicated VME-based data acquisition system and associated data
analysis tools were developed to record and analyze these data. The O-TPC has
been tested and calibrated with 3.183 MeV alpha-particles emitted by a 148Gd
source placed within its volume with a measured energy resolution of 3.0%.
Tracks of alpha and 12C particles from the dissociation of 16O and of three
alpha-particles from the dissociation of 12C have been measured during initial
in-beam test experiments performed at the HIgS facility at Duke University. The
full detection system and its performance are described and the results of the
preliminary in-beam test experiments are reported.
[2]
oai:arXiv.org:nucl-ex/0608027 [pdf] - 118485
In Beam Tests of Implanted Helium Targets
McDonald, J. E.;
France, R. H.;
Jarvis, R. A.;
Ahmed, M. W.;
Blackston, M. A.;
Delbar, Th.;
Gai, M.;
Kading, T. J.;
Parpottas, Y.;
Perdue, B. A.;
Prior, R. M.;
Rubin, D. A.;
Spraker, M. C.;
Yeomans, J. D.;
Weissman, L.;
Weller, H. R.;
Wilds, E. L.;
;
;
UHartford;
GCSU;
LNS/UConn;
TUNL/Duke;
UCL/LLN;
Yale;
NGCSU
Submitted: 2006-08-16
Targets consisting of 3,4He implanted into thin aluminum foils (approximately
100, 200 or 600 ug/cm^2) were prepared using intense (a few uA) helium beams at
low energy (approximately 20, 40 or 100 keV). Uniformity of the implantation
was achieved by a beam raster across a 12 mm diameter tantalum collimator at
the rates of 0.1 Hz in the vertical direction and 1 Hz in the horizontal
direction. Helium implantation into the very thin (approximately 80-100
ug/cm^2) aluminum foils failed to produce useful targets (with only
approximately 10% of the helium retained) due to an under estimation of the
range by the code SRIM. The range of low energy helium in aluminum predicted by
Northcliffe and Shilling and the NIST online tabulation are observed on the
other hand to over estimate the range of low energy helium ions in aluminum. An
attempt to increase the amount of helium by implanting a second deeper layer
was also carried out, but it did not significantly increase the helium content
beyond the blistering limit (approximately 6 x 10^17 helium/cm^2). The
implanted targets were bombarded with moderately intense 4He and 16O beams of
50-100 particle nA . Rutherford Back Scattering of 1.0 and 2.5 MeV proton beams
and recoil helium from 15.0 MeV oxygen beams were used to study the helium
content and profile before, during and after bombardments. We observed the
helium content and profile to be very stable even after a prolonged bombardment
(up to two days) with moderately intense beams of 16O or 4He. Helium implanted
into thin (aluminum) foils is a good choice for thin helium targets needed, for
example, for a measurement of the 3he(a,g)7Be reaction and the associated S34
astrophysical cross section factor (S-factor).