Julian, Roger
Normalized to: Julian, R.
2 article(s) in total. 42 co-authors, from 1 to 2 common article(s). Median position in authors list is 10,5.
[1]
oai:arXiv.org:0809.0634 [pdf] - 15943
Optical-mechanical operation of the F2T2 Filter: a tunable filter
designed to search for First Light
Mentuch, Erin;
Scott, Alan;
Abraham, Roberto;
Barton, Elizabeth;
Bershady, Matthew;
Bland-Hawthorn, Joss;
Crampton, David;
Doyon, Rene;
Eikenberry, Steve;
Gladders, Mike;
Glazebrook, Karl;
Jenson, Joe;
Julian, Jeff;
Julian, Roger;
Kneib, Jean-Paul;
Loop, David;
Raines, Nick;
Rowlands, Neil;
Smith, J. D.
Submitted: 2008-09-03
The Flamingos-2 Tandem Tunable filter is a tunable, narrow-band filter,
consisting of two Fabry-Perot etalons in series, capable of scanning to any
wavelength from 0.95 to 1.35 microns with a spectral resolution of R~800. It is
an accessory mode instrument for the near-IR Flamingos-2 imaging-spectrograph
designed for the Gemini South 8m Observatory and will be fed through the
upcoming Multi-Conjugate Adaptive Optics feed. The primary science goal of the
F2T2 filter is to perform a ground-based search for the first star forming
regions in the universe at redshifts of 7 < z < 11. The construction of the
F2T2 filter is complete and it is currently in its calibration and
commissioning phases. In this proceeding, we describe the calibration and
performance of the instrument.
[2]
oai:arXiv.org:astro-ph/0604577 [pdf] - 81646
FLAMINGOS-2: The Facility Near-Infrared Wide-field Imager & Multi-Object
Spectrograph for Gemini
Eikenberry, Stephen;
Elston, Richard;
Raines, S. Nicholas;
Julian, Jeff;
Hanna, Kevin;
Hon, David;
Julian, Roger;
Bandyopadhyay, R.;
Bennett, J. Greg;
Bessoff, Aaron;
Branch, Matt;
Corley, Richard;
Eriksen, John-David;
Frommeyer, Skip;
Gonzalez, Anthony;
Herlevich, Michael;
Marin-Franch, Antonio;
Marti, Jose;
Murphey, Charlie;
Rashkin, David;
Warner, Craig;
Leckie, Brian;
Gardhouse, W. Rusty;
Fletcher, Murray;
Dunn, Jennifer;
Wooff, Robert;
Hardy, Tim
Submitted: 2006-04-27
We report on the design and status of the FLAMINGOS-2 instrument - a
fully-cryogenic facility near-infrared imager and multi-object spectrograph for
the Gemini 8-meter telescopes. FLAMINGOS-2 has a refractive all-spherical
optical system providing 0.18-arcsecond pixels and a 6.2-arcminute circular
field-of-view on a 2048x2048-pixel HAWAII-2 0.9-2.4 mm detector array. A
slit/decker wheel mechanism allows the selection of up to 9 multi-object
laser-machined plates or 3 long slits for spectroscopy over a 6x2-arcminute
field of view, and selectable grisms provide resolutions from $\sim$ 1300 to
$\sim $3000 over the entire spectrograph bandpass. FLAMINGOS-2 is also
compatible with the Gemini Multi-Conjugate Adaptive Optics system, providing
multi-object spectroscopic capabilities over a 3x1-arcminute field with high
spatial resolution (0.09-arcsec/pixel). We review the designs of optical,
mechanical, electronics, software, and On-Instrument WaveFront Sensor
subsystems. We also present the current status of the project, currently in
final testing in mid-2006.