Normalized to: Jimenez-Monferrer, S.
[1]
oai:arXiv.org:1003.2368 [pdf] - 1025658
On the coherence loss in phase-referenced VLBI observations
Submitted: 2010-03-11, last modified: 2010-04-12
Context: Phase referencing is a standard calibration technique in radio
interferometry, particularly suited for the detection of weak sources close to
the sensitivity limits of the interferometers. However, effects from a changing
atmosphere and inaccuracies in the correlator model may affect the
phase-referenced images, leading to wrong estimates of source flux densities
and positions. A systematic observational study of signal decoherence in phase
referencing, and its effects in the image plane, has not been performed yet.
Aims: We systematically studied how the signal coherence in
Very-Long-Baseline-Interferometry (VLBI) observations is affected by a
phase-reference calibration at different frequencies and for different
calibrator-to-target separations. The results obtained should be of interest
for a correct interpretation of many phase-referenced observations with VLBI.
Methods: We observed a set of 13 strong sources (the S5 polar cap sample) at
8.4 and 15 GHz in phase-reference mode, with 32 different calibrator/target
combinations spanning angular separations between 1.5 and 20.5 degrees. We
obtained phase-referenced images and studied how the dynamic range and peak
flux density depend on observing frequency and source separation.
Results: We obtained dynamic ranges and peak flux densities of the
phase-referenced images as a function of frequency and separation from the
calibrator. We compared our results with models and phenomenological equations
previously reported.
Conclusions: The dynamic range of the phase-referenced images is strongly
limited by the atmosphere at all frequencies and for all source separations.
The limiting dynamic range is inversely proportional to the sine of the
calibrator-to-target separation. We also find that the peak flux densities,
relative to those obtained with the self-calibrated images, decrease with
source separation.
[2]
oai:arXiv.org:1004.1624 [pdf] - 294746
Atmospheric turbulence in phase-referenced and wide-field
interferometric images: Application to the SKA
Submitted: 2010-04-09
Phase referencing is a standard calibration procedure in radio
interferometry. It allows to detect weak sources by using quasi-simultaneous
observations of closeby sources acting as calibrators. Therefore, it is assumed
that, for each antenna, the optical paths of the signals from both sources are
similar. However, atmospheric turbulence may introduce strong differences in
the optical paths of the signals and affect, or even waste, phase referencing
for cases of relatively large calibrator-to-target separations and/or bad
weather. The situation is similar in wide-field observations, since the random
deformations of the images, mostly caused by atmospheric turbulence, have
essentially the same origin as the random astrometric variations of
phase-referenced sources with respect to the phase center of their calibrators.
In this paper, we present the results of a Monte Carlo study of the astrometric
precision and sensitivity of an interferometric array (a realization of the
Square Kilometre Array, SKA) in phase-referenced and wide-field observations.
These simulations can be extrapolated to other arrays by applying the
corresponding corrections. We consider several effects from the turbulent
atmosphere (i.e., ionosphere and wet component of the troposphere) and also
from the antenna receivers. We study the changes in dynamic range and
astrometric precision as a function of observing frequency, source separation,
and strength of the turbulence. We find that, for frequencies between 1 and 10
GHz, it is possible to obtain images with high fidelity, although the
atmosphere strongly limits the sensitivity of the instrument compared to the
case with no atmosphere. Outside this frequency window, the dynamic range of
the images and the accuracy of the source positions decrease. [...] (Incomplete
abstract. Please read manuscript.)