Normalized to: Junior, O.
[1]
oai:arXiv.org:1408.2847 [pdf] - 863451
Fiber Optical Cable and Connector System (FOCCoS) for PFS/Subaru
de Oliveira, Antonio Cesar;
de Oliveira, Lígia Souza;
de Arruda, Márcio V.;
Marrara, Lucas Souza;
Santos, Leandro H. dos;
Ferreira, Décio;
Santos, Jesulino B. dos;
Rosa, Josimar A.;
Junior, Orlando V.;
Pereira, Jeferson M.;
Castilho, Bruno;
Gneiding, Clemens;
Junior, Laerte S.;
de Oliveira, Claudia M.;
Gunn, James E.;
Ueda, Akitoshi;
Takato, Naruhisa;
Shimono, Atsushi;
Sugai, Hajime;
Karoji, Hiroshi;
Kimura, Masahiko;
Tamura, Naoyuki;
Wang, Shiang-Yu;
Murray, Graham;
Mignant, David Le;
Madec, Fabrice;
Jaquet, Marc;
Vives, Sebastien;
Fisher, Charlie;
Braun, David;
Schwochert, Mark;
Reiley, Daniel J.
Submitted: 2014-08-12
FOCCoS, Fiber Optical Cable and Connector System, has the main function of
capturing the direct light from the focal plane of Subaru Telescope using
optical fibers, each one with a microlens in its tip, and conducting this light
through a route containing connectors to a set of four spectrographs. The
optical fiber cable is divided in 3 different segments called Cable A, Cable B
and Cable C. Multi-fibers connectors assure precise connection among all
optical fibers of the segments, providing flexibility for instrument changes.
To assure strong and accurate connection, these sets are arranged inside two
types of assemblies: the Tower Connector, for connection between Cable C and
Cable B; and the Gang Connector, for connection between Cable B and Cable A.
Throughput tests were made to evaluate the efficiency of the connections. A
lifetime test connection is in progress. Cable C is installed inside the PFI,
Prime Focus Instrument, where each fiber tip with a microlens is bonded to the
end of the shaft of a 2-stage piezo-electric rotatory motor positioner; this
assembly allows each fiber to be placed anywhere within its patrol region,
which is 9.5mm diameter.. Each positioner uses a fiber arm to support the
ferrule, the microlens, and the optical fiber. 2400 of these assemblies are
arranged on a motor bench plate in a hexagonal-closed-packed disposition.
[2]
oai:arXiv.org:1408.2848 [pdf] - 863452
Slit device for FOCCoS, PFS, Subaru
de Oliveira, Antonio Cesar;
Gunn, James E.;
de Oliveira, Ligia Souza;
de Arruda, Marcio Vital;
Marrara, Lucas Souza;
Santos, Leandro Henrique dos;
Ferreira, Décio;
Santos, Jesulino Bispo dos;
Rosa, Josimar Aparecido;
Ribeiro, Flavio Felipe;
Vilaça, Rodrigo de Paiva;
Junior, Orlando Verducci;
Junior, Laerte Sodré;
de Oliveira, Claudia Mendes
Submitted: 2014-08-12
The Fiber Optical Cable and Connector System, FOCCoS, subsystem of the Prime
Focus Spectrograph, PFS, for Subaru telescope, is responsible to feed four
spectrographs with a set of optical fibers cables. The light injection for each
spectrograph is assured by a convex curved slit with a linear array of 616
optical fibers. In this paper we present a design of a slit that ensures the
right direction of the fibers by using masks of micro holes. This kind of mask
is made by a technique called electroforming, which is able to produce a nickel
plate with holes in a linear sequence. The precision error is around 1micron in
the diameter and 1 micron in the positions of the holes. This nickel plate may
be produced with a thickness between 50 and 200 microns, so it may be very
flexible. This flexibility allows the mask to be bent into the shape necessary
for a curved slit. The concept requires two masks, which we call Front Mask,
and Rear Mask, separated by a gap that defines the thickness of the slit. The
pitch and the diameter of the holes define the linear geometry of the slit; the
curvature of each mask defines the angular geometry of the slit. Obviously,
this assembly must be mounted inside a structure rigid and strong enough to be
supported inside the spectrograph. This structure must have a CTE optimized to
avoid displacement of the fibers or increased FRD of the fibers when the device
is submitted to temperatures around 3 degrees Celsius, the temperature of
operation of the spectrograph. We have produced two models. Both are mounted
inside a very compact Invar case, and both have their front surfaces covered by
a dark composite, to reduce stray light. Furthermore, we have conducted
experiments with two different internal structures to minimize effects caused
by temperature gradients.